-
The DAMIC-M Low Background Chamber
Authors:
I. Arnquist,
N. Avalos,
P. Bailly,
D. Baxter,
X. Bertou,
M. Bogdan,
C. Bourgeois,
J. Brandt,
A. Cadiou,
N. Castello-Mor,
A. E. Chavarria,
M. Conde,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
R. Desani,
M. Dhellot,
J. Duarte-Campderros,
E. Estrada,
D. Florin,
N. Gadola,
R. Gaior,
E. -L. Gkougkousis,
J. Gonzalez Sanchez
, et al. (45 additional authors not shown)
Abstract:
The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_χ$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sec…
▽ More
The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_χ$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.
△ Less
Submitted 25 July, 2024;
originally announced July 2024.
-
The JUNO experiment Top Tracker
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato
, et al. (592 additional authors not shown)
Abstract:
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector…
▽ More
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector, covering about 60% of the surface above them. The JUNO Top Tracker is constituted by the decommissioned OPERA experiment Target Tracker modules. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multianode photomultiplier tubes. Compared to the OPERA Target Tracker, the JUNO Top Tracker uses new electronics able to cope with the high rate produced by the high rock radioactivity compared to the one in Gran Sasso underground laboratory. This paper will present the new electronics and mechanical structure developed for the Top Tracker of JUNO along with its expected performance based on the current detector simulation.
△ Less
Submitted 9 March, 2023;
originally announced March 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
The DAMIC-M Experiment: Status and First Results
Authors:
I. Arnquist,
N. Avalos,
P. Bailly,
D. Baxter,
X. Bertou,
M. Bogdan,
C. Bourgeois,
J. Brandt,
A. Cadiou,
N. Castelló-Mor,
A. E. Chavarria,
M. Conde,
N. J. Corso,
J. Cortabitarte Gutiérrez,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
R. Desani,
M. Dhellot,
J-J. Dormard,
J. Duarte-Campderros,
E. Estrada,
D. Florin,
N. Gadola
, et al. (47 additional authors not shown)
Abstract:
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV…
▽ More
The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.
△ Less
Submitted 25 November, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection
Authors:
D. Norcini,
N. Castello-Mor,
D. Baxter,
N. J. Corso,
J. Cuevas-Zepeda,
C. De Dominicis,
A. Matalon,
S. Munagavalasa,
S. Paul,
P. Privitera,
K. Ramanathan,
R. Smida,
R. Thomas,
R. Yajur,
A. E. Chavarria,
K. McGuire,
P. Mitra,
A. Piers,
M. Settimo,
J. Cortabitarte Gutierrez,
J. Duarte-Campderros,
A. Lantero-Barreda,
A. Lopez-Virto,
I. Vila,
R. Vilar
, et al. (19 additional authors not shown)
Abstract:
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a…
▽ More
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $γ$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.
△ Less
Submitted 2 July, 2022;
originally announced July 2022.
-
Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (577 additional authors not shown)
Abstract:
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n…
▽ More
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.
△ Less
Submitted 13 October, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Mass Testing and Characterization of 20-inch PMTs for JUNO
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
Joao Pedro Athayde Marcondes de Andre,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli
, et al. (541 additional authors not shown)
Abstract:
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic…
▽ More
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).
△ Less
Submitted 17 September, 2022; v1 submitted 17 May, 2022;
originally announced May 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
The Double Chooz antineutrino detectors
Authors:
Double Chooz Collaboration,
H. de Kerret,
Y. Abe,
C. Aberle,
T. Abrahão,
J. M. Ahijado,
T. Akiri,
J. M. Alarcón,
J. Alba,
H. Almazan,
J. C. dos Anjos,
S. Appel,
F. Ardellier,
I. Barabanov,
J. C. Barriere,
E. Baussan,
A. Baxter,
I. Bekman,
M. Bergevin,
A. Bernstein,
W. Bertoli,
T. J. C. Bezerra,
L. Bezrukov,
C. Blanco,
N. Bleurvacq
, et al. (226 additional authors not shown)
Abstract:
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in th…
▽ More
This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.
