Abstract
Low-intensity ultrasound is an emerging modality for neuromodulation. Yet, transcranial neuromodulation using low-frequency piezo-based transducers offers poor spatial confinement of excitation volume, often bigger than a few millimeters in diameter. In addition, the bulky size limits their implementation in a wearable setting and prevents integration with other experimental modalities. Here, we report spatially confined optoacoustic neural stimulation through a miniaturized Fiber-Optoacoustic Converter (FOC). The FOC has a diameter of 600 μm and generates omnidirectional ultrasound wave locally at the fiber tip through the optoacoustic effect. We show that the acoustic wave generated by FOC can directly activate individual cultured neurons and generate intracellular Ca2+ transients. The FOC activates neurons within a radius of 500 μm around the fiber tip, delivering superior spatial resolution over conventional piezo-based low-frequency transducers. Finally, we demonstrate direct and spatially confined neural stimulation of mouse brain and modulation of motor activity in vivo.
Similar content being viewed by others
Introduction
Ultrasound is an emerging neuromodulation technique that offers the potential of non-invasively modulating brain activities1,2. Early reports of neuromodulation using high-intensity ultrasound date back to the 1920s, likely through a tissue heating mechanism3,4. In the past decade, neural stimulation using low-intensity, low-frequency focused ultrasound has been demonstrated to directly evoke action potentials and modulate motor responses in rodents2,5, rabbits6, non-human primates7, and sensory/motor responses in humans8,9,10,11 through a non-thermal mechanism. Two recent papers by the Shapiro group12 and Lim group13 argued that these responses could be a consequence of indirect auditory stimulation through the cochlear pathway. On the other hand, Tyler, Baccus, Shoham, Pauly, and their coworkers reported direct activation of neurons in brain slices14, isolated retina15,16, and deaf mice17, where no auditory circuitry is involved. A major challenge facing ultrasound neural modulation, which contributes to the mentioned controversies, is that delivery of transcranial ultrasound would inevitably go through the skull, and eventually reach the cochlea through bone transduction. Moreover, the presence of the skull will reflect acoustic waves and compromise the ultrasound focus, resulting in a spatial resolution of a few millimeters, which is insufficient for region-specific brain stimulation in small rodents.
An alternative way to generate ultrasound wave is through the optoacoustic effect. In an optoacoustic process, pulsed light is illuminated on an absorber, causing transient heating and thermal expansion, and generating broadband acoustic waves at ultrasonic frequencies18. Recently, the optoacoustic effect has received increasing attention in the fields of imaging and translational medicine19,20. Using endogenous, as well as exogenous absorbers, optoacoustic tomography, and microscopy have found broad biomedical applications21,22. More specifically, optoacoustic tomography has allowed imaging of brain structures, as well as function in a non-invasive manner23,24,25,26. Beyond imaging, recent advances in developing optoacoustic materials have enabled highly efficient optoacoustic conversion27. Pulsed light excitation of these optoacoustic materials generates ultrasound waves at high amplitude, which allowed for all-optical ultrasound imaging28,29, tissue cavitation30,31, and precision surgical guidance of lumpectomy32.
Here, we report the use of acoustic waves generated by the optoacoustic process for direct and spatially confined neural stimulation both in culture and in vivo in a functional brain. The stimulation is based on a novel fiber-optoacoustic converter (FOC) that generates omnidirectional low-frequency ultrasound pulses emitting from a coated fiber tip. The miniaturized size of the FOC together with a rapid attenuation of optoacoustic intensity with distance provides superior spatial confinement of the generated ultrasound. By time-resolved calcium imaging, we demonstrate that the FOC can reliably produce neural activation within a 500âμm radius from the FOC tip in cultured neurons. By combining FOC with in vivo electrophysiology recordings, we achieved direct optoacoustic activation of mouse somatosensory cortex in the mouse brain, providing evidence that the observed activation is a consequence of direct neural stimulation without the involvement of the cochlear pathway. Finally, we demonstrate functional modulation of the motor cortex by showing that FOC can evoke motor responses with high-spatial precision.
