Abstract
Novel table-top sources of extreme-ultraviolet light based on high-harmonic generation yield unique insight into the fundamental properties of molecules, nanomaterials or correlated solids, and enable advanced applications in imaging or metrology. Extending high-harmonic generation to high repetition rates portends great experimental benefits, yet efficient extreme-ultraviolet conversion of correspondingly weak driving pulses is challenging. Here, we demonstrate a highly-efficient source of femtosecond extreme-ultraviolet pulses at 50-kHz repetition rate, utilizing the ultraviolet second-harmonic focused tightly into Kr gas. In this cascaded scheme, a photon flux beyond â3 Ã 1013âsâ1 is generated at 22.3âeV, with 5 Ã 10â5 conversion efficiency that surpasses similar harmonics directly driven by the fundamental by two orders-of-magnitude. The enhancement arises from both wavelength scaling of the atomic dipole and improved spatio-temporal phase matching, confirmed by simulations. Spectral isolation of a single 72-meV-wide harmonic renders this bright, 50-kHz extreme-ultraviolet source a powerful tool for ultrafast photoemission, nanoscale imaging and other applications.
Similar content being viewed by others
Introduction
Unique table-top sources of spatially and temporally coherent X-rays are enabled by high-harmonic generation (HHG), which is based on strong-field ionization, acceleration and recombination of electrons in intense laser fields exceeding 1013âWâcmâ2 (refs 1, 2, 3, 4). Generally, HHG is driven by energetic, mJ-scale lasers operating at low repetition ratesâfrom a few Hz to several kHzâthat allow for loose focusing to maximize phase-matching and thus the conversion efficiency5,6. Extending table-top extreme-ultraviolet (XUV) sources with ample flux towards rates of â50âkHz and beyond is difficult, but can dramatically advance both fundamental investigations of matter and applications in metrology or imaging. For instance, high repetition rates are critical to coincidence and time-of-flight spectroscopy of molecules and solids7,8, and can also boost photoemission-based imaging and time-resolved studies where electron space-charge effects require spreading the flux over many pulses9,10,11,12,13,14,15,16,17. Material studies in particular require a narrow bandwidth (â²100âmeV) to discern the electronic structure, and â1013âphotonsâsâ1 (phâsâ1) HHG source flux before spectral selection for acquisition times comparable to static synchrotron-based photoemission14,18. Efficient high-repetition-rate HHG, however, is challenging due to the difficulty of phase-matching the conversion in a tight laser focus, necessary to achieve strong-field conditions with μJ-level driving pulses. XUV generation directly from 50 to 100âkHz Ti:sapphire amplifiers so far resulted in â10â8 conversion efficiency and a flux up to â3 à 109âphâsâ1 per harmonic19,20,21.
Different schemes have been pursued to address this challenge, encompassing a large range of approaches that start from high (50â100âkHz) and extend up to ultra-high (multi-MHz) repetition rates. The latter were enabled by increasing the repetition rate thousand-fold via intra-cavity HHG in enhancement resonators, which boosts the average XUV power despite limited (â10â11â10â7) conversion efficiencies22,23. An optimized setup delivers 1012â1013âphâsâ1 harmonic flux around 50âMHz (ref. 24). Although ideal for XUV frequency-comb metrology, these oscillator-based schemes are unsuited to ultrafast studies requiring strong excitation pulses and continuous operation is limited by hydrocarbon contamination at kW intra-cavity powers. Alternatively, high-repetition-rate HHG directly with intense driving pulses is enabled by Yb-based solid-state or fibre amplifiers that withstand high average powers25,26,27. At 100âkHz repetition rate, 1012âphâsâ1 were generated, which corresponds to â5 Ã 10â7 efficiency26. Scaling up to 0.6âMHz was achieved by combining the output of multiple fibre amplifiers to 163âW power, yielding more than 1013âphâsâ1 flux with up to 2 Ã 10â6 efficiency28. Recently, the absorption limit of infrared-driven HHG was reached using 8âfs pulses and gas pressures up to several bar, yielding broad harmonics with 8 Ã 10â6 efficiency and â2 Ã 1012âphâsâ1 flux at 150âkHz (ref. 29). In this context, further enhancement of high-repetition-rate HHG motivates the investigation of methods to boost the conversion process itself. Below-threshold harmonics represent one possibility, where phase matching near atomic resonances enables efficient, yet spectrally broad and structured emission30. A second, highly interesting route arises from strong wavelength scaling of the HHG atomic dipole, evidenced at low repetition rates by increased XUV flux resulting from mJ-scale, visible and ultraviolet pulses loosely focused for optimal phase matching31,32,33,34. Efficient HHG with short-wavelength sources, however, has so far not been demonstrated under high-repetition-rate conditions, and HHG sources are not typically optimized to generate spectrally narrow harmonics.
