Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Amwnfh Serie

Descargar como pdf o txt
Descargar como pdf o txt
Está en la página 1de 76

MULTI INVERTER SERIE AMW-NFH

Manual de usuario
e instalación

R32

CL80200 ~ CL80209
ES ................................................................................................................................. 3

EN .............................................................................................................................. 38

2
ES Manual de Instalación y Usuario
 
ÍNDICE
MEDIDAS DE SEGURIDAD.......................................................................................... 4
MANUAL DE INSTALACIÓN ........................................................................................ 8
Instalación unidad interior ............................................................................................. 8
Instalación de unidad exterior ....................................................................................... 9
Instalación tuberías de refrigerante ..............................................................................11
Instalación eléctrica ......................................................................................................13
Instalación de drenaje ..................................................................................................14
Puesta en marcha y pruebas de funcionamiento .........................................................14
MANUAL DE USUARIO .............................................................................................. 15
Descripción y funcionamiento .......................................................................................15
Cuidado y mantenimiento .............................................................................................19
Solución de problemas ................................................................................................ 21
Eliminación .................................................................................................................. 22
CONTROL REMOTO ................................................................................................... 23
INFORMACIÓN DE SERVICIO.................................................................................... 32

Precaución: Riesgo de fuego


IMPORTANTE:
Este equipo de aire acondicionado es para uso exclusivamente doméstico o comercial, nunca debe insta-
-larse en ambientes húmedos como baños, lavaderos o piscinas.
Este equipo debe ser instalado por un profesional debidamente cualificado según los RD 795/2010,
RD 1027/2007, RD 238/2013.
ADVERTENCIA:
El mantenimiento solo se puede realizar como lo recomienda el fabricante.
El mantenimiento y la reparación que necesiten la asistencia de otra persona cualificada se deben realizar
bajo la supervisión de una persona competente y formada para el uso de refrigerantes inflamables.
La alimentación debe ser MONOFÁSICA (una fase (L) y una neutro (N) con conexión a tierra (GND)) o
TRIFÁSICA (tres fases (L1, L2, L3) y un neutro (N) con conexión a tierra (GND)) y con interruptor manual.
El no cumplimiento de estas especificaciones infringe las de condiciones de garantía ofrecidas por el
fabricante.

NOTA:
Teniendo en cuenta la política de la compañía de continua mejora del producto, tanto la estética como las
dimensiones, las fichas técnicas y los accesorios de este equipo pueden cambiar sin previo aviso.
ATENCIÓN:
Lea este manual cuidadosamente antes de instalar y usar su nuevo aire acondicionado. Asegúrese de
guardar este manual como referencia futura.

3
MEDIDAS DE SEGURIDAD
Gracias por adquirir este aire acondicionado. Este manual le proporcionará información sobre cómo operar, mantener y
solucionar problemas de su aire acondicionado. Seguir las instrucciones asegurará el funcionamiento adecuado y la
vida útil prolongada de su unidad.
Lea las precauciones de seguridad antes de realizar la instalación
Una instalación incorrecta debido al incumplimiento de las instrucciones puede causar daños graves o lesiones.
La gravedad del daño potencial o las lesiones se clasifican como ADVERTENCIA o PRECAUCIÓN.

El incumplimiento de estas advertencias puede provocar la muerte. La unidad se debe instalar


teniendo en cuenta las regulaciones nacionales vigentes.

ADVERTENCIA

Si no se tienen en cuenta las precauciones se pueden provocar lesiones o daños al equipo.

¡PRECAUCIÓN!

Este símbolo indica que nunca debe realizar la acción indicada.

ADVERTENCIA
1. Pida a un técnico autorizado que le instale el aire acondicionado. Una mala instalación puede causar
fugas de agua, descargas eléctricas o incendios.
2. La garantía quedará anulada si la unidad no es instalada por profesionales.
3. Llame a su proveedor y pídale instrucciones de cómo evitar descargas eléctricas, incendios o lesiones.
4. NO permita que se moje ni la unidad interior ni el control remoto. Puede ocasionar riesgos de descargas
eléctricas o incendios.
5. NO inserte los dedos, varillas u otros objetos dentro de la entrada o salida de aire. Esto puede causar
lesiones, debido a que el ventilador puede estar girando a altas velocidades.
6. NO use atomizadores inflamables cerca de la unidad como espray para el pelo o de pintura. Esto puede
causar incendios o combustión.
7. Se debe almacenar la unidad previniendo que le ocurran daños mecánicos.
8. Observe el cumplimiento de las regulaciones nacionales sobre el gas.
9. Lea atentamente las precauciones de seguridad antes de realizar la instalación.
10. En algunos entornos funcionales como las cocinas, comedores, etc., se recomienda el uso de
unidades de aire acondicionado especialmente diseñadas para estos espacios.
11. Solo técnicos capacitados y certificados deben instalar, reparar y dar servicio a esta unidad de aire
acondicionado.
12. Una mala instalación, reparación puede provocar descargas eléctricas, cortocircuitos, fugas,
incendios u otros daños al equipo y pérdidas materiales.
13. Siga estrictamente las instrucciones de instalación establecidas en este manual.
14. Antes de instalar la unidad, tenga en cuenta los vientos fuertes, los tifones y los terremotos que
puedan afectar a su unidad y ubíquela en consecuencia. Si no lo hace, el equipo podría fallar.
15. Los niños a partir de 8 años y personas enfermas con conocimiento del aparato y sus riesgos, pueden
manipular el equipo. Los niños no deben jugar con el equipo. Ni tampoco pueden realizar la limpieza ni el
mantenimiento del equipo sin supervisión.
16.No acelere el proceso de desescarche o la limpieza, cumpla con las recomendaciones del fabricante.
17. Este aparato no está diseñado para que lo usen niños pequeños o personas enfermas sin
supervisión.
18. Se debe supervisar que los niños no jueguen con la unidad. (Requisito de la
norma IEC)

4
ADVERTENCIA
19. Si la entrada de alimentación está dañada, debe ser sustituida por el fabricante, su distribuidor o un técnico
especializado para evitar riesgos.
20. La unidad se debe instalar teniendo en cuenta las regulaciones nacionales vigentes sobre el cableado.
21. Se debe instalar un dispositivo de desconexión de todos los polos que tenga una distancia mínima de 3 mm en
todos los polos y una corriente de fuga que pueda superar los 10 mA, el dispositivo de corriente residual (RCD)
con una corriente de funcionamiento residual nominal no superior a 30 mA, y la desconexión debe
incorporarse en el cableado fijo de acuerdo con las normas de cableado.
22. La desconexión del aparato debe estar incorporada en el cableado fijo con un dispositivo de desconexión
de todos los polos, de acuerdo con las normas de cableado.
23. Cualquier persona que se encargue de manipular los refrigerantes debe estar certificado para esta labor
con el reconocimiento de la industria.
24. El mantenimiento solo se puede realizar como lo recomienda el fabricante.
25. El mantenimiento y la reparación que necesiten la asistencia de otra persona cualificada se debe
realizar bajo la supervisión de una persona competente en el uso de refrigerantes inflamables.
26. Se debe almacenar la unidad previniendo que le ocurran daños mecánicos.
27. Mantenga sin obstrucciones las aberturas de ventilación.
28. No encienda la unidad hasta que haya terminado todo el trabajo.
29. Al mover o reubicar el aire acondicionado, consulte a técnicos de servicio experimentados para la
desconexión y reinstalación de la unidad.
30. En algunos entornos funcionales como las cocinas, comedores, etc., se recomienda el uso de
unidades de aire acondicionado especialmente diseñadas para estos espacios.
31. El desmontaje del tapón debe ser tal que el operador pueda comprobar desde cualquiera de los
puntos a los que tenga acceso que el tapón permanece desmontado.
32. Si esto no es posible, debido a la construcción del aparato o a su instalación, deberá preverse una
desconexión con un sistema de bloqueo en la posición aislada.

ADVERTENCIAS DE LIMPIEZA Y MANTENIMIENTO


1. Apague el dispositivo o desconéctelo antes de limpiarlo. De lo contrario puede causar descargas eléctricas.
2. No limpie el aire acondicionado con excesiva cantidad de agua.
3. No limpie el aire acondicionado con productos de limpieza inflamables. Los productos inflamables pueden
causar deformación. Apague el dispositivo o desconéctelo antes de limpiarlo. De lo contrario puede causar
descargas eléctricas.

ADVERTENCIAS RELACIONADAS CON LA ELECTRICIDAD


1. Solo use el cable de alimentación especificado. Si la entrada de alimentación está dañada, la deberá sustituir
un técnico especializado para evitar riesgos.
2. Mantenga limpia la conexión a la corriente. Elimine el polvo o la suciedad acumulada en el enchufe o
alrededor. Un enchufe sucio puede provocar incendios o descargas eléctricas.
3. No tire del cable de alimentación al desconectar la unidad. Sujete el enchufe firmemente y sáquelo de la toma.
Si tira directamente del cable puede dañarlo, lo cual puede provocar incendios o descargas eléctricas.
4. No use un cable extensor, ni extienda manualmente el cable de alimentación ni conecte otros equipos en la
misma salida que el aire acondicionado.
Las malas conexiones eléctricas, el mal aislamiento y bajo voltaje pueden causar incendios.

5
PRECAUCIÓN
 
En el caso de las unidades con calefactor eléctrico auxiliar, no instale la unidad a una distancia de menos de
1 m (3 pies) de cualquier material combustible.
No instale la unidad en un lugar donde esté expuesto a fugas de gases combustibles. Si el gas
combustible se acumula alrededor de la unidad puede provocarse un incendio.
No instale el equipo en habitaciones con humedad como un baño o habitación para lavar. El exceso de
exposición al agua puede provocar que los componentes eléctricos tengan un cortocircuito.
1. El producto tiene que tener una buena conexión a tierra desde el momento de la instalación o pueden producirse
descargas eléctricas.
2. Instale las tuberías de drenaje según las instrucciones de este manual. Un mal drenaje puede causar
inundaciones o filtraciones en la vivienda o en la propiedad.
3. NO toque la salida de aire mientras la lama oscilante esté en movimiento. Los dedos pueden quedar
atrapados o se puede romper la unidad.
4. NO inspeccione la unidad por su cuenta. Pida a un distribuidor autorizado que realice la inspección.
5. Para evitar el deterioro del producto, no utilice el aire acondicionado con fines de conservación (almacenamiento
de alimentos, plantas, animales, obras de arte, etc.).
6. NO toque las bobinas del evaporador dentro de la unidad interior. Las bobinas del evaporador son afiladas y
pueden causar lesiones.
7. NO manipule el aire acondicionado con las manos mojadas. Puede ocasionar riesgos de descargas eléctricas.
8. NO coloque objetos bajo la unidad interior que se pueden dañar debido a la humedad.
9. La condensación puede producirse a una humedad relativa del 80%.
10. NO exponga los aparatos que producen calor al aire frío ni los coloque debajo de la unidad interior.
11. Puede provocar incendios o deformar la unidad debido al calor.
12. Después de largos períodos de uso, revise la unidad interior para ver si hay algo dañado. Si la unidad interior
está dañada, puede caerse y causar lesiones.
13. Si el aire acondicionado se usa junto con quemadores u otros dispositivos calefactores, ventile bien la
habitación para evitar la deficiencia de oxígeno.
14. NO se suba encima a la unidad exterior ni coloque objetos encima.
15. NO utilice el aire acondicionado cuando se fumigue. Los productos químicos pueden formar capas con la
unidad y poner en peligro a quienes son hipersensibles a los productos químicos.
16. NO permita que los niños jueguen con el aire acondicionado.
17. NO instale el equipo en habitaciones con humedad como un baño o la habitación para lavar.
18. Esto puede provocar descargas eléctricas y que el producto se deteriore.