△ Less
Submitted 13 September, 2022; v1 submitted 31 January, 2022;
originally announced January 2022.
-
Characterization of the background spectrum in DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
I. Arnquist,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
N. Corso,
E. Darragh-Ford,
M. L. Di Vacri,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan
, et al. (9 additional authors not shown)
Abstract:
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy…
▽ More
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk $^{3}$H from silicon cosmogenic activation and surface $^{210}$Pb from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as $3.1 \pm 0.6$ counts kg$^{-1}$ day$^{-1}$ keV$_{\text{ee}}^{-1}$, making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV$_{\text{ee}}$.
△ Less
Submitted 24 March, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld
, et al. (582 additional authors not shown)
Abstract:
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of…
▽ More
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
Mass production and characterization of 3-inch PMTs for the JUNO experiment
Authors:
Chuanya Cao,
Jilei Xu,
Miao He,
Angel Abusleme,
Mathieu Bongrand,
Clément Bordereau,
Dominique Breton,
Anatael Cabrera,
Agustin Campeny,
Cédric Cerna,
Haoqiang Chen,
Po-An Chen,
Gérard Claverie,
Selma Conforti Di Lorenzo,
Christophe De La Taille,
Frédéric Druillole,
Amélie Fournier,
Marco Grassi,
Xiaofei Gu,
Michael Haacke,
Yang Han,
Patrick Hellmuth,
Yuekun Heng,
Rafael Herrera,
Yee Hsiung
, et al. (42 additional authors not shown)
Abstract:
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was perf…
▽ More
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.
△ Less
Submitted 26 February, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
CATIROC: an integrated chip for neutrino experiments using photomultiplier tubes
Authors:
Selma Conforti,
Mariangela Settimo,
Cayetano Santos,
Clément Bordereau,
Anatael Cabrera,
Stéphane Callier,
Cédric Cerna,
Christophe De La Taille,
Frédéric Druillole,
Frédéric Dulucq,
Victor Lebrin,
Frédéric Lefèvre,
Gisèle Martin-Chassard,
Frédéric Perrot,
Abdel Rebii,
Louis-Marie Rigalleau,
Nathalie Seguin-Moreau
Abstract:
An ASIC named CATIROC (Charge And Time Integrated Read Out Chip) has been developed for the next-generation neutrino experiments using a large number of photomultiplier tubes (PMTs). Each CATIROC provides the time and the charge measurements for 16 configurable input channels operating in trigger-less mode. Originally designed for the light emission in water Cherenkov detectors, we show in this pa…
▽ More
An ASIC named CATIROC (Charge And Time Integrated Read Out Chip) has been developed for the next-generation neutrino experiments using a large number of photomultiplier tubes (PMTs). Each CATIROC provides the time and the charge measurements for 16 configurable input channels operating in trigger-less mode. Originally designed for the light emission in water Cherenkov detectors, we show in this paper that its use can be extended to liquid-scintillator based experiments. The $\sim$26000 3-inch PMTs of the JUNO experiment, under construction in China, is a case in point. This paper describes the features of CATIROC with a special attention to the most critical points for its application to the time profile of the light emission in liquid scintillators. The achieved performances in both charge and time measurements can be inputs for future high-precision experiments making use of PMTs or other photo-sensitive detectors.
△ Less
Submitted 12 May, 2021; v1 submitted 27 November, 2020;
originally announced December 2020.
-
Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis,
M. Settimo
, et al. (6 additional authors not shown)
Abstract:
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive conta…
▽ More
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive contamination of $^{32}$Si in the CCDs of $140 \pm 30$ $μ$Bq/kg, and place an upper limit on bulk $^{210}$Pb of $< 160~μ$Bq/kg. Using similar analyses of spatially-correlated bulk $α$ decays, we set limits of $< 11$ $μ$Bq/kg (0.9 ppt) on $^{238}$U and of $< 7.3$ $μ$Bq/kg (1.8 ppt) on $^{232}$Th. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from $^{32}$Si, has significant implications for the next generation of silicon-based dark matter experiments, where $β$'s from $^{32}$Si decay will likely be a dominant background. This capability demonstrates the readiness of the CCD technology to achieve kg-scale dark matter sensitivity.
