Abstract
The sensitivity of quantum magnetometer is challenged by control errors and, especially in the solid state, by their short coherence times. Refocusing techniques can overcome these limitations and improve the sensitivity to periodic fields, but they come at the cost of reduced bandwidth and cannot be applied to sense static or aperiodic fields. Here we experimentally demonstrate that continuous driving of the sensor spin by a composite pulse known as rotary-echo yields a flexible magnetometry scheme, mitigating both driving power imperfections and decoherence. A suitable choice of rotary-echo parameters compensates for different scenarios of noise strength and origin. The method can be applied to nanoscale sensing in variable environments or to realize noise spectroscopy. In a room-temperature implementation, based on a single electronic spin in diamond, composite-pulse magnetometry provides a tunable trade-off between sensitivities in the μTHzâ1/2 range, comparable with those obtained with Ramsey spectroscopy, and coherence times approaching T1.
Similar content being viewed by others
Introduction
Solid-state quantum sensors attract much attention given their potential for high sensitivity and nano applications. In particular, the electronic spin of the nitrogen-vacancy (NV) colour centre in diamond is a robust quantum sensor1,2,3 owing to a combination of highly desirable properties: optical initialization and readout, long coherence times at room temperature (T1>2âms (refs 4,5), T20.5âms (ref. 6)), the potential to harness the surrounding spin bath for memory and sensitivity enhancement7,8 and biocompatibility9.
Magnetometry schemes based on quantum spin probes (qubits) usually measure the detuning Î´Ï from a known resonance. The most widely used method is Ramsey spectroscopy10, which measures the relative phase δÏt the qubit acquires when evolving freely after preparation in a superposition state. In the solid state, a severe drawback of this scheme is the short free-evolution dephasing time, T2*, which limits the interrogation time. Dynamical decoupling (DD) techniques, such as Hahn-echo11 or CarrâPurcellâMeiboomâGill12 sequences, can extend the coherence time. Unfortunately, such schemes also refocus the effects of static magnetic fields and are thus not applicable for DC magnetometry. Even if Î´Ï oscillates with a known frequency (AC magnetometry), DD schemes impose severe restrictions on the bandwidth, as the optimal sensitivity is reached only if the field period matches the DD cycle time1. Schemes based on continuous driving are thus of special interest for metrology in the solid state, because they can lead to extended coherence times13. Recently, DC magnetometry based on Rabi frequency beats was demonstrated14; in that method, a small detuning along the static magnetic field produces a shift â(δÏ2)/(2Ω) of the bare Rabi frequency Ω. Despite ideally allowing for interrogation times approaching T1, limiting factors such as noise in the driving field14 and the bad scaling in δÏ<<Ω make Rabi-beat magnetometry unattractive. More complex driving modulations15 can provide not only a better refocusing of driving field inhomogeneities, but also different scalings with δÏ, yielding improved magnetometry. In this work, we use a novel composite-pulse magnetometry method as a means of both extending coherence times as expected by continuous excitation, and keeping a good scaling with δÏ, which increases sensitivity. The -rotary-echo (RE) is a simple composite pulse (Fig. 1a) designed to correct for inhomogeneities in the excitation field16; here, parametrizes the rotation angle of the half-echo pulse. For â 2Ïk, , RE does not refocus magnetic fields along the qubit quantization axes and can therefore be used for DC magnetometry. For =2Ïk, RE provides superior decoupling from both dephasing17,18,19 and microwave noise and can be used to achieve AC magnetometry20.
Results
Dynamics under RE sequence
In the rotating frame associated with the microwave field, and applying the rotating wave approximation, the Hamiltonian describing a continuous stream of -REs is
where is the square wave of period T=2/Ω. On resonance (δÏ=0) the evolution is governed by the propagator , with the triangular wave representing the integral of . We approximate the time evolution in the presence of a detuning Î´Ï by a first-order Average Hamiltonian expansion21 of equation (1), yielding an effective Hamiltonian over the cycle (Supplementary Methods)
Extending the approximation in equation (2) to include the fast Rabi-like oscillations of frequency ÏΩ/( mod 2Ï), we can thus calculate the population evolution for one of the qubit states,
The signal reveals the presence of two spectral lines at for a detuning δÏ.