Results
Fabrication and characterization of FOC
The FOC is composed of a passively Q-switched diode-pumped solid-state laser (PQSY, RPMC USA) centered at 1030ânm with a pulse width of 3âns and pulse energy of 100âμJ, a 200-μm core diameter, ~0.5âm long, 0.22âNA multimodal fiber, and a ball-shaped coated tip with a diameter of ~600âμm (Fig. 1a). Through the optoacoustic process, the pulsed laser energy is converted into acoustic waves generated at the FOC tip. The acoustic waves then excite neurons in the proximity to the tip. The FOC tip was coated with a 2-layer nano-composite (Fig. 1b). The first layer is a diffusion layer composed of a mixture of ZnO nanoparticles in epoxy (15% w/w). The ZnO nanoparticles have a 100-nm diameter, which is smaller than the wavelength of the incident light and enables Raleigh scattering of the light. Consequently, the incident light is randomly scattered in all directions, which produces a relatively uniform angular distribution of the laser pulse (Supplementary Fig. 2). The second layer is an absorption layer composed of a mixture of graphite powders in epoxy (30% w/w). With its high optical absorption and thermal conduction efficiency, the graphite completely absorbs the diffused laser and converts it into heat. The heat is then transferred to surrounding epoxy, creating expansion and compression of the epoxy, and generating acoustic waves that propagate in an omnidirectional manner. To characterize the generated acoustic wave from FOC, we applied the nanosecond laser at a pulse energy of 14.5âμJ, and measured the acoustic wave by an ultrasound transducer underwater. A representative acoustic wave generated by a single laser pulse is shown in Fig. 1c. The radiofrequency spectrum shows that the generated acoustic wave is in the ultrasound frequency ranging from 0.5 to 5âMHz, with multiple peaks between 1 and 5âMHz (Fig. 1d). The maximum acoustic pressure is measured to be 0.48âMPa using a needle hydrophone. To examine the angular distribution of the acoustic wave, we measured the pressures at various angles. The distribution map shows that the intensity is the strongest in the forward direction, while the back-propagating ultrasound is about 50% of the forward intensity (Fig. 1e). We note that fiber-based optoacoustic generation with a single layer of absorber has been reported33,34. A novel component of our FOC is the double-layer structure, where the diffuse layer not only results in an omnidirectional acoustic wave, but also significantly lowers the acoustic wave frequency (Supplementary Fig. 1). Low-frequency ultrasound was shown to be more efficient for neural modulation35.
FOC stimulation in vitro with high-spatial precision
To investigate whether the FOC can directly modulate neuronal activity, we examined the response of cultured neurons to FOC stimulation. We treated rat cortical neurons (days in vitro 18 to 22) with a calcium indicator, Oregon Green⢠488 BAPTA-1 dextran (OGD-1), and performed calcium imaging (Fig. 2a) using an inverted wide-field fluorescence microscope (Supplementary Fig. 3). The FOC was placed ~100âμm above the focal plane, in the center of the field of view. The acoustic wave was produced with laser pulses at a repetition rate of 3.6âkHz over a period of 200âms, which corresponds to ~720 pulses (Supplementary Fig. S4). Calcium transients were observed for all neurons in the field of view (max ÎF/Fâ=â9.5â±â2.9%, nâ=â36 cells from three cultures, data in meanâ±âSD) (Fig. 2b). Addition of 15âμM intracellular calcium chelator BAPTA-AM significantly reduced the calcium signal (max ÎF/Fâ=â2.6â±â0.5%, nâ=â12,) (Supplementary Fig. 5) compared to neurons without BAPTA-AM (pâ=â1.17âÃâ10â5, two-sample t-test). The response latency was found to be <50âms, since the responses were observed at the first frame post stimulation onset across experiments with a camera acquisition rate at 20âHz. To identify the threshold for FOC-induced neural activation, we varied the stimulation duration to 100, 50, and 20âms. The FOC successfully produced neural activation with 100 and 50âms stimulation, but not with 20âms stimulation (Fig. 2c). We next asked whether the FOC can produce neural activation reliably and repeatedly. Eight bursts of laser pulses, each with 200âms burst duration and 2-s inter-burst interval, were delivered to the FOC. Stable calcium transients in response to each laser pulse train were observed (max ÎF/Fâ=â12â±â0.6%, eight pulses) (Fig. 2d) (Supplementary Movie 1). No obvious morphological changes were detected in neurons stimulated multiple times over a 2-h duration (Fig. 2e).
To verify that the FOC-induced calcium transients are specific to neurons, we loaded OGD-1 to a prostate cancer cell line (PC3). By 200-ms FOC stimulation, we observed a calcium signal (max ÎF/Fâ=â0.7â±â2.7%, nâ=â52) significantly smaller than that in neurons (pâ=â1.98âÃâ10â7, two-sample t-test) (Supplementary Fig. 6). Next, we obtained a rat glial culture loaded with OGD-1 and delivered 200-ms FOC stimulation to morphologically identified astrocytes, and observed responses (max ÎF/Fâ=â1.2â±â0.6%, nâ=â82) significantly smaller than the calcium transients produced by FOC stimulated neurons (pâ=â1.16âÃâ10â6, two-sample t-test) (Supplementary Fig. 7). The glial culture was immuno-stained after experiments and was confirmed as GFAP positive. These data suggest that the FOC reliably and selectively activates neuronal cells in vitro.
