-
Al/Ti/Al phonon-mediated KIDs for UV-VIS light detection over large areas
Authors:
L. Cardani,
N. Casali,
A. Cruciani,
H. le Sueur,
M. Martinez,
F. Bellini,
M. Calvo,
M. G. Castellano,
I. Colantoni,
C. Cosmelli,
A. D'Addabbo,
S. Di Domizio,
J. Goupy,
L. Minutolo,
A. Monfardini,
M. Vignati
Abstract:
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their…
▽ More
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their well-established reproducibility, Kinetic Inductance Detectors (KIDs) are good candidates for the development of next generation light detectors. The CALDER project is investigating the potential of phonon-mediated KIDs. The first phase of the project allowed to reach a baseline resolution of 80 eV using a single KID made of aluminium on a 2x2 cm\tmrsup{$2$} silicon substrate acting as photon absorber. In this paper we present a new prototype detector implementing a trilayer aluminium-titanium-aluminium KID. Taking advantage of the superconducting proximity effect the baseline resolution improves down to 26 eV.
△ Less
Submitted 27 April, 2018; v1 submitted 25 January, 2018;
originally announced January 2018.
-
Complete event-by-event $α$/$γ(β)$ separation in a full-size TeO$_2$ CUORE bolometer by Neganov-Luke-magnified light detection
Authors:
L. Bergé,
M. Chapellier,
M. de Combarieu,
L. Dumoulin,
A. Giuliani,
M. Gros,
P. de Marcillac,
S. Marnieros,
C. Nones,
V. Novati,
E. Olivieri,
B. Paul,
D. V. Poda,
T. Redon,
B. Siebenborn,
A. S. Zolotarova,
E. Armengaud,
C. Augier,
A. Benoît,
J. Billard,
A. Broniatowski,
P. Camus,
A. Cazes,
F. Charlieux,
M. De Jesus
, et al. (19 additional authors not shown)
Abstract:
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0νββ$) of $^{130}$Te. We demonstrate an efficient $α$ particle discrimination (99.9\%) with a high acceptance of the $0νββ$ signal (about 96\%), expected at $\approx 2.5$ MeV. This unprecedented result was possible thanks to the s…
▽ More
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0νββ$) of $^{130}$Te. We demonstrate an efficient $α$ particle discrimination (99.9\%) with a high acceptance of the $0νββ$ signal (about 96\%), expected at $\approx 2.5$ MeV. This unprecedented result was possible thanks to the superior performance (10 eV rms baseline noise) of a Neganov-Luke-assisted germanium bolometer used to detect a tiny (70 eV) light signal from the TeO$_2$ detector, dominated by $γ$($β$)-induced Cherenkov radiation but exhibiting also a clear scintillation component. The obtained results represent a major breakthrough towards the TeO$_2$-based version of CUORE Upgrade with Particle IDentification (CUPID), a ton-scale cryogenic $0νββ$ experiment proposed as a follow-up to the CUORE project with particle identification. The CUORE experiment began recently a search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 125-cm$^3$ TeO$_2$ bolometers. The lack of $α$ discrimination in CUORE makes $α$ decays at the detector surface the dominant background component, at the level of $\approx 0.01$ counts/(keV kg y) in the region of interest. We show here, for the first time with a CUORE-size bolometer and using the same technology as CUORE for the readout of both heat and light signals, that surface $α$ background can be fully rejected.