△ Less
Submitted 23 July, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Calibration Strategy of the JUNO Experiment
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
Thilo Birkenfeld
, et al. (571 additional authors not shown)
Abstract:
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca…
▽ More
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.
△ Less
Submitted 20 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (572 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s…
▽ More
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Search for low-mass dark matter with the DAMIC experiment
Authors:
Mariangela Settimo
Abstract:
The DAMIC (Dark Matter in CCDs) experiment searches for the interactions of dark matter particles with the nuclei and the electrons in the silicon bulk of thick fully depleted charge-coupled devices (CCDs). Because of the low noise and low dark current, DAMIC CCDs are sensitive to the ionization signals expected from low-mass dark matter particles ($< 10$ GeV). A 40-gram target detector has collec…
▽ More
The DAMIC (Dark Matter in CCDs) experiment searches for the interactions of dark matter particles with the nuclei and the electrons in the silicon bulk of thick fully depleted charge-coupled devices (CCDs). Because of the low noise and low dark current, DAMIC CCDs are sensitive to the ionization signals expected from low-mass dark matter particles ($< 10$ GeV). A 40-gram target detector has collected data at the SNOLAB underground laboratory since 2017. Recent results from the searches for DM-electron scattering and hidden-photon absorption will be summarized and the status of WIMPs-nucleon search reported. A new detector -- DAMIC-M (DAMIC at Modane) -- with a mass-size of 1 kg and improved CCD readout is under design and will be installed at the underground laboratory of Modane, in France. The current status of DAMIC-M and the near future plans will be presented.
△ Less
Submitted 1 April, 2020; v1 submitted 20 March, 2020;
originally announced March 2020.
-
SoLid: A short baseline reactor neutrino experiment
Authors:
SoLid Collaboration,
Y. Abreu,
Y. Amhis,
L. Arnold,
G. Barber,
W. Beaumont,
S. Binet,
I. Bolognino,
M. Bongrand,
J. Borg,
D. Boursette,
V. Buridon,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupe,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
T. Durkin,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves
, et al. (37 additional authors not shown)
Abstract:
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino en…
▽ More
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration.
△ Less
Submitted 15 December, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
Combined sensitivity to the neutrino mass ordering with JUNO, the IceCube Upgrade, and PINGU
Authors:
IceCube-Gen2 Collaboration,
:,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
C. Alispach,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
C. Argüelles,
T. C. Arlen,
J. Auffenberg,
S. Axani,
P. Backes,
H. Bagherpour,
X. Bai,
A. Balagopal V.,
A. Barbano,
I. Bartos,
S. W. Barwick,
B. Bastian
, et al. (421 additional authors not shown)
Abstract:
The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscill…
▽ More
The ordering of the neutrino mass eigenstates is one of the fundamental open questions in neutrino physics. While current-generation neutrino oscillation experiments are able to produce moderate indications on this ordering, upcoming experiments of the next generation aim to provide conclusive evidence. In this paper we study the combined performance of the two future multi-purpose neutrino oscillation experiments JUNO and the IceCube Upgrade, which employ two very distinct and complementary routes towards the neutrino mass ordering. The approach pursued by the $20\,\mathrm{kt}$ medium-baseline reactor neutrino experiment JUNO consists of a careful investigation of the energy spectrum of oscillated $\barν_e$ produced by ten nuclear reactor cores. The IceCube Upgrade, on the other hand, which consists of seven additional densely instrumented strings deployed in the center of IceCube DeepCore, will observe large numbers of atmospheric neutrinos that have undergone oscillations affected by Earth matter. In a joint fit with both approaches, tension occurs between their preferred mass-squared differences $ Δm_{31}^{2}=m_{3}^{2}-m_{1}^{2} $ within the wrong mass ordering. In the case of JUNO and the IceCube Upgrade, this allows to exclude the wrong ordering at $>5σ$ on a timescale of 3--7 years --- even under circumstances that are unfavorable to the experiments' individual sensitivities. For PINGU, a 26-string detector array designed as a potential low-energy extension to IceCube, the inverted ordering could be excluded within 1.5 years (3 years for the normal ordering) in a joint analysis.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
V. B. B. Mello,
P. Mitra,
Y. S. Mobarak,
J. Molina,
S. Paul,
A. Piers,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attribute…
▽ More
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with masses in the range $1.2$-$30$ eV$c^{-2}$.
