-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Machine-Learning based photon counting for PMT waveforms and its application to the improvement of the energy resolution in large liquid scintillator detectors
Authors:
Wei Jiang,
Guihong Huang,
Zhen Liu,
Wuming Luo,
Liangjian Wen,
Jianyi Luo
Abstract:
Photomultiplier tubes (PMTs) are widely used in particle experiments for photon detection. PMT waveform analysis is crucial for high-precision measurement of the position and energy of incident particles in liquid scintillator (LS) detectors. A key factor contributing to the energy resolution in large liquid scintillator detectors with PMTs is the charge smearing of PMTs. This paper presents a mac…
▽ More
Photomultiplier tubes (PMTs) are widely used in particle experiments for photon detection. PMT waveform analysis is crucial for high-precision measurement of the position and energy of incident particles in liquid scintillator (LS) detectors. A key factor contributing to the energy resolution in large liquid scintillator detectors with PMTs is the charge smearing of PMTs. This paper presents a machine-learning-based photon counting method for PMT waveforms and its application to the energy reconstruction, using the JUNO experiment as an example. The results indicate that leveraging the photon counting information from the machine learning model can partially mitigate the impact of PMT charge smearing and lead to a relative 2.0% to 2.8% improvement on the energy resolution at different energies.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
A practical approach of measuring $^{238}$U and $^{232}$Th in liquid scintillator to sub-ppq level using ICP-MS
Authors:
Yuanxia Li,
Jie Zhao,
Yayun Ding,
Tao Hu,
Jiaxuan Ye,
Jian Fang,
Liangjian Wen
Abstract:
Liquid scintillator (LS) is commonly utilized in experiments seeking rare events due to its high light yield, transparency, and radiopurity. The concentration of $^{238}$U and $^{232}$Th in LS consistently remains below 1 ppq (10$^{-15}$ g/g), and the current screening result is based on a minimum 20-ton detector. Inductively coupled plasma mass (ICP-MS) spectroscopy is well-regarded for its high…
▽ More
Liquid scintillator (LS) is commonly utilized in experiments seeking rare events due to its high light yield, transparency, and radiopurity. The concentration of $^{238}$U and $^{232}$Th in LS consistently remains below 1 ppq (10$^{-15}$ g/g), and the current screening result is based on a minimum 20-ton detector. Inductively coupled plasma mass (ICP-MS) spectroscopy is well-regarded for its high sensitivity to trace $^{238}$U and $^{232}$Th. This study outlines a method for detecting $^{238}$U and $^{232}$Th in LS at the sub-ppq level using ICP-MS, involving the enrichment of $^{238}$U/$^{232}$Th from the LS through acid extraction. With meticulous cleanliness control, $^{238}$U/$^{232}$Th in approximately 2 kg of LS is concentrated by acid extraction with 0.4 (0.3) pg $^{238}$U ($^{232}$Th) contamination. Three standard adding methods are employed to assess recovery efficiency, including radon daughter, 2,5-diphenyloxazole (PPO), and natural non-existent $^{233}$U/$^{229}$Th. The method detection limit at a 99% confidence level of this approach can reach approximately 0.2-0.3 ppq for $^{238}$U/$^{232}$Th with nearly 100% recovery efficiency.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
Environmental radon control in the 700-m underground laboratory at JUNO
Authors:
Chenyang Cui,
Jie Zhao,
Gaosong Li,
Yongpeng Zhang,
Cong Guo,
Zhenning Qu,
Yifang Wang,
Xiaonan Li,
Liangjian Wen,
Miao He,
Monica Sisti
Abstract:
The Jiangmen Underground Neutrino Observatory is building the world's largest liquid scintillator detector with a 20 kt target mass and about 700 m overburden. The total underground space of civil construction is about 300,000 m$^3$ with the main hall volume of about 120,000 m$^3$, which is the biggest laboratory in the world. Radon concentration in the underground air is quite important for not o…
▽ More
The Jiangmen Underground Neutrino Observatory is building the world's largest liquid scintillator detector with a 20 kt target mass and about 700 m overburden. The total underground space of civil construction is about 300,000 m$^3$ with the main hall volume of about 120,000 m$^3$, which is the biggest laboratory in the world. Radon concentration in the underground air is quite important for not only human beings' health but also the background of experiments with rare decay detection, such as neutrino and dark matter experiments. The radon concentration is the main hall is required to be around 100 Bq/m$^3$. Optimization of the ventilation with fresh air is effective to control the radon underground. To find the radon sources in the underground laboratory, we made a benchmark experiment in the refuge room near the main hall. The result shows that the radon emanating from underground water is one of the main radon sources in the underground air. The total underground ventilation rate is about 160,000 m$^3$/h fresh air with about 30 Bq/m$^3$ $^{222}$Rn from the bottom of the vertical tunnel after optimization, and 55,000 m$^3$/h is used for the ventilation in the main hall. Finally, the radon concentration inside the main hall decreased from 1600 Bq/m$^3$ to around 100 Bq/m$^3$. The suggested strategies for controlling radon concentration in the underground air are described in this paper.
△ Less
Submitted 12 September, 2023;
originally announced September 2023.
-
Design of the offline test electronics for the nozzle system of proton therapy
Authors:
Peng Huang,
Zhiguo Yin,
Tianjian Bian,
Shigang Hou,
Yang Wang,
Tianjue Zhang,
Luyu Ji,
Lipeng Wen,
Xueer Mu,
Rui Xiong
Abstract:
A set of nozzle equipment for proton therapy is now being developed at China Institute of Atomic Energy. To facilitate the off-line commissioning of the whole equipment, a set of ionization chamber signal generation system, the test electronics, is designed. The system uses ZYNQ SoC as the main control unit and outputs the beam dose analog signal through DAC8532. The dual SPDT analog switch, DG636…
▽ More
A set of nozzle equipment for proton therapy is now being developed at China Institute of Atomic Energy. To facilitate the off-line commissioning of the whole equipment, a set of ionization chamber signal generation system, the test electronics, is designed. The system uses ZYNQ SoC as the main control unit and outputs the beam dose analog signal through DAC8532. The dual SPDT analog switch, DG636, is used to simulate the beam position signals according to Gaussian distribution. The results show that the system can simulate the beam position, dose, and other related analog signals generated by the proton beam when passing through the ionization chamber. Moreover, the accuracy of the simulated beam position is within +/-0.33mm, and the accuracy of the simulated dose signal is within +/-1%. At the same time, it can output analog signals representing environmental parameters. The test electronics meets the design requirements, which can be used to commission the nozzle system as well as the treatment control system without the proton beam.
△ Less
Submitted 21 July, 2023;
originally announced July 2023.