A key advantage of FOC over traditional ultrasound transducers is that the FOC emits pulsed ultrasound waves locally at the coated fiber tip, which allows localized stimulation. If homogeneous omnidirectional propagation is assumed, as the wavefront propagates and expands, the acoustic intensity I at distance d can be described as \(I_d = I_0 \cdot \left( {\frac{r}{{r + d}}} \right)^2\), where I0 is the intensity at the FOC surface, and r is the radius of the FOC tip. Since the acoustic pressure p is \(p = \sqrt {I \cdot Z}\), where Z is the acoustic impedance. This gives the acoustic pressure p at distance d as \(p_d = \frac{r}{{r + d}}\sqrt {I_0 \cdot Z}\). Thus, the acoustic intensity is expected to attenuate quickly when propagating in the medium. To experimentally characterize the attenuation of acoustic wave with distance, we used a transducer array to perform wavefront reconstruction. Wavefronts at 6 different time delays with 0.4âμs interval were stitched together in Fig. 3a. We fitted the curve with the equation described above. With a FOC tip of 600âμm in diameter, the acoustic intensity is attenuated by 61% at 1.0âmm away from the tip underwater (Fig. 3b). This result demonstrates submillimeter spatial precision. Since the brain tissue has a much higher ultrasound attenuation coefficient (0.6âdB/cm MHz) than water (0.0022âdB/cm MHz)36, we expect the FOC to produce even more localized acoustic wave inside the brain. To demonstrate that FOC-induced neural activation is spatially confined, we placed the FOC at the edge of the imaging field of view and delivered a laser pulse train of 200âms duration (Fig. 3c). It was observed that neurons within 500âμm distance from the FOC showed reliable calcium response, and that the amplitude of the response is highly dependent on the relative distance from the FOC (Fig. 3d). When we sorted the neurons by their distance from the FOC, we found that neurons that are within 500âμm to the FOC showed strong responses (max ÎF/Fâ=â9.4â±â3.4%, nâ=â10), while neurons that are 500âμm to 1.0 millimeter away showed significantly smaller responses (max ÎF/Fâ=â1.5â±â1.0%, nâ=â13, pâ=â1.9âÃâ10â4, two-sample t-test) (Fig. 3e). These data demonstrate that the effect of FOC is highly localized within a 500âμm radius, which provides one order of magnitude better spatial resolution comparing to the widely used piezo transducers having a several-millimeter focus area.
To eliminate the possibility that the activation is due to laser illumination, we measured the leaked light energy from the FOC tip with a photodiode and found only 0.11% of the laser leaked out of the FOC. Additionally, we used an uncoated optical fiber and delivered the same laser pulses with 10% of the laser intensity at 3.6âkHz repetition rate and 200âms duration directly to the neuron. No calcium transients were observed (Supplementary Fig. 8a). To examine the possibility of photothermal neural activation, we measured the heat profile of the FOC tip using a miniaturized ultrafast thermal probe. The temperature increase on the FOC surface was found to be 1.6, 0.9, 0.5â°C for 200, 100, 50âms laser stimulations, respectively (Supplementary Fig. 8b). Such temperature increase is well below the previously reported threshold for thermal induced neural activation (ÎTâ>â5â°C)37. Therefore, the neural activation effect is most likely contributed by the generated acoustic wave.
FOC induces direct activation in mouse brain
Since we demonstrated that the FOC can reliably stimulate neurons with high-spatial precision in vitro, we next moved on to investigate whether FOC can successfully induce neural activation in vivo in the mouse brain, with similar spatial precision. A mouse was anesthetized with 1% isoflurane, and a cranial window was made above the primary somatosensory cortex (S1) and primary auditory cortex (A1) based on stereotaxic coordinates with the dura intact (Fig. 4a). First, we investigated whether FOC can produce activation of the local cortical area. The FOC was brought close to contact the brain surface and immersed in saline. Laser pulse trains with 200âms and 50âms duration were delivered to the FOC, and neural activities were recorded with a tungsten electrode. We observed robust local-field potential (LFP) response to the FOC stimulation for both stimulation durations, with response latency of 15.87â±â1.34âms (nâ=â9, from three mice) (Fig. 4b), which is indicative of direct neural activation. When the FOC was lifted up by 100âμm without contacting the brain or immersing saline, the FOC failed to induce any neural activation (Fig. 4c). This result indicates that the neural activation is induced by acoustic waves that have minimal propagation in the air. Next, we delivered FOC stimulation to the ipsilateral A1, which is ~2âmm away from the S1 recording site. No neural response was detected, which indicates that the FOC stimulation was spatially confined to S1 (Fig. 4c). To further quantify the spatial precision in vivo, we recorded the LFP responses as the FOC moves away from the recording electrode. The LFP amplitude drops from 159.8â±â13.2âμV to 10.5â±â5.1âμV at 400âμm away (nâ=â3) (Fig. 4d), demonstrating superior spatial confinement of FOC stimulation in vivo.