△ Less
Submitted 8 April, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Commissioning and Operation of the Readout System for the SoLid Neutrino Detector
Authors:
Y. Abreu,
Y. Amhis,
G. Ban,
W. Beaumont,
S. Binet,
M. Bongrand,
D. Boursette,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupé,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order…
▽ More
The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80x80x250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.
△ Less
Submitted 31 August, 2019; v1 submitted 13 December, 2018;
originally announced December 2018.
-
Development of a Quality Assurance Process for the SoLid Experiment
Authors:
Y. Abreu,
Y. Amhis,
G. Ban,
W. Beaumont,
S. Binet,
M. Bongrand,
D. Boursette,
B. C. Castle,
H. Chanal,
K. Clark,
B. Coupé,
P. Crochet,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sh…
▽ More
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $\overlineν_e$ target for the inverse beta decay of ($\overlineν_e + p \rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $\mathcal{O}$(10)\% in the energy spectrum of reactor $\overlineν_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 \% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.
△ Less
Submitted 20 December, 2018; v1 submitted 13 November, 2018;
originally announced November 2018.
-
Optimisation of the scintillation light collection and uniformity for the SoLid experiment
Authors:
Y. Abreu,
Y. Amhis,
W. Beaumont,
M. Bongrand,
D. Boursette,
B. C. Castle,
K. Clark,
B. Coupé,
D. Cussans,
A. De Roeck,
D. Durand,
M. Fallot,
L. Ghys,
L. Giot,
K. Graves,
B. Guillon,
D. Henaff,
B. Hosseini,
S. Ihantola,
S. Jenzer,
S. Kalcheva,
L. N. Kalousis,
M. Labare,
G. Lehaut,
S. Manley
, et al. (26 additional authors not shown)
Abstract:
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires hi…
▽ More
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires high light yield of the scintillating elements and uniformity of the response in the detector volume. The SoLid experiment uses an innovative hybrid technology with two different scintillators: polyvinyltoluene scintillator cubes and $^6$LiF:ZnS(Ag) screens. A precision test bench based on a $^{207}$Bi calibration source has been developed to study improvements on the energy resolution and uniformity of the prompt scintillation signal of antineutrino interactions. A trigger system selecting the 1~MeV conversion electrons provides a Gaussian energy peak and allows for precise comparisons of the different detector configurations that were considered to improve the SoLid detector light collection. The light collection efficiency is influenced by the choice of wrapping material, the position of the $^6$LiF:ZnS(Ag) screen, the type of fibre, the number of optical fibres and the type of mirror at the end of the fibre. This study shows that large gains in light collection efficiency are possible compared to the SoLid SM1 prototype. The light yield for the SoLid detector is expected to be at least 52$\pm$2 photo-avalanches per MeV per cube, with a relative non-uniformity of 6 %, demonstrating that the required energy resolution of at least 14 % at 1 MeV can be achieved.
△ Less
Submitted 7 September, 2018; v1 submitted 6 June, 2018;
originally announced June 2018.
