-
Measurement Techniques for Low Emittance Tuning and Beam Dynamics at CESR
Authors:
M. G. Billing,
J. A. Dobbins,
M. J. Forster,
D. L. Kreinick,
R. E. Meller,
D. P. Peterson,
G. A. Ramirez,
M. C. Rendina,
N. T. Rider,
D. C. Sagan,
J. Shanks,
J. P. Sikora,
M. G. Stedinger,
C. R. Strohman,
H. A. Williams,
M. A. Palmer,
R. L. Holtzapple,
J. Flanagan
Abstract:
After operating as a High Energy Physics electron-positron collider, the Cornell Electron-positron Storage Ring (CESR) has been converted to become a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS). Over the course of several years CESR was adapted for accelerator physics research as a test accelerator, capable of studying topics relevant to future damping…
▽ More
After operating as a High Energy Physics electron-positron collider, the Cornell Electron-positron Storage Ring (CESR) has been converted to become a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS). Over the course of several years CESR was adapted for accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Initially some specific topics were targeted for accelerator physic research with the storage ring in this mode, labeled CesrTA. These topics included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud (EC) development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere. A number of specific instruments were developed for CesrTA. Much of the pre-existing instrumentation was modified to accommodate the scope of these studies and these are described in a companion paper. To complete this research, a number of procedures were developed or modified, often requiring coordinated measurements among different instruments. This paper provides an overview of types of measurements employed for the study of beam dynamics during the operation of CesrTA.
△ Less
Submitted 15 March, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Instrumentation for the Study of Low Emittance Tuning and Beam Dynamics at CESR
Authors:
M. G. Billing,
J. A. Dobbins,
M. J. Forster,
D. L. Kreinick,
R. E. Meller,
D. P. Peterson,
G. A. Ramirez,
M. C. Rendina,
N. T. Rider,
D. C. Sagan,
J. Shanks,
J. P. Sikora,
M. G. Stedinger,
C. R. Strohman,
H. A. Williams,
M. A. Palmer,
R. L. Holtzapple,
J. Flanagan
Abstract:
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the sp…
▽ More
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.
△ Less
Submitted 14 November, 2017; v1 submitted 4 October, 2017;
originally announced October 2017.
-
Self-diffusion and binary Maxwell-Stefan diffusion coefficients of quadrupolar real fluids from molecular simulation
Authors:
Gimmy Alex Fernandez Ramirez,
Jadran Vrabec,
Hans Hasse
Abstract:
Self- and binary Maxwell-Stefan diffusion coefficients were determined by equilibrium molecular dynamics simulations with the Green-Kubo method. This study covers self-diffusion coefficients at liquid states for eight pure fluids, i.e. F$_2$, N$_2$, CO$_2$, CS$_2$, C$_2$H$_6$, C$_2$H$_4$, C$_2$H$_2$ and SF$_6$ as well as Maxwell-Stefan diffusion coefficients for three binary mixtures N$_2$+CO…
▽ More
Self- and binary Maxwell-Stefan diffusion coefficients were determined by equilibrium molecular dynamics simulations with the Green-Kubo method. This study covers self-diffusion coefficients at liquid states for eight pure fluids, i.e. F$_2$, N$_2$, CO$_2$, CS$_2$, C$_2$H$_6$, C$_2$H$_4$, C$_2$H$_2$ and SF$_6$ as well as Maxwell-Stefan diffusion coefficients for three binary mixtures N$_2$+CO$_2$, N$_2$+C$_2$H$_6$ and CO$_2$+C$_2$H$_6$. The fluids were modeled by the two-center Lennard-Jones plus point-quadrupole pair potential, with parameters taken from previous work of our group which were determined solely on the basis of vapor-liquid equilibrium data. Self-diffusion coefficients are predicted with a statistical uncertainty less than 1% and they agree within 2% to 28% with the experimental data. The correction of the simulation data due to the finite size of the system increases the value of the self-diffusion coefficient typically by 10%. If this correction is considered, better agreement with the experimental data can be expected for most of the studied fluids. Maxwell-Stefan diffusion coefficients for three binary mixtures were also predicted, their statistical uncertainty is about 10%. These results were used to test three empirical equations to estimate Maxwell-Stefan diffusion coefficients in binary mixtures, i.e. the equations of Caldwell and Babb, of Darken, and of Vignes. The equations of Caldwell and Babb and of Vignes show qualitatively different behavior of the Maxwell-Stefan diffusion coefficient than that observed in the simulations. In agreement with previous work, the best results are obtained in all cases with the equation of Darken.
△ Less
Submitted 29 April, 2009;
originally announced April 2009.