Here, we explore ultraviolet-driven HHG in the tight-focusing regime and establish a highly-efficient source of narrowband XUV pulses at 50-kHz repetition rate. A bright harmonic flux of â3 Ã 1013âphâsâ1 is generated at 22.3âeV in this cascaded approach, where efficient frequency doubling is followed by HHG in Kr gas. We establish an XUV conversion efficiency of up to â5 Ã 10â5, which exceeds by two orders-of-magnitude that of similar harmonics driven directly by the near-infrared laser amplifier. This strong boost surpasses the dipole wavelength scaling and, as confirmed by numerical simulations, evidences enhanced spatio-temporal phase matching for ultraviolet-driven harmonics in the sharply focused beam. The spectral structure enables direct isolation of a single, 72-meV wide harmonicâyielding a compact and bright, high-repetition-rate XUV source for a new class of ultrafast XUV studies.
Results
High-repetition-rate XUV generation
Our scheme is illustrated in Fig. 1a. Near-infrared pulses of 120âμJ energy and 50-fs duration are generated by a cryogenically cooled, high-repetition-rate (50âkHz) Ti:sapphire regenerative amplifier, and focused onto a 0.5-mm-thick β-Barium borate (BBO) crystal for frequency doubling with â40% efficiency. Here, loose focusing with a f=1âm focal length lens avoids nonlinear spectral broadening and ionization in the air. This results in ultraviolet pulses centred around 390ânm wavelength with 48âμJ pulse energy, which are separated from the fundamental via two dichroic multilayer mirrors. To initiate the HHG process, the femtosecond ultraviolet pulses are recollimated and subsequently focused sharply via a f=175âmm lens onto a cylindrical gas cell, consisting of an end-sealed glass capillary housed in a vacuum chamber. The capillary is supplied with Kr gas and positioned near the focus of the second-harmonic laser beam, while suppressing the production of off-axis beams arising from long-trajectory electron dynamics35.
Under these conditions we observe the emission of strong XUV harmonics. Their spectral content is characterized by a spectrometer after blocking the diverging optical beam with thin aluminum filters (see Methods). Figure 1b (top image) shows the resulting charge-coupled device (CCD) readout for a gas pressure of 60âTorr. Bright peaks are detected around 22.3 and 28.6âeV, respectively, corresponding to the 7th and 9th harmonics of the ultraviolet driving pulses. For direct comparison, we also recorded the XUV emission generated by directly focusing the â780ânm fundamental pulses onto the Kr gas to a similar peak intensity. Multiple harmonics are observed, as shown in the corresponding normalized CCD data in Fig. 1b (bottom image). However, the emission was found to be significantly weaker compared with the ultraviolet-driven harmonics.
Figure 1c shows the dependence of the XUV intensity of the most intense harmonic on the backing pressure of the Kr gas target, indicating a rapid nonlinear increase up to about 60âTorr followed by saturation at higher pressures. The strong XUV emission arises from phase-matched harmonic generation, because of in-phase coherent addition of the XUV fields emitted from the Kr atoms. At higher pressures, plasma defocusing limits the overall yield20,36,37. We have also generated harmonics in Ar gas for comparison, resulting however in â5 times lower yield. For optimal phase-matching in Kr, the vertical intensity contour on the CCD image (Fig. 1b) perpendicular to the dispersion direction indicates an approximately Gaussian beam profile. From its extent, we obtain a beam divergence of 6âmrad (full-width at half-maximum, FWHM), which facilitates extended beam propagation for refocusing or additional optical manipulations.
