Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
skip to main content
article

A smartphone-based U-Healthcare system for real-time monitoring of acute myocardial infarction

Published: 01 December 2015 Publication History

Abstract

In recent years, medical service has been evolving from systems designed around centralized hospitals to Ubiquitous Healthcare U-Healthcare. U-Healthcare system can facilitate real-time monitoring of patient states, and can provide medical checkups and management whenever and wherever the medical staff deems necessary. U-Healthcare services can provide chronic condition monitoring in the early stages of diseases and help execute decisive medical action in emergencies. However, thus far, the application of U-Healthcare systems has been limited to diseases such as obesity, diabetes, etc. Acute myocardial infarction AMI is among the most critical chronic diseases and requires early detection and treatment. In this paper, we propose an AMI diagnostic software technique and protocol that can support real-time communication between the patient and medical personnel. Our monitoring and diagnostic system has been developed using a protocol based on ISO/IEEE 11073. When data is transferred from the patient's smartphone to a server in hospital, the medical personnel consult the patient's biosensor data to determine the status of the relevant disease and provide appropriate medical service. The relevant information is sent back to the patient's smartphone through a wireless network, and patients can view their data in graphical format through their smartphone. Copyright © 2015 John Wiley & Sons, Ltd.

References

[1]
Lee HJ, Lee SH, Ha KS, Jang HC, Chung WY, Kim JY, Chang YS, Yoo DH. Ubiquitous healthcare service using Zigbee and mobile phone for elderly patients. International Journal of Medical Informatics 2009; Volume 78: pp.193-198.
[2]
O'Brien A, Ruairi RM. Survey of assistive technology devices and applications for aging in place. Proc. IEEE Conference on Advances in Human-oriented and Personalized Mechanisms, Technologies, and Services, Porto, Portugal, 20-25 September 2009; 7-12
[3]
Park YJ, Cho HS, Son JW. Transmitting/receiving of standard health data using Bluetooth HDP on the android platform. The Korean Institute of Communications and Information Sciences 2013; Volume 38: pp.464-470.
[4]
Ji Z, Ganchev I, O'Droma M, Máirtín Ó, Droma XZ. A cloud-based X73 ubiquitous mobile healthcare system: design and implementation. The Scientific World Journal 2014; Volume 2014: pp.1-14.
[5]
Ji Z, Zhang X, Ganchev I, O'Droma M. A content adaptation middleware for use in a mhealth system. Beijing: Proc. IEEE e-Health Networking, Applications and ServicesHealthcom, Beijing, China, 10-13 October 2012; 455-457.
[6]
Yang Z, Zhou DM. Cardiac markers and their point-of-care testing for diagnosis of acute myocardial infarction. Clinical Biochemisty 2006; Volume 39: pp.771-780.
[7]
Gillum RF. Trends in acute myocardial infarction and coronary heart disease death in the United States. Journal of the American Coolege acute-myocardial-infarction 1994; Volume 23: pp.1273-1277.
[8]
Fang J, Alderman MH, Keenan NL, Ayala C. Acute myocardial infarction hospitalization in the United States, 1979 to 2005. The American Journal of Medicine 2010; Volume 123: pp.259-266.
[9]
Park YK, Jeong JO, Park JH, Lee HS, Lee YD, Choi UL, Jin SA, Sin SK, Kim JH, Park JH, Lee JH, Choi SW, Jeong MH, Chae SC, Hur SH, Chae JK, Kim YJ, Rhew JY, Seong IW. Clinical impact of time delay on 1-year mortality in patients with ST-segment elevation myocardial infarction. The Korean Journal of Medicine 2011; Volume 81: pp.199-207.
[10]
Bolooki MH, Arman A. Acute myocardial infarction, 2010, "http://www.clevelandclinicmeded.com/medicalpubs/diseasemanagement/acute-myocardial-infarction/acute-myocardial-infarction/#top"
[11]
Choi KC, Choi SS. Factors associated with the pre-hospital delay in acute myocardial infarction. Journal of the Korea Academia-Industrial cooperation Society 2013; Volume 14: pp.707-712.
[12]
Mark W, Amanda G, Nancy A. Factors influencing treatment delays for acute myocardial infarction. Critical Care Nursing Quarterly 2009; Volume 32: pp.19-23.
[13]
Jordanova N, Gyongyosi M, Khorsand A, Falkensammer C, Zorn G, Wojta J, Anvari A, Huber K. New cut-off values of cardiac markers for risk stratification of angina pectoris. International Journal of Cardiology 2005; Volume 99: pp.429-435.
[14]
Li CG, Lee K, Lee CY, Dangol M, Jung H. A minimally invasive blood-extraction system: elastic self-recovery actuator integrated with an ultrahigh-aspect-ratio microneedle. Advanced Materials 2012; Volume 24: pp.4583-4586.
[15]
Han DH, KimYR KCM, Chung TD. Electrochemical Signal amplification for immunosensor based on 3D interdigitated array electrodes. Analytical Chemistry 2014; Volume 86: pp.5991-5998.
[16]
Park C. ISO/IEEE 11073 PHD standardization of weighting scale using Nintendo's Wii Balance boardTM for healthcare services. Proc. IEEE Consumer Electronics, Las Vegas, USA 9-13 January 2010; 195-196.
[17]
Clarke M. ISO/IEEE 11073 personal health devices, 2008, "http://person.hst.aau.dk/ska/MIE2008/ParalleSessions/PresentationsForDownloads/Mon-1530/Sta-30_Clarke.pdf"