Sensitivity of the method
Thanks to the linear dependence on δÏ, we expect a favourable scaling of the sensitivity η, given by the shot-noise-limited magnetic field resolution per unit measurement time1,22. For N measurements and a signal standard deviation , the sensitivity is
where γe (â2.8âMHzGâ1 for NV) is the sensor gyromagnetic ratio and ÎB is the minimum detectable field. We broke down the total measurement time into interrogation time t and the dead-time td required for initialization and readout. In the absence of relaxation, and neglecting td, a RE-magnetometer interrogated at complete echo cycles t=n(2/Ω) yields . As shown in Fig. 1b, RE magnetometry has thus sensitivities comparable to Ramsey spectroscopy, ηRamâ1/(γe). Conversely, Rabi-beat magnetometry has at large times (Supplementary Methods), which makes it unsuitable for magnetometry despite long coherence times.
To establish the sensitivity limits of RE magnetometry and compare them with other DC-magnetometry strategies, we carried out proof-of-principle experiments in single NV centres in a bulk electronic-grade diamond sample. A static magnetic field B||â100âG effectively singles out a qubit {|0,|1} from the NV ground-state spin triplet, as the Zeeman shift lifts the degeneracy between the |±1 levels. The qubit is coupled to the spin-1 14N nucleus that composes the defect by an isotropic hyperfine interaction of strength Aâ2Ï Ã 2.17âMHz. After optical polarization into state |0, we apply a stream of n RE cycles using microwaves with frequency Ï close to the qubit resonance Ï0=Î+γeB||, where Î=2.87âGHz is the NV zero-field splitting. Because of the hyperfine coupling, Ï0 is the resonance frequency only when the nuclear state is mI=0. At room temperature, the nitrogen nucleus is unpolarized and, while its state does not change over one experimental run, in the course of the N~106 experimental realizations, â2/3 of the times the qubit is off-resonantly driven by |δÏ|=A. A typical n-cycle RE fluorescence signal is plotted in Fig. 1c for =Ï and Ωâ2Ï Ã 17âMHz, while to determine the frequency content of the signal we plot the periodogram (Supplementary Methods) in Fig. 2.
The number of distinguishable frequencies increases with interrogation time at the expense of signal-to-noise ratio. RE magnetometry not only discriminates the frequency shifts due to the hyperfine interaction (we find Aâ2Ï Ã (2.14±0.03) MHz but, for interrogation times as short as 5âμs, it also reveals a small residual detuning bâ2Ï Ã (0.17±0.02) MHz from the presumed resonance. In contrast, under the same experimental conditions, Rabi magnetometry does not discern such a detuning before an interrogation time â188âμs (Supplementary Methods, and Supplementary Fig. S1). With longer interrogation times ~15âμs as in Fig. 2b (also in Supplementary Fig. S2), RE can detect a frequency as small as bâ2Ï Ã (64±12) kHz.
To determine the experimental sensitivities, we estimate by driving the qubit with varying Ï, at fixed interrogation times t (Fig. 3a). For each t, in Fig. 3b we plot the minimum and compare it with the adjusted theoretical sensitivity η/(C à CA). Here, (C à CA)â(5.9±1.4) à 10â3 in our setup, is a factor taking into account readout inefficiencies and a correction for the presence of the hyperfine interaction1 (see also Supplementary Methods). The sensitivities agree with the theoretical model, with optimal ~10âμTHzâ1/2, which is within the range of sensitivities achieved with other magnetometry schemes alternative to Ramsey23,24, and with the added flexibility made possible by a suitable choice of RE rotation angle. Improved sensitivities are expected from isotopically purified diamond25; an adequate choice of interrogation times or polarization of the nuclear spin can easily set CA=1, while C can be improved by efficient photon collection26 or using repeated readout methods27.
Effect of noise
The sensitivity of a NV magnetometer is ultimately limited by the interaction of the quantum probe with the nuclear spin bath. We model the effect of the spin bath by a classical noise source along Ïz (ref. 28), described by an OrnsteinâUhlenbeck (OU) process of strength Ï and correlation time Ïc. In the limit of long Ïc (static bath), the dephasing time associated with RE (Ramsey) magnetometry is () respectively (for the general case, see Supplementary Methods, and Supplementary Fig. S5a). Although at the optimum interrogation time Tâ²/2 one has , RE magnetometry allows a greater flexibility in choosing the effective coherence time, as larger ν increase the resilience to bath noise. Thus, one can match the RE interrogation time to the duration of the field one wants to measure.
