-
Multi-objective shape optimization of radio frequency cavities using an evolutionary algorithm
Authors:
Marija Kranjcevic,
Andreas Adelmann,
Peter Arbenz,
Alessandro Citterio,
Lukas Stingelin
Abstract:
Radio frequency (RF) cavities are commonly used to accelerate charged particle beams. The shape of the RF cavity determines the resonant electromagnetic fields and frequencies, which need to satisfy a variety of requirements for a stable and efficient acceleration of the beam. For example, the accelerating frequency has to match a given target frequency, the shunt impedance usually has to be maxim…
▽ More
Radio frequency (RF) cavities are commonly used to accelerate charged particle beams. The shape of the RF cavity determines the resonant electromagnetic fields and frequencies, which need to satisfy a variety of requirements for a stable and efficient acceleration of the beam. For example, the accelerating frequency has to match a given target frequency, the shunt impedance usually has to be maximized, and the interaction of higher order modes with the beam minimized. In this paper we formulate such problems as constrained multi-objective shape optimization problems, use a massively parallel implementation of an evolutionary algorithm to find an approximation of the Pareto front, and employ a penalty method to deal with the constraint on the accelerating frequency. Considering vacuated axisymmetric RF cavities, we parameterize and mesh their cross section and then solve time-harmonic Maxwell's equations with perfectly electrically conducting boundary conditions using a fast 2D Maxwell eigensolver. The specific problem we focus on is the hypothetical problem of optimizing the shape of the main RF cavity of the planned upgrade of the Swiss Synchrotron Light Source (SLS), called SLS-2. We consider different objectives and geometry types and show the obtained results, i.e. the computed Pareto front approximations and the RF cavity shapes with desired properties. Finally, we compare these newfound cavity shapes with the current cavity of SLS.
△ Less
Submitted 15 March, 2019; v1 submitted 6 October, 2018;
originally announced October 2018.
-
Calculation of Longitudinal Collective Instabilities with mbtrack-cuda
Authors:
Haisheng Xu,
Uldis Locans,
Andreas Adelmann,
Lukas Stingelin
Abstract:
Macro-particle tracking is a prominent method to study the collective beam instabilities in accelerators. However, the heavy computation load often limits the capability of the tracking codes. One widely used macro-particle tracking code to simulate collective instabilities in storage rings is mbtrack. The Message Passing Interface (MPI) is already implemented in the original mbtrack to accelerate…
▽ More
Macro-particle tracking is a prominent method to study the collective beam instabilities in accelerators. However, the heavy computation load often limits the capability of the tracking codes. One widely used macro-particle tracking code to simulate collective instabilities in storage rings is mbtrack. The Message Passing Interface (MPI) is already implemented in the original mbtrack to accelerate the simulations. However, many CPU threads are requested in mbtrack for the analysis of the coupled-bunch instabilities. Therefore, computer clusters or desktops with many CPU cores are needed. Since these are not always available, we employ as alternative a Graphics Processing Unit (GPU) with CUDA programming interface to run such simulations in a stand-alone workstation. All the heavy computations have been moved to the GPU. The benchmarks confirm that mbtrack-cuda can be used to analyze coupled bunch instabilities up to at least 484 bunches. Compared to mbtrack on an 8-core CPU, 36-core CPU and a cluster, mbtrack-cuda is faster for simulations of up to 3 bunches. For 363 bunches, mbtrack-cuda needs about six times the execution time of the cluster and twice of the 36-core CPU. The multi-bunch instability analysis shows that the length of the ion-cleaning gap has no big influence, at least at filling to 3/4.
△ Less
Submitted 2 September, 2018;
originally announced September 2018.
-
Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility
Authors:
T. Schietinger,
M. Pedrozzi,
M. Aiba,
V. Arsov,
S. Bettoni,
B. Beutner,
M. Calvi,
P. Craievich,
M. Dehler,
F. Frei,
R. Ganter,
C. P. Hauri,
R. Ischebeck,
Y. Ivanisenko,
M. Janousch,
M. Kaiser,
B. Keil,
F. Löhl,
G. L. Orlandi,
C. Ozkan Loch,
P. Peier,
E. Prat,
J. -Y. Raguin,
S. Reiche,
T. Schilcher
, et al. (70 additional authors not shown)
Abstract:
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chican…
▽ More
The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.
△ Less
Submitted 27 October, 2016; v1 submitted 8 June, 2016;
originally announced June 2016.