Spectral structure and harmonic flux
The experiments reveal a striking enhancement of the XUV emission generated by the 390-nm field as compared with that obtained from the near-infrared fundamental. Figure 2a compares the measured XUV spectra for the same integration time, corrected for an additional Al filter used to avoid CCD saturation. The spectra encompass a series of odd harmonics that span photon energies up to â37âeV with strongly varying peak intensities, where the 7th harmonic of the ultraviolet field constitutes by the far strongest XUV emission. The latter, ultraviolet-driven peak at â22.3âeV surpasses that of the spectrally similar 13th and 15th harmonics of the near-infrared fundamental by 50â80 times. This strong enhancement is particularly striking, as it occurs despite the necessarily lower energy of the ultraviolet pulses derived from frequency doubling. Importantly, this harmonic exhibits a linewidth as narrow as 72âmeV FWHM near optimum pressure, as shown in Fig. 2b. This yields a critical advantage for applications such as photoelectron spectroscopy or zone-plate imaging.
The ultraviolet-driven XUV generation entails a large energy separation of â6.4âeV between the individual odd harmonics. We can exploit this distinctive feature to isolate a single harmonic from the comb, taking advantage of the atomic and plasma absorption edges of thin metal foils. To select harmonics around 22âeV, the beam is passed through 300-nm-thick Sn, whose transmission is indicated by the dashed line in Fig. 2c and which strongly attenuates the adjacent 5th and 9th harmonics. Together with the Al foil used to block the residual visible beam, for a combined XUV transmission of â1%, we obtain the spectrum in Fig. 2c (magenta line). In this scheme, the 5th and 3rd harmonics at lower energies are also suppressed via the Al foil that blocks the ultraviolet driving field. By attenuating the laser beam instead via two Brewsterâs-angle reflections from silicon38, the lower-order harmonics are transmitted. The 5th harmonic at 15.9âeV is then spectrally selected using a 300-nm-thick In foil, as demonstrated in Fig. 2c (green line), with a flux and bandwidth comparable to the isolated q=7 harmonic. Thus, high-contrast isolation of individual ultraviolet-driven harmonics is achieved at either 15.9 or 22.3âeV, resulting in a compact source of narrowband and single-harmonic XUV pulses without the need for a complex monochromator.
To obtain the absolute XUV photon flux for each harmonic, the total source power was determined with a calibrated X-ray photodiode, taking into account the filter transmission, and then split according to the harmonic ratios (see Methods). Table 1 shows the photon flux of the individual harmonics and resulting energy conversion efficiencies. Up to 3.3 à 1013âphâsâ1 are generated in the 7th harmonic of the ultraviolet-driving pulses, corresponding to 117âμW source power emitted from the Kr gas at 22.3âeV. The corresponding HHG efficiency (5 à 10â5) is â140â400 times higher than for the spectrally closeby 15th and 13th harmonics of the fundamental. The values must be compared at similar photon energies due to the wavelength-dependent opacity of the gas39. By contrast, when the influence of phase-matching can be neglected, a scaling âλ0â4.7±1 with visible driver wavelength was previously found40, which contributes a â12 to 52-fold increase upon frequency doubling of λ0. This comparison underscores the significant phase-matching advantage of the ultraviolet-driven HHG under our experimental conditions.
Phase-matching simulations of ultraviolet-driven HHG
In the following, we present numerical HHG simulations to clarify the phase-matching boost of ultraviolet-driven HHG with our experimental parameters. The generated number of XUV photons in the q-th harmonic can be expressed as37 NqâβS(q,Ï0) à ξq. Here, βS is the single-atom efficiency due to electronic wavepacket dynamics, which approximately follows βSâÏ05 around the cutoff due to wavepacket quantum diffusion and energy scaling41. In turn, ξq is the enhancement factor arising from the spatio-temporal folding of XUV emission and phase matching5,37. In the simulation, the XUV flux generated from each temporal slice of the driving field results from the coherent superposition of all harmonic emissions, integrated across the interaction volume5. For this, we take into account the XUV generation at each location z, reabsorption by the Kr gas, ground state depletion and the wavevector mismatch between the high-harmonic and driving fields
The first two terms above describe the mismatch due to dispersion at a given pressure, where ÎkN corresponds to the charge-neutral gas and ÎkP to a fully ionized plasma, accordingly scaled by the ionization level η. Moreover, ÎkD results from the atomic dipole phase accumulated by the accelerated electron wavepacket, and ÎkG from the geometric Gouy phase of the focused beams.