-
DiffDP: Radiotherapy Dose Prediction via a Diffusion Model
Authors:
Zhenghao Feng,
Lu Wen,
Peng Wang,
Binyu Yan,
Xi Wu,
Jiliu Zhou,
Yan Wang
Abstract:
Currently, deep learning (DL) has achieved the automatic prediction of dose distribution in radiotherapy planning, enhancing its efficiency and quality. However, existing methods suffer from the over-smoothing problem for their commonly used L_1 or L_2 loss with posterior average calculations. To alleviate this limitation, we innovatively introduce a diffusion-based dose prediction (DiffDP) model…
▽ More
Currently, deep learning (DL) has achieved the automatic prediction of dose distribution in radiotherapy planning, enhancing its efficiency and quality. However, existing methods suffer from the over-smoothing problem for their commonly used L_1 or L_2 loss with posterior average calculations. To alleviate this limitation, we innovatively introduce a diffusion-based dose prediction (DiffDP) model for predicting the radiotherapy dose distribution of cancer patients. Specifically, the DiffDP model contains a forward process and a reverse process. In the forward process, DiffDP gradually transforms dose distribution maps into Gaussian noise by adding small noise and trains a noise predictor to predict the noise added in each timestep. In the reverse process, it removes the noise from the original Gaussian noise in multiple steps with the well-trained noise predictor and finally outputs the predicted dose distribution map. To ensure the accuracy of the prediction, we further design a structure encoder to extract anatomical information from patient anatomy images and enable the noise predictor to be aware of the dose constraints within several essential organs, i.e., the planning target volume and organs at risk. Extensive experiments on an in-house dataset with 130 rectum cancer patients demonstrate the s
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
The JUNO experiment Top Tracker
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato
, et al. (592 additional authors not shown)
Abstract:
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector…
▽ More
The main task of the Top Tracker detector of the neutrino reactor experiment Jiangmen Underground Neutrino Observatory (JUNO) is to reconstruct and extrapolate atmospheric muon tracks down to the central detector. This muon tracker will help to evaluate the contribution of the cosmogenic background to the signal. The Top Tracker is located above JUNO's water Cherenkov Detector and Central Detector, covering about 60% of the surface above them. The JUNO Top Tracker is constituted by the decommissioned OPERA experiment Target Tracker modules. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multianode photomultiplier tubes. Compared to the OPERA Target Tracker, the JUNO Top Tracker uses new electronics able to cope with the high rate produced by the high rock radioactivity compared to the one in Gran Sasso underground laboratory. This paper will present the new electronics and mechanical structure developed for the Top Tracker of JUNO along with its expected performance based on the current detector simulation.
△ Less
Submitted 9 March, 2023;
originally announced March 2023.
-
JUNO sensitivity to $^7$Be, $pep$, and CNO solar neutrinos
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Marco Beretta
, et al. (592 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO), the first multi-kton liquid scintillator detector, which is under construction in China, will have a unique potential to perform a real-time measurement of solar neutrinos well below the few MeV threshold typical for Water Cherenkov detectors. JUNO's large target mass and excellent energy resolution are prerequisites for reaching unprecedented levels of precision. In this paper, we provide estimation of the JUNO sensitivity to 7Be, pep, and CNO solar neutrinos that can be obtained via a spectral analysis above the 0.45 MeV threshold. This study is performed assuming different scenarios of the liquid scintillator radiopurity, ranging from the most opti mistic one corresponding to the radiopurity levels obtained by the Borexino experiment, up to the minimum requirements needed to perform the neutrino mass ordering determination with reactor antineutrinos - the main goal of JUNO. Our study shows that in most scenarios, JUNO will be able to improve the current best measurements on 7Be, pep, and CNO solar neutrino fluxes. We also perform a study on the JUNO capability to detect periodical time variations in the solar neutrino flux, such as the day-night modulation induced by neutrino flavor regeneration in Earth, and the modulations induced by temperature changes driven by helioseismic waves.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Study on U/Th residual radioactivity in acrylic from surface treatment
Authors:
Yuanxia Li,
Xiaohui Qian,
Xiaolan Luo,
Jie Zhao,
Gaofeng Zhang,
Xiaoyan Ma,
Yuekun Heng,
Liangjian Wen,
Monica Sisti,
Frédéric Perrot,
Hongqiang Tang
Abstract:
Acrylic is widely used as material for the target container in low background experiments due to its high light transparency and low intrinsic radioactivity. However, its surface can be easily contaminated during production, so careful treatment of the surface is essential to avoid direct contamination of the target. The Jiangmen Underground Neutrino Observatory will use about 600~t of acrylic to…
▽ More
Acrylic is widely used as material for the target container in low background experiments due to its high light transparency and low intrinsic radioactivity. However, its surface can be easily contaminated during production, so careful treatment of the surface is essential to avoid direct contamination of the target. The Jiangmen Underground Neutrino Observatory will use about 600~t of acrylic to build the spherical vessel of 35.4~m in diameter for a 20~kt liquid scintillator (LS). Since acrylic will contact the LS directly, the cleanliness of the its surface is quite important for the radiopurity of the LS. A new method for measuring the radioactivity of $^{238}$U and $^{232}$Th in acrylic to sub-ppt ($<10^{-12}$~g/g) was developed, and it is crucial for the acrylic radioactivity screening in this study. We performed many background tests on different surface treatments, and the recommended procedure for the treatment of acrylic to achieve low radioactivity and high light transparency could be applicable to other low background experiments.
△ Less
Submitted 12 January, 2023;
originally announced January 2023.
-
Simulation Software of the JUNO Experiment
Authors:
Tao Lin,
Yuxiang Hu,
Miao Yu,
Haosen Zhang,
Simon Charles Blyth,
Yaoguang Wang,
Haoqi Lu,
Cecile Jollet,
João Pedro Athayde Marcondes de André,
Ziyan Deng,
Guofu Cao,
Fengpeng An,
Pietro Chimenti,
Xiao Fang,
Yuhang Guo,
Wenhao Huang,
Xingtao Huang,
Rui Li,
Teng Li,
Weidong Li,
Xinying Li,
Yankai Liu,
Anselmo Meregaglia,
Zhen Qian,
Yuhan Ren
, et al. (9 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose experiment, under construction in southeast China, that is designed to determine the neutrino mass ordering and precisely measure neutrino oscillation parameters. Monte Carlo simulation plays an important role for JUNO detector design, detector commissioning, offline data processing, and physics processing. The JUNO experiment…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose experiment, under construction in southeast China, that is designed to determine the neutrino mass ordering and precisely measure neutrino oscillation parameters. Monte Carlo simulation plays an important role for JUNO detector design, detector commissioning, offline data processing, and physics processing. The JUNO experiment has the world's largest liquid scintillator detector instrumented with many thousands of PMTs. The broad energy range of interest, long lifetime, and the large scale present data processing challenges across all areas. This paper describes the JUNO simulation software, highlighting the challenges of JUNO simulation and solutions to meet these challenges, including such issues as support for time-correlated analysis, event mixing, event correlation and handling the simulation of many millions of optical photons.
△ Less
Submitted 17 May, 2023; v1 submitted 20 December, 2022;
originally announced December 2022.
-
Data-driven simultaneous vertex and energy reconstruction for large liquid scintillator detectors
Authors:
Gui-hong Huang,
Wei Jiang,
Liang-jian Wen,
Yi-fang Wang,
Wu-Ming Luo
Abstract:
High precision vertex and energy reconstruction is crucial for large liquid scintillator detectors such as JUNO, especially for the determination of the neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos. This paper presents a data-driven method to obtain more realistic and more accurate expected PMT response of positron events in JUNO, and develops a simultaneous vertex…
▽ More
High precision vertex and energy reconstruction is crucial for large liquid scintillator detectors such as JUNO, especially for the determination of the neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos. This paper presents a data-driven method to obtain more realistic and more accurate expected PMT response of positron events in JUNO, and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs. For the JUNO detector, the impact of vertex inaccuracy on the energy resolution is about 0.6\%.