Precauciones para el uso del refrigerante R32

1. Instalación (espacio)
- Que el trabajo de instalación de tuberías se reduzca al mínimo.
- Dicha tubería deberá estar protegida de daños físicos.
- Observe el cumplimiento de las regulaciones nacionales sobre el gas.
- Que las conexiones mecánicas sean accesibles para fines de mantenimiento.
- En los casos que requieran ventilación mecánica, las aberturas de ventilación deberán mantenerse libres de
obstrucciones.
- Cuando se utilice el producto para su eliminación, se basará en la normativa nacional y se procesará
adecuadamente.
- La unidad se debe guardar en una zona bien ventilada donde el tamaño de la habitación corresponda con
los valores especificados del área para su funcionamiento.
- Espacios donde las tuberías de refrigerante deben cumplir con las regulaciones nacionales de gas.
2. Mantenimiento
- Cualquier persona que se encargue de manipular los refrigerantes debe estar certificado para esta labor
con el reconocimiento de la industria.
- El mantenimiento solo se puede realizar como lo recomienda el fabricante. El mantenimiento y la reparación
que necesiten la asistencia de otra persona cualificada se debe realizar bajo la supervisión de una persona
competente en el uso de refrigerantes inflamables.

6
Precauciones para el uso del refrigerante R32
 
3. No acelere el proceso de desescarche o la limpieza, cumpla con las recomendaciones del fabricante.
4. La unidad se debe guardar en una habitación sin fuentes de calor activa (p.ej.: llamas abiertas, una cocina de
gas o un calefactor eléctrico).
5. No perfore ni queme la unidad.
6. Asegúrese de que los refrigerantes no despidan olor.
7. Tenga mucho cuidado de que no entren cuerpos extraños (aceite, agua, etc.) en la tubería. Además, al
almacenar la tubería, selle con seguridad la abertura y pegue con cinta adhesiva.
Para las unidades interiores, utilice el conjunto de unión no abocardado R32 solo cuando conecte la unidad
interior y conecte las tuberías (cuando conecte en interiores). El uso de tuberías, tuercas sin abocardar o
tuercas de ensanchamiento distintas a las especificadas, puede causar el mal funcionamiento del producto,
rotura de tuberías o lesiones debido a la alta presión interna del ciclo del refrigerante causada por cualquier
aire de entrada.
2
8. El equipo se debe instalar, hacer funcionar y guardar en una habitación que tenga una superficie mínima de 4 m .
El aparato no debe instalarse en un espacio sin ventilación, si dicho espacio es inferior a X m² (véase el siguiente
formulario).

Cantidad de Altura de instalación (m) Superficie


Modelo (kBTU/h)
refrigerante (kg) mínima de la
sala (m²)
≤2,048 2,2m 4
≤30 ≤2,048 1,8m 4
≤2,048 0,6m 35
2,048-3,0 2,2m 4
36-42 2,048-3,0 1,8m 8
2,048-3,0 0,6m 80

Observaciones sobre los gases fluorados


1. El aire acondicionado contiene gases fluorados de efecto invernadero. Para más información sobre este
tipo de gas y la cantidad, consulte la etiqueta correspondiente en el propio equipo.
2. La instalación, el servicio, el mantenimiento y la reparación se debe realizar por un técnico autorizado.
3. Para desmontar el equipo y reciclarlo debe contactar con un técnico especializado.
4. En el caso de los aparatos que contengan gases fluorados de efecto invernadero en cantidades iguales o
superiores a 5 t de equivalente de CO2, pero inferiores a 50 t de equivalente de CO2, si el sistema tiene
instalado un sistema de detección de fugas, deberá comprobarse su estanqueidad al menos cada 24 meses.
5. Es muy recomendable que cada vez que se realicen inspecciones en busca de fugas se mantenga un registro
de todas las incidencias.

Descripción de símbolos mostrados en la unidad interior o exterior:

Este símbolo muestra que esta unidad usa un refrigerante inflamable. Si hay
ADVERTENCIA fugas de refrigerante y queda expuesto a una fuente de calor externa, existe
riesgo de incendio.

PRECAUCIÓN Este símbolo muestra que el manual de instalación y usuario se debe leer
cuidadosamente.

PRECAUCIÓN Este símbolo muestra que el personal de mantenimiento debe manipular


este equipo teniendo en cuenta el manual de instalación.
PRECAUCIÓN
Este símbolo muestra que la información está disponible en el manual de
PRECAUCIÓN instalación y usuario.

7
MANUAL DE INSTALACIÓN
1. Instalación de la unidad interior
ción de la placa de montaje de
Instalac d la unida
ad interiorr
La placa de montaje
e debe instalarse en una paz de soporrtar el peso de la
a pared cap
unidad interior.

1) Coloq que la placca de montaje en la pared, com mpruebe qu ue la placa está


comp pletamente nivelada,
n y marque los pu untos de perfforación en la
a pared.
2) Aseg gure la placa de montaje a la pared por medio de los tornillo os. Se recom
mienda
ar entre 5 y 8 puntos de fijación. Rea
utiliza alizar los agu
ujeros con uuna broca de
e 5mm
de diáámetro.

Orientación correcta de la placa de montaje

o de orificio en la pa
Taladro ared e instalación al
a exterior Pared
En las paredes de pladur
p o con n bastidor metálico
m es necesario
n ussar un tubo pasa- Exterior
muros pa ara evitar cu ualquier riesg
go por la formación de calor, desca argas eléctriicas o Interior

incendio.
1) Realiice un agujerro de 65 mm m en la pared con inclinacción descenddente al exterrior.
2) Inserrte el tubo pa asa-muros y la tapa del tu
ubo si fuera necesario.
n
3) Inserrte los eleme entos de la instalación; tubos
t refrige
erantes, cableeado y tubería de
drenaaje.
4) Selle con masilla los hueccos que se produzcan entre los elementos de la
installación y el pa
asa-muros.

Dimensiones de la placa de montaje

Modelo 09 y 12 Modelo 18

Modelo 24 8
Instalac
ción de la unidad in
nterior
1) Tube
ería de drena aje
- Instale la tubería de drenaje con
c
pendiente descen ndiente. No instale
el tub
bo como se muestra
m en la
a figura.
- Si pro olonga la tub naje aísle la parte
bería de dren p extenddida.
- Cuan ndo termine de instalar laa unidad, saaque los filtro
os de aire y vierta
un po oco de agua ería para verrificar que ell agua sale por el
a por la bate
tubo de drenaje.
2) Tube
erías
- Coloq que la tube ería de drenaje en la parte inferrior de los tubos
gerantes y únala con cin
refrig nta adhesiva a. También una la man nguera
eléctrrica.
Sitúe la tubería de
drenaje en la
Manguera parte inferior,
eléctrica como se muestra
en el dibujo
Tuberías Cubierta para instalación
i
refrigerantes Lado izquierdo
o
nstalación
Cubierta para in
Tuberíía de Protección Lado derecho
drenajje tuberías

- Pase e los elementtos unidos po


or el orificio de
d la pared y luego cuelg
gue la
unidaad interior en
n los ganchos
s de la placa a de montaje
e. Mueva la unidad
u
de izzquierda a derecha para a asegurar que q este bien colocada en su
sitio.

- Aseggúrese de que la mang guera eléctricca llega a llos terminale


es de
conexxión.
- Presiione la parte
e inferior izq
quierda y deerecha de laa unidad con ntra la
placa
a de montaje e hasta que se acople a los ganchos fijadores de la
placa
a de montajee.

2. Instalación de la unidad exterior


La unidad exterior debe ser instalada de acuerdo a los siguientes requerimientos:
- Hay suficiente espacio para la instalación y el mantenimiento.
- La entrada y salida de aire están despejadas, sin ningún obstáculo.
- Es un lugar seco y bien ventilado.
- El soporte está horizontal y preparado para soportar el peso de la unidad.
- No molesta a ningún vecino por el ruido o el aire expulsado.
- No impide la instalación de las tuberías frigoríficas ni el cableado.
- No hay peligro de incendio por fuga de gas.
- La longitud de tuberías entre la unidad externa e interna están dentro de las permitidas.
- Si es posible, intente que la unidad no quede expuesta al sol.
- Si la unidad es bomba de calor, el drenaje debe estar conducido.
- Evite que la unidad pueda ser cubierta por nieve, hojas u otros residuos. Si es
inevitable intente cubrirla con un toldo siempre que no se obstaculice el paso de aire.
- Mantenga las distancias mínimas indicadas en este manual.

9
Dimensiones Unidad Exterior
W1


B D

 

     
      
      
    

Espacio para la instalación y el mantenimiento


> 60 cm

> 30 cm
cm > 30

0 cm
> 20

> 60
cm

10
3. Instalación de las tuberías de refrigerante
Antes de rea
A alizar la insta
alación, asegúrese de que
q la difere
encia de altu
ura, la longitud de
tu
ubería refrigerante y el número
n de curva
c entre la unidades interiores y exterior, cummplen
c los siguie
con entes datos:
Longitudes de tubería máximas: Diferencias de altura máximas:
AM2 AM3 AM4 / AM5 Ud. Exterior Ud. Interior
UNIDAD (2x1) (3x1) (4x1 / 5x1)

Maxima longitud frigorifica (m) 40 60 80 Ud. Interior

Maxima longitud por unidad interior (m) 25 30 35 10m

Maxima diferencia entre la U. Ext mas alta 15 *(1) 15 *(1) 15 *(1)


U. exterior y las interiores (m) U. Ext mas baja 15 15 15
5m

Max. diferencia de altura entre U. interiores (m) 10 10 10


10m

*(1) Nota: Si la unidad exterior esta instalada por encima de las interiores Ud. Interior
y la suma de todas las alturas es superior a 7m, se debe instalar una
trampa de aceite en la tubería de gas cada 3 metros.

C
Carga adic
cional de refrigeran
r ción de la línea de lííquido
te en func

UNIDAD AM2 (2x1) AM3 (3x1) AM4 (4x1) AM5 (5x1)

Precarga hasta 15m 22,5m 30m 37,5m

Carga Adicional
R32 (g) 20 x (longitud total - 15) 20 x (longitud total - 22,5) 20 x (longitud total - 30) 20 x (longitud total - 37,5)

Tubería
a frigorífic
ca
1) A
Abocardadoo del extremo o del tubo
- Corte e el extremo del tubo conn un corta-tubbos.
- Elimine las rebab bas dirigienddo la superficcie de corte hacia abajo
o para
evitarr que entre virutas
v dentro
o del tubo.
- Pong e el interior del tubo.
ga la tuerca en
- Proce eda a abocardar el tubo.
- Verifiique que el abocardado
a está
e correcta
amente realizzado.