For loose focusing attainable with mJ pulses, the spatial dependence and Gouy-phase contribution are negligible. Phase matching is then achieved at suitable pressures by dynamically balancing to Îkâ0 via the ionization level, given that the sign of the plasma contribution (ÎkP>0) is opposite to ÎkN of neutral atoms. Such conditions are fulfilled only during part of the driving pulse, as the ionization level rises quickly with time3. Instead, under tight focusing where the Rayleigh length zR is comparable to the gas cell thickness, the conversion efficiency is reduced due to the added spatial dependence of Îk. The Gouy term now becomes significant and as its sign equals the plasma contribution, phase-matching occurs at a lower ionized fraction and thus reduced intensity. Although increased pressures can partly compensate this reduction, the tolerable gas density is limited by plasma defocusing and pumping capabilities36,37,42.
When ultraviolet-driving pulses are employed, the above spatio-temporal effects of phase-matching on the XUV emissionârepresented by the enhancement ξqâare substantially improved. We have calculated phase-matched HHG in Kr gas with the above model under our conditions, for pulses with either 390 or 780ânm centre wavelength and otherwise identical 1.8 à 1014âWâcmâ2 peak intensity and 75-fs duration (for details see Supplementary Methods). To mimic the experiment, we further consider a Rayleigh length of zR=1âmm and a 1-mm-thick gas volume. The driving pulse profile is indicated in Fig. 3a. Figure 3b,c maps the coherence length Lcoh=Ï/|Îk| as a function of gas pressure and time. The Kr ionization levels are shown for comparison (lines in Fig. 3b,c) and ramp up quickly towards the pulse centre. They are calculated with the Yudin-Ivanov model43 to encompass both tunnelling and multi-photon ionization, whose relative influence was illustrated in previous studies of HHG phase-matching and wavelength scaling under loose focusing44. Several aspects contribute to the enhanced phase-matching in the ultraviolet field. First, due to 1/Ï02 scaling of the plasma mismatch, higher ionization levels are tolerated in the ultraviolet as evident from a comparison of Fig. 3b,c. The ionization rates are accordingly higher, and our calculations indicate a â4.2 times enhancement over infrared-driven HHG. Second, the spatial phase matching conditions are also improved, as the Gouy phase is proportional to the harmonic order. As a result, the absolute value and spatial dependence of ÎkG are reduced by half when driven by the second-harmonic. For these ultraviolet-driven enhancements, we note that plasma scaling equally applies to loose focusing, whereas the Gouy phase reduction only matters for tight focusing entailed by limited pulse energies of high-repetition-rate lasers.
To obtain the total XUV flux, we integrate the harmonic emission across the gas volume, taking into account the gas density, XUV emission and re-absorption, and the spatio-temporal dynamics of the ionization level and phase mismatch. Figure 3d,e compares the resulting XUV flux enhancement beyond the single-atom efficiency βS, for the two incident wavelengths and mapped out for different pressures and temporal slices within the driving field. This illustrates the time window of XUV emission and demonstrates the clear phase-matching advantage of ultraviolet-driven HHG. Figure 3f shows the pressure dependence of the integrated XUV flux generated by the ultraviolet field (dotted line). The ratio of the total, time-integrated phase-matching enhancements ξq(UV)/ξq(IR) is shown in Fig. 3f (dashed line). Further improvement is found when considering the shorter â50-fs infrared pulses in the experiment (solid line), resulting in a 10â16 times ultraviolet-driven boost of phase-matched XUV generation below 60âTorr. Combined with the âÏ05 scaling of the single-atom efficiency that contributes an additional factor of 32, this ultraviolet-driven boost of phase-matched XUV generation explains the two orders-of-magnitude increase in HHG efficiency observed in our experiments.
Discussion
The efficient HHG conversion demonstrated here at 50âkHz results in a unique XUV source with major experimental benefits. Beyond enhancing signal averaging and statistics in numerous applications, high repetition rates are particularly valuable to advancing photoemission electron microscopy17 or angle-resolved photoelectron spectroscopy (ARPES)11,13, where space-charge Coulomb interactions between the emitted electrons limit acceptable pulse energies. Moreover, in ARPES the accessible momentum space increases rapidly with photon energy, and XUV photons beyond 20âeV render the full Brillouin zone of most materials easily accessible.