△ Less
Submitted 30 November, 2022;
originally announced November 2022.
-
Determine Energy Nonlinearity and Resolution of $e^{\pm}$ and $γ$ in Liquid Scintillator Detectors by A Universal Energy Response Model
Authors:
Miao Yu,
Liangjian Wen,
Xiang Zhou,
Wuming Luo
Abstract:
Energy nonlinearity and resolution in liquid scintillator (LS) detectors are correlated and particle-dependent. A unified energy response model for liquid scintillator detectors has been presented in details. This model has advanced a data-driven approach to calibrate the particle-dependent energy response, using both the monoenergetic $γ$-ray sources and the continuous $β$ spectra of…
▽ More
Energy nonlinearity and resolution in liquid scintillator (LS) detectors are correlated and particle-dependent. A unified energy response model for liquid scintillator detectors has been presented in details. This model has advanced a data-driven approach to calibrate the particle-dependent energy response, using both the monoenergetic $γ$-ray sources and the continuous $β$ spectra of $^\mathrm{12}\mathrm{B}$ and Michel $e^-$ induced by cosmic muons. Monte Carlo studies have demonstrated the effectiveness and robustness of the proposed model, in particular, the positron energy resolution can be extracted in the absence of positron sources. This work will provide a feasible approach of simultaneous calibration of energy nonlinearity and resolution for the running and future LS detectors.
△ Less
Submitted 10 November, 2022; v1 submitted 4 November, 2022;
originally announced November 2022.
-
A centimeter-scale achromatic hybrid metalens with polarization-insensitivity in the visible
Authors:
Tie Hu,
Shengqi Wang,
Yunxuan Wei,
Liqing Wen,
Xing Feng,
Ming Zhao,
Zhenyu Yang
Abstract:
Metalenses, featuring ultra-compactness and CMOS compatibility, are limited by the compromise between the diameter, numerical aperture, and working waveband. To address this problem, we propose and numerically demonstrate a centimeter-scale metasurface-refractive hybrid metalens working in the band of 440 - 700 nm. Revisiting the general Snell law, we present the phase profile of a chromatic aberr…
▽ More
Metalenses, featuring ultra-compactness and CMOS compatibility, are limited by the compromise between the diameter, numerical aperture, and working waveband. To address this problem, we propose and numerically demonstrate a centimeter-scale metasurface-refractive hybrid metalens working in the band of 440 - 700 nm. Revisiting the general Snell law, we present the phase profile of a chromatic aberration correction metasurface that can apply to a plano-convex refractive lens of an arbitrary surface type. Simulated by our semi-vector method, the designed achromatic hybrid metalens achieves 81% chromatic aberration suppression and polarization insensitivity. Broadband imaging results of the hybrid metalens are further provided, verifying the achromatism of the designed hybrid metalens. It can find applications in camera lenses and other optical systems that need compact, high-performance lenses.
△ Less
Submitted 31 October, 2022;
originally announced October 2022.
-
Expected geoneutrino signal at JUNO using local integrated 3-D refined crustal model
Authors:
Ran Han,
ZhiWei Li,
Ruohan Gao,
Yao Sun,
Ya Xu,
Yufei Xi,
Guangzheng Jiang,
Andong Wang,
Yaping Cheng,
Yao Sun,
Jie Pang,
Qi Hua,
Liangjian Wen,
Liang Zhan,
Yu-Feng Li
Abstract:
Geoneutrinos serve as a potent tool for comprehending the radiogenic power and composition of Earth. Although geoneutrinos have been observed in prior experiments, the forthcoming generation of experiments,such as JUNO, will be necessary for fully harnessing their potential. Precise prediction of the crustal contribution is vital for interpreting particlephysics measurements in the context of geo-…
▽ More
Geoneutrinos serve as a potent tool for comprehending the radiogenic power and composition of Earth. Although geoneutrinos have been observed in prior experiments, the forthcoming generation of experiments,such as JUNO, will be necessary for fully harnessing their potential. Precise prediction of the crustal contribution is vital for interpreting particlephysics measurements in the context of geo-scientific inquiries. Nonetheless, existing models such as JULOC and GIGJ have limitations in accurately forecasting the crustal contribution. This paper introduces JULOCI, the novel 3-D integrated crustal model of JUNO, which employs seismic, gravity, rock sample, and heat flow data to precisely estimate the geoneutrino signal of the lithosphere. The model indicates elevated concentrations of uranium and thorium in southern China, resulting in unexpectedly strong geoneutrino signals.The accuracy of JULOC-I, coupled with a decade of experimental data, affords JUNO the opportunity to test multiple mantle models. Once operational, JUNO can validate the model predictions and enhance the precision of mantle measurements. All in all, the improved accuracy ofJULOC-I represents a substantial stride towards comprehending the geochemical distribution of the South China crust, offering a valuable tool for investigating the composition and evolution of the Earth through geoneutrinos.
△ Less
Submitted 6 March, 2024; v1 submitted 17 October, 2022;
originally announced October 2022.
-
Energy Dissipation and Asymmetric Excitation in Hybrid Waveguides for Routing and Coloring
Authors:
Xianguang Yang,
Long Wen,
Jiahao Yan,
Yanjun Bao,
Qin Chen,
Andrea Camposeo,
Dario Pisignano,
Baojun Li
Abstract:
The delivery of optical signals from an external light source to a nanoscale waveguide is highly important for the development of nanophotonic circuits. However, the efficient coupling of external light energy into nanophotonic components is difficult and still remains a challenge. Herein, we use an external silica nanofiber to light up an organic-inorganic hybrid nano-waveguide, namely a system c…
▽ More
The delivery of optical signals from an external light source to a nanoscale waveguide is highly important for the development of nanophotonic circuits. However, the efficient coupling of external light energy into nanophotonic components is difficult and still remains a challenge. Herein, we use an external silica nanofiber to light up an organic-inorganic hybrid nano-waveguide, namely a system composed of a polymer filament doped with MoS$_{2}$ quantum dots. Nanofiber-excited nano-waveguides in a crossed geometry are found to asymmetrically couple excitation signals along two opposite directions, with different energy dissipation resulting in different colors of the light emitted by MoS$_{2}$ quantum dots and collected from the waveguide terminals. Interestingly, rainbow-like light in the hybrid waveguide is achieved by three-in-one mixing of red, green, and blue components. This hetero-dimensional system of dots-in-waveguide represents a significant advance towards all-optical routing and full-color display in integrated nanophotonic devices.