In addition, RE can yield an overall advantage when taking into consideration the dead-time td. If , as in repeated readout methods27, a gain in sensitivity can be reached by exploiting the longer interrogation times enabled by RE magnetometry (Supplementary Methods, and Supplementary Fig. S6). An even larger advantage is given by AC magnetometry with 2Ïk-RE20, as RE provides better protection than pulsed DD schemes17,20.
Excitation field instabilities along Ïx also accelerate the decay of RE and Rabi signals. However, provided the echo period is shorter than Ïc, RE magnetometry corrects for stochastic noise in Rabi frequency (Supplementary Methods, and Supplementary Fig. S5b). This protection was demonstrated experimentally by applying static and OU noise (Ïcâ200âns) in the excitation microwave, both with strength 0.05âΩ. The results for Rabi and ={Ï, 5Ï}-RE sequences in Fig. 4 clearly show that whereas the Rabi signal decays within â0.5âμs, 5Ï-RE refocuses static excitation noise and presents only a very weak decay under finite-correlation noise after much longer interrogation times â3âμs, in agreement with the theoretical prediction; Ï-RE is robust against the same noise profiles.
Discussion
The unique ability of the RE-magnetometer to adjust its response to distinct noise sources is relevant when the sample producing the magnetic field of interest is immersed in a realistic environment; moreover, the field source might itself have a finite duration or duty cycle. Most experimentally relevant fields, such as those arising from biological samples, might last only for a finite amount of time, when triggered, or be slowly varying so that one can only record their time-average. Thus, it becomes interesting to be able to tune the interrogation time in order to capture and average over the complete physical process. The advantage is two-fold: the protection from noise can be tuned by changing the echo angle, thus allowing the interrogation times to be varied. Techniques for repeated readout in the presence of a strong magnetic field 1,000âG (ref. 27) (also Supplementary Methods) can at once improve sensitivities and enable the use of much lower qubit resonance frequencies ~MHz, preferable in biological settings.
Additionally, a RE-magnetometer can discriminate magnetic noise sources given the sensorâs well-understood decoherence behaviour under different noise profiles, effectively enabling noise spectroscopy for both Ïz and Ïx-type noises.
NV centre-based RE magnetometry could find useful application, for example, to sense the activity of differently-sized calcium signalling domains in living cells, more specifically in neurons. Transient calcium fluxes regulate a myriad of cell reactions29. The signalling specificity of such fluxes is determined by their duration and mean travelled distance between membrane channel and cytoplasm receptor. The smaller, faster-signalling domains have resisted thorough investigation via both diffraction-limited optical microscopy29, and the use of fluorescing dyes, which do not respond fast or accurately enough to Ca2+ transients30. The magnetic field produced by as few as 105 Ca2+, being diffused within ~10âμs through a ~200-nm domain, can be picked up by a nanodiamond scanning sensor31,32 with sensitivity ~10âμTHzâ1/2 placed at close proximity ~10ânm (Supplementary Methods). The trade-off between sensitivity and optimal interrogation time under RE magnetometry can be optimized to the characteristics of the signalling domain under study by a suitable choice of .
In conclusion, we have demonstrated a quantum magnetometry scheme based on composite pulses. Its key interest stems both from the continuous-excitation character, offering superior performance for solid state sensors such as the NV centre, and from the possibility of tuning the sensorâs coherence time and sensitivity in the presence of variable or unknown sensing environments, to protect from or map noise sources. Current technology enables immediate implementation of such scheme at the nanoscale.
Methods
Quantum magnetometer description
The NV centre is a naturally occurring point defect in diamond, composed of a vacancy adjacent to a substitutional nitrogen in the carbon lattice. The ground state of the negatively charged NV centre is a spin triplet with zero-field splitting Î=2.87âGHz between the mS=0 and mS=±1 sub-levels. Coherent optical excitation at 532ânm promotes the quantum state of the defect non-resonantly to the first orbital excited state. Although the mS=0 state mostly relaxes with phonon-mediated fluorescent emission (â650â800ânm), the mS=±1 states have in addition an alternative, non-radiative decay mode to the mS=0 state via metastable singlet states. Owing to this property, each ground state is distinguishable by monitoring the intensity of emitted photons during a short pulse of optical excitation. Additionally, continuous optical excitation polarizes the NV into the mS=0 state. We apply a magnetic field (â100âG) along a crystal axis 111 to lift the degeneracy between the mS=±1 states and drive an effective two-level system mS={0,1} at the resonant frequency (Ï0â3.15âGHz) obtained by continuous wave electron spin resonance and Ramsey fringe experiments.