After high-contrast spectral isolation of the 22.3âeV harmonic with the combined Al-Sn filter, our femtosecond source delivers â3 Ã 1011âphâsâ1 at the sample. This flux is comparable to continously emitting Helium lamps and even approaches that of monochromatized synchrotron beamlines employed for static ARPES14,18. As space-charge broadening typically restricts each pulse to â106 photons, the 50-kHz repetition rate at this flux provides ideal conditions for photoemission studies14,45. We note that by utilizing only the Al foil, even higher flux beyond â3 Ã 1012âphâsâ1 is obtained at the expense of isolation contrast. The addition of the Sn filter, however, also provides a compact way to separate the gas-based XUV source and attached optics chambers from a subsequent ultrahigh-vacuum environment.
Spectral isolation and narrowing of high-order harmonics is often achieved using XUV monochromators, which add significant complexity and require non-traditional layouts for time-resolved applications to minimize grating-induced pulse broadening46,47. In contrast, the ultraviolet-driven HHG source reported here demonstrates the direct generation of narrow harmonics, whose large energy spacing allows for straightforward selection with absorptive metal filters. The measured 72-meV harmonic width corresponds to a â0.3% fractional energy bandwidth directly from the source. This intrinsic resolution is well adapted to discerning the electronic structure of atoms, molecules and complex materials via photoemission studies.
Hence, XUV conversion with high efficiency is achieved at 50-kHz repetition rate, resulting from both wavelength scaling of the atomic dipole and enhanced phase-matching conditions in a ultraviolet field under tight focusing conditions. Although based on Ti:sapphire-amplified pulses, this cascaded scheme is generally applicable and attractive for enhancing HHG also with other high-repetition-rate sources. In particular, combining ultraviolet-driven HHG with novel high-power solid-state48 or Yb-fibre amplifiers25,26,28 may help scale XUV generation to even higher flux and repetition rates. Finally, additional narrowing of the harmonics would propel scientific studies of low-energy correlations in solids, which motivates further HHG studies with longer or spectrally shaped ultraviolet fields. We expect that the compact 50-kHz source of bright and narrowband XUV harmonics, established here, will boost applications in photoemission and nanoscale imaging, paving the way for novel insights into complex matter.
Methods
Femtosecond ultraviolet-driving pulses
The initial stage of the setup is a high average power cryo-cooled Ti:sapphire regenerative amplifier (KMLabs Wyvern 500) that provides near-infrared pulses of 50âfs duration at 50-kHz repetition rate, with a high beam quality (M2=1.3 à diffraction limited). After splitting off half of the output for photo-excitation in time-resolved applications, the remaining pulses with â120âμJ energy were focused onto a 0.5-mm-thick BBO crystal with a f=1âm lens. The crystal is cut for phase-matched second-harmonic generation (θ=29.2°) and positioned 380âmm before the focus, corresponding to a peak intensity of â100âGWâcmâ2. We estimate a ultraviolet pulse duration of â73âfs by taking into account nonlinear propagation in BBO (using the code SNLO) and pulse dispersion in the focusing optics. Pulses with 3ânm bandwidth are generated around 390ânm wavelength with â39.5% conversion efficiency.
Generation and spectral characterization of XUV harmonics
For HHG, Kr gas is introduced into the end-sealed glass capillary positioned within a vacuum chamber. Here, a 1-mm inner diameter and 100-μm wall thickness of the capillary was chosen to accomodate the zRâ1âmm Rayleigh length of the driving beam. Before use, beam entry and exit holes are laser-drilled in situ at ambient pressure, perpendicular to the capillary side walls via the femtosecond ultraviolet laser pulses. Under normal operation, a 750âlâsâ1 turbopump maintains the pressure in the HHG chamber below 1âmTorr. The capillary backing pressure is monitored with a Si diaphragm gauge.
