-
Measurement Techniques for Low Emittance Tuning and Beam Dynamics at CESR
Authors:
M. G. Billing,
J. A. Dobbins,
M. J. Forster,
D. L. Kreinick,
R. E. Meller,
D. P. Peterson,
G. A. Ramirez,
M. C. Rendina,
N. T. Rider,
D. C. Sagan,
J. Shanks,
J. P. Sikora,
M. G. Stedinger,
C. R. Strohman,
H. A. Williams,
M. A. Palmer,
R. L. Holtzapple,
J. Flanagan
Abstract:
After operating as a High Energy Physics electron-positron collider, the Cornell Electron-positron Storage Ring (CESR) has been converted to become a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS). Over the course of several years CESR was adapted for accelerator physics research as a test accelerator, capable of studying topics relevant to future damping…
▽ More
After operating as a High Energy Physics electron-positron collider, the Cornell Electron-positron Storage Ring (CESR) has been converted to become a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS). Over the course of several years CESR was adapted for accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Initially some specific topics were targeted for accelerator physic research with the storage ring in this mode, labeled CesrTA. These topics included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud (EC) development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere. A number of specific instruments were developed for CesrTA. Much of the pre-existing instrumentation was modified to accommodate the scope of these studies and these are described in a companion paper. To complete this research, a number of procedures were developed or modified, often requiring coordinated measurements among different instruments. This paper provides an overview of types of measurements employed for the study of beam dynamics during the operation of CesrTA.
△ Less
Submitted 15 March, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Instrumentation for the Study of Low Emittance Tuning and Beam Dynamics at CESR
Authors:
M. G. Billing,
J. A. Dobbins,
M. J. Forster,
D. L. Kreinick,
R. E. Meller,
D. P. Peterson,
G. A. Ramirez,
M. C. Rendina,
N. T. Rider,
D. C. Sagan,
J. Shanks,
J. P. Sikora,
M. G. Stedinger,
C. R. Strohman,
H. A. Williams,
M. A. Palmer,
R. L. Holtzapple,
J. Flanagan
Abstract:
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the sp…
▽ More
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.
△ Less
Submitted 14 November, 2017; v1 submitted 4 October, 2017;
originally announced October 2017.
-
Beam Position Monitoring System at CESR
Authors:
M. G. Billing,
W. F. Bergan,
M. J. Forster,
R. E. Meller,
M. C. Rendina,
N. T. Rider,
D. C. Sagan,
J. Shanks,
J. P. Sikora,
M. G. Stedinger,
C. R. Strohman,
M. A. Palmer,
R. L. Holtzapple
Abstract:
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the sp…
▽ More
The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode, labeled CesrTA (CESR as a Test Accelerator), included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere. As a part of this conversion the CESR beam position monitoring (CBPM) system was completely upgraded to provide the needed instrumental capabilities for these studies. This paper describes the new CBPM system hardware, its function and representative measurements performed by the upgraded system.
△ Less
Submitted 4 August, 2017; v1 submitted 1 June, 2017;
originally announced June 2017.
-
The Conversion of CESR to Operate as the Test Accelerator, CesrTA, Part 4: Superconducting Wiggler Diagnostics
Authors:
M. G. Billing,
S. Greenwald,
X. Liu,
Y. Li,
D. Sabol,
E. N. Smith,
C. R. Strohman,
M. A. Palmer,
D. V. Munson
Abstract:
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it appropriate for the study of a wide spectrum of accelerator physics issues and instrumentation…
▽ More
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it appropriate for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper, the last in a series of four, describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of electron cloud (EC) behavior within wigglers. Earlier papers provided an overview of the accelerator physics program, the general modifications of CESR, the modifications of the vacuum system necessary for the conversion of CESR to the test accelerator, CesrTA, enhanced to study such subjects as low emittance tuning methods, EC effects, intra-beam scattering, fast ion instabilities as well as general improvements to beam instrumentation. While the initial studies of CesrTA focussed on questions related to the International Linear Collider damping ring design, CESR is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.
△ Less
Submitted 18 October, 2016; v1 submitted 23 August, 2016;
originally announced August 2016.
-
The Conversion of CESR to Operate as the Test Accelerator, CesrTA, Part 3: Electron Cloud Diagnostics
Authors:
M. G. Billing,
J. V. Conway,
J. A. Crittendan,
S. Greenwald,
Y. Li,
R. E. Meller,
C. R. Strohman,
J. P. Sikora,
J. R. Calvey,
M. A. Palmer
Abstract:
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation relate…
▽ More
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper is the third in a series of four describing the the conversion of CESR to the test accelerator, CesrTA. The first two papers discuss the overall plan for the conversion of the storage ring to an instrument capable of studying advanced accelerator physics issues and the details of the vacuum system upgrades. This paper focusses on the necessary development of new instrumentation, situated in four dedicated experimental regions, capable of studying such phenomena as electron clouds (ECs) and methods to mitigate EC effects. The fourth paper in this series describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. While the initial studies of CesrTA focussed on questions related to the International Linear Collider damping ring design, CesrTA is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.