Since ultrasound stimulation by auditory pathway has been reported12,13, we examined whether the auditory pathway is involved in the FOC stimulation. One cranial window was made above the S1 region, and another on the contralateral A1 region. The FOC stimulation was delivered to the S1, and the recording electrode was placed in the ipsilateral S1 or contralateral A1 (Fig. 4e). If the auditory pathway is involved, we would expect to observe strong responses in the contralateral A1 with ~50âms delay13. However, a FOC stimulation of 200âms duration on the S1 evoked robust LFP response on ipsilateral S1, but failed to evoke any response in the contralateral A1 (Fig. 4f). Finally, to rule out the possibility of laser or ultrasound-induced electrical artifact of the electrode, we record voltage change on the FOC surface in saline and found that laser pulses of 200âms duration produced no voltage change on the FOC tip (Supplementary Fig. 9). Collectively, these data suggest that the FOC produces direct neural stimulation in vivo with high-spatial and temporal precision, without the involvement of the auditory pathway.
Modulation of motor activity by FOC stimulation
Since ultrasound is known to modulate motor activities in vivo5,6,17, we next turned to the motor cortex to investigate the functional outcome of the FOC mediated neural modulation. The FOC was placed on the motor cortex based on stereotaxic coordinates and an electromyography (EMG) electrode was inserted subcutaneously and parallel to the triceps brachii muscle (Fig. 5a). A laser pulse train over a period of 200âms was delivered to the FOC, while the muscle potential was recorded simultaneously. The FOC stimulation in the motor cortex evoked strong EMG responses (396.7â±â135.8âμV) recorded from the forelimb triceps brachii muscle, with a mean latency of 49.7â±â12.8âms (nâ=â9, from three mice). As a control, no responses were recorded without FOC stimulation (Supplementary Fig. 10). To demonstrate the spatial precision of FOC stimulation, we scanned the FOC stimulation site on the motor cortex, to map the motor representation for forelimb triceps brachii muscle. Since the FOC stimulation was confined within a 500âμm radius, 1âmm spacing was chosen between each stimulation location. We scanned a 3âÃâ3âmm2 area, which covers the majority of motor cortex, and obtained the maximum peak to peak amplitude of the EMG response to the stimulation. A heat map of normalized EMG amplitude is shown in Fig. 5b, each point on the map is an average of three trials on the same stimulation location. Inserts show three representative EMG traces of a strong, medium and weak muscle responses recorded at three different locations, respectively. The maximum EMG responses were obtained at AP (anterior/posterior) 0, ML (medial/lateral) 1, and AP 1, ML 2, which is in agreement with previous motor mapping studies using intracortical micro current stimulation (IMCS), and photoactivation of ChR2 expressing mice38. In comparison, we find that FOC stimulation delivered to the S1 cortex also evoked EMG responses on the forelimb muscle, but with a much longer latency (571.2â±â235.9âms, nâ=â6, from two mice pâ=â1.5âÃâ10â4, two-sample t-test) (Fig. 5c, d). The latency was in the same range as studies using IMCS and single cell stimulation in the S139. After stimulation, the brain was extracted for histology. No tissue damage was observed after repeated stimulation (Supplementary Fig. 11). Collectively, these results show that the FOC can differentially modulate the mouse motor cortex and somatosensory cortex at submillimeter spatial precision, which is not currently possible with transcranial ultrasound neural modulation.
Discussion
We demonstrated a miniaturized FOC that can induce neural activation with high-spatial precision both in vitro and in vivo. The FOC has a ball-shaped coated tip with a diameter of ~600âμm and allows omnidirectional generation of acoustic waves at 1 to 5âMHz and with the acoustic intensity of 0.48âMPa at the fiber surface. Strong spatial confinement of optoacoustic intensity is achieved by the nano-composite diffusion layer and the ball-shaped geometry. The neural response is shown to be neither thermal nor laser-induced. The high-spatial precision of FOC stimulation was demonstrated by mapping of the representation of the forelimb triceps brachii muscle. With transcranial ultrasound modulation, such mapping was reported to be difficult, if not impossible, in mice due to lack of spatial resolution5.
An important observation is that the acoustic wave generated by the FOC directly activates targeted cortical areas in vivo, instead of indirect activation through the auditory pathway. This finding is supported by multiple pieces of evidence. First, the FOC is able to stimulate cortical neurons in culture, where no auditory circuits are involved; second, the FOC stimulated targeted cortical area only with <20âms delay, which is indicative of direct stimulation; third, the stimulation was delivered to the cortex directly, avoiding any possible bone transduction to the cochlear; finally, the FOC stimulation did not induce neural response on the auditory cortex contralateral to the stimulation site, thus eliminating the involvement of the auditory pathway. Our results are consistent with previous studies where focused ultrasound can directly stimulate hippocampal slices, isolated retina in vitro, and activate mouse M1 in vivo with <50âms delay5,14,15.