Experimental setup description
Experiments were run at room-temperature with single NV centres from an electronic-grade single crystal plate ([100] orientation, Element 6) with a substitutional nitrogen concentration <5âppb. The fluorescence of single NV centres is identified by a home-built confocal scanning microscope. The sample is mounted on a piezo stage (Nano-3D200, Mad City Labs). The excitation at 532ânm is provided by a diode-pumped laser (Coherent Compass 315M), and fluorescence in the phonon sideband (~650â800ânm) is collected by a X100, NA=1.3 oil immersion objective (Nikon Plan Fluor). The fluorescence photons are collected into a single-mode broadband fibre of NA=0.12 (Font Canada) and sent to a single-photon counting module (SPCM-AQRH-13-FC, Perkin Elmer) with acquisition time 100 or 200âns.
Laser pulses for polarization and detection are generated by an acousto-optic modulator with rise time 7âns (1250C-848, Isomet). A signal generator (N5183A-520, Agilent) provides microwave fields to coherently manipulate the qubit. An arbitrary waveform generator at 1.2âGS/s (AWG5014B, Tektronix) is employed to shape microwave pulses with the help of an I/Q mixer (IQ-0318L, Marki Microwave), and to time the whole experimental sequence. Microwaves are amplified (GT-1000A, Gigatronics) and subsequently delivered to the sample by a copper microstrip mounted on a printed circuit board, fabricated in MACOR to reduce losses.
A static magnetic field is applied by a permanent magnet (BX0X0X0-N52, K&J Magnetics) mounted on a rotation stage, which in turn is attached to a three-axis translation stage; this arrangement enables the adjustment of the magnetic field angle with respect to the sample. The magnetic field is aligned along a [111] axis by maximizing the Zeeman splitting in a CW ESR spectrum.
In each experimental run, we normalize the signal with respect to the reference counts from the mS={0,1} states, where the transfer to state mS=1 is done by adiabatic passage.
Additional information
How to cite this article: Aiello, C. D. et al. Composite-pulse magnetometry with a solid-state quantum sensor. Nat. Commun. 4:1419 doi: 10.1038/ncomms2375 (2013).
References
Taylor J. M. et al. High-sensitivity diamond magnetometer with nanoscale resolution. Nat. Phys. 4, 810â816 (2008) .
Maze J. R. et al. Nanoscale magnetic sensing with an individual electronic spin qubit in diamond. Nature 455, 644â647 (2008) .
Balasubramanian G. et al. Magnetic resonance imaging and scanning probe magnetometry with single spins under ambient conditions. Nature 445, 648â651 (2008) .
Jarmola A., Acosta V. M., Jensen K., Chemerisov S. & Budker D. . Temperature- and magnetic-field-dependent longitudinal spin relaxation in nitrogen-vacancy ensembles in diamond. Phys. Rev. Lett. 108, 197601 (2012) .
Waldherr G. et al. High-dynamic-range magnetometry with a single nuclear spin in diamond. Nat. Nanotech. 7, 105â108 (2012) .
Childress L. et al. Coherent dynamics of coupled electron and nuclear spin qubits in diamond. Science 314, 281â285 (2006) .
Cappellaro P. et al. Environment-assisted metrology with spin qubits. Phys. Rev. A 85, 032336 (2012) .
Goldstein G. et al. Environment-assisted precision measurement. Phys. Rev. Lett. 106, 140502 (2011) .
McGuinness L. P. et al. Quantum measurement and orientation tracking of fluorescent nanodiamonds inside living cells. Nat. Nanotech. 6, 358â363 (2011) .
Ramsey N. F. . Molecular Beams Oxford University (1990) .
Hahn E. L. . Spin echoes. Phys. Rev. 80, 580â594 (1950) .
Meiboom S. & Gill D. . Modified spin-echo method for measuring nuclear relaxation times. Rev. Sc. Instr. 29, 688 (1958) .
Kosugi N., Matsuo S., Konno K. & Hatakenaka N. . Theory of damped Rabi oscillations. Phys. Rev. B 72, 172509 (2005) .
Fedder H. et al. Towards T1-limited magnetic resonance imaging using Rabi beats. Appl. Phys. B 102, 497â502 (2011) .
Levitt M. H. . Composite pulses. Prog. Nucl. Mag. Res. Spect. 18, 61â122 (1986) .
Solomon I. . Multiple echoes in solids. Phys. Rev. 110, 61â65 (1958) .