△ Less
Submitted 24 September, 2022;
originally announced September 2022.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Development of silicon interposer: towards an ultralow radioactivity background photodetector system
Authors:
Haibo Yang,
Qidong Wang,
Guofu Cao,
Kali M. Melby,
Khadouja Harouaka,
Isaac J. Arnquist,
Fengwei Dai,
Liqiang Cao,
Liangjian Wen
Abstract:
It is of great importance to develop a photodetector system with an ultralow radioactivity background in rare event searches. Silicon photomultipliers (SiPMs) and application-specific integrated circuits (ASICs) are two ideal candidates for low background photosensors and readout electronics, respectively, because they are mainly composed of silicon, which can achieve good radio-purity without con…
▽ More
It is of great importance to develop a photodetector system with an ultralow radioactivity background in rare event searches. Silicon photomultipliers (SiPMs) and application-specific integrated circuits (ASICs) are two ideal candidates for low background photosensors and readout electronics, respectively, because they are mainly composed of silicon, which can achieve good radio-purity without considerable extra effort. However, interposers, used to provide mechanical support and signal routes between the photosensor and the electronics, are a bottleneck in building ultralow background photodetectors. Silicon and quartz are two candidates to construct the low background interposer because of their good radio-purity; nevertheless, it is non-trivial to produce through silicon vias (TSV) or through quartz vias (TQV) on the large area silicon or quartz wafer. In this work, based on double-sided TSV interconnect technology, we developed the first prototype of a silicon interposer with a size of 10~cm$\times$10~cm and a thickness of 320~$μ$m. The electrical properties of the interposer are carefully evaluated at room temperature, and its performance is also examined at -110~$^\circ$C with an integrated SiPM on the interposer. The testing results reveal quite promising performance of the prototype, and the single photoelectron signals can be clearly observed from the SiPM. The features of the observed signals are comparable with those from the SiPM mounted on a normal FR4-based PCB. Based on the success of the silicon interposer prototype, we started the follow-up studies that aimed to further improve the performance and yield of the silicon interposer, and eventually to provide a solution for building an ultralow background photodetector system.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
Prospects for Detecting the Diffuse Supernova Neutrino Background with JUNO
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (577 additional authors not shown)
Abstract:
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced n…
▽ More
We present the detection potential for the diffuse supernova neutrino background (DSNB) at the Jiangmen Underground Neutrino Observatory (JUNO), using the inverse-beta-decay (IBD) detection channel on free protons. We employ the latest information on the DSNB flux predictions, and investigate in detail the background and its reduction for the DSNB search at JUNO. The atmospheric neutrino induced neutral current (NC) background turns out to be the most critical background, whose uncertainty is carefully evaluated from both the spread of model predictions and an envisaged \textit{in situ} measurement. We also make a careful study on the background suppression with the pulse shape discrimination (PSD) and triple coincidence (TC) cuts. With latest DSNB signal predictions, more realistic background evaluation and PSD efficiency optimization, and additional TC cut, JUNO can reach the significance of 3$σ$ for 3 years of data taking, and achieve better than 5$σ$ after 10 years for a reference DSNB model. In the pessimistic scenario of non-observation, JUNO would strongly improve the limits and exclude a significant region of the model parameter space.
△ Less
Submitted 13 October, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Mass Testing and Characterization of 20-inch PMTs for JUNO
Authors:
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Abid Aleem,
Tsagkarakis Alexandros,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
Joao Pedro Athayde Marcondes de Andre,
Didier Auguste,
Weidong Bai,
Nikita Balashov,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli
, et al. (541 additional authors not shown)
Abstract:
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program whic…
▽ More
Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).
△ Less
Submitted 17 September, 2022; v1 submitted 17 May, 2022;
originally announced May 2022.
-
A New Optical Model for Photomultiplier Tubes
Authors:
Yaoguang Wang,
Guofu Cao,
Liangjian Wen,
Yifang Wang
Abstract:
It is critical to construct an accurate optical model of photomultiplier tubes (PMTs) in many applications to describe the angular and spectral responses of the photon detection efficiency (PDE) of the PMTs in their working media. In this study, we propose a new PMT optical model to describe both light interactions with the PMT window and optical processes inside PMTs with reasonable accuracy base…
▽ More
It is critical to construct an accurate optical model of photomultiplier tubes (PMTs) in many applications to describe the angular and spectral responses of the photon detection efficiency (PDE) of the PMTs in their working media. In this study, we propose a new PMT optical model to describe both light interactions with the PMT window and optical processes inside PMTs with reasonable accuracy based on the optics theory and a GEANT4-based simulation toolkit. The proposed model builds a relationship between the PDE and the underlying processes that the PDE relies on. This model also provides a tool to transform the PDE measured in one working medium (like air) to the PDE in other media (like water, liquid scintillator, etc). Using two 20" MCP-PMTs and one 20" dynode PMT, we demonstrate a complete procedure to obtain the key parameters used in the model from experimental data, such as the optical properties of the antireflective coating and photocathode of the three PMTs. The proposed model can effectively reproduce the angular responses of the quantum efficiency of PMTs, even though an ideally uniform photocathode is assumed in the model. Interestingly, the proposed model predicts a similar level ($20\%\sim30\%$) of light yield excess observed in the experimental data of many liquid scintillator-based neutrino detectors, compared with that predicted at the stage of detector design. However, this excess has never been explained, and the proposed PMT model provides a good explanation for it, which highlights the imperfections of PMT models used in their detector simulations.
△ Less
Submitted 6 April, 2022;
originally announced April 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
Large-composition-range pure-phase homogeneous InAs$_{1-x}$Sb$_x$ nanowires
Authors:
Lianjun Wen,
Dong Pan,
Lei Liu,
Shucheng Tong,
Ran Zhuo,
Jianhua Zhao
Abstract:
Narrow bandgap InAs$_{1-x}$Sb$_x$ nanowires show broad prospects for applications in wide spectrum infrared detectors, high-performance transistors and quantum computation. Realizing such applications require the fine control of composition and crystal structure of nanowires. However, to date, the fabrication of large-composition-range pure-phase homogeneous InAs$_{1-x}$Sb$_x$ nanowires remains a…
▽ More
Narrow bandgap InAs$_{1-x}$Sb$_x$ nanowires show broad prospects for applications in wide spectrum infrared detectors, high-performance transistors and quantum computation. Realizing such applications require the fine control of composition and crystal structure of nanowires. However, to date, the fabrication of large-composition-range pure-phase homogeneous InAs$_{1-x}$Sb$_x$ nanowires remains a huge challenge. Here, we first report the growth of large-composition-range stemless InAs$_{1-x}$Sb$_x$ nanowires (x = 0-0.63) on Si (111) substrates by molecular-beam epitaxy. It is found that pure-phase InAs$_{1-x}$Sb$_x$ nanowires can be successfully obtained by controlling the antimony content x, nanowire diameter and nanowire growth direction. Detailed EDS data show that the antimony is uniformly distributed along the axial and radial directions of InAs$_{1-x}$Sb$_x$ nanowires and no spontaneous core-shell nanostructures form in the nanowires. Based on field-effect measurements, we confirm that InAs$_{1-x}$Sb$_x$ nanowires exhibit good conductivity and their mobilities can be up to 4200 cm^2/V.s at 7 K. Our work lays the foundation for the development of InAs$_{1-x}$Sb$_x$ nanowire optoelectronic, electronic and quantum devices.