Although the FOC and piezo-based transducer both can generate acoustic waves in the ultrasonic frequency, significant differences exist between these two devices. First, the FOC with a diameter of around 600âμm is significantly smaller than most commercially available ultrasound transducers. The FOC size can be further reduced by using optical fiber with a smaller diameter and reducing the coating layers. The much smaller size allows the FOC to be implantable and can be used for behavior study in live free-running animals, which is impossible with traditional ultrasound transducers. Second, the FOC generates 1-μs pulsed acoustic waves repeated at 3.6âkHz. The duty cycle of this acoustic wave is about 0.36%. This low-duty cycle avoids ultrasound heating of biological tissues, making the FOC device particularly suitable for in vivo applications. However, these two modalities do share some similarities. For most transcranial ultrasound neural modulation applications, the peak pressure ranges from 0.1 to 2âMPa1,2. The peak acoustic pressure generated by the FOC was measured to be 0.48âMPa, which falls into the range of ultrasound intensity used for neural modulation reported in the literature. Furthermore, a wide range of frequencies has been reported to achieve neural modulation (200âkHz to 32âMHz)1,2. Generally, the lower frequency is used for transcranial stimulation, and a higher frequency is used to achieve high-spatial confinement. The current FOC generates broadband ultrasound wave with multiple peaks ranging from 1 to 5âMHz, where the spatial precision is achieved because the acoustic wave intensity from the FOC tip attenuates rapidly with distance.
The mechanism of optoacoustic neural stimulation is yet to be investigated1. Ultrasound neural stimulation and optoacoustic neural stimulation are similar in the way that both methods create a mechanical disturbance on the neuronal membrane and are likely to share the same mechanism. Two mechanisms are proposed for ultrasound neural stimulation: ultrasound-induced intramembrane cavitation40,41,42 and activation of mechanosensitive channels43,44. Future studies using specific mechanosensitive channels blockers are needed to identify the relative contributions of these two mechanisms.
Finally, we note that the FOC tip is very versatile and can be easily customized for more advanced applications. The propagation of the generated acoustic wave depends largely on the FOC tip geometry. While the ball-shaped FOC tip allows omnidirectional acoustic wave propagation with a rapid attenuation of optoacoustic intensity with distance, other geometries can be adopted to generate forward, focused and even patterned, complex acoustic field45,46,47. These advanced geometries can be used for neural modulation at even higher spatial resolution. Additionally, the fiber-based design allows the FOC to be implanted for longitudinal study in live, behaving animals. Given the increasing popularity of ultrasound neuromodulation, the compactness, cost-effectiveness, and versatility of FOC open a lot of opportunities to utilize the optoacoustic effect to achieve high-precision neural stimulation. Without the need for genetic modification, we expect that FOC will eventually be used for neural modulation on human subjects, similar to electrode-based deep brain stimulation but in a metal-free manner.
Methods
Fabrication of FOC
The FOC was fabricated by first coating the fiber with a light diffusion layer, followed by coating of an absorption layer. ZnO nanoparticles (Sigma-Aldrich) were mixed with epoxy at a concentration of 15% by weight, and a polished multimodal optic fiber with 200âµm core diameter (Thorlabs) was dipped 150âµm into the mixture and quickly pulled out using a one-dimension translational stage under stereoscope. After 30âmin curing at room temperature, the diffusion layer (~100âµm) was coated on the fiber tip. The absorption layer was fabricated by dipping of the diffusion layer coated fiber into a graphite powder and epoxy mixture (30% by weight), quickly pulled put and cure in room temperature. This process was repeated to ensure the absorption layer has enough thickness to absorb all the photons, which leads to a final absorption layer thickness of ~200âµm.
Acoustic wave characterization
The intensity of FOC-generated acoustic wave was measured with a needle hydrophone with a 0.04âmm sensor size (Precision Acoustics). For mapping of the acoustic wavefront, an EKSPLA OPO Laser with pulse width 5âns, repetition rate 10âHz was coupled into the FOC fiber as excitation laser. Photoacoustic signals were acquired in a water tank by a low-frequency transducer array (L7-4, PHILIPS/ATL) and processed by an ultrasound imaging system (Vantage128, Verasonics Inc.).
Primary neuronal and glial cultures
Primary cortical neuron cultures were derived from Sprague-Dawley rats. Briefly, cortices were dissected out from embryonic day 18 (E18) rats of either sex and then digested with papain (0.5âmg/mL in Earleâs balanced salt solution) (Thermofisher scientific) and plated on poly-d-lysine coated coverslips. For primary neuron cultures, cells were first plated in Dulbeccoâs Modified Eagle Medium (Thermofisher scientific) containing 10% fetal bovine serum (Thermofisher scientific) and 1% GlutaMAXtm (Thermofisher scientific), which was then replaced 24âh later by a feeding medium (Neurobasal medium supplemented with 2% B-27 (Thermofisher scientific) and 1% GlutaMAXtm (Thermofisher Scientific). Thereafter, the medium was replaced every 3 to 4 days until use. For primary glial cultures, cells were cultured in Dulbeccoâs Modified Eagle Medium (Thermofisher scientific) containing 10% fetal bovine serum (Thermofisher scientific) and medium was replaced every 3 to 4 days.