Diam. Ext. A(mm)


 (mm) Max. Min.
6.35 1.3 0.7
9.52 1.6 1.0
12.7 1.8 1.0
16 2.2 2.0
"A"

Manivela
Barra Barra
90O Oblicuo Irregular Rugoso

Manivela
Tubo de cobre de sujeción

11
2) Conexionado o del tubo
- Alinee las tubería as a conectarr.
- Aprieete la tuerca a con los dedos
d y possteriormente utilice una llave
inglessa con cuidaado de no rommper la tuercca.
n, la siguiente tabla le muestra la fue
- Si utiiliza una llavve de torsión erza a
aplica
ar:

Par de
Diametro apriete(N.cm) Par adicional de
apriete(N.cm)
1500 1600
φ 6.35mm (153kgf.cm) (163kgf.cm)
2500 2600
φ9.52mm (255kgf.cm) (265kgf.cm)
Tubos
3500 3600 Tubos unidad interior Tuercas abocardar
φ12.7mm (357kgf.cm) (367kgf.cm)
4500 4700
φ 16mm (459kgf.cm) (479kgf.cm)

3) Vacio y co
omprobación de fugas

- La humedad y el e aire en el sistema frig gorífico puedden tener effectos


indesseables. Lass tuberías debend estarr completam mente secas s y a
prueb ba de fugas. Esto requiere el uso de d una bomba de vacío o y un
comp probador de fugas.
- Aprieete bien las tuuercas A, B, C y D.
- Cone ecte la manguera de carg ga del manómmetro a la bo omba.
- Cone ecte la mang guera de ba aja presión del manóme etro a la llav
ve de
serviccio de la máq quina.
- Abra completame ente la llave
e de baja ba aja presión del manóme etro y
cierree la de alta presión.
p
- Arrannque la bomba de vacío y mantenga a la bomba ffuncionando entre
30 min (<15m) y 1 hora (>15m m) en funciónn la longitud de tuberías.
- Cierre la llave del manómetro o de baja y compruebe
c que la presiónn está
en -7 76cmHG (-1bar). Esperre unos minutos para ccomprobar que q la
agujaa se mantiene en esta presión y por tanto
t no hay fugas.
- Abra con una lla ave hexagon nal completaamente las llaves de se ervicio
para dejar salir ele gas de la unidad exterior a la insttalación y re etire la
mang guera de la máquina. Apriete bien el e tapón parra evitar cua alquier
fuga de gas.
- Utilice un detecttor de fugas para com mprobar si h hay fugas ene las
unionnes. Si no dispone de e un detecttor, utilice a agua jabono osa y
comp pruebe si se forman burb bujas.
Manómetro

-76cmHg
Tuerca
Refrigerante cónica
Unidad unidad Lado bajaa presión Lado alta presión
exterior A interior Tapón
Lado gas C
tapa
Lado líuqido D
Bomba de vacio
B Valve body
válvula de corte válvulas de unión Valvula

Válvula de servicio

12
4. Instalación eléctrica
Normas de seguridad

- La teensión de alimentación debe estar en un intervvalo del 90% % y el


110%% de la tensió ón nominal.
- El intterruptor magnetotérmico o y el interru
uptor diferenccial deben ser 1,5
vecess superior al consumo no ominal (ver taabla en la pa
arte inferior).
- Todaa la instalació
ón y cablead do deben cumplir con lass normal locales y
nacioonales y la in
nstalación de
ebe ser realizzada por perssonal cualificcado.
- La se ección mínimma del cable eado debe ser se selecciona en función del
consumo de cada modelo.

exionado y alimentació
Cone a n eléctrica unidad exterior
Tornillo
1. Retire la cubierta del conexionado o eléctrico seegún
se muesttra en la figurra. Cubierta

2 Conecte los cables de


2. e interconexión entre el bloque
b
de terminnales de la un or y las interiores,
nidad exterio
respectivamente.
3 Asegure el cable utilizzando la brid
3. da existente ene la unidad exterior.
4 Aísle los cables no uttilizados (con
4. nductores) pa ara que no se
s produzca nninguna descarga
eléctrica.

              


AM2 / AM3       
AM4 / AM5    

Cableado de interconexión entre la unidad exterior y las unidades interiores


Para la interconexión entre la unidad exterior y cada unidad interior, usar cable de 3x1,5mm + T.

Terminales
Unidad Exterior
    
              

230V - 50Hz

No conectar

           
Ud. Interior Pared (AMW) Otras uds. Interiores Cassette o Conducto

Terminales
Unidad Interior

Nota:
1. Las unidades interiores de pared tienen un terminal de conexión Lo que se debe dejar sin conectar.

13
5. Instalación drenaje de la unidad exterior
- Colocar la junta de drenaje con junta estanca (Fig.A), primero coloque la
junta estanca en la junta de drenaje y después en la base de la bandeja
de la unidad exterior, gire 90º para estar seguro de su colocación .
Junta Boquilla Orificio bandeja
- Para instalar la junta de drenaje como se muestra en la Fig.B, de desagüe colectora de la
unidad exterior
insertelo después en la bandeja de la unidad exterior, en el agujero
de la base de la bandeja hasta que oiga un click que la fijación se
se ha completado correctamente. Conecte a la junta de drenaje
con una extensión a la tubería de drenaje (Comprado por cliente). (A)
(B)
NOTA: La junta de drenaje será diferente en función de cada unidad exterior.

6. Puesta en marcha y pruebas de funcionamiento

Comprobaciones prévias
- Mida el voltaje de suministro y asegúrese de que está dentro del
margen especificado.
- La prueba de funcionamiento debe ser realizada en todos los modos
de funcionamiento.
- Para hacerla funcionar en frío, pulse el botón marcha/paro del control
remoto, ponga la unidad en modo Cool y seleccione una temperatura
por debajo de la temperatura ambiente.
- Para hacerla funcionar en calor, pulse el botón marcha/paro del control
remoto, ponga la unidad en modo Heat y seleccione una temperatura
por encima de la temperatura ambiente.
- Puede también comprobar el botón de arranque manual. Este se usa
cuando no disponemos de control remoto y se encuentra debajo del
panel frontal en las unidades de pared.

14
MANUAL DE USUARIO
1. Descripción y funcionamiento
Partes
a) Split de pared
Unidad Interior Unidad C
1. Panel frontal
2. Rejillas entrada de aire
3. Filtro (bajo el panel)
4. Salida de aire
5. Lama horizontal air-swing (automatica)
6. Lama vertical air-swing (en interior, manual) Unidad B
7. Display
8. Receptor de infrarrojos
9. Control remoto
10. Botón manual de emergencia (en interior)
X Z V Z[

Unidad Exterior Unidad A

11. Tuberia refrigerante, desague y manguera eléctrica.


12. Válvulas
UW ] Y
\
13. Rejilla de descarga de aire klm
ndgc
ghciU tdcUcdefd
aiij

cdef
lgchl
dU_àb

nq
ogp
edkrn
jis
eikd
UUUUUt
sqpr
ipuioo
tjddf ogpUtfddk

UkUqlUUdacq
UgqlU cqedlU
ldtdcU ip
ip jiav
cqe dlUioo
UUUkUqUtUjdk
fjgm
UUUUc
hlwi

Display

La unidad mostrará el ajuste de temperatura de consigna.


En el modo Fan (ventilación) la unidad mostrará la temperatura
ambiente de la habitación.

15
b) Conducto c) Cassette

Unidad E
Unidad E

Unidad D
Unidad D

Unidad C Unidad C

Unidad B Unidad B

Unidad A
Unidad A




Unidad Interior Unidad Interior


1. Bomba de condensados 
1. Salida de aire
2. Conexión drenaje
2. Entrada de aire
3. Salida de aire
3. Filtro de aire
4. Entrada de aire
4. Caja eléctrica
5. Rejilla de entrada de aire
5. Control remoto
6. Pantalla indicadora

Unidad Exterior 7. Control remoto

6. Tuberia refrigerante, drenaje Unidad Exterior


7. Cable de interconexión
8. Tuberia refrigerante, drenaje
8. Válvula de servicio 9. Cable de interconexión
9. Rejilla de salida de aire 10. Válvula de servicio
11. Rejilla de salida de aire

16
 
Limites de funcionamiento
Este acondicionador de aire ha sido diseñado para las siguientes temperaturas. Manténgalo en
funcionamiento dentro de estos márgenes

Modo
Refrigeración Calefacción
Temperatura
Temperatura interior > 18ºC < 32ºC
Temperatura exterior -15º ~ 52ºC -15º ~ 24ºC

Nota
Si se hace funcionar el equipo fuera de este rango de temperaturas, éste podrá funcionar de
forma anómala.
Con un rango de humedad relativa alta, es normal que la unidad interior de la máquina
funcionando en modo frío condense mucha agua.
El punto óptimo de trabajo del equipo se encuentra en la zona media dentro de este rango de
temperaturas.

Funcionamiento manual
El funcionamiento manual puede emplearse de modo temporal si el mando a distancia no
funciona o si la unidad precisa de mantenimiento.

1 Abra y levante el panel frontal hasta que este


se quede fijado tras el sonido de un clic.
2 Al pulsar el botón de control manual, la unidad
operará en modo AUTO.
AUTO a) Si la unidad está apagada, puede pulsar el botón
Auto para encenderla.
b) Si la unidad está encendida, puede pulsar el botón
Auto para apagar.
3 Cierre el panel frontal hasta que quede fijado
en su posición inicial.

Consejos para un funcionamiento óptimo


Ajuste la dirección de salida de aire para que esta no incida directamente sobre las personas.
Ajuste a temperatura de consigna para conseguir el mayor confort posible.
Cierre puertas y ventanas mientras la unidad se encuentre en los modos de calefacción y
refrigeración.
Utilice el botón TIMER ON del control remoto para establecer el momento de encendido que
usted desea.
No obstaculice la entrada o salida de aire con ningún objeto.
Limpie los filtros periódicamente como se indica en este manual.

17
 
Modos de funcionamiento

1. Modo AUTO
Cuando se elije el modo AUTO, la unidad
seleccionará automáticamente el modo de
funcionamiento (calor/frío/ventilación) en
función de la temperatura de consigna y la
temperatura interior de la habitación.
La unidad controlará la temperatura
automáticamente en función de la temperatura
de consigna establecida por el usuario.
Si el modo AUTO no le resulta confortable,
usted puede seleccionar las condiciones que
desee de forma manual.

2. Modo SLEEP
Cuando pulse el botón SLEEP en el control Refrigeración:
remoto mientras la unidad se encuentra en 8 !I%56 !I356 Mantiene la temp. Se detiene
modo automático, refrigeración o calefacción, la !56 1a hora 2a hora durante 5 horas auto.
unidad incrementará (en refrigeración) o
Calefacción:
disminuirá (en calefacción) automáticamente
8 !356 !'56 Mantiene la temp. Se detiene
la temperatura de consigna. auto.
!56 1a hora 2a hora durante 5 horas
La unidad se detendrá automáticamente a
las 7 horas desde la activación de la función.

Control de la dirección del flujo de aire

Ajuste correctamente la dirección del flujo de aire.


ATENCIÓN
De lo contrario, podría causar sensaciones molestas
e incluso temperaturas inestables. No opere la unidad de manera prolongada con la dirección
del aire ajustada hacia abajo en modo frío o en modo
Adjuste la rejilla horizontal utilizando el mando a
deshumidificador. De lo contrario, podría acumularse
distancia. condensación en la superficie de la rejilla horizontal y
Adjuste la rejilla vertical de manera manual. causar humedad en el suelo o el mobiliario.
No mueva la rejilla horizontal de manera manual a menos
Fijación de la dirección del flujo de aire vertical (arriba-abajo):
que sea necesario. Utilice siempre el mando a distancia.
Utilice esta función durante el funcionamiento de la Cuando se encienda el aire acondicionado inmediatamente
unidad. Utilice el mando a distancia para ajustar la después de su parada, la rejilla horizontal podría permanecer
dirección del flujo de aire. La rejilla horizontal puede inmóvil durante aproximadamente 10 segundos.
moverse en un ángulo cada vez, o bien oscilar El ángulo de abertura de la rejilla horizontal no debería ser
automáticamente de arriba hacia abajo. Consulte el demasiado reducido, ya que, de ser así, los modos FRÍO y
CALOR podrían no funcionar bien por la restricción del aire.
manual de funcionamiento del mando a distancia para
No opere la unidad cuando la rejilla horizontal esté en
más información. su posición de cierre.
Fijación de la dirección del flujo de aire horizontal (izq-dcha): Al conectar el aire acondicionado a la toma de corriente
Mueva la rejilla vertical manualmente para ajustar la (encendido inicial), la rejilla horizontal podría emitir un
sonido durante aproximadamente 10 segundos.
dirección del flujo de aire deseada.
IMPORTANTE: Antes de ajustar las rejillas verticales, des-
conecte la fuente de alimentación.
En algunos modelos, la rejilla vertical puede ajustarse
utilizando el mando a distancia. Consulte el manual
de funcionamiento del mando a distancia para más
información.