For XUV generation, the ultraviolet pulses are re-collimated with a f=1-m fused silica lens and then focused onto the gas cell with a f=175âmm lens, resulting in a 18-μm FWHM beam diameter and I0â1.8 à 1014âWâcmâ2 peak intensity. Using the fundamental for harmonic generation, these values are 33âμm and I0â1.9 à 1014âWâcmâ2. After the generation chamber, the intense driving beam is blocked and the XUV harmonics are spectrally selected via thin metal filters, mounted on two gate valves to enable their insertion. The XUV spectra are recorded with an evacuated spectrometer (McPherson 234/302) equipped with a back-illuminated X-ray CCD and a 2,400âlâmmâ1 Pt-coated aberration-corrected concave grating. The CCD covers the 25â75ânm range (â49.6â16.5âeV) at 50ânm central wavelength, and a 5-μm wide entrance slit is used for â0.1ânm spectral resolution.
XUV photon flux
The absolute photon flux for each harmonic is quantitatively determined by first recording the spectrally integrated XUV flux with a Si photodiode calibrated in this range (IRD AXUV100G), and then splitting this total flux according to the relative ratios of the harmonics. Residual leakage at the drive wavelength is removed by subtracting the background measured without the noble gas. The total charge collected by the photodiode is the sum of contributions from each q-th odd harmonic, that is,
where Eq is the pulse energy within the q-th harmonic as emitted at the source, Ïq is the harmonic frequency, Tf (Ï) is the Al filter transmission and RAXUV(Ï) the calibrated photodiode responsitivity. The Al filter was calibrated in situ by measuring the transmission of near-infrared-driven harmonic peaks on the X-ray CCD (Supplementary Fig. 1), with the foil inserted with a gate valve. The absolute values of Eq are then obtained from QXUV using the relative harmonic ratios. These ratios are determined from the CCD spectrum of the XUV harmonics, corrected for filter transmission and grating efficiency, that is, from the count rate
where ηgr(Ï) is the grating diffraction efficiency provided by the manufacturer and QECCD(Ï) is the CCD quantum efficiency. To avoid saturation of the CCD camera, the XUV flux was suppressed with either n=1 or 2 filters for the infrared- and ultraviolet-driven harmonics, respectively. The above procedure thus provides the pulse energy and the photon flux Eq/ħÏq for each harmonic.
Additional information
How to cite this article: Wang, H. et al. Bright high-repetition-rate source of narrowband extreme-ultraviolet harmonics beyond 22âeV. Nat. Commun. 6:7459 doi: 10.1038/ncomms8459 (2015).
References
Corkum, P. B. Plasma perspective on strong-field multiphoton ionization. Phys. Rev. Lett. 71, 1994â1997 (1993).
Popmintchev, T., Chen, M.-C., Arpin, P., Murnane, M. M. & Kapteyn, H. C. The attosecond nonlinear optics of bright coherent X-ray generation. Nat. Photonics 4, 822â832 (2010).
Chang, Z. Fundamentals of Attosecond Optics CRC (2011).
McPherson, A. et al. Studies of multiphoton production of vacuum-ultraviolet radiation in the rare gases. J. Opt. Soc. Am. B 4, 595â601 (1987).
Constant, E. et al. Optimizing high harmonic generation in absorbing gases: model and experiment. Phys. Rev. Lett. 82, 1668â1671 (1999).
Takahashi, E., Nabekawa, Y. & Midorikawa, K. Generation of 10-μJ coherent extreme-ultraviolet light by use of high-order harmonics. Opt. Lett. 27, 1920â1922 (2002).
Sandhu, A. S. et al. Observing the creation of electronic Feshbach resonances in soft X-rayâinduced O2 dissociation. Science 322, 1081â1085 (2008).
Gotlieb, K., Hussain, Z., Bostwick, A., Lanzara, A. & Jozwiak, C. Rapid high-resolution spin- and angle-resolved photoemission spectroscopy with pulsed laser source and time-of-flight spectrometer. Rev. Sci. Instrum. 84, 093904 (2013).
Haight, R. Electron dynamics at surfaces. Surf. Sci. Rep. 21, 275â325 (1995).
Schmitt, F. et al. Transient electronic structure and melting of a charge density wave in TbTe3 . Science 321, 1649â1652 (2008).
Rohwer, T. et al. Collapse of long-range charge order tracked by time-resolved photoemission at high momenta. Nature 471, 490â493 (2011).