Calcium imaging
Calcium imaging was performed on a lab-built wide-field fluorescence microscope. The microscope was based on an Olympus IX71 microscope frame, with a 20x air objective (UPLSAPO20X, 0.75âNA, Olympus), illuminated by a 470ânm LED (M470L2, Thorlabs), an emission filter (FBH520-40, Thorlabs), an excitation filter (MF469-35, Thorlabs) and a dichroic mirror (DMLP505R, Thorlabs). Image sequences were acquired with a scientific CMOS camera (Zyla 5.5, Andor) at 20 frames per second. Oregon Green⢠488 BAPTA-1 dextran (OGD-1) (Invitrogen) was dissolved in 20% Pluronic F-127 in dimethyl sulfoxide (DMSO) at a concentration of 1âmM as stock solution. Before imaging, cells were incubated with 2âµM OGD-1 for 30âmin, followed by incubation with normal medium for 30âmin. During imaging, cells were placed in extracellular solution for cortical neurons containing 150âmM NaCl, 4âmM KCl, 10âmM HEPES, 10âmM glucose, 2âmM CaCl2 (pH 7.4). For application of BAPTA-AM, BAPTA-AM (Sigma-Aldrich) powder was dissolved in DMSO at concentration of 15âmM for stock solution, and during experiment, the stock solution was added to the extracellular solution to reach 15âμM final concentration before Calcium imaging.
Animal surgery
All experimental procedures have complied with all relevant guidelines and ethical regulations for animal testing and research established and approved by the Institutional animal care and use committee of Boston University. Adult (age 14â16 weeks) C57BL/6J mice were used. Mice were initially anesthetized using 5% isoflurane in oxygen and then placed on a standard stereotaxic frame, maintained with 1.5 to 2 % isoflurane. Toe pinch was used to determine the level of anesthesia throughout the experiments and body temperature was maintained with a heating pad. The hair and skin on the dorsal surface targeted brain regions were trimmed. Craniotomies were made on primary somatosensory (S1) (AP â1.34 ML 2.25), primary motor (M1) (AP â0.62 ML 1.5), and primary auditory cortex (A1) (AP â2.46 ML 4.25) based on stereotaxic coordinates using a dental drill and artificial cortical spinal fluid was administrated to immerse the brain. After stimulation and recordings, the mice were perfused with saline and 10% Formalin, and the brain was removed, paraffin embedded, sectioned, and H&E stained for histology.
Local-field potential (LFP) recording
LFP was performed using tungsten microelectrodes (0.5 to 1âMΩ; Microprobes). Tungsten microelectrodes were driven to recording sites through cranial windows based on stereotactic coordinates. The electrodes were positioned with a micromanipulator (Siskiyou). Extracellular recordings were acquired using a Multi Clamp 700B amplifier (Molecular Devices), filtered at 0.1 to 100âHz, and digitized with an Axon DigiData 1550 digitizer (Molecular Devices). For calculation of response latency, the pre-stimulation period in each recording was used to obtain baseline mean and SD. The threshold was determined by meanâ±â2âÃâSD. The latency was determined when the voltage crosses the threshold for the first time.
Motor mapping and EMG recording
The FOC was fix to a digital mouse stereotaxic instrument (Stoelting Co.). The bregma was calibrated to be coordinate (0,0), and the FOC was scanned through the mouse motor cortex with 1âmm interval laterally and posteriorly to the bregma. EMG was performed using needle electrode inserted subcutaneously and parallel to the forelimb triceps brachii muscle. Reference electrode was inserted in the footpad. A ground electrode was inserted subcutaneously on the trunk and ipsilateral to the stimulation site. EMG signals were acquired using a Multi Clamp 700B amplifier (Molecular Devices), filtered at 1 to 5000âHz, and digitized with an Axon DigiData 1550 digitizer (Molecular Devices).
Data analysis
Calcium images were analyzed using ImageJ. The fluorescence intensity was measured by selecting the soma. Acoustic waveforms, calcium traces, temperature traces, and electrophysiological traces were analyzed using Origin 2019. All statistical analysis was done using two-sample t-test. Data shown are meanâ±âSD.
Reporting summary
Further information on research design is available in the Nature Research Reporting Summary linked to this article.
Data availability
We declare that the main data supporting the findings of this study are available within the article and its Supplementary Information files. Source data are available in the Source Data file. Extra data are available from the corresponding author upon request.
References
Tyler, W. J., Lani, S. W. & Hwang, G. M. Ultrasonic modulation of neural circuit activity. Curr. Opin. Neurol. 50, 222â231 (2018).
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M. & Tyler, W. J. Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound. Nat. Protoc. 6, 1453â1470 (2011).
Harvey, E. N. The effect of high frequency sound waves on heart muscle and other irritable tissues. Am. J. Physiol. 91, 284â290 (1929).
Fry, F., Ades, H. & Fry, W. Production of reversible changes in the central nervous system by ultrasound. Science 127, 83â84 (1958).
Tufail, Y. et al. Transcranial pulsed ultrasound stimulates intact brain circuits. Neuron 66, 681â694 (2010).