△ Less
Submitted 3 November, 2021;
originally announced November 2021.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
Radioactivity control strategy for the JUNO detector
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld,
Sylvie Blin
, et al. (578 additional authors not shown)
Abstract:
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particula…
▽ More
JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day, therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz in the default fiducial volume, above an energy threshold of 0.7 MeV.
△ Less
Submitted 13 October, 2021; v1 submitted 8 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Davide Basilico,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Thilo Birkenfeld
, et al. (582 additional authors not shown)
Abstract:
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of…
▽ More
The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator to assure that all components of the JUNO scintillator system work to specifications and only neutrino-grade scintillator is filled into the JUNO Central Detector. The aspired sensitivity level of $10^{-16}$ g/g of $^{238}$U and $^{232}$Th requires a large ($\sim$20 m$^3$) detection volume and ultralow background levels. The present paper reports on the design and major components of the OSIRIS detector, the detector simulation as well as the measuring strategies foreseen and the sensitivity levels to U/Th that can be reached in this setup.
△ Less
Submitted 31 March, 2021;
originally announced March 2021.
-
Full-color nanorouter for high-resolution imaging
Authors:
Mingjie Chen,
Long Wen,
Dahui Pan,
David R. S. Cumming,
Xianguang Yang,
Qin Chen
Abstract:
Pixel scaling effects have been a major issue for the development of high-resolution color image sensors due to the reduced photoelectric signal and the color crosstalk. Various structural color techniques have been proposed and demonstrated the large freedom in color manipulation by the structure design. However, the optical efficiency and the color distortion limit the practical applications due…
▽ More
Pixel scaling effects have been a major issue for the development of high-resolution color image sensors due to the reduced photoelectric signal and the color crosstalk. Various structural color techniques have been proposed and demonstrated the large freedom in color manipulation by the structure design. However, the optical efficiency and the color distortion limit the practical applications due to its intrinsic filtering mechanism. Instead, on-chip full-color routing is quite charming for improving the signal-to-noise ratio. In this paper, a single-layer quick response code like nanorouter is proposed for the full-color light routing in a pixel level of image sensors. It shows much higher routing efficiency than various planar lens schemes for signal wavelength focusing. Moreover, over 60% signal enhancement with robust polarization insensitivity is obtained in all three primary color bands with a same nanorouter by a multi-objective optimization method. Negligible color distortion is observed from the reconstructed color image. Such a simple nanorouter structure is promising for the development of image sensor, photovoltaics and display.
△ Less
Submitted 30 March, 2021;
originally announced March 2021.
-
Improving the energy uniformity for large liquid scintillator detectors
Authors:
Guihong Huang,
Yifang Wang,
Wuming Luo,
Liangjian Wen,
Zeyuan Yu,
Weidong Li,
Guofu Cao,
Ziyan Deng,
Tao Lin,
Jiaheng Zou,
Miao Yu
Abstract:
It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to reconstruct event energy in the JUNO experiment. In this paper, we investigated the choice of calibration sources thoroughly, optimized the calibration positions and co…
▽ More
It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to reconstruct event energy in the JUNO experiment. In this paper, we investigated the choice of calibration sources thoroughly, optimized the calibration positions and corrected the residual detector azimuthal asymmetry. All these efforts lead to a reduction of the energy non-uniformity near the detector boundary, from about 0.64% to 0.38%. And within the fiducial volume of the detector it is improved from 0.3% to 0.17%. As a result the energy resolution could be further improved.
△ Less
Submitted 31 March, 2021; v1 submitted 7 February, 2021;
originally announced February 2021.
-
Event vertex and time reconstruction in large volume liquid scintillator detector
Authors:
Ziyuan Li,
Yumei Zhang,
Guofu Cao,
Ziyan Deng,
Guihong Huang,
Weidong Li,
Tao Lin,
Liangjian Wen,
Miao Yu,
Jiaheng Zou,
Wuming Luo,
Zhengyun You
Abstract:
Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter. Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy. In this study, four event vertex and event time reconstruction algorithms using charge and time information collected by…
▽ More
Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter. Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy. In this study, four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively. The effects of photomultiplier tube properties were also investigated. The results indicate that the transit time spread is the main effect degrading the vertex reconstruction, while the effect of dark noise is limited. In addition, when the event is close to the detector boundary, the charge information provides better performance for vertex reconstruction than the time information.
△ Less
Submitted 13 May, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
A practical approach of high precision U and Th concentration measurement in acrylic
Authors:
Chuanya Cao,
Nan Li,
Xiaoyu Yang,
Jie Zhao,
Yuanxia Li,
Zhiyan Cai,
Liangjian Wen,
Xiaolan Luo,
Yuekun Heng,
Yayun Ding
Abstract:
The Jiangmen Underground Neutrino Observatory will build the world's largest liquid scintillator detector to study neutrinos from various sources. The 20 kt liquid scintillator will be stored in a $\sim$600 t acrylic sphere with 35.4 m diameter due to the good light transparency, chemical compatibility and low radioactivity of acrylic. The concentration of U/Th in acrylic is required to be less th…
▽ More
The Jiangmen Underground Neutrino Observatory will build the world's largest liquid scintillator detector to study neutrinos from various sources. The 20 kt liquid scintillator will be stored in a $\sim$600 t acrylic sphere with 35.4 m diameter due to the good light transparency, chemical compatibility and low radioactivity of acrylic. The concentration of U/Th in acrylic is required to be less than 1 ppt (10$^{-12}$ g/g) to achieve a low radioactive background in the fiducial volume of the JUNO detector. The mass production of acrylic has started, and the quality control requires a fast and reliable radioassay on U/Th in acrylic. We have developed a practical method of measuring U/Th in acrylic to sub-ppt level using the Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The U/Th in acrylic can be concentrated by vaporizing acrylic in a class 100 environment, and the residue will be collected and sent to ICP-MS for measuring U/Th. All the other chemical operation is done in a class 100 clean room, and the ICP-MS measurement is done in a class 1000 clean room. The recovery efficiency is studied by adding the natural nonexistent nuclei $^{229}$Th and $^{233}$U as the tracers. The resulting method detection limit (MDL) with 99% confidence can reach 0.02/0.06 pg $^{238}$U/$^{232}$Th /g acrylic with $\sim$75% recovery efficiency. This equipment and method can not only be used for the quality control of JUNO acrylic, but also be further optimized for the radioassay on other materials with extremely low radioactivity, such as ultra-pure water and liquid scintillator.
△ Less
Submitted 13 November, 2020;
originally announced November 2020.
-
Calibration Strategy of the JUNO Experiment
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Rizwan Ahmed,
Sebastiano Aiello,
Muhammad Akram,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
Thilo Birkenfeld
, et al. (571 additional authors not shown)
Abstract:
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector ca…
▽ More
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination.
△ Less
Submitted 20 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.