Graf, J. et al. Nodal quasiparticle meltdown in ultrahigh-resolution pumpâprobe angle-resolved photoemission. Nat. Phys. 7, 805â809 (2011).
Gierz, I. et al. Snapshots of non-equilibrium Dirac carrier distributions in graphene. Nat. Mater. 12, 1119â1124 (2013).
Zhou, X. J. et al. Space charge effect and mirror charge effect in photoemission spectroscopy. J. Electron Spectros. Relat. Phenomena 142, 27â38 (2005).
Siefermann, K. R. et al. Binding energies, lifetimes and implications of bulk and interface solvated electrons in water. Nat. Chem. 2, 274â279 (2010).
Suzuki, T. Time-resolved photoelectron spectroscopy of non-adiabatic electronic dynamics in gas and liquid phases. Int. Rev. Phys. Chem. 31, 265â318 (2012).
Chew, S. H. et al. Time-of-flight-photoelectron emission microscopy on plasmonic structures using attosecond extreme ultraviolet pulses. Appl. Phys. Lett. 100, 051904 (2012).
Damascelli, A., Hussain, Z. & Shen, Z.-X. Angle-resolved photoemission studies of the cuprate superconductors. Rev. Mod. Phys. 75, 473â541 (2003).
Lindner, F. et al. High-order harmonic generation at a repetition rate of 100 kHz. Phys. Rev. A 68, 013814 (2003).
Chen, M.-C. et al. Spatially coherent, phase matched, high-order harmonic EUV beams at 50 kHz. Opt. Express 17, 17376â17383 (2009).
Heyl, C. M., Güdde, J., LâHuillier, A. & Höfer, U. High-order harmonic generation with μJ laser pulses at high repetition rates. J. Phys. B At. Mol. Opt. Phys. 45, 074020 (2012).
Cingöz, A. et al. Direct frequency comb spectroscopy in the extreme ultraviolet. Nature 482, 68â71 (2012).
Bernhardt, B. et al. Vacuum ultraviolet frequency combs generated by a femtosecond enhancement cavity in the visible. Opt. Lett. 37, 503â505 (2012).
Lee, J., Carlson, D. R. & Jones, R. J. Optimizing intracavity high harmonic generation for XUV fs frequency combs. Opt. Express 19, 23315â23326 (2011).
Hädrich, S. et al. Generation of μW level plateau harmonics at high repetition rate. Opt. Express 19, 19374â19383 (2011).
Cabasse, A., Machinet, G., Dubrouil, A., Cormier, E. & Constant, E. Optimization and phase matching of harmonic generation at high repetition rate. Opt. Lett. 37, 4618â4620 (2012).
Vernaleken, A. et al. Single-pass high-harmonic generation at 20.8 MHz repetition rate. Opt. Lett. 36, 3428â3430 (2011).
Hädrich, S. et al. High photon flux table-top coherent extreme-ultraviolet source. Nat. Photonics 8, 779â783 (2014).
Rothhardt, J. et al. Absorption-limited and phase-matched high harmonic generation in the tight focusing regime. N. J. Phys. 16, 033022 (2014).
Chini, M. et al. Coherent phase-matched VUV generation by field-controlled bound states. Nat. Photonics 8, 437â441 (2014).
Ditmire, T., Crane, J. K., Nguyen, H., DaSilva, L. B. & Perry, M. D. Energy-yield and conversion efficiency measurements of high-order harmonic radiation. Phys. Rev. A 51, 902â905 (1995).
Kim, I. et al. Highly efficient high-harmonic generation in an orthogonally polarized two-color laser field. Phys. Rev. Lett. 94, 243901 (2005).
Shiner, A. D. et al. Wavelength scaling of high harmonic generation efficiency. Phys. Rev. Lett. 103, 073902 (2009).
Falcão-Filho, E. L. et al. Scaling of high-order harmonic efficiencies with visible wavelength drivers: A route to efficient extreme ultraviolet sources. Appl. Phys. Lett. 97, 061107 (2010).
Salieres, P., LâHuillier, A. & Lewenstein, M. Coherence control of high-order harmonics. Phys. Rev. Lett. 74, 3776â3779 (1995).
Altucci, C. et al. Influence of atomic density in high-order harmonic generation. J. Opt. Soc. Am. B 13, 148â156 (1996).