Laraoui A. & Meriles C. A. . Rotating frame spin dynamics of a nitrogen-vacancy center in a diamond nanocrystal. Phys. Rev. B 84, 161403 (2011) .
Cai J. -M. et al. Robust dynamical decoupling with concatenated continuous driving. New J. Phys. 14, 113023 (2012) .
Xu X. et al. Coherence-protected quantum gate by continuous dynamical decoupling in diamond. Phys. Rev. Lett. 109, 070502 (2012) .
Hirose M., Aiello C. D. & Cappellaro P. . Continuous dynamical decoupling magnetometry. Phys. Rev. A. 86, 062320 (2012) .
Haeberlen U. . High Resolution NMR in Solids: Selective Averaging Academic Press, (1976) .
Wineland D. J., Bollinger J. J., Itano W. M., Moore F. L. & Heinzen D. J. . Spin squeezing and reduced quantum noise in spectroscopy. Phys. Rev. A 46, R6797 (1992) .
Schoenfeld R. S. & Harneit W. . Real-time magnetic field sensing and imaging using a single spin in diamond. Phys. Rev. Lett. 106, 030802 (2011) .
Dréau A. et al. Avoiding power broadening in optically detected magnetic resonance of single NV defects for enhanced DC magnetic field sensitivity. Phys. Rev. B 84, 195204 (2011) .
Balasubramanian G. et al. Ultralong spin coherence time in isotopically engineered diamond. Nat. Mater. 8, 383â387 (2009) .
Babinec T. M. et al. A diamond nanowire single-photon source. Nat. Nanotech. 5, 195â199 (2010) .
Neumann P. et al. Single-shot readout of a single nuclear spin. Science 5991, 542â544 (2010) .
Klauder J. R. & Anderson P. W. . Spectral diffusion decay in spin resonance experiments. Phys. Rev. 125, 912â932 (1962) .
Augustine G. J., Santamaria F. & Tanaka K. . Local calcium signaling in neurons. Neuron 40, 331â346 (2003) .
Keller D. X., Franks K. M., Bartol T. M. Jr & Sejnowski T. J. . Calmodulin activation by calcium transients in the postsynaptic density of dendritic spines. PLoS ONE 3, e2045 (2008) .
Degen C. L. . Scanning magnetic field microscope with a diamond single-spin sensor. Appl. Phys. Lett. 92, 243111 (2008) .
Grinolds M. S., Maletinsky P., Hong S., Lukin M. D., Walsworth R. L. & Yacoby A. . Quantum control of proximal spins using nanoscale magnetic resonance imaging. Nat. Phys. 7, 687â692 (2011) .
Wei W. W. S. . Time Series Analysis: Univariate and Multivariate Methods Pearson Addison Wesley, (2006) .
Jacques V. et al. Dynamic polarization of single nuclear spins by optical pumping of nitrogen-vacancy color centers in diamond at room temperature. Phys. Rev. Lett. 102, 057403 (2009) .
Acknowledgements
C.D.A. thanks Boerge Hemmerling, Michael G. Schmidt and Marcos Coque Jr. for stimulating discussions. This work was supported in part by the US Army Research Office through a MURI grant No. W911NF-11-1-0400 and by DARPA (QuASAR programme). C.D.A. acknowledges support from the Schlumberger Foundation.
Author information
Authors and Affiliations
Contributions
C.D.A., M.H. and P.C. conceived the experiment and performed the theoretical analysis. C.D.A. and M.H. carried out the measurements and analysis of the data. All authors discussed the results and contributed to the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Supplementary Information
Supplementary Figures S1-S6, Supplementary Methods and Supplementary References (PDF 1059 kb)
Rights and permissions
About this article
Cite this article
Aiello, C., Hirose, M. & Cappellaro, P. Composite-pulse magnetometry with a solid-state quantum sensor. Nat Commun 4, 1419 (2013). https://doi.org/10.1038/ncomms2375
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/ncomms2375
This article is cited by
-
NMR Hamiltonian as an effective Hamiltonian to generate Schrödingerâs cat states
Quantum Information Processing (2022)
-
Optimal control for quantum detectors
npj Quantum Information (2021)
-
Design and simulation of a strong and uniform microwave antenna for a large volume of nitrogen-vacancy ensembles in diamond
Journal of the Korean Physical Society (2021)
-
Dynamical sensitivity control of a single-spin quantum sensor
Scientific Reports (2017)
-
Highly selective detection of individual nuclear spins with rotary echo on an electron spin probe
Scientific Reports (2015)