-
Evaluation of the KLauS ASIC at low temperature
Authors:
Wei Wang,
Wei Shen,
Zhenxiong Yuan,
Konrad Briggl,
Hans-Christian Schultz-Coulon,
Wenqi Yan,
Guofu Cao,
Zepeng Li,
Ming Qi,
Liangjian Wen
Abstract:
The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (-50~$^\circ$C) equipped with large-area silicon photomultipliers (SiPMs) ($\sim$10~m$^2$) to precisely measure the reactor antineutrino spectrum with a record energy resolution of < 2\% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution…
▽ More
The Taishan Antineutrino Observatory (TAO) is proposed to first use a cold liquid scintillator detector (-50~$^\circ$C) equipped with large-area silicon photomultipliers (SiPMs) ($\sim$10~m$^2$) to precisely measure the reactor antineutrino spectrum with a record energy resolution of < 2\% at 1 MeV. The KLauS ASIC shows excellent performance at room temperature and is a potential readout solution for TAO. In this work, we report evaluations of the fifth version of the KLauS ASIC (KLauS5) from room temperature to -50~$^\circ$C with inputs of injected charge or SiPMs. Our results show that KLauS5 has good performance at the tested temperatures with no significant degradation of the charge noise, charge linearity, gain uniformity or recovery time. Meanwhile, we also observe that several key parameters degrade when the chip operates in cold conditions, including the dynamic range and power consumption. However, even with this degradation, a good signal-to-noise ratio and good resolution of a single photoelectron can still be achieved for the tested SiPM with a gain of greater than 1.5$\times$10$^6$ and even an area of SiPM up to 1~cm$^2$ in one channel, corresponding to an input capacitance of approximately 5~nF. Thus, we conclude that KLauS5 can fulfill the TAO requirements for precise charge measurement.
△ Less
Submitted 11 November, 2020; v1 submitted 11 November, 2020;
originally announced November 2020.
-
Event Reconstruction in a Liquid Xenon Time Projection Chamber with an Optically-Open Field Cage
Authors:
T. Stiegler,
S. Sangiorgio,
J. P. Brodsky,
M. Heffner,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon
, et al. (126 additional authors not shown)
Abstract:
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier…
▽ More
nEXO is a proposed tonne-scale neutrinoless double beta decay ($0νββ$) experiment using liquid ${}^{136}Xe$ (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe ("skin" LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. In this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the $γ$-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Second, background from ${}^{222}Rn$ dissolved in the skin LXe can be efficiently rejected by tagging the $α$ decay in the ${}^{214}Bi-{}^{214}Po$ chain in the skin LXe.
△ Less
Submitted 24 March, 2021; v1 submitted 21 September, 2020;
originally announced September 2020.
-
Polarizing the Medium: Fermion-Mediated Interactions between Bosons
Authors:
Dong-Chen Zheng,
Lin Wen,
Chun-Rong Ye,
Renyuan Liao
Abstract:
We consider a homogeneous mixture of bosons and polarized fermions. We find that long-range and attractive fermion-mediated interactions between bosons have dramatic effects on the properties of the bosons. We construct the phase diagram spanned by boson-fermion mass ratio and boson-fermion scattering parameter. It consists of stable region of mixing and unstable region toward phase separation. In…
▽ More
We consider a homogeneous mixture of bosons and polarized fermions. We find that long-range and attractive fermion-mediated interactions between bosons have dramatic effects on the properties of the bosons. We construct the phase diagram spanned by boson-fermion mass ratio and boson-fermion scattering parameter. It consists of stable region of mixing and unstable region toward phase separation. In stable mixing phase, the collective long-wavelength excitations can either be well-behaved with infinite lifetime or be finite in lifetime suffered from the Landau damping. We examine the effects of the induced interaction on the properties of weakly interacting bosons. It turns out that the induced interaction not only enhances the repulsion between the bosons against collapse but also enhances the stability of the superfluid state by suppressing quantum depletion.
△ Less
Submitted 9 July, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector
Authors:
Daya Bay,
JUNO collaborations,
:,
A. Abusleme,
T. Adam,
S. Ahmad,
S. Aiello,
M. Akram,
N. Ali,
F. P. An,
G. P. An,
Q. An,
G. Andronico,
N. Anfimov,
V. Antonelli,
T. Antoshkina,
B. Asavapibhop,
J. P. A. M. de André,
A. Babic,
A. B. Balantekin,
W. Baldini,
M. Baldoncini,
H. R. Band,
A. Barresi,
E. Baussan
, et al. (642 additional authors not shown)
Abstract:
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were…
▽ More
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Search For Electron-Antineutrinos Associated With Gravitational-Wave Events GW150914, GW151012, GW151226, GW170104, GW170608, GW170814, and GW170817 at Daya Bay
Authors:
F. P. An,
A. B. Balantekin,
H. R. Band,
M. Bishai,
S. Blyth,
G. F. Cao,
J. Cao,
J. F. Chang,
Y. Chang,
H. S. Chen,
S. M. Chen,
Y. Chen,
Y. X. Chen,
J. Cheng,
Z. K. Cheng,
J. J. Cherwinka,
M. C. Chu,
J. P. Cummings,
O. Dalager,
F. S. Deng,
Y. Y. Ding,
M. V. Diwan,
T. Dohnal,
J. Dove,
M. Dvorak
, et al. (161 additional authors not shown)
Abstract:
Providing a possible connection between neutrino emission and gravitational-wave (GW) bursts is important to our understanding of the physical processes that occur when black holes or neutron stars merge. In the Daya Bay experiment, using data collected from December 2011 to August 2017, a search has been performed for electron-antineutrino signals coinciding with detected GW events, including GW1…
▽ More
Providing a possible connection between neutrino emission and gravitational-wave (GW) bursts is important to our understanding of the physical processes that occur when black holes or neutron stars merge. In the Daya Bay experiment, using data collected from December 2011 to August 2017, a search has been performed for electron-antineutrino signals coinciding with detected GW events, including GW150914, GW151012, GW151226, GW170104, GW170608, GW170814, and GW170817. We used three time windows of $\mathrm{\pm 10~s}$, $\mathrm{\pm 500~s}$, and $\mathrm{\pm 1000~s}$ relative to the occurrence of the GW events, and a neutrino energy range of 1.8 to 100 MeV to search for correlated neutrino candidates. The detected electron-antineutrino candidates are consistent with the expected background rates for all the three time windows. Assuming monochromatic spectra, we found upper limits (90% confidence level) on electron-antineutrino fluence of $(1.13~-~2.44) \times 10^{11}~\rm{cm^{-2}}$ at 5 MeV to $8.0 \times 10^{7}~\rm{cm^{-2}}$ at 100 MeV for the three time windows. Under the assumption of a Fermi-Dirac spectrum, the upper limits were found to be $(5.4~-~7.0)\times 10^{9}~\rm{cm^{-2}}$ for the three time windows.
△ Less
Submitted 14 September, 2020; v1 submitted 27 June, 2020;
originally announced June 2020.
-
Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO
Authors:
JUNO collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (572 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid s…
▽ More
The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO's features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO's potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.
-
TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution
Authors:
JUNO Collaboration,
Angel Abusleme,
Thomas Adam,
Shakeel Ahmad,
Sebastiano Aiello,
Muhammad Akram,
Nawab Ali,
Fengpeng An,
Guangpeng An,
Qi An,
Giuseppe Andronico,
Nikolay Anfimov,
Vito Antonelli,
Tatiana Antoshkina,
Burin Asavapibhop,
João Pedro Athayde Marcondes de André,
Didier Auguste,
Andrej Babic,
Wander Baldini,
Andrea Barresi,
Eric Baussan,
Marco Bellato,
Antonio Bergnoli,
Enrico Bernieri,
David Biare
, et al. (568 additional authors not shown)
Abstract:
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future re…
▽ More
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.