Yoo, S. -S. et al. Focused ultrasound modulates region-specific brain activity. NeuroImage 56, 1267â1275 (2011).
Deffieux, T. et al. Low-intensity focused ultrasound modulates monkey visuomotor behavior. Curr. Biol. 23, 2430â2433 (2013).
Legon, W. et al. Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans. Nat. Neurosci. 17, 322â329 (2014).
Legon, W., Bansal, P., Tyshynsky, R., Ai, L. & Mueller, J. K. Transcranial focused ultrasound neuromodulation of the human primary motor cortex. Sci. Rep. 8, 10007 (2018).
Legon, W., Rowlands, A., Opitz, A., Sato, T. F. & Tyler, W. J. Pulsed ultrasound differentially stimulates somatosensory circuits in humans as indicated by eeg and fmri. PLoS ONE 7, e51177 (2012).
Mueller, J., Legon, W., Opitz, A., Sato, T. F. & Tyler, W. J. Transcranial focused ultrasound modulates intrinsic and evoked eeg dynamics. Brain Stimul. 7, 900â908 (2014).
Sato, T., Shapiro, M. G. & Tsao, D. Y. Ultrasonic neuromodulation causes widespread cortical activation via an indirect auditory mechanism. Neuron 98, 1031â1041.e1035 (2018).
Guo, H. et al. Ultrasound produces extensive brain activation via a cochlear pathway. Neuron 98, 1020â1030 (2018).
Tyler, W. J. et al. Remote excitation of neuronal circuits using low-intensity, low-frequency ultrasound. PLoS ONE 3, e3511 (2008).
Menz, M. D., Oralkan, O., Khuri-Yakub, P. T. & Baccus, S. A. Precise neural stimulation in the retina using focused ultrasound. J. Neurosci. 33, 4550â4560 (2013).
Naor, O., Hertzberg, Y., Zemel, E., Kimmel, E. & Shoham, S. Towards multifocal ultrasonic neural stimulation II: design considerations for an acoustic retinal prosthesis. J. Neural Eng. 9, 026006 (2012).
Mohammadjavadi, M. et al. Elimination of peripheral auditory pathway activation does not affect motor responses from ultrasound neuromodulation. Brain Stimul. 12, 901â910 (2019).
Wang, L. V. Photoacoustic Imaging and Spectroscopy. (CRC press, 2009).
Wang, L. V. & Hu, S. Photoacoustic tomography: in vivo imaging from organelles to organs. Science 335, 1458â1462 (2012).
Taruttis, A. & Ntziachristos, V. Advances in real-time multispectral optoacoustic imaging and its applications. Nat. Photonics 9, 219 (2015).
Weber, J., Beard, P. C. & Bohndiek, S. E. Contrast agents for molecular photoacoustic imaging. Nat. Methods 13, 639 (2016).
Wang, L. V. & Yao, J. A practical guide to photoacoustic tomography in the life sciences. Nat. Methods 13, 627 (2016).
Gottschalk, S. et al. Rapid volumetric optoacoustic imaging of neural dynamics across the mouse brain. Nat. Biomed. Eng. 3, 392 (2019).
Olefir, I. et al. Spatial and spectral mapping and decomposition of neural dynamics and organization of the mouse brain with multispectral optoacoustic tomography. Cell Rep. 26, 2833â2846. e2833 (2019).
Ovsepian, S. V., Olefir, I., Westmeyer, G., Razansky, D. & Ntziachristos, V. Pushing the boundaries of neuroimaging with optoacoustics. Neuron 96, 966â988 (2017).
Ovsepian, S. V., Olefir, I. & Ntziachristos, V. Advances in optoacoustic neurotomography of animal models. Trend. Biotechnol. 37, 1315â1326 (2019).
Lee, T., Baac, H. W., Li, Q. & Guo, L. J. Efficient photoacoustic conversion in optical nanomaterials and composites. Adv. Opt. Mater. 0, 1800491 (2018).
Buma, T., Spisar, M. & Oâdonnell, M. High-frequency ultrasound array element using thermoelastic expansion in an elastomeric film. Appl. Phys. Lett. 79, 548â550 (2001).
Zhang, E., Laufer, J. & Beard, P. Backward-mode multiwavelength photoacoustic scanner using a planar fabry-perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues. Appl. Opt. 47, 561â577 (2008).
Baac, H. W. et al. Carbon-nanotube optoacoustic lens for focused ultrasound generation and high-precision targeted therapy. Sci. Rep. 2, 989 (2012).
Lee, T., Luo, W., Li, Q., Demirci, H. & Guo, L. J. Laser-induced focused ultrasound for cavitation treatment: toward high-precision invisible sonic scalpel. Small 13, 1701555 (2017).
Lan, L. et al. A fiber optoacoustic guide with augmented reality for precision breast-conserving surgery. Light Sci. Appl. 7, 2 (2018).