18
2. Cuidado y mantenimiento

Limpieza de la rejilla y la carcasa

Apague el sistema antes de proceder a su limpieza. Utilice


un trapo suave y seco para limpiar la unidad. No use lejías
ni materiales abrasivos.
NOTE: El cable de corriente debe estar desconectado antes de
proceder a la limpieza de la unidad interior.

ATENCIÓN
Puede usarse un trapo humedecido con agua fría
para limpiar la unidad interior si esta está muy sucia.
Frotar con un trapo seco para finalizar la limpieza.
No utilice un trapo con contenido químico o un paño
de limpieza para limpiar la unidad.
No utilice gasolina, disolvente, pulimento en polvo
Pestañas del filtro
o productos similares para la limpieza de la unidad.
La superficie de plástico podría agrietarse o deformarse.
No utilice agua a más de 40ºC (104ºF) para limpiar
el panel frontal. Podría causar deformaciones o
decoloraciones en el mismo.

Limpieza del filtro de aire

Un filtro de aire obstruido reduce la eficiencia de enfriamiento


de la unidad. Limpie el filtro de aire cada dos semanas.
1. Abra y levante el panel frontal hasta que este
se quede fijado tras el sonido de un clic. Filtro de aire fresco

2. Agarre el asa del filtro y tire de él suavemente para


extraerlo del portafiltros. A continuación, tire hacia
abajo.
3. Extraiga el filtro de aire de la unidad interior.
Limpie el filtro de aire una vez cada dos semanas.
Limpie el filtro de aire con una aspiradora o con agua.
Séquelo en un lugar fresco.
4. Extraiga el fitro de ventilación de aire de su soporte
(en algunos modelos).

Limpie el filtro de ventilación de aire al menos una


vez al mes y sustitúyalo cada 4-5 meses.
Límpielo con un aspirador. Séquelo en un lugar
fresco.

5. Coloque el filtro de ventilación de aire en su posición


original.
6. Inserte la parte superior del filtro en la unidad. Procure
que los bordes izquierdo y derecho estén correctamente
alineados. A continuación, fije el filtro en su posición.

19
Si va a dejar la unidad si funcionamiento durante un largo periodo, lleve a cabo lo siguiente:

- Haga funcionar el ventilador interior durante varias horas para secar el interior de la
unidad.
- Pare la unidad, desconéctela de la alimentación y retire las pilas al mando a distancia.
- Limpie los filtros.

Se recomienda hacer un mantenimiento del equipo como mínimo una vez al año. Debe ser
comprobado:

- El refrigerante del equipo.


- El buen funcionamiento de los motores.
- Las conexiones eléctricas.
- Las baterías tanto interior como exterior.

Este mantenimiento debe ser realizado por un especialista, es necesario y de obligado


cumplimiento según el RITE. El coste de mantenimiento corre a cargo del usuario.
Los siguientes eventos pueden ocurrir durante el funcionamiento normal de la unidad:

1) Protección del acondicionador de aire:


- El compresor no puede reiniciar durante 3 minutos después de que se detenga.
- Prevención de aire frío. En modo calefacción la unidad está diseñada para funcionar de
la siguiente forma:
A) Cuando la calefacción acaba de comenzar, el ventilador interior no arrancará hasta
que la batería este caliente y lo hará progresivamente para no dar la sensación de
frío.
B) El ventilador interior y exterior se pararán cuando la unidad esté en proceso de
descongelación. El tiempo de descongelación puede variar entre 4 y 10 minutos en
función de la temperatura exterior y de la escarcha de la unidad exterior.

2) Olor en la unidad interior: compruebe que el filtro está limpio. Si el filtro está limpio es posible
que la batería esté impregnada de humo o malos olores. Para su limpieza debe llamar a un
especialista.

3) Gotea agua la unidad interior: es posible que si la humedad es superior al 80% gotee agua la
unidad interior. Ponga la lama de salida de aire totalmente horizontal y seleccione la velocidad
máxima del ventilador.

20
3. Solución de problemas

Si se produce alguno de los siguientes errores, detenga el aire acondicionado inmediatamente,


desconecte la corriente y, a continuación, vuelva a conectarlo. Si el problema persiste, desco-
necte la corriente y contacte con el servicio de atención al cliente más próximo.
El indicador de funcionamiento u otros indicadores continúan parpadeando.
El fusible falla o el disyuntor se activa con frecuencia.

Problema Objetos o agua penetran en el aire acondicionado.


El mando a distancia no funciona o presenta un funcionamiento anormal.
Si uno de los siguientes códigos aparece en la pantalla frontal:
E0,E1,E2,E3, P0,P1,P2,P3,... (ver página siguiente)

Avería Causa Procedimiento


Corte en el suministro eléctrico. Espere a que se reestablezca el suministro.

Compruebe que el conector se ha enchufado


La unidad puede estar desenchufada.
correctamente a la toma de corriente

La unidad El fusible puede haber fallado. Sustituya el fusible.


no arranca
Las pilas del mando a distancia Sustituya las pilas.
pueden haberse gastado.

La hora del temporizador configurada Espere o cancele la configuración


es incorrecta. del temporizador.

La configuración de la temperatura Configure la temperatura correctamente.


no es correcta. Para más detalles, consulte la sección
La unidad no
“uso del mando a distancia”.
enfría o calienta
(solo en modelos
frío/calor) la El filtro de aire está obstruido. Limpie el filtro de aire.
habitación lo Hay puertas o ventanas abiertas. Cierre puertas y ventanas.
suficiente mientras
sale aire del aire La entrada o salida de aire de la unidad Elimine cualquier obstáculo y, a
acondicionado exterior han quedado bloqueadas. continuación, reinicie la unidad.

Se ha activado la protección
Espere.
de 3 minutos del compresor.

Si no se ha solucionado el problema, contacte con su proveedor o servicio de atención al cliente


más próximo. Asegúrese de informar de los detalles del problema y del modelo de la unidad.

Nota: No intente reparar la unidad usted mismo. Contacte con un técnico de servicio autorizado.

21
Listado de códigos de error:
 ! " # 
 !"!!#$"$!$$
 !"!"#$!%!"$!$
 !"!"#$!"$!$$
 &$!!"$!$$#!!!'!'$'!
   '"$'!'$("$!$$)$
 '"$'!'$("$!$$)!!'!$!)
*+ ("-./-&0"$!$
* &$!!"$!$#!!!'!'$'!
* ("*1"$!$
* !!!'!!'
* !"!'!%!"$!$
''$(!"!!'!'!!'
*
!"!!'!'!!'
* !"!!#$"$!$
* ''$(&!2/"$$3$0
* '"$'!'$(!'!!"$!$/$'$!-&0
* 45.!"$!$
* !"!!$!'$("$!$
6 !2!"$!$$
6 '"$'!'$("$!$$)''!#!
6 !"!"#$!78"$"!"$!$$!"$!$
6 !"!"#$!%!"!"$!$$!"$!$
6 ''$(#!2!!"!!'!%!'
6 ''$($"#!2!$(
6 ''$(#!2!$(
6 !&9&"!&7!
6 '$(7!'"$'!'$(
+ ''$(!&!%&$!$$
+ ''$(#'$'!"$!$
+ !!'$('
+ *!!"!3!'
+ ''$(/:3;!0("*1"$!$
+ ''$(/6!;!0("*1"$!$
+ +1 ''$(!!$!<=("*1
+ 8"$$#$!3!'=!''$!$
+ !"!("-&!"$!$
+ !!!'!!'
+< ''$(!!$!<=("*1&$!
+ *!!"!3!&$!"$!$
+* ''$(&$!3"!'"$!$
+6 ("-./-&0&$!"$!$
 ''$(#'$!"$!$
 ''$(!!!"!!'!%!'
 ''$(#"''$('$'"$3$%73$'
 ''$(!!!"!!"$!$$'!3!''$(
 ''$(!$'%!$
 ''$($"!!$(
 ''$(3"%!3$%!

4. Requisistos para la eliminación


Su producto y las pilas suministradas con el control remoto vienen marcadas con este
símbolo.
Este símbolo significa que los productos elctricos, electrónicos y las pilas no deben
mezclarse con el resto de residuos domésticos no clasificados.
En el caso de las pilas puede aparecer un símbolo impreso bajo el símbolo, esto significa
que las pilas contienen un metal pesado que se encuentra por encima de una determinada
concentración. Estos son los posibles símbolos químicos.
3 Pb: plomo (>0,004%)
No intente desmontar el sistema usted mismo. El desmantelamiento del producto, así como el tratamiento del
refrigerante, aceite y otros componentes, debe ser efectuado por un instalador compentente de acuerdo con las
normas locales y nacionales aplicables.
Las uniades y pilas agotadas deben ser tratadas en instalaciones especializadas para su reutilización, reciclaje y
recuperación.
Al asegurarse de desechar este producto de la forma correcta, está contribuyendo a evitar posibles consecuencias
negativas para el entorno y para la salud de las personas.
Contacte, por favor, con el instalador o con las autoridades locales para obtener más información.
22
 

CONTROL REMOTO
Lea el presente manual con detenimiento antes de usar
el aire acondicionado y consérvelo para futuras consultas.

23
ESPECIFICACIONES 1

iFEEL

Modelo YKR-H

Voltaje nominal 3.0 V (Batería AAA x 2)


Rango de alcance 8m
de la señal
Temp. Ambiente -5ºC a 60ºC

NOTA:
El diseño de botones se basa en el modelo estándar y puede ser ligeramente diferente del que usted ha
adquirido, la forma real prevalecerá.
Todas las funciones descritas en el manual las realiza la unidad. Si la unidad no tiene esta función, cuando
pulse el botón correspondiente en el control remoto no tendrá efecto sobre la unidad.
Cuando haya grandes diferencias en la descripción de la función entre la “Ilustración del control remoto" y
el "Manual de usuario", la descripción del "Manual del usuario" prevalecerá.

24
FUNCIÓN DE LOS BOTONES 2
TRA NS MIT DIGITAL ON/OFF

S ET ROOM RUNNING
MODE
RUNNING
MODE SPEED

TIMER ON OFF

TI MER FEE LING

8 1
9 2

10 3
11 4
iFEEL
12 5
13
14 6

15 7

1. ON/OFF

2.
Pulsar este botón para seleccionar entre grados Celsius "ºC" o entre grados Fahrenheit "ºF".

3. SPEED

Low Mid High Auto

Nota: El modo automático de ventilación se se selecciona cuando no aparece seleccionada


ningúna velocidad (H/M/L).

25
4. DISPLAY

"DISPLAY".

5. iFEEL
"iFEEL"

6. TIMER

26
7. HEALTH / iCLEAN

Esta función realiza una auto limpieza en la unidad interior. Cuando se activa la función
"iClean", inicialmente la unidad funciona en modo refrigeración con el ventilador a baja
velocidad, durante este período el agua de condensación arrastra el polvo de la batería.
Seguidamente la unidad cambia a modo calefacción con el ventilador a baja velocidad,
para secar la bateria y el interior de la unidad. Finalmente la unidad cambia a modo
ventilación para terminar de secarse completamente.
Este botón también sirve para resetear el recordatorio de limpieza del filtro de aire,
código "CL", que se activa cuando la máquina alcanza las 360h de funcionamiento
acumulado. Pulsar 10 veces el botón "HEALTH" para resetear el contador.
Para desactivar el contador, pulsar 5 veces el botón "HEALTH".