-
Examination of the Plasma located in PSI Ring Cyclotron
Authors:
Nathaniel Pogue,
Andreas Adelmann,
Markus Schneider,
Lukas Stingelin
Abstract:
A plasma has been observed inside the vacuum chamber of the PSI Ring Cyclotron. This ionized gas cloud maybe a substantial contributor to several interior components having reduced lifetimes. The plasma's generation has been directly linked to the voltage that is applied to the Flat Top Cavity through visual confirmation using CCD cameras. A spectrometer was used to correlate the plasma's intensit…
▽ More
A plasma has been observed inside the vacuum chamber of the PSI Ring Cyclotron. This ionized gas cloud maybe a substantial contributor to several interior components having reduced lifetimes. The plasma's generation has been directly linked to the voltage that is applied to the Flat Top Cavity through visual confirmation using CCD cameras. A spectrometer was used to correlate the plasma's intensity and ignition to the Flat Top Cavity voltage as well as to determine the composition of the plasma. This paper reports on the analysis of the plasma using spectroscopy. The spectrometer data was analyzed to determine the composition of the plasma and that the plasma intensity (luminosity) directly corresponds to the Flat Top voltage. The results showed that the plasma was comprised of elements consistent with the cyclotrons vacuum interior
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Analysis and Suppression of RF Radiation from the PSI 590MeV Cyclotron Flat Top Cavity
Authors:
Nathaniel Pogue,
Andreas Adelman,
Lukas Stingelin
Abstract:
The Flat Top Cavity, located in the PSI HIPA Ring Cyclotron leaks RF power of several kilo Watts into the cyclotrons vacuum space causing several complications. A detailed electromagnetic model was created and simulations performed to analyze the mechanisms by which power is leaking out of the Flat Top Cavity. The tolerances needed to limit the leaked power in future iterations of the Flat Top cav…
▽ More
The Flat Top Cavity, located in the PSI HIPA Ring Cyclotron leaks RF power of several kilo Watts into the cyclotrons vacuum space causing several complications. A detailed electromagnetic model was created and simulations performed to analyze the mechanisms by which power is leaking out of the Flat Top Cavity. The tolerances needed to limit the leaked power in future iterations of the Flat Top cavity are reported. Comparison of the model to measurements are described as well as two potential methods to limit power leakage. These studies will have direct impact on future RF cavity designs for cyclotrons as power levels increase and higher RF fields are required.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Multimegawatt DAE$δ$ALUS Cyclotrons for Neutrino Physics
Authors:
M. Abs,
A. Adelmann,
J. R. Alonso,
W. A. Barletta,
R. Barlow,
L. Calabretta,
A. Calanna,
D. Campo,
L. Celona,
J. M. Conrad,
S. Gammino,
W. Kleeven,
T. Koeth,
M. Maggiore,
H. Okuno,
L. A. C. Piazza,
M. Seidel,
M. H. Shaevitz,
L. Stingelin,
J. J. Yang,
J. Yeck
Abstract:
DAE$δ$ALUS (Decay-At-rest Experiment for $δ_{CP}$ studies At the Laboratory for Underground Science) provides a new approach to the search for CP violation in the neutrino sector. High-power continuous-wave proton cyclotrons efficiently provide the necessary proton beams with an energy of up to 800 MeV to create neutrinos from pion and muon decay-at-rest. The experiment searches for…
▽ More
DAE$δ$ALUS (Decay-At-rest Experiment for $δ_{CP}$ studies At the Laboratory for Underground Science) provides a new approach to the search for CP violation in the neutrino sector. High-power continuous-wave proton cyclotrons efficiently provide the necessary proton beams with an energy of up to 800 MeV to create neutrinos from pion and muon decay-at-rest. The experiment searches for $\barν_μ \rightarrow \barν_e$ at short baselines corresponding to the atmospheric $Δm^2$ region. The $\barν_e$ will be detected via inverse beta decay. Thus, the cyclotrons will be employed at a future ultra-large gadolinium-doped water or scintillator detector. In this paper we address the most challenging questions regarding a cyclotron-based high-power proton driver in the megawatt range with a kinetic energy of 800 MeV. Aspects of important subsystems like the ion source and injection chain, the magnet design and radio frequency system will be addressed. Precise beam dynamics simulations, including space charge and the $\text{H}_2^+$ stripping process, are the base for the characterization and quantification of the beam halo -- one of the most limiting processes in high-power particle accelerators.
△ Less
Submitted 1 August, 2012; v1 submitted 20 July, 2012;
originally announced July 2012.
-
Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources
Authors:
Paul Indelicato,
S. Boucard,
D. S. Covita,
D. Gotta,
A. Gruber,
A. Hirtl,
H. Fuhrmann,
E. -O. Le Bigot,
S. Schlesser,
J. M. F. Dos Santos,
L. M. Simons,
L. Stingelin,
M. Trassinelli,
J. Veloso,
A. Wasser,
J. Zmeskal
Abstract:
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show ho…
▽ More
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show how these measurement can test sensitively many-body relativistic calculations or can be used as X-ray standards for precise measurements of X-ray transitions in exotic atoms.
△ Less
Submitted 28 October, 2006;
originally announced October 2006.
-
High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT
Authors:
Martino Trassinelli,
Sandor Biri,
Stephane Boucard,
Daniel S. Covita,
Detlev Gotta,
Bruno Leoni,
Albert Hirtl,
Paul Indelicato,
Eric-Olivier Le Bigot,
Joaquim M. F. Dos Santos,
Leopold M. Simons,
Lucas Stingelin,
Joao F. C. A. Veloso,
Alfred Wasser,
Johann Zmeskal
Abstract:
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct…
▽ More
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconducting split coil magnet, special iron inserts which provides the mirror field, and a permanent magnetic hexapole. The high frequency was provided by a 6.4 GHz microwave emitter. We obtained high intensity X-ray spectra of multicharged F-like to He-like argon, sulfur and chlorine with one 1s hole. In particular, we observed the $1s2s^{3}S_1 \to 1s^2^{1}S_0 M1$ and $1s2p^{3}P_2 \to 1s^2^{1}S_0 M2$ transitions in He-like argon, sulfur and chlorine with unprecedented statistics and resolution. The energies of the observed lines are being determined with good accuracy using the He-like M1 line as a reference.
△ Less
Submitted 26 October, 2004;
originally announced October 2004.
-
On the characterisation of a Bragg spectrometer with X-rays from an ECR source
Authors:
D. F. Anagnostopoulos,
S. Biri,
D. Gotta,
A. Gruber,
Paul Indelicato,
B. Leoni,
H. Fuhrmann,
L. M. Simons,
L. Stingelin,
A. Wasser,
J. Zmeskal
Abstract:
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and th…
▽ More
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and the geometry of the experimental set-up.
△ Less
Submitted 23 December, 2004; v1 submitted 18 August, 2004;
originally announced August 2004.