Zou, X., Wu, N., Tian, Y. & Wang, X. Broadband miniature fiber optic ultrasound generator. Opt. Express 22, 18119â18127 (2014).
Colchester, R. J. et al. Broadband miniature optical ultrasound probe for high resolution vascular tissue imaging. Biomed. Opt. Express 6, 1502â1511 (2015).
King, R. L., Brown, J. R., Newsome, W. T. & Pauly, K. B. Effective parameters for ultrasound-induced in vivo neurostimulation. Ultrasound Med. Biol. 39, 312â331 (2013).
Culjat, M. O., Goldenberg, D., Tewari, P. & Singh, R. S. A review of tissue substitutes for ultrasound imaging. Ultrasound Med. Biol. 36, 861â873 (2010).
Shapiro, M. G., Homma, K., Villarreal, S., Richter, C. -P. & Bezanilla, F. Infrared light excites cells by changing their electrical capacitance. Nat. Commun. 3, 736 (2012).
Ayling, O. G., Harrison, T. C., Boyd, J. D., Goroshkov, A. & Murphy, T. H. Automated light-based mapping of motor cortex by photoactivation of channelrhodopsin-2 transgenic mice. Nat. Methods 6, 219 (2009).
Houweling, A. R. & Brecht, M. Behavioural report of single neuron stimulation in somatosensory cortex. Nature 451, 65 (2008).
Saffari, N., Wright, C. J. & Rothwell, J. Ultrasound neuro-stimulation effects of peripheral axons in-vitro. J. Acoust. Soc. Am. 142, 2668â2668 (2017).
Plaksin, M., Kimmel, E. & Shoham, S. Cell-type-selective effects of intramembrane cavitation as a unifying theoretical framework for ultrasonic neuromodulation. eNeuro 3, 0136â0115 (2016).
Krasovitski, B., Frenkel, V., Shoham, S. & Kimmel, E. Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects. Proc. Natl Acad. Sci. USA 108, 3258â3263 (2011).
Kubanek, J. et al. Ultrasound modulates ion channel currents. Sci. Rep. 6, 24170 (2016).
Ibsen, S., Tong, A., Schutt, C., Esener, S. & Chalasani, S. H. Sonogenetics is a non-invasive approach to activating neurons in caenorhabditis elegans. Nat. Commun. 6, 8264 (2015).
Brown, M. D., Jaros, J., Cox, B. T. & Treeby, B. E. Control of broadband optically generated ultrasound pulses using binary amplitude holograms. J. Acoust. Soc. Am. 139, 1637â1647 (2016).
Brown, M., Nikitichev, D., Treeby, B. & Cox, B. Generating arbitrary ultrasound fields with tailored optoacoustic surface profiles. Appl. Phys. Lett. 110, 094102 (2017).
Mohammadzadeh, M. et al. Photoacoustic shock wave emission and cavitation from structured optical fiber tips. Appl. Phys. Lett. 108, 024101 (2016).
Acknowledgements
We thank Y. Bai for help with building the fluorescence microscope, S. Cha with the testing on in vivo experiments, and M. OâConnor, M. Hastings for help with neuronal cultures. We also thank the Boston University Experimental Pathology Laboratory Service Core for help with histology experiments. This work was supported by R01 NS109794 to J.C. to X.H.
Author information
Authors and Affiliations
Contributions
J.C. conceived the concept of using the optoacoustic effect for neurostimulation; Y.J. and L.L. designed and fabricated the FOC device; Y.J., H.J.L., and L.L. designed and performed the experiments; Y.J., H.J.L., H.T., C.Y., X.H., and J.C. discussed and analyzed the data; H.M. provided neuron cultures; Y.J. and J.C. wrote the manuscript. All authors discussed and edited the manuscript; X.H. and J.C. supervised the project.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Peer review information Nature Communications thanks Saak Ovsepian and the other, anonymous, reviewer(s) for their contribution to the peer review of this work. Peer reviewer reports are available.
Publisherâs note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Source data
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the articleâs Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the articleâs Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Jiang, Y., Lee, H.J., Lan, L. et al. Optoacoustic brain stimulation at submillimeter spatial precision. Nat Commun 11, 881 (2020). https://doi.org/10.1038/s41467-020-14706-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-020-14706-1
This article is cited by
-
Janus microparticles-based targeted and spatially-controlled piezoelectric neural stimulation via low-intensity focused ultrasound
Nature Communications (2024)
-
Neural stimulation and modulation with sub-cellular precision by optomechanical bio-dart
Light: Science & Applications (2024)
-
A Self-Healing Optoacoustic Patch with High Damage Threshold and Conversion Efficiency for Biomedical Applications
Nano-Micro Letters (2024)
-
Optically-generated focused ultrasound for noninvasive brain stimulation with ultrahigh precision
Light: Science & Applications (2022)
-
Lead halide perovskite for efficient optoacoustic conversion and application toward high-resolution ultrasound imaging
Nature Communications (2021)