8. o

9. TURBO

10. MODE

AUTO COOL DRY HEAT FAN

27
11. SLEEP
Esta función ayuda a ahorrar energia y aporta un mayor comfort durante la noche.
Si se activa, el equipo incrementa (en refrigeración) o disminuye (en calefacción)
automáticamente la temperatura de consigna 1ºC cada hora durante las primeras
2 horas, el equipo se detiene automaticamente a las 7 horas desde la activación
de la función.

Nota: Presione "MODE" o "ON/OFF" para cancelar la función.

12. SWING

13. SWING Este botón no tiene función en este equipo.

28
14. Anti-F
*La función Anti-F puede funcionar cuando la unidad se apaga con el mando a distancia
en los modos COOL, DRY, o AUTO. El equipo funcionará en modo HEAT, con el ventilador
a baja velocidad durante 3 minutos antes de la parada, para eliminar la humedad dentro
del evaporador con el fin de evitar que un desprendimiento de mal olor de moho.

* Esta función no viene ajustada de fábrica. Puede activarla o cancelarla en cualquier


momento que usted desee de la siguiente manera: Con la unidad y el mando a distancia
en OFF, apunte con el mando a distancia hacia la unidad y pulse el botón "Anti-F", presione
una vez, la alarma sonará 5 veces después de 5 veces, lo que indica esta función está
activada. Una vez activada, esta función será válida excepto cuando la unidad sea apagada
o hasta que se cancele.

* Para cancelar “Anti-F”:


1. Apague la unidad
2. Con la unidad y el mando a distancia OFF, apunte con el mando a distancia hacia la unidad y
pulse el botón una vez, el timbre sonará 3 veces después de 5 veces, lo que indica esta función
se cancela.

Nota:
* Con la función “Anti-F” activa, se recomienda no encender la unidad de nuevo
antes de que esté completamente apagado.
*La función “Anti-F” no será válida cuando se ajusta el temporizador de apagado.

15. Este botón no tiene función en este equipo.

29
FUNCIONAMIENTO 3

30
ATENCIÓN 4

CAMBIO DE BATERÍAS 5

31
 

INFORMACIÓN DE SERVICIO

Por favor, tenga en cuenta toda la información de servicio antes de realizar


cualquier tarea de instalación, mantenimiento o manipulación de este equipo
de aire acondicionado con gas R-32.

32
 
1. Comprobaciones de la zona de trabajo
Antes de comenzar el trabajo en los sistemas que contengan refrigerantes inflamables, son
necesarios los controles de seguridad para asegurar que el riesgo de incendio está
minimizado. Para reparar el sistema refrigerante se deben cumplir las siguientes
precauciones antes de realizar los trabajos en el sistema.
2. Procedimiento de trabajo
El trabajo se debe realizar bajo un procedimiento controlado de manera que minimice el
riesgo de los gases inflamables o vapores que pueden generarse durante los trabajos.
3. Zona general de trabajo
Todo el personal de mantenimiento y todos los que trabajen en esta zona deben conocer el
procedimiento de trabajo establecido. Se deben evitar los trabajos en espacios reducidos. La
zona alrededor del espacio de trabajo debe estar seccionada. Asegúrese de que las
condiciones en la zona son seguras y controle el material inflamable.
4. Compruebe si hay refrigerante
La zona se debe comprobar con un detector apropiado para refrigerante antes y durante
el funcionamiento, para asegurar que no hay riesgos de incendios.
Asegúrese de que el equipo de detección usado es compatible con refrigerantes
inflamables, p.ej. sin chispas, está bien sellado y es seguro.
5. Presencia de extintor de incendios
Si se realizan trabajos en el equipo de refrigeración o sus piezas, debe haber un equipo de
extinción de incendios disponible. Tenga a manos un extintor de polvo de CO2 junto al área de
carga.
6. Sin fuentes de ignición
Ninguna persona que realice trabajos con refrigerantes inflamables en el sistema de
refrigeración debe usar ningún tipo de fuente de ignición que puede tener riesgo de incendios o
explosión. Todas las fuentes de ignición posibles, incluyendo fumar cigarrillos se deben realizar
a una distancia prudente del sitio de instalación, reparación, extracción y desecho del equipo,
mientras éste contenga el refrigerante inflamable que podría salir. Asegúrese de que antes de
comenzar los trabajos, se ha supervisado el área alrededor del equipo para evitar los riesgos de
incendios.
Debe haber carteles de "No fumar".
7. Área ventilada
Asegúrese de que el área es abierta y bien ventilada antes de comenzar los trabajos en el
sistema de refrigerante o cualquier otro. Se debe contar siempre con buena ventilación
mientras se realiza el trabajo. La ventilación debe dispersar de manera segura cualquier fuga
de refrigerante y preferentemente sacar el gas de la habitación hacia el exterior.
8. Comprobaciones al equipo de refrigeración
Si se cambian componentes eléctricos, deben ser solo los especificados para esa función.
Siempre se deben cumplir las guías de mantenimiento y servicio del fabricante.
Si tiene dudas, consulte el departamento técnico del fabricante para obtener asistencia.
Se deben realizar las siguientes comprobaciones a los equipos con refrigerantes inflamables:

33
 
z La cantidad
 de carga es según
 el tamaño del compartimento dentro del cual se
instalan las piezas.
z El ventilador y las salidas están funcionando bien y no están obstruidas.
z Si se usa un circuito indirecto de refrigerante, el circuito secundario se debe
comprobar en búsqueda de refrigerante. Las etiquetas del equipo tienen que seguir
siendo visibles y legibles.
z Las etiquetas ilegibles se deben corregir.
z La tubería de refrigerante o los componentes se deben instalar en una posición
donde no queden expuestos a ninguna sustancia que pueda dañar los
componentes que contengan refrigerante, a menos que los componentes están
hechos de materiales resistentes a la corrosión o estén protegidos a tal efecto.

9. Comprobaciones de los dispositivos eléctricos


La reparación y el mantenimiento de los componentes eléctricos deben incluir comprobaciones
de seguridad y verificaciones de componentes. Si existen averías que puedan comprometer la
seguridad, no se debe conectar ningún suministro eléctrico al circuito hasta que se repare la
falla. Si no se puede reparar el equipo inmediatamente y tiene que seguir funcionando, se
puede usar una solución temporal apropiada. Se debe informar de la avería al propietario
de manera que todas las partes estén informadas.
Las comprobaciones previas de seguridad deben incluir:
z Los condensadores están descargados: esto se debe realizar de una manera segura para
evitar el riesgo de chispas.
z Cerciórese de que no hay ni componentes eléctricos ni cables que queden expuestos
durante la carga de refrigerante, recuperación o purga del sistema.
z Asegúrese de que hay continuidad en la conexión a tierra.


10. Reparación a los componentes sellados


10.1 En la reparación de los componentes sellados, todas las conexiones del equipo anterior
se deben desconectar antes de quitar las tapas o cubiertas. Si es absolutamente
necesario tener un suministro eléctrico durante el mantenimiento, se debe colocar
permanentemente un detector de fugas en el punto más riesgoso para evitar una
potencial situación de peligro.
10.2 Se debe prestar una atención especial a estos aspectos para asegurar un trabajo seguro
con los componentes eléctricos, la carcasa no se debe afectar hasta el punto de dañar la
protección. Esto incluye daños a los cables, exceso de conexiones, terminales fuera de
las especificaciones, daños a las juntas, mala instalación de componentes, etc.
Asegúrese de que la unidad quede bien montada.
Asegúrese de que las juntas o material de sellado no estén desgastados al punto
de que no cumplan su función de prevenir la entrada de elementos inflamables. Las
piezas de sustitución deben cumplir siempre con las especificaciones del fabricante.
 
NOTA: El uso de silicona para sellar puede obstaculizar la efectividad de algunos equipos
detectores de fugas. Normalmente los componentes seguros no tienen que estar aislados
antes de trabajar en ellos.



34
11. Reparación de componentes seguros
No aplique

ningún inductor permanente

o cargas de capacitancia al circuito sin asegurar que esto
no excederá el voltaje ni la corriente permisible para el equipo en uso. Estos componentes
seguros son los únicos con los que se puede trabajar en una ambiente de gases inflamables.
El comprobador debe tener el rango correcto.
La sustitución de componentes solo se debe hacer con las piezas especificadas por el
fabricante. Si usa otros componentes corre el riesgo de incendio del refrigerante en la
atmósfera a partir de una fuga.
12. Cables
En los cables comprobar: el desgaste, la corrosión, la presión excesiva, la vibración, los
bordes afilados o cualquier otro daño que puedan tener. También se debe tener en
cuenta los efectos del tiempo o de la vibración continuada de fuentes como compresores o
ventiladores.
13. Detección de refrigerantes inflamables
Bajo ninguna circunstancia se deben usar las fuentes de ignición como detectores de fugas
de refrigerante. No se deben usar llamas de haluros (o cualquier otro detector de fuego).
14. Métodos de detección de fugas
Los siguientes métodos de detección de fugas están aceptados para los sistemas que contienen
refrigerantes inflamables. Los detectores de fugas electrónicos son aptos para refrigerantes
inflamables, habrá que ajustar la sensibilidad y recalibrar los aparatos. (Los equipos de detección
se deben calibrar en un área sin refrigerante). Asegúrese de que el detector no es una fuente
potencial de ignición y de que sea compatible con el refrigerante usado. El detector de fugas se
debe ajustar a un porcentaje de LFL del refrigerante y se debe calibrar al refrigerante empleado y
habrá que confirmar el porcentaje apropiado del gas (25% máximo). La detección de fugas
mediante fluidos es compatible para el uso con la mayor parte de refrigerantes, se debe evitar el
uso de los detergentes con cloro, puede reaccionar con el refrigerante y corroer la tubería de
cobre.
Si se sospecha que hay fuga, se deben eliminar o apagar todas las fuentes de ignición. Si se
encuentra una fuga de refrigerante que necesita soldadura, se debe purgar todo el refrigerante
del sistema o aislarlo (mediante el cierre de las válvulas) en un lugar del sistema alejado de la
fuga. El nitrógeno sin oxígeno (OFN) se debe purgar a través del sistema tanto antes como
durante el proceso de soldadura.


15. Extracción y evacuación del gas


Siempre antes de comenzar los trabajos en el circuito de refrigerante para reparaciones o
cualquier otro propósito de procedimiento convencional debe seguir estos procedimientos.
Es importante que se sigan las mejores prácticas para evitar los riesgos de incendios.
Los procedimientos son:
z Extraer el refrigerante;
z Purgar el circuito con gas inerte,
z Evacuar;
z Purgar nuevamente con gas inerte;
z Abrir el circuito al cortar o soldar.
La carga de refrigerante se debe recuperar dentro de los cilindros de recuperación
apropiados. El sistema se debe enjuagar con OFN para que la unidad sea segura. Este
proceso puede necesitar que se repita muchas veces. No se debe usar aire comprimido
para esta actividad.
La limpieza de las tuberías se debe realizar entrando al sistema de vacío OFN y seguir llenando
hasta lograr la presión de trabajo, la ventilación y después deshacer el vacío. Este proceso se
debe repetir hasta que no quede refrigerante en el sistema.