-
Yields and production rates of cosmogenic $^9$Li and $^8$He measured with the Double Chooz near and far detectors
Authors:
H. de Kerret,
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
J. C. Barriere,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
D. Franco,
H. Furuta,
I. Gil-Botella,
A. Givaudan
, et al. (73 additional authors not shown)
Abstract:
The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresp…
▽ More
The yields and production rates of the radioisotopes $^9$Li and $^8$He created by cosmic muon spallation on $^{12}$C, have been measured by the two detectors of the Double Chooz experiment. The identical detectors are located at separate sites and depths, which means they are subject to different muon spectra. The near (far) detector has an overburden of $\sim$120 m.w.e. ($\sim$300 m.w.e.) corresponding to a mean muon energy of $32.1\pm2.0\,\mathrm{GeV}$ ($63.7\pm5.5\,\mathrm{GeV}$). Comparing the data to a detailed simulation of the $^9$Li and $^8$He decays, the contribution of the $^8$He radioisotope at both detectors is found to be compatible with zero. The observed $^9$Li yields in the near and far detectors are $5.51\pm0.51$ and $7.90\pm0.51$, respectively, in units of $10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2} }$. The shallow overburdens of the near and far detectors give a unique insight when combined with measurements by KamLAND and Borexino to give the first multi--experiment, data driven relationship between the $^9$Li yield and the mean muon energy according to the power law $Y = Y_0( <E_μ >/ 1\,\mathrm{GeV})^{\overlineα}$, giving $\overlineα=0.72\pm0.06$ and $Y_0=(0.43\pm0.11)\times 10^{-8}μ^{-1} \mathrm{g^{-1} cm^{2}}$. This relationship gives future liquid scintillator based experiments the ability to predict their cosmogenic $^9$Li background rates.
△ Less
Submitted 10 October, 2018; v1 submitted 22 February, 2018;
originally announced February 2018.
-
Novel event classification based on spectral analysis of scintillation waveforms in Double Chooz
Authors:
T. Abrahão,
H. Almazan,
J. C. dos Anjos,
S. Appel,
I. Bekman,
T. J. C. Bezerra,
L. Bezrukov,
E. Blucher,
T. Brugière,
C. Buck,
J. Busenitz,
A. Cabrera,
L. Camilleri,
M. Cerrada,
E. Chauveau,
P. Chimenti,
O. Corpace,
J. I. Crespo-Anadón,
J. V. Dawson,
Z. Djurcic,
A. Etenko,
M. Fallot,
D. Franco,
H. Furuta,
I. Gil-Botella
, et al. (72 additional authors not shown)
Abstract:
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implemen…
▽ More
Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a novel approach for a pulse shape based event classification developed in the context of the Double Chooz reactor antineutrino experiment. Unlike previous implementations, this method uses the Fourier power spectra of the scintillation pulse shapes to obtain event-wise information. A classification variable built from spectral information was able to achieve an unprecedented performance, despite the lack of optimization at the detector design level. Several examples of event classification are provided, ranging from differentiation between the detector volumes and an efficient rejection of instrumental light noise, to some sensitivity to the particle type, such as stopping muons, ortho-positronium formation, alpha particles as well as electrons and positrons. In combination with other techniques the method is expected to allow for a versatile and more efficient background rejection in the future, especially if detector optimization is taken into account at the design level.
△ Less
Submitted 18 January, 2018; v1 submitted 11 October, 2017;
originally announced October 2017.
-
Muon Counting using Silicon Photomultipliers in the AMIGA detector of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu
, et al. (400 additional authors not shown)
Abstract:
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is com…
▽ More
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m$^2$ detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98 % efficiency for the highest tested overvoltage, combined with a low probability of accidental counting ($\sim$2 %), show a promising performance for this new system.
△ Less
Submitted 4 October, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.
-
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guandincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
J. Molina,
J. R. Peña,
P. Privitera
, et al. (13 additional authors not shown)
Abstract:
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic…
▽ More
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
△ Less
Submitted 9 November, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin
, et al. (429 additional authors not shown)
Abstract:
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary…
▽ More
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. The completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.
△ Less
Submitted 12 May, 2016; v1 submitted 5 May, 2016;
originally announced May 2016.
-
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila
, et al. (426 additional authors not shown)
Abstract:
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected…
▽ More
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a "beacon transmitter" which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.
△ Less
Submitted 15 February, 2016; v1 submitted 7 December, 2015;
originally announced December 2015.
-
The Pierre Auger Observatory V: Enhancements
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Ongoing and planned enhancements of the Pierre Auger Observatory
Ongoing and planned enhancements of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.
-
The Pierre Auger Observatory IV: Operation and Monitoring
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (471 additional authors not shown)
Abstract:
Technical reports on operations and monitoring of the Pierre Auger Observatory
Technical reports on operations and monitoring of the Pierre Auger Observatory
△ Less
Submitted 24 July, 2011;
originally announced July 2011.