Lai, C.-J. & Kärtner, F. X. The influence of plasma defocusing in high harmonic generation. Opt. Express 19, 22377â22387 (2011).
Takahashi, E. J., Hasegawa, H., Nabekawa, Y. & Midorikawa, K. High-throughput, high-damage-threshold broadband beam splitter for high-order harmonics in the extreme-ultraviolet region. Opt. Lett. 29, 507â509 (2004).
Kennedy, D. J. & Manson, S. T. Photoionization of the noble gases: cross sections and angular distributions. Phys. Rev. A 5, 227â247 (1972).
Lai, C.-J. et al. Wavelength scaling of high harmonic generation close to the multiphoton ionization regime. Phys. Rev. Lett. 111, 073901 (2013).
Falcão-Filho, E. L., Gkortsas, V. M., Gordon, A. & Kärtner, F. X. Analytic scaling analysis of high harmonic generation conversion efficiency. Opt. Express 17, 11217â11229 (2009).
Kazamias, S. et al. Pressure-induced phase matching in high-order harmonic generation. Phys. Rev. A 83, 063405 (2011).
Yudin, G. & Ivanov, M. Nonadiabatic tunnel ionization: looking inside a laser cycle. Phys. Rev. A 64, 013409 (2001).
Gkortsas, V.-M. et al. Interplay of multiphoton and tunneling ionization in short-wavelength-driven high-order harmonic generation. Phys. Rev. A 84, 013427 (2011).
Graf, J. et al. Vacuum space charge effect in laser-based solid-state photoemission spectroscopy. J. Appl. Phys. 107, 014912 (2010).
Dakovski, G. L., Li, Y., Durakiewicz, T. & Rodriguez, G. Tunable ultrafast extreme ultraviolet source for time- and angle-resolved photoemission spectroscopy. Rev. Sci. Instr. 81, 073108 (2010).
Frassetto, F. et al. Single-grating monochromator for extreme-ultraviolet ultrashort pulses. Opt. Express 19, 19169â19181 (2011).
Caracciolo, E. et al. 28-W, 217 fs solid-state Yb:CAlGdO4 regenerative amplifiers. Opt. Lett. 38, 4131â4133 (2013).
Gullikson, E. & Henke, B. CXRO X-ray interactions with matter http://henke.lbl.gov/optical_constants (2010).
Acknowledgements
We thank H. Mashiko and T. Sekikawa for interesting discussions, as well as P. Froemel, S. Stoll and L. Zeng for help with the experimental setup and amplifier beam characterization. This work was supported by the US Department of Energy, Office of Basic Energy Sciences (DOE BES), Division of Materials Sciences and Engineering under contract DE-AC02-05CH11231, carried out within the Ultrafast Materials Science program at Lawrence Berkeley National Laboratory. S.U. acknowledges a fellowship from the German Academic Exchange Service (DAAD).
Author information
Authors and Affiliations
Contributions
H.W. designed and performed the HHG experiments, with assistance from Y.X. and S.U. Moreover, H.W. and R.K. analysed the results, carried out simulations and wrote the manuscript. All authors contributed to the discussion of the experimental data and the manuscript.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Supplementary Information
Supplementary Figure 1, Supplementary Methods and Supplementary References. (PDF 275 kb)
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the articleâs Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Wang, H., Xu, Y., Ulonska, S. et al. Bright high-repetition-rate source of narrowband extreme-ultraviolet harmonics beyond 22âeV. Nat Commun 6, 7459 (2015). https://doi.org/10.1038/ncomms8459
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/ncomms8459
This article is cited by
-
Bright continuously tunable vacuum ultraviolet source for ultrafast spectroscopy
Communications Physics (2024)
-
A versatile high-average-power ultrafast infrared driver tailored for high-harmonic generation and vibrational spectroscopy
Scientific Reports (2023)
-
Angle-resolved photoemission spectroscopy
Nature Reviews Methods Primers (2022)
-
Ultra-short-pulse high-average-power megahertz-repetition-rate coherent extreme-ultraviolet light source
PhotoniX (2021)
-
Enhanced XUV harmonics generation from diatomic gases using two orthogonally polarized laser fields
Scientific Reports (2021)