35
Cuando la carga OFN se usa, se debe ventilar el sistema para que baje a la presión
atmosférica y de esta manera permitir que funcione. Esta operación es vital cuando se va a
 
soldar.
Asegúrese de que la salida de la bomba de vacío no está cerrada a fuentes de ignición y de
que hay ventilación.
16. Procedimientos de carga
Además de los procedimientos de carga convencional, se deben seguir los requisitos
siguientes:
z Asegúrese de que no haya contaminación de refrigerantes diferentes al usar equipos
de carga. Tanto las mangueras como las tuberías deben ser tan cortas como sea
posible para minimizar la cantidad de refrigerante que contienen.
z Los cilindros deben mantenerse siempre de pie.
z Asegúrese de que el sistema de refrigeración está conectado a tierra antes de la carga
de refrigerante.
z Realice una marca en el sistema cuando haya terminado la carga (si no existe).
z Se deben tomar todas las medidas de seguridad para no sobrecargar el sistema de
refrigerante.
z Antes de la recarga del sistema se debe comprobar la presión con OFN. El sistema se
debe comprobar en busca de fugas para completar la carga pero antes de la instalación.
Se debe realizar un prueba de fugas antes abandonar la habitación donde se encuentra el
equipo.

17. Desmontaje
Antes de realizar este procedimiento, es esencial que el técnico esté familiarizado completamente
con el equipo y todos sus detalles. Se recomienda el uso de las buenas prácticas para una
recuperación segura de todos los refrigerantes. Antes de llevar a cabo las tareas se deben tomar
muestras de aceite y refrigerante.

En caso de que haga falta analizarlos antes de volverlos a usar o realizar una reclamación.
Es esencial que esté disponible la corriente antes de comenzar los preparativos.
a) Familiarícese con el equipo y su funcionamiento.
b) Aísle el sistema eléctricamente.
c) Antes de comenzar el procedimiento asegúrese de que:
z La manipulación mecánica del equipo está disponible, si es necesario, para el manejo de
cilindros del refrigerante.
z Todo el equipamiento para la protección física está disponible y debe usarse correctamente.
z El proceso de recuperación se supervisa en todo momento por una persona competente.
z El equipo de recuperación y los cilindros están homologados y cumplen la normativa.
d) Purgue con una bomba el sistema refrigerante si es posible.
e) Si el vacío no es posible, aplicar un separador hidráulico para que el refrigerante pueda
extraerse desde varias partes del sistema.
f) Asegúrese de que el cilindro está situado en las escalas antes de que se efectúe la
recuperación.
g) Encienda la máquina de recuperación y hágala funcionar según las instrucciones del fabricante.
h) No rellene los cilindros en exceso. (No supere el 80% del volumen del líquido de carga).
i) No exceda la presión de trabajo máxima del cilindro, ni siquiera temporalmente.
j) Cuando se han llenado los cilindros correctamente y se ha completado el proceso,
asegúrese de que los cilindros y el equipamiento se sacan de su lugar oportunamente y
que todas las válvulas de aislamiento están cerradas.
k) El refrigerante recuperado no se debe cargar en otro sistema de recuperación a menos
que se haya limpiado y comprobado.
36
18. Etiquetado
El equipo
 se debe etiquetar mencionando
 que está reparado y sin refrigerante. La etiqueta
debe tener la fecha y la firma. Asegúrese de que hay etiquetas en el equipo con la
actualización del estado del refrigerante inflamable.
19. Recuperación
Se recomienda usar las buenas prácticas recomendadas cuando extraiga el refrigerante
ya sea por mantenimiento o instalación.
Al transferir el refrigerante a los cilindros, asegúrese de que solo se emplean los cilindros
de recuperación apropiados del refrigerante. Asegúrese de que está disponible la
cantidad correcta de cilindros para contener la carga de todo el sistema. Todos los
cilindros que se usarán están diseñados para recuperar el refrigerante y etiquetados para ese
refrigerante (p. ej. cilindros especiales para la recuperación del refrigerante). Los cilindros se
deben completar con válvula de alivio de presión y estar asociados con válvulas de cierre en
buen estado correcto.
Los cilindros de recuperación vacíos se vaciarán completamente y, si es posible, se
enfriarán antes de la recuperación.
El equipo de recuperación debe estar en buen estado con un conjunto de instrucciones con
respecto al equipo que está disponible y debe ser compatible con la recuperación de
refrigerantes inflamables. Además, debe estar disponible un conjunto de básculas en buen
estado.
Las mangueras deben estar completas con acopladores sin fugas y en buenas
condiciones. Antes de usar el recuperador, compruebe que está en buen estado, que se
le ha dado un buen mantenimiento y que los componentes eléctricos asociados están
sellados para evitar incendios en caso de la salida del refrigerante. Consulte al fabricante
en caso de dudas.
El refrigerante recuperado debe retornar al proveedor de refrigerante en el cilindro de
recuperación correcto y se debe actualizar la nota de trasferencia de repuesto
correspondiente. No mezcle los refrigerantes en las unidades de recuperación y sobre
todo en los cilindros.
Si hay que sacar los compresores o sus aceites, asegúrese de que se han evacuado a
un nivel aceptable para asegurarse de que el refrigerante inflamable no está dentro del
lubricante. El proceso de evacuación se debe realizar antes de devolver el compresor a los
proveedores. Solo el calentador eléctrico al cuerpo del compresor se debe emplear para
acelerar este proceso. Cuando se drena el aceite del sistema se debe hacer de manera
segura.
20. Transporte, etiquetado y unidades de almacenaje
1. Transporte el equipo que contiene refrigerantes inflamables según indican las regulaciones
vigentes.
2. Pegue etiquetas en el equipo con símbolos acorde a las regulaciones locales.
3. Deseche el equipo con gases refrigerantes como lo indican las normativas nacionales.
4. Almacenaje de equipos/accesorios
El almacenaje debe ser acorde a las instrucciones del fabricante.
5. Almacenaje del paquete (no vendido)
Las cajas que contienen las unidades deben estar protegidas para evitar daños mecánicos
a las unidades que podrían provocar fugas del refrigerante.
El número máximo de piezas acopladas permitidas en el mismo almacén se establecerá
según las regulaciones locales.

37
EN Installation and Owner's Manual

 
CONTENT
SAFETY PRECAUTIONS ............................................................................................ 39
INSTALLATION MANUAL ........................................................................................... 43
Indoor unit installation .................................................................................................. 43
Outdoor unit installation ............................................................................................... 44
Refrigerant pipe connection ......................................................................................... 46
Electrical installation .................................................................................................... 48
Drain joint installation ................................................................................................... 41
Start up and performance testing ................................................................................. 41

OWNERS MANUAL ..................................................................................................... 50


Description and operating instructions ......................................................................... 50
Care and maintenance ................................................................................................. 54
Troubleshooting ........................................................................................................... 56
Disposal ....................................................................................................................... 57
REMOTE CONTROLLER ............................................................................................ 58
INFORMATION SERVICING ....................................................................................... 67

Caution: Risk of fire

$%&%
This Air Conditioner should be used for hosehold use.
This unit must be installed by a professional according RD 795/2010, RD 1027/2007 and RD 238/2013.
$&&'
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision
of the person competent in the use of the person competent in the use of flammable refrigerants.
The power supply must be SINGLE-PHASE (one phase (L) and one neutral (N)) with his grounded power (GND))
or THREE-PHASE (three phase (L1, L2, L3) and one neutral (N) with his grounded power (GND)) and his manual
switch. Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer.

&%
 the aesthetic and dimensional characteristics,
In line with the company's policy of continual product improvement,
technical data and accessories of this appliance may be changed without notice.

%%&%&
Read this manual carefully before installind or operating you new air conditioning unit. Make sure to save this
manual for future reference.

38
SAFETY PRECAUTIONS
Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain,
and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of
your unit.
Read Safety Precautions Before Installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.

Failure to observe a warning may result in death. The appliance must be installed in accordance with
national regulations.
WARNING

Failure to observe a caution may result in injury or equipment damage.

CAUTION

This symbol indicates that you must never perform the action indicated.

WARNING
1. Ask an authorized dealer to install this air conditioner. Inappropriate installation may cause water leakage,
electric shock, or fire.
2. The warranty will be voided if the unit is not installed by professionals.
3. If abnormal situation arises (like burning smell), turn ou the power supply and call your dealer for instructions
to avoid electric shock, fire or injury.
4. DO NOT let the indoor unit or the remote control get wet. It may cause electric shock or fire.
5. DO NOT insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan
may be rotating at high speeds.
6. DO NOT use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or
combustion.
7. The appliance shall be stored so as to prevent mechanical damage from occurring.
8. Compliance with national gas regulations shall be observed.
9. Carefully read the Safety Precautions before installation.
10. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed
air-conditioning units is highly recommended.
11. Only trained and certified technicians should install, repair and service this air conditioning unit.
12. Improper installation may result in electrical shock, short circuit, leaks, fire or other damage to the
equipment and personal property.
13. Strictly follow the installation instructions set forth in this manual.
14. Before you install the unit, consider strong winds, typhoons and earthquakes that might auect your
unit and locate it accordingly. Failure to do so could cause the equipment to fail.
15. This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be made by children without
supervision.
16. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
17. This appliance is not intended for use by persons(including children) with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
18. Children should be supervised to ensure that they do not play with the appliance..
(IEC Standard requirement)

39
 
WARNING
19. If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified
persons in order to avoid a hazard.
20. The appliance shall be installed in accordance with national wiring regulations.
21. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage current
that may exceed 10mA,the residual current device (RCD) having a rated residual operating current not
exceeding 30mA,and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
22. The appliance disconnection must be incorporated with an all-pole disconnection device in the fixed wiring in
accordance with the wiring rules.
23. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment specification.
24. Servicing shall only be performed as recommended by the equipment manufacturer.
25. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the
supervision of the person competent in the use of flammable refrigerants.
26. The appliance shall be stored so as to prevent mechanical damage from occurring.
27. Keep ventilation openings clear of obstruction.
28. Do not turn on the power until all work has been completed.
29. When moving or relocating the air conditioner, consult experienced service technicians for disconnection
and reinstallation of the unit
30. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed
air-conditioning units is highly recommended.
31. Removal of the plug has to be such that an operator can check from any of the points to which he has
access that the plug remains removed.
32. If this is not possible, due to the construction of the appliance or its installation, a disconnection with a
locking system in the isolated position shall be provided.

CLEANING AND MAINTENANCE WARNINGS


1. Turn ou the device and pull the plug before cleaning. Failure to do so can cause electrical shock.
2. Do not clean the air conditioner with excessive amounts of water.
3. Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause
deformation. Turn ou the device and pull the plug before cleaning. Failure to do so can cause electrical shock.

ELECTRICAL WARNINGS
1. Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer or
certified service agent.
2. Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can
cause fire or electric shock.
3. Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the
cord can damage it, which can lead to fire or electric shock.
4. Do not use an extension cord, manually extend the power cord, or connect other appliances to the same
outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient voltage can cause fire.