△ Less
Submitted 25 April, 2018; v1 submitted 10 October, 2017;
originally announced October 2017.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO$_4$ scintillating bolometers
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
A. Benoit,
L. Berge,
R. S. Boiko,
T. Bergmann,
J. Blumer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
F. A. Danevich,
T. de Boissiere,
R. Decourt,
M. De Jesus,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin
, et al. (69 additional authors not shown)
Abstract:
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very prom…
▽ More
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very promising for the recognition and rejection of background events. We present the LUMINEU concepts and the experimental results achieved aboveground and underground with large-mass natural and enriched crystals. The measured energy resolution, the $α/β$ discrimination power and the radioactive internal contamination are all within the specifications for the projected final LUMINEU sensitivity. Simulations and preliminary results confirm that the LUMINEU technology can reach zero background in the region of interest (around 3 MeV) with exposures of the order of hundreds kg$\times$years, setting the bases for a next generation $0\nu2β$ decay experiment capable to explore the inverted hierarchy region of the neutrino mass pattern.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Scintillating bolometers based on ZnMoO$_4$ and Zn$^{100}$MoO$_4$ crystals to search for 0$ν$2$β$ decay of $^{100}$Mo (LUMINEU project): first tests at the Modane Underground Laboratory
Authors:
D. V. Poda,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
R. S. Boiko,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
B. Censier,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
G. A. Cox,
F. A. Danevich,
T. de Boissière,
R. Decourt,
M. De Jesus
, et al. (69 additional authors not shown)
Abstract:
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed…
▽ More
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed and Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time by using the low-thermal-gradient Czochralski technique. One ZnMoO$_4$ scintillator and two samples (59 g and 63 g) cut from the enriched boule were tested aboveground at milli-Kelvin temperature as scintillating bolometers showing a high detection performance. The first results of the low background measurements with three ZnMoO$_4$ and two enriched detectors installed in the EDELWEISS set-up at the Modane Underground Laboratory (France) are presented.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
Background studies for the EDELWEISS dark matter experiment
Authors:
E. Armengaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couedo,
P. Coulter,
G. A. Cox,
M. De Jesus,
J. Domange,
A. -A. Drilien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
M. Gros
, et al. (34 additional authors not shown)
Abstract:
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present h…
▽ More
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg$\times$days of effective exposure. A cross-section of $4.4 \times 10^{-8}$ pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few $\times10^{-9}$ pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of 1.0-3.1 events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events ($\le0.9$), surface betas ($\le0.3$), and muon-induced neutrons ($\le0.7$), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as 14-44 events/kg/day and 0.7-1.4 events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected rate of background events in the next phase of the experiment.
△ Less
Submitted 15 May, 2013;
originally announced May 2013.
-
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
Authors:
EDELWEISS Collaboration,
E. Armengaud,
C. Augier,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
B. Censier,
M. Chapellier,
F. Charlieux,
F. Couëdo,
P. Coulter,
G. A. Cox,
J. Domange,
A. A. Drillien,
L. Dumoulin,
K. Eitel,
D. Filosofov,
N. Fourches,
J. Gascon,
G. Gerbier,
J. Gironnet,
M. Gros
, et al. (30 additional authors not shown)
Abstract:
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed…
▽ More
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.
△ Less
Submitted 5 September, 2012; v1 submitted 7 July, 2012;
originally announced July 2012.
-
Room-temperature tunnel current amplifier and experimental setup for high resolution electronic spectroscopy in millikelvin STM experiments
Authors:
H. Le Sueur,
P. Joyez
Abstract:
The spectroscopic resolution of tunneling measurements performed with a scanning tunneling microscope is ultimately limited by the temperature at which the experiment is performed. To take advantage of the potential high spectroscopic resolution associated with operating an STM in a dilution refrigerator we have designed a room temperature tunnel current amplifier having very small back-action o…
▽ More
The spectroscopic resolution of tunneling measurements performed with a scanning tunneling microscope is ultimately limited by the temperature at which the experiment is performed. To take advantage of the potential high spectroscopic resolution associated with operating an STM in a dilution refrigerator we have designed a room temperature tunnel current amplifier having very small back-action on the tunnel contact and allowing to nearly reach the predicted energy resolution. This design is a modification of the standard op-amp based tip-biasing current-voltage converter which implements differential voltage sensing and whose back action on the tip voltage is only ~2 $μ$V rms for a 14 MV/A transimpedance and 22 kHz bandwidth.
△ Less
Submitted 3 January, 2007; v1 submitted 31 October, 2006;
originally announced October 2006.
-
Micro-fabricated electromagnetic filters for millikelvin experiments
Authors:
H. Le Sueur,
P. Joyez
Abstract:
In this article we report on the design, fabrication and tests of micro-fabricated broadband filters suitable for proper electromagnetic thermalization of electrical lines connected to sensitive quantum electronics experiments performed at dilution fridge temperatures. Compared to previous such miniature filters, the new design improves on performance and reliability. These filters can be packed…
▽ More
In this article we report on the design, fabrication and tests of micro-fabricated broadband filters suitable for proper electromagnetic thermalization of electrical lines connected to sensitive quantum electronics experiments performed at dilution fridge temperatures. Compared to previous such miniature filters, the new design improves on performance and reliability. These filters can be packed in space-saving cases with either single or multi-contact connectors. Measured performance in the accessible range compares well to simulations. We use these simulations to discuss the effectiveness of these filters for electromagnetic thermalization at 30 mK.
△ Less
Submitted 3 January, 2007; v1 submitted 31 October, 2006;
originally announced October 2006.