[18]
Cao H, Leung V, Chow H. Enabling technologies for wireless body area networks: a survey and outlook. IEEE Communications Magazine 2009; Volume 47: pp.84-93.
[19]
Karthik GVS, Rahman MZU. Efficient signal conditioning techniques for brain activity in remote health monitoring network. IEEE Sensors Journal 2013; Volume 13: pp.3276-3283.
[20]
Health informatics-personal health device communication-part 20601: optimized exchange protocol. IEEE Engineering in Medicine and Biology Society, New York 2011.
[21]
Health informatics-personal health device communication-device specialization-weighing scale. IEEE Engineering in Medicine and Biology Society, New York 2008.
[22]
Health informatics-personal health device communication-device specialization-glucose meter. IEEE Engineering in Medicine and Biology Society, New York 2009.
[23]
Oka K, Aoyagi S, Arai Y, Isono Y, Hashiguchi G, Fujita H. Fabrication of a micro needle for a trace blood test. Sensors and Actuators A: Physical 2002; Volume 97: pp.478-485.
[24]
Lee JH, Jung JH, Shin DH, Kim YT. Patch type sensor module for diagnosis of acute myocardial infarction. Proc. IEEE Sensors, Taipei, Taiwan 28-31 October 2012; 1-3.
[25]
Lee JH, Jung JH, Kim YT. Design and development of mobile cardiac marker monitoring system for prevention of acute cardiovascular disease. Proc. IEEE Sensors, Limerick, Ireland 28-31 October 2011; 1724-1727.
[26]
Lee M, Gatton TM. Wireless health data exchange for home healthcare monitoring systems. Sensors Basel 2010; Volume 10: pp.3243-60.
[27]
Farmer A, Gibson O, Hayton P, Bryden K, Dudley C, Neil A, Tarassenko L. A real-time, mobile phone-based telemedicine system to support young adults with type 1 diabetes. Informatics in Primary Care 2005; Volume 13: pp.171-177.
[28]
Jung JH, Lee JH, Lee JH, Kim YT. Development of service network for wearable type acute myocardial infarction system. Proc. IEEE Sensors, Baltimore, USA, 3-6 November 2013; 1-4.
[29]
Chung WY, Lee YD, Jung SJ. A wireless sensor network compatible wearable u-healthcare monitoring system using integrated ECG, accelerometer and SpO2. Proc.IEEE Engineering in Medicine and Biology Society, Vancouver, Canada, 20-25 August 2008; 1529-1532.
[30]
Studdert DM, Mello MM, Brennan TA. Medical monitoring for pharmaceutical injuries: tort law for the public's health? The Journal of the American Medical Association 2003; Volume 289: pp.889-894.
[31]
Ortiz, Enrique C, Timo K. NFC, 2014, "http://en.wikipedia.org/wiki/Near_field_communication"
[32]
Taoufik G. How NFC can to speed Bluetooth transactions-today, 2006, "http://www.eetimes.com/document.asp?doc_id=1273409"
[33]
Naumann H. Bluetooth-low-energy and nfc and wifi compare, 2012, "http://www.slideshare.net/droidcon/bluetooth-bluetoothlowenergyantnfcwificompare"
[34]
Park JG, Park KH. Advanced pulse oximetry system for remote monitoring and management. Journal of Biomedicine and Biotechnology 2012; Volume 2012: pp.1-8.
[35]
Aldous SJ. Cardiac biomarkers in acute myocardial infarction. International Journal of Cardiology 2013; Volume 164: pp.282-294.
[36]
Jung JH. Myocardial infarction diagnosis system technical document, 2013, "http://ifrc.chosun.ac.kr/board_NCxI92/8883"
[37]
Hwang H, Hong SI. A reference model for commercializing IT-based convergence technology in the u-health service. Proc. IEEE Technology Management in the IT-Driven Services, San Jose, USA 28 August 2013; 867-870.
[38]
Lim JH, Park CY, Park SJ, Lee KC. ISO/IEEE 11073 PHD generation toolkit to standardize healthcare device. Proc. IEEE Engineering in Medicine and Biology Society, Boston, USA 30 August-3 September 2011; 1161-1164.
[39]
Wilgen U, Pretorius CJ, Ungerer JP. Improved sensitivity of point of care Troponin I values using reporting to below 99th percentile of normal. Clinical Biochemisty 2013; Volume 46: pp.1774-1775.
  1. A smartphone-based U-Healthcare system for real-time monitoring of acute myocardial infarction

      Recommendations

      Comments

      Information & Contributors

      Information

      Published In

      cover image International Journal of Communication Systems
      International Journal of Communication Systems  Volume 28, Issue 18
      December 2015
      87 pages
      ISSN:1074-5351
      EISSN:1099-1131
      Issue’s Table of Contents

      Publisher

      John Wiley and Sons Ltd.

      United Kingdom

      Publication History

      Published: 01 December 2015

      Author Tags

      1. IEEE 11073 protocol
      2. U-Healthcare
      3. acute myocardial infarction
      4. diagnosis
      5. mobile phone
      6. monitoring

      Qualifiers

      • Article

      Contributors

      Other Metrics

      Bibliometrics & Citations

      Bibliometrics

      Article Metrics

      • 0
        Total Citations
      • 0
        Total Downloads
      • Downloads (Last 12 months)0
      • Downloads (Last 6 weeks)0
      Reflects downloads up to 15 Jan 2025

      Other Metrics

      Citations

      View Options

      View options

      Media

      Figures

      Other

      Tables

      Share

      Share

      Share this Publication link

      Share on social media