40
 
CAUTION
For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any combustible
materials.
Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible gas
accumulates around the unit, it may cause fire.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to
water can cause electrical components to short circuit.
1. The product must be properly grounded at the time of installation, or electrical shock may occur.
2. Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage
to your home and property.
3. DO NOT touch the air outlet while the swing flap is in motion. Fingers might get caught or the unit may break
down.
4. DO NOT inspect the unit by yourself. Ask an authorized dealer to perform the inspection.
5. To prevent product deterioration, do not use the air conditioner for preservation purposes (storage of food, plants,
animals, works of art, etc.).
6. DO NOT touch the evaporator coils inside the indoor unit. The evaporator coils are sharp and may cause injury.
7. DO NOT operate the air conditioner with wet hands. It may cause electric shock.
8. DO NOT place items that might be auected by moisture damage under the indoor unit.
9. Condensation can occur at a relative humidity of 80%.
10. DO NOT expose heat-producing appliances to cold air or place them under the indoor unit.
11. This may cause incomplete combustion or deformation of the unit due to the heat.
12. After long periods of usage, check the indoor unit to see if anything is damaged. If the indoor unit is damaged,
it may fall and cause injury.
13. If the air conditioner is used together with other heating devices, thoroughly ventilate the room to avoid oxygen
deficiency.
14. DO NOT climb onto or place objects on top of the outdoor unit.
15. DO NOT operate the air conditioner when using fumigant insecticides. The chemicals may become layered
with the unit and endanger those who are hypersensitive to chemicals.
16. DO NOT let children play with the air conditioner.
17. DO NOT operate the air conditioner in a wet room (e.g. bathroom or laundry room).
18. This can cause electrical shock and cause the product to deteriorate.

Cautions for using R32 refrigerant

1. Installation (Space)
- That the installation of pipe-work shall be kept to a minimum.
- That pipe-work shall be protected from physical damage.
- That compliance with national gas regulations shall be observed.
- That mechanical connections shall be accessible for maintenance purposes.
- In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
- When disposing of the product is used, be based on national regulations, properly processed.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as
specified for operation.
- Spaces where refrigerant pipes shall be compliance with national gas regulations.
2. Servicing
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall be carried out under the supervision of the person
competent in the use of flammable refrigerants.

41
Cautions for using R32 refrigerant
 
3. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
4. The appliance shall be stored in a room without continuously operating ignition sources (for example: open
flames,an operating gas appliance or an operating electric heater)
5. Do not pierce or burn.
6. Be aware that refrigerants may not contain an odour.
7. Be more careful that foreign matter(oil, water,etc) does not enter the piping. Also, when storing the piping,
securely seal the opening by pinching, taping, etc.
For indoor units, use R32 flareless joint assy only when connecting the indoor unit and connecting piping
(when connecting indoors). Use of pipes, flareless nut or flare nuts other than specified, may cause product
malfunction, burst piping, or injury due to high internal pressure of the refrigerant cycle caused by any inflow air.
8. Appliance shall be installed, operated and stored in a room with a floor area larger than X m² (Please see the
following form). The appliance shall not be installed in an unventilated space, if that space is smaller than X m²
(Please see the following form).

Amount of refrigerant Maximum installation Minimum room


Model (kBTU/h)
to be charged (kg) height (m) area (m²)

≤2,048 2,2m 4
≤30 ≤2,048 1,8m 4
≤2,048 0,6m 35
2,048-3,0 2,2m 4
36-42 2,048-3,0 1,8m 8
2,048-3,0 0,6m 80

Note about Fluorinated Gasses


1. This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the type of gas
and the amount, please refer to the relevant label on the unit itself.
2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
3. Product uninstallation and recycling must be performed by a certified technician.
4. For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2 equivalent or more,
but of less than 50 tonnes of CO2 equivalent, If the system has a leak- detection system installed, it must be
checked for leaks at least every 24 months.
5. When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.

Explanation of symbols displayed on the indoor unit or outdoor unit:

This symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is
WARNING
leaked and exposed to an external ignition source, there is a risk of fire.

CAUTION This symbol shows that the operation manual should be read carefully.

CAUTION
This symbol shows that a service personnel should be handling this equipment with
reference to the installation manual.
CAUTION

This symbol shows that information is available such as the operating manual or
CAUTION
installation manual.

42
INSTALLATION MANUAL

1.
 Indoor unit installation


Fit the installation plate


1) Fit the installation plate horizontally on structural parts of the wall with spaces
arround the installation plate.
2) If the wall is made of brick, concrete or like, drill five or eight 5mm diameter holes
in the wall. Insert Clip anchor for appropiates mounting screws.
Correct orientation of Mounting Plate

Drill a hole in the w all Wall


Outdoor
1. Determine hole positions according to left and right Indoor
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with φ65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.

5-7mm
4. Always take steps to protect the pipe when drilling metal
grid, metal plate or the like.

Mounting plate dimensions

Model 09 and 12 Model 18

Model 24

43
Connective pipe and drainage installation
 
1. Run the drain hose sloping downward. Do not put the end of
Do not block water flow by a rise.
Do not install the drain hose as drain hose into water.

illustrated in Fig.7.

2. When connecting extension drain hose,


insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.
Fig.8

Connective pipe installation Rear-right piping


Right-hand piping
1. For the left-hand and right-hand piping,
remove the pipe cover from the side
panel.
2. For the rear-right-hand and rear-left-hand
piping, install the piping as shown in Fig.10.
3. Fix the end of the connective pipe. (Refer
to Tightening Connection in REFRIGERANT
PIPING CONNECTION)

Rear-left piping
Piping and wrapping
Left-hand piping
Bundle the tubing, connecting cable, and drain
hose with tape securely, evenly as shown in
Fig.9 Fig.10
Fig.11.
Because the condensed water from rear of the
indoor unit is gathered in ponding box and is
piped out of room. Do not put anything else in
the box.
Caution
Connect the indoor unit first, then the
outdoor unit.
Do not allow the piping to let out from
the back of the indoor unit. Indoor unit Ponding box
Be careful not to let the drain hose slack.
Heat insulated both of the auxiliary piping. Connective Pipe room
Be sure that the drain hose is located at cable
the lowest side of the bundle. Locating .......
.. ...
Connective
at the upper side can cause drain pan ..
......
..
pipe
.
........
to overflow inside the unit. Wrapping belt
Never intercross nor intertwist the power Drain hose
wire with any other wiring.
Run the drain hose sloped downward to Fig.11
drain out the condensed water smoothly.

2. Outdoor unit installation


Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
Determine the air outlet direction where the discharged air is not blocked. In the case that
the installation place is exposed to strong wind such as a seaside, make sure the fan operating
properly by putting the unit lengthwise along the wall or using a dust or shield plates.
Specially in windy area, install the unit to prevent the admission of wind. If need suspending
installation, the installation bracket should accord with technique requirement in the
installation bracket diagram.
The installation wall should be solid brick, concrete or the same intensity construction, or
actions to reinforce, damping supporting should be taken. The connection between bracket and
wall, bracket and the air conditioner should be firm, stable and reliable.
Be sure there is no obstacle which block radiating air.

44
Dimensions
W1


B D

Unit: mm

     
      
      
    

Space for installation and maintenance


> 60 cm

> 30 cm
cm > 30

0 cm
> 20

> 60
cm

45
3. Refrigerant
 pipe connection

Before installing, make sure that the height difference, the length of refrigerant pipe and number of bends
between indoor and outdoor units, meet the following specifications.

Max. lenght:
Max. height difference:
AM2 AM3 AM4 / AM5
UNIT (2x1) (3x1) (4x1 / 5x1) Outdoor unit Indoor unit
Max. Length for all rooms (m) 40 60 80
Indoor unit
Max. Leng th for one indoor unit (m) 25 30 35
10m
OU higher than IU 15 *(1) 15 *(1) 15 *(1)
Max. height different between
indoor and outdoor unit (m)
OU lower than IU 15 15 15 5m

Max. height different between indoor units (m) 10 10 10


10m
Note: If the outdoor unit is installed above the indoor units and the sum
of all the tanks is more than 7m, an oil trap must be installed in the Indoor unit

gas pipe every 3 meters.

Additional charge

UNIT AM2 (2x1) AM3 (3x1) AM4 (4x1) AM5 (5x1)

Charged until 15m 22,5m 30m 37,5m

Additional
charge 20 x (Total length - 15) 20 x (Total length - 22,5) 20 x (Total length - 30) 20 x (Total length- 37,5)
R32 (g)

1. Flaring work
Main cause for refrigerant leakage 。
90 Oblique Roughness Burr
is due to defect in the flaring work.
Carry out correct flaring work
using the following procedure:
A: Cut the pipes and the cable. Fig.54
1. Use the piping kit accessory or pipes
purchased locally. Pipe

2. Measure the distance between the indoor Reamer

and the outdoor unit.


3. Cut the pipes a little longer than the Point down
measured distance.
4. Cut the cable 1.5m longer than the pipe
length. Fig.55

B: Burr removal Flare nut


1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing. Copper tube
C: Putting nut on
Remove flare nuts attached to indoor and Fig.56
outdoor unit, then put them on pipe/tube
having completed burr removal.(not possible
to put them on after flaring work)

46
D: Flaring work Handle

"A"
 Firmly hold copper pipe in a die in the Bar Bar
dimension shown in the table below. Yoke

Outer diam. A(mm) Cone


(mm) Max. Min.
Copper pipe
6.35 1.3 0.7
Clamp handle
9.53 1.6 1.0 Red arrow mark
12.7 1.8 1.0
Fig.57
Tightening connection
Align the center of the pipes.
Sufficiently tighten the flare
Indoor unit tubing Flare nut Pipings
nut with fingers, and then tighten
it with a spanner and torque wrench
as shown in Fig.58 & 59 Fig.58

Outer Tightening Additional tightening


diam. torque(N.cm) torque(N.cm)
1500 1600
6.35 (153kgf.cm) (163kgf.cm)
2500 2600
9.52 (255kgf.cm) (265kgf.cm)
3500 3600
12.7 (357kgf.cm) (367kgf.cm)
Caution
Excessive torque can break nut
depending on installation conditions. Fig.59

Air purging
Air and moisture in the refrigerant system have undesirable effects as indicated below:
● Pressure in the system rises.
● Operating current rises.
● Cooling or heating efficiency drops.
● Moisture in the refrigerant circuit may freeze and block capillary tubing.
● Water may lead to corrosion of parts in the refrigeration system.
Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tested
and evacuated to remove any noncondensables and moisture from the system.
Air purging w ith vacuum pump
● Preparation
Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units
have been properly connected and all wiring for the test run has been completed. Remove
the service valve caps from both the gas and the liquid side on the outdoor unit. Note that
both the liquid and the gas side service valves on the outdoor unit are kept closed at this
stage.
● Pipe length and refrigerant amount:
Refrigerant
Outdoor Indoor
When relocate the unit to another place, unit
unit A Gas side
perform evacuation using vacuum pump. C

Make sure the refrigerant added into the air Liquid side D

conditioner is liquid form in any case. B


Packed valve Half union Fig.65
Caution in handling the packed valve
Flare nut
Open the valve stem until it hits against the
stopper. Do not try to open it further.
Securely tighten the valve stem cap with a Stopper
spanner or the like. Cap
Valve stem cap tightening torque (See
Tightening torque table in previous page ). Valve body
Valve stem Fig.66

47
4.
 Electrical installation

Safety standards
- The supply voltage must be within a range of 90% to 110% of nominal value.
- The thermal circuit breaker and breaker should be 1.5 times the nominal consumption.
- All installation and wiring must comply with local and national average and the installation should
be performed by qualified personnel.
- The minimum section of wiring should be as follows according to consumption.

Connect the cable to the outdoor unit


1. Remove the electrical control board cover
from the outdoor unit by loosening the screw
as shown in figure.
2. Connect the connective cables to the
terminals as identified with their respective
matched numbers on the terminal block of Screw
indoor and outdoor units.
3. Secure the cable onto the control board with Cover
the cord clamp.
4. To prevent the ingress of water, from a loop
of the connective cable as illustrated in the
installation diagram of indoor and outdoor
units.
5. Insulate unused cords (conductors) with
PVC-tape.Process them so they do not
touch any electrical or metal parts.