△ Less
Submitted 31 March, 2016; v1 submitted 2 December, 2015;
originally announced December 2015.
-
The Conversion of CESR to Operate as the Test Accelerator, CesrTA, Part 2: Vacuum Modifications
Authors:
M. G. Billing,
Y. Li
Abstract:
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation relate…
▽ More
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper, the second in a series of four, discusses the modifications of the vacuum system necessary for the conversion of CESR to the test accelerator, CesrTA, enhanced to study such subjects as low emittance tuning methods, electron cloud (EC) effects, intra-beam scattering, fast ion instabilities as well as general improvements to beam instrumentation. A separate paper describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. While the initial studies of CesrTA focussed on questions related to the International Linear Collider (ILC) damping ring design, CesrTA is a very flexible storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.
△ Less
Submitted 26 June, 2015; v1 submitted 12 May, 2015;
originally announced May 2015.
-
The Conversion of CESR to Operate as the Test Accelerator, CesrTA, Part 1: Overview
Authors:
M. G. Billing
Abstract:
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation relate…
▽ More
Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper outlines the motivation, design and conversion of CESR to a test accelerator, CesrTA, enhanced to study such subjects as low emittance tuning methods, electron cloud (EC) effects, intra-beam scattering, fast ion instabilities as well as general improvements to beam instrumentation. While the initial studies of CesrTA focussed on questions related to the International Linear Collider (ILC) damping ring design, CesrTA is a very flexible storage ring, capable of studying a wide range of accelerator physics and instrumentation questions. This paper contains the outline and the basis for a set of papers documenting the reconfiguration of the storage ring and the associated instrumentation required for the studies described above. Further details may be found in these papers.
△ Less
Submitted 4 May, 2015; v1 submitted 25 March, 2015;
originally announced March 2015.
-
Shielded button electrodes for time-resolved measurements of electron cloud buildup
Authors:
James A. Crittenden,
Michael G. Billing,
Yulin Li,
Mark A. Palmer,
John P. Sikora
Abstract:
We report on the design, deployment and signal analysis for shielded button electrodes sensitive to electron cloud buildup at the Cornell Electron Storage Ring. These simple detectors, derived from a beam-position monitor electrode design, have provided detailed information on the physical processes underlying the local production and lifetime of electron densities in the storage ring. Digitizing…
▽ More
We report on the design, deployment and signal analysis for shielded button electrodes sensitive to electron cloud buildup at the Cornell Electron Storage Ring. These simple detectors, derived from a beam-position monitor electrode design, have provided detailed information on the physical processes underlying the local production and lifetime of electron densities in the storage ring. Digitizing oscilloscopes are used to record electron fluxes incident on the vacuum chamber wall in 1024 time steps of 100 ps or more. The fine time steps provide a detailed characterization of the cloud, allowing the independent estimation of processes contributing on differing time scales and providing sensitivity to the characteristic kinetic energies of the electrons making up the cloud. By varying the spacing and population of electron and positron beam bunches, we map the time development of the various cloud production and re-absorption processes. The excellent reproducibility of the measurements also permits the measurement of long-term conditioning of vacuum chamber surfaces.
△ Less
Submitted 24 March, 2014; v1 submitted 27 November, 2013;
originally announced November 2013.
-
Measurement of Electron Trapping in the CESR Storage Ring
Authors:
M. G. Billing,
J. Conway,
E. E. Cowan,
J. A. Crittenden,
W. Hartung,
J. Lanzoni,
Y. Li,
C. S. Shill,
J. P. Sikora,
K. G. Sonnad
Abstract:
The buildup of low-energy electrons has been shown to affect the performance of a wide variety of particle accelerators. Of particular concern is the persistence of the cloud between beam bunch passages, which can impose limitations on the stability of operation at high beam current. We have obtained measurements of long-lived electron clouds trapped in the field of a quadrupole magnet in a positr…
▽ More
The buildup of low-energy electrons has been shown to affect the performance of a wide variety of particle accelerators. Of particular concern is the persistence of the cloud between beam bunch passages, which can impose limitations on the stability of operation at high beam current. We have obtained measurements of long-lived electron clouds trapped in the field of a quadrupole magnet in a positron storage ring, with lifetimes much longer than the revolution period. Based on modeling, we estimate that about 7% of the electrons in the cloud generated by a 20-bunch train of 5.3 GeV positrons with 16-ns spacing and $1.3x10^{11}$ population survive longer than 2.3 $μ$s in a quadrupole field of gradient 7.4 T/m. We have observed a non-monotonic dependence of the trapping effect on the bunch spacing. The effect of a witness bunch on the measured signal provides direct evidence for the existence of trapped electrons. The witness bunch is also observed to clear the cloud, demonstrating its effectiveness as a mitigation technique.
△ Less
Submitted 6 March, 2015; v1 submitted 10 September, 2013;
originally announced September 2013.