-
Co-precipitation approach to measure amount of $^{238}$U in copper to sub-ppt level using ICP-MS
Authors:
Ya-Yun Ding,
Meng-Chao Liu,
Jie Zhao,
Wen-Qi Yan,
Liang-Hong Wei,
Zhi-Yong Zhang,
Liang-Jian Wen
Abstract:
Inductively coupled plasma mass (ICP-MS) spectroscopy is widely used for screening materials of low background detectors in dark matter and double beta decay searches due to its high sensitivity to trace $^{238}$U and $^{232}$Th. This work describes a novel co-precipitation approach to measure the amount of $^{238}$U in high-purity copper to sub-ppt level. Such an approach allows the pre-concentra…
▽ More
Inductively coupled plasma mass (ICP-MS) spectroscopy is widely used for screening materials of low background detectors in dark matter and double beta decay searches due to its high sensitivity to trace $^{238}$U and $^{232}$Th. This work describes a novel co-precipitation approach to measure the amount of $^{238}$U in high-purity copper to sub-ppt level. Such an approach allows the pre-concentration of U and removal of the matrix, by selecting a proper precipitator to co-precipitate with $^{238}$U and using excess ammonia water to separate the uranium hydroxide from copper by forming water-soluble tetra-amminecopper (II). The isotope dilution method and standard addition method were both used to mitigate the matrix effect and cross-check each other. The latter was also used to measure the recovery efficiency of $^{238}$U by using $^{233}$U as the tracer. The method detection limit (MDL) reached $\sim$0.1 pg $^{238}$U /g Cu for both methods while the recovery efficiency of uranium robustly remains 65\%--85\%. Various sources of interference in the ICP-MS analysis were thoroughly evaluated, and the contamination from reagents were found to be the dominant factor that affected the MDL. Further purification will allow significant improvements in the MDL. This co-precipitate approach can be easily extended to measure $^{232}$Th by using $^{229}$Th as the tracer.
△ Less
Submitted 27 March, 2020;
originally announced March 2020.
-
A complete optical model for liquid-scintillator detectors
Authors:
Yan Zhang,
Ze-Yuan Yu,
Xin-Ying Li,
Zi-Yan Deng,
Liang-Jian Wen
Abstract:
Liquid scintillator (LS) is widely used in various neutrino oscillation experiments, in particular, the reactor neutrino experiments. The complex absorption and re-emission processes of optical photons are known to be an important source of the non-linear and non-uniform response of LS detectors. Precise simulation of light propagation in LS is highly desirable to model the detector response and r…
▽ More
Liquid scintillator (LS) is widely used in various neutrino oscillation experiments, in particular, the reactor neutrino experiments. The complex absorption and re-emission processes of optical photons are known to be an important source of the non-linear and non-uniform response of LS detectors. Precise simulation of light propagation in LS is highly desirable to model the detector response and reduce the systematic errors. In this paper, we develop a novel optical model which can completely deal with the competitive photon absorption and subsequent re-emission processes of the LS components. It allows to directly plug in the laboratory measurements of the LS components to model any LS composition. Extensive measurements have been performed to obtain the essential optical parameters for this model. We validate the model with a bench-top experiment featuring a small LS volume. Furthermore, we demonstrate that for any given detector geometry, this model provides the capability of optimizing the LS recipe to maximize the light collection. It is valuable for designing future LS-based detectors and improving the agreement between Monte Carlo and data for current neutrino experiments.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
Reflectance of Silicon Photomultipliers in Linear Alkylbenzene
Authors:
W. Wang,
G. F. Cao,
Z. Q. Xie,
J. Cao,
M. Qi,
L. J. Wen
Abstract:
Reflectance of silicon photomultipliers (SiPMs) is an important aspect to understand the large scale SiPM-based detector systems and evaluate the performance of SiPMs. We report the reflactance of two SiPMs, NUV-HD-lowCT and S14160-60-50HS manufactured by Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) respectively, in linear alkylbenzene (LAB) and in air at visible wavelengths.…
▽ More
Reflectance of silicon photomultipliers (SiPMs) is an important aspect to understand the large scale SiPM-based detector systems and evaluate the performance of SiPMs. We report the reflactance of two SiPMs, NUV-HD-lowCT and S14160-60-50HS manufactured by Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) respectively, in linear alkylbenzene (LAB) and in air at visible wavelengths. Our results show that the reflectance of the FBK SiPM in air varies in the range of 14% to 23% , depending on wavelengths and angle of incidence, which is 2 time larger than that of the HPK device. This indicates that the two manufacturers are using different designs of anti-reflective coating on SiPMs' surfaces. The reflectance is reduced by about 10% when SiPMs are immersed in LAB, compared with that measured in air. The profiles of reflected light beams are also measured by a charge-coupled device (CCD) camera for the two SiPMs.
△ Less
Submitted 11 February, 2020;
originally announced February 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode
Authors:
O. Njoya,
T. Tsang,
M. Tarka,
W. Fairbank,
K. S. Kumar,
T. Rao,
T. Wager,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
W. R. Cen,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (131 additional authors not shown)
Abstract:
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measur…
▽ More
Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Topological defects of spin-orbit coupled Bose-Einstein condensates in a rotating anharmonic trap
Authors:
Chunxiao Shi,
Linghua Wen,
Qingbo Wang,
Hui Yang,
Huan Wang
Abstract:
We investigate the topological defects and spin structures of binary Bose-Einstein condensates (BECs) with Dresselhaus spin-orbit coupling (D-SOC) in a rotating anharmonic trap. Our results show that for initially mixed BECs without SOC the increasing rotation frequency can lead to the structural phase transition of the system. In the presence of isotropic D-SOC, the system sustains vortex pair,An…
▽ More
We investigate the topological defects and spin structures of binary Bose-Einstein condensates (BECs) with Dresselhaus spin-orbit coupling (D-SOC) in a rotating anharmonic trap. Our results show that for initially mixed BECs without SOC the increasing rotation frequency can lead to the structural phase transition of the system. In the presence of isotropic D-SOC, the system sustains vortex pair,Anderson--Toulouse coreless vortices, circular vortex sheets, and combined vortex structures. In particular, when the rotation frequency is fixed above the radial trapping frequency the strong D-SOC results in a peculiar topological structure which is comprised of multi-layer visible vortex necklaces, hidden vortex necklaces and a hidden giant vortex. In addition, the system exhibits rich spin textures including basic skyrmion, meron cluster, skyrmion string and various skyrmion lattices. The skyrmions will be destroyed in the limit of large D-SOC or rotation frequency. Furthermore, the effects of anisotropic D-SOC and Rashba-Dresselhaus SOC on the topological structures of the system are discussed.
△ Less
Submitted 9 November, 2019;
originally announced November 2019.
-
Ground states of dipolar spin-orbit-coupled Bose-Einstein condensates in a toroidal trap
Authors:
Hui Yang,
Qingbo Wang,
Linghua Wen
Abstract:
We investigate the ground-state structures of dipolar spin-orbit-coupled Bose-Einstein condensates in a toroidal trap. Combined effects of dipole-dipole interaction (DDI) and spin-orbit coupling (SOC) on the ground states of the system are discussed. A ground-state phase diagram is obtained as a function of the SOC and DDI strengths. As two new degrees of freedom, the DDI and SOC can be used to ob…
▽ More
We investigate the ground-state structures of dipolar spin-orbit-coupled Bose-Einstein condensates in a toroidal trap. Combined effects of dipole-dipole interaction (DDI) and spin-orbit coupling (SOC) on the ground states of the system are discussed. A ground-state phase diagram is obtained as a function of the SOC and DDI strengths. As two new degrees of freedom, the DDI and SOC can be used to obtain the desired ground-state phases and to control the phase transition between various ground states. In particular, the system displays exotic topological structures and spin textures, such as half-quantum vortex, vortex string, vortex necklace, complex vortex lattice including giant vortex and hidden antivortex chains, different skyrmions, meron (half-skyrmion)-antimeron (half-antiskyrmion) necklace, and composite meron-antimeron lattice.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
Topological excitations in rotating Bose-Einstein condensates with Rashba-Dresselhaus spin-orbit coupling in a two-dimensional optical lattice
Authors:
Hui Yang,
Qingbo Wang,
Ning Su,
Linghua Wen
Abstract:
We study the ground-state configurations and spin textures of rotating two-component Bose-Einstein condensates (BECs) with Rashba-Dresselhaus spin-orbit coupling (RD-SOC), which are confined in a two-dimensional (2D) optical lattice plus a 2D harmonic trap. In the absence of rotation, a relatively small isotropic 2D RD-SOC leads to the generation of ghost vortices for initially miscible BECs, whil…
▽ More
We study the ground-state configurations and spin textures of rotating two-component Bose-Einstein condensates (BECs) with Rashba-Dresselhaus spin-orbit coupling (RD-SOC), which are confined in a two-dimensional (2D) optical lattice plus a 2D harmonic trap. In the absence of rotation, a relatively small isotropic 2D RD-SOC leads to the generation of ghost vortices for initially miscible BECs, while it gives rise to the creation of rectangular vortex-antivortex lattices for initially immiscible BECs. As the strength of the 2D RD-SOC enhances, the visible vortices or the 2D vortex-antivortex chains are created for the former case, whereas the rectangular vortex-antivortex lattices are transformed into vortex-antivortex rings for the later case. For the initially immiscible BECs with fixed 2D RD-SOC strength, the increase of rotation frequency can result in the structural phase transition from square vortex lattice to irregular triangular vortex lattice and the system transition from initial phase separation to phase mixing. In addition, we analyze the combined effects of 1D RD-SOC and rotation on the vortex configurations of the ground states for the case of initial phase separation. The increase of 1D SOC strength, rotation frequency or both of them may result in the formation of vortex chain and phase mixing. Furthermore, the typical spin textures for both the cases of 2D RD-SOC and 1D RD-SOC are discussed. It is shown that the system favors novel spin textures and skyrmion configurations including an exotic skyrmion-half-skyrmion lattice (skyrmion-meron lattice), a complicated meron lattice, a skyrmion chain, and a Bloch domain wall.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
Ground-state properties of spin-orbit-coupled dipolar Bose-Einstein condensates with in-plane gradient magnetic field
Authors:
Xiaoqian Li,
Qingbo Wang,
Huan Wang,
Chunxiao Shi,
Malcolm Jardine,
Linghua Wen
Abstract:
We investigate the ground-state properties of spin-orbit-coupled pseudo-spin-1/2 dipolar Bose-Einstein condensates (BECs) in a two-dimensional harmonic trap and an in-plane quadrupole field. The effects of spin-orbit coupling (SOC), dipole-dipole interaction (DDI) and the in-plane quadrupole field on the ground-state structures and spin textures of the system are systematically analyzed and discus…
▽ More
We investigate the ground-state properties of spin-orbit-coupled pseudo-spin-1/2 dipolar Bose-Einstein condensates (BECs) in a two-dimensional harmonic trap and an in-plane quadrupole field. The effects of spin-orbit coupling (SOC), dipole-dipole interaction (DDI) and the in-plane quadrupole field on the ground-state structures and spin textures of the system are systematically analyzed and discussed. For fixed SOC and DDI strengths, the system shows a quadrupole stripe phase with a half-quantum vortex, or a quadrupole Thomas-Fermi phase with a half-quantum antivortex for small quadrupole field strength, depending on the ratio between inter- and intraspecies interaction. As the quadrupole field strength enhances, the system realizes a ring mixed phase with a hidden vortex-antivortex cluster rather than an ordinary giant vortex in each component. Of particular interest, when the strengths of DDI and quadrupole field are fixed, strong SOC leads to the formation of criss-crossed vortex string structure. For given SOC and quadrupole field, the system for strong DDI displays a sandwich-like structure, or a special delaminated structure with a prolate antivortex in the spin-up component. In addition, typical spin textures for the ground states of the system are analyzed. It is shown that the system sustains exotic topological structures, such as a hyperbolic spin domain wall, skyrmion-half-antiskyrmion-antiskyrmion lattice, half-skyrmion-skyrmion-half-antiskyrmion lattice, and a drum-shaped antimeron.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Ultrafast domain wall motion in ferrimagnets induced by magnetic anisotropy gradient
Authors:
W. H. Li,
Z. Jin,
D. L. Wen,
X. M. Zhang,
M. H. Qin,
J. M. Liu
Abstract:
The ultrafast magnetic dynamics in compensated ferrimagnets not only provides information similar to antiferromagnetic dynamics, but more importantly opens new opportunities for future spintronic devices [Kim et al., Nat. Mater. 16, 1187 (2017)]. One of the most essential issues for device design is searching for low-power-consuming and high-efficient methods of controlling domain wall. In this wo…
▽ More
The ultrafast magnetic dynamics in compensated ferrimagnets not only provides information similar to antiferromagnetic dynamics, but more importantly opens new opportunities for future spintronic devices [Kim et al., Nat. Mater. 16, 1187 (2017)]. One of the most essential issues for device design is searching for low-power-consuming and high-efficient methods of controlling domain wall. In this work, we propose to use the voltage-controlled magnetic anisotropy gradient as an excitation source to drive the domain wall motion in ferrimagnets. The ultrafast wall motion under the anisotropy gradient is predicted theoretically based on the collective coordinate theory, which is confirmed by the atomistic micromagnetic simulations. The antiferromagnetic spin dynamics is realized at the angular momentum compensation point, and the wall shifting has a constant speed under small gradient and can be slightly accelerated under large gradient due to the broadened wall width during the motion. For nonzero net angular momentum, the Walker breakdown occurs at a critical anisotropy gradient significantly depending on the second anisotropy and interfacial Dzyaloshinkii-Moriya interaction, which is highly appreciated for further experiments including the materials selection and device geometry design. More importantly, this work unveils a low-power-consuming method of controlling the domain wall in ferrimagnets, benefiting to future spintronic applications.
△ Less
Submitted 14 October, 2019;
originally announced October 2019.