   Pow er 


Wire 
Differential sw itch
AM2 / AM3       
AM4 / AM5    

Interconnection wiring between the outdoor unit and indoor units


For the interconnection between the outdoor unit and each indoor unit, use 3x1,5mm + T cable.

Outdoor unit
Terminal block
    
              

230V - 50Hz

Don't connect

           
Wall mounted IDU (AMW) Others IDU Cassette or Duct

Indoor unit
Terminal block
Note:
The wall mounted indoor unit has terminal Lo, that should not be connected.

48
 
5. Drain joint installation

Fit the seal into the drain joint, then insert the
drain joint into the base pan hole of outdoor unit,

rotate 90 to securely assemble them.
Connecting the drain joint with an extension drain Drain joint Base pan hole of
Seal
hose (Locally purchased), in case of the water outdoor unit
draining off the outdoor unit during the heating
mode. Seal
Drain pipe
NOTE: The drain joint differ from appliance (1) (2)
to appliance.

6. Start up and performance testing

Prior checks
- Measure the voltage supply and make sure it is within the specified range.
- Testing must be performed in all modes of operation.
- To operate in cool mode, press the ON/OFF button of the remote controller to place the unit in
cooling mode and select a temperature below room temperature.
- To operate in heat mode, press the ON/OFF button of the remote controller to place the unit in
heating mode and select a temperature above room temperature.
- You can also check the manual button. This is used when you do not have the remote controller and
and is located under the front panel.

49
OWNER'S MANUAL

1.
 Description and operating
 instructions

Parts
a) Wall mounted
Indoor unit
Unit C
1. Front panel
2. Top air intake
3. Air filter(Inside)
4. Air outlet
5. Horizontal air flow louver
6. Vertical air flow louver(Internal)
7. Display panel Unit B
8. LED display window
9. Remote controller
10. Manual control button(Behind the front panel)
   
Outdoor unit
11. Refrigerant connecting pipe, drain hose and Unit A
electric wiring
12. Stop valve
13. Air outlet  

 
 
 



 

#####

!

 


  
 " 
###### 

####
#

Display

*OPUIFSNPEFT UIFVOJUXJMMEJTQMBZZPVSUFNQFSBUVSFTFUUJOH
*O'BONPEF UIFVOJUXJMMEJTQMBZUIFSPPNUFNQFSBUVSF

50
 
b) Duct c) Cassette

Unit E
Unit E

Unit D
Unit D

Unit C Unit C

Unit B Unit B

Unit A
Unit A




Indoor unit
Indoor unit
1. Drain pump (drain water from indoor unit)
1. Air outlet
2. Drain hose
2. Air inlet
3. Air outlet
3. Air filter
4. Air inlet
4. Electric control cabinet
5. Air-in grill
5. Wire controller
6. Display panel
Outdoor unit
7. Remote controller
6. Drain hose, refrigerant connecting pipe Outdoor unit
7. Connective cable 8. Refrigerant connecting pipe
8. Stop valve 9. Connective cable
9. Fan hood 10. Stop valve
11. Fan hood
51
Operating temperature

Mode Cooling operation Heating operation


Temperature
Room temperature > 18ºC < 32ºC
Outdoor temperature -15º ~ 52ºC -15º ~ 24ºC

Manual operation
Manual operation can be used temporarily in case you can not find the remote controller or
test running purpose or maintenance necessary.

NOTE: The unit must be turned off before


operating the manual control button. If the
unit is operational, continue pressing the
manual control button until the unit is off.
1 Open and lift the front panel up will see the
manual control button(see Model A)
AUTO For some models, the manual control button is
located at the bottom of the unit(see Model B).
2 One press of the manual control button will
lead to the forced AUTO operation. If press
the button twice within five seconds, the unit
will operate under forced COOL operation.
3 Close the panel firmly to its original position.

52
How the air conditioner w orks

AUTO operation
When you set the air conditioner in AUTO mode,
it will automatically select cooling, heating(cooling
/heating models only), or fan only operation
depending on what temperature you have selected
and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set by
you.
If the AUTO mode is uncomfortable, you can
select desired conditions manually.

SLEEP operation
When you push SLEEP button on remote controller
during cooling, heating(cooling only type without),
or AUTO operation , the air conditioner will
automatically increase (cooling) or decrease
(heating) 1℃ per hour.
The set temperature will be steady 2 hours later.
And the air conditioner will be timer off in 7 hours.
The fan speed will be automatically controlled.
This feature can maintain the most comfortable
temperature and save more energy for you.
 - 7
 !I%56 !I356 H 
!56 %  3   +   

B - 7
 !356 !'56 H 
!56 %  3   +   

(  &- ,  8( 2( & - +

Airflow direction control

Adjust the air flow direction properly otherwise, it CAUTION


might cause discomfort or cause uneven room
Do not operate the air conditioner for long periods with
temperatures. the air flow direction set downward in cooling or
Adjust the horizontal louver using the remote dehumidifying mode. Otherwise, condensation may
controller. occur on the surface of the horizontal louver causing
Adjust the vertical louver manually. moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually unless it is
To set the vertical air flow(Up--Down) direction necessary. Always use the remote controller.
Perform this function while the unit is in operation. When the air conditioner is started immediately after it
Use the remote controller to adjust the air flow was stopped, the horizontal louver might not move for
approximately 10 seconds.
direction. The horizontal louver can be moved at
Open angle of the horizontal louver should not be set
a range for each press, or swing up and down
,, too small, as COOLING or HEATING performance may
automatically. Please refer to the REMOTE be impaired due to too restricted air flow area.
,,
CONTROLLER OPERATION MANUAL for details. Do not operate unit with horizontal louver in closed
To set the horizontal air flow direction (left - right) position.
Move the vertical louver manually to adjust the air flow When the air conditioner is connected to power (initial
in the direction you prefer. power), the horizontal louver may generate a sound for
IMPORTANT :Beforeadjustingtheverticallouvers,the 10 seconds, this is a normal operation.
supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the ,,
,,
REMOTE CONTROLLER OPERATION MANUAL
for details.

53
2.
 Care and maintenance

Cleaning the grille,case and remote controller
Turn the system off before cleaning. To clean, wipe
with a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Supply power must be disconnectd before
cleaning the indoor unit.

CAUTIONS
A cloth dampened with cold water may be used on
the indoor unit if it is very dirty. Then wipe it with a
dry cloth.
Do not use a chemically treated cloth or duster to
clean the unit.
Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause
the plastic surface to crack or deform.
Never use water hotter than 40 C to clean the front
panel, it could cause deformation of discoloration. Filter Handle

Cleaning the air filter


A clogged air filter reduces the cooling efficiency of
this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it
stops with a clicking sound.
2. Take hold of the handle of the air filter and lift it
up slightly to take it out from the filter holder,
then pull it downwards.
3. Remove the Active Carbon & Dust Filter from the

..
indoor unit.
Clean the it once two weeks.
Clean the it with a vacuum cleaner or water,
then dry it up in cool place.
4. Remove the Air Freshening Filter(Optional filter:
Air freshening filter
Plasma Dust collector/Silver Ion filter /Bio filter /
Vitamin C filter) from its support frame.
(The installation and removing method of the air
freshening filter is different depending on the models, 1

. see the pictures marked 1 and 2 on the left.


Clean the air freshening filter at least once a month, Air freshening
filter

. and replace it every 4-5 months.


Clean it with vacuum cleaner, then dry it in cool place.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the unit
taking care that the left and right edges line up
correctly and place filter into position.

54

Maintenance 
If you plan to idle the unit for a long time, perform the following:
1.Cl ean th e i nd oor unit and ai r filt er.
2.Select FAN only mode, let the indoor fan run for a while to dry the inside of the unit.
3.Disconnect the power supply and remove battery from the remote control.
4.Check components of the outdoor unit periodically. Contact a local dealer or a customer service centre
if the unit requires servicing.
Note: Before you clean the air conditioner, be sure to switch the unit off and disconnect the power
supply plug.

When the air conditioner is to be used again:


Use a dry cloth to wipe off the dust accumulated on rear air intake grille, in order to avoid the dust
blowing out from the indoor unit.
Check that the wiring is not broken off or disconnected.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.

Operation tips
The following events may occur during normal operation.
1. Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in
one of the following three situations and the set temperature has not been reached.
A) When heating has just starting.
B) Defrosting.
C) Low temperature heating.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost buildup on the outdoor unit.

2. A white mist coming out from the indoor unit


A white mist may generate due to a large temperature difference between air inlet and air outlet on
COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air conditioner
restarts in HEAT mode operation after defrosting.

3. Low noise of the air conditioner


You may hear a low hissing sound when the compressor is running or has just stopped running.
This sound is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just stopped running.
This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temper-
ature is changing.
A noise may be heard due to louver restoring to its original position when power is first turned on.

4. Dust is blown out from the indoor unit.


This is a normal condition when the air conditioner has not been used for a long time or during first
use of the unit.
5. Auto-restart function
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor
unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit
with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings
preserved by the memory function.

55
3. Troubleshooting
Stop the air conditioner immediately if one of the following faults occur. Disconnect the
power and contact the nearest customer service center.

If the E( 0,1.......) or P( 0, 1 .......) code appears on the LED(LCD)window, disconnect the


power and contact the service people.

Trouble Fuse blows frequently or circuit breaker trips frequently.


Other objects or water penetrate the air conditioner.
The remote controller won't work or works abnormally.
Other abnormal situations.

Malfunctions Cause What should be done?


Unit does not Power cut Wait for power to be restored.
start
Check that plug is securely in wall
Unit may have become unplugged.
receptacle.

Fuse may have blown. Replace the fuse.

Battery in Remote controller may have Replace the battery.


been exhausted.

The time you have set with timer is Wait or cancel timer setting.
incorrect.
Unit not cooling Inappropriate temperature Set temperature correctly. For detailed
or heating setting. method please refer to "Remote
(Cooling/ heating controller instruction" section.
models only)
room very well Air filter is blocked. Clean the air filter.
while air flowing Doors or Windows are open. Close the doors or windows.
out from the air
Air inlet or outlet of indoor or Clear obstructions away first, then
conditioner
outdoor unit has been blocked. restart the unit.

Compressor 3 minutes Wait.


protection has been activated.

If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model.

Notes: Do not attempt to repair the unit yourself.


Always consult an authorised service provider.

56
Error code list:
  ( ) " #  
 *!";$DD!"DEF$"$
 *!";$DD<3$%1!":$5"
 *!";$DD!":$D.$3EF$&!!
 *!";$DD*!3EF$"$
   1"$'!$#;D""$!DEF$"$
 1"$'!$#;D$!)#!!!$1G3D$"$
* ."'$3!$"
* *!";$DD*!3""$
* 1$&*1'$
* 1'$3!$"
* *!";$DD$'D!%!"
* !"'$3''&
* *!";$DD&$!!"D""$
* *!";$DD&H&!%;&!%'$
* 1"$'!$#;D$&1G!!$1G3D""$
* *!";$DD""$45.
* *!";$DD"'$!"
6 *!";$DD!$!%EF-"$
6 1"$'!$#;D;$'!!$1G3DEF$"$
6 *!";$DD$8"$$!"DEF$"$
6 *!";$DD%!$!"DEF$"$
6 '$;!"$'D!%
6 +;";$'D'$
6 +;"'$
6 *!"33";!)&!&
6 -H'"'"$'!$$''$3!"
+ 5&&!%!"&!%'$3$<1
+ 5&'"'$3'
+ 1!$3!$"
+ D!H!#''$3'
+ -.*!"3'<$&"
+ 1$&*13;!'$
+ 1$&*1D!;!'$
+ <#!'$3''"'$
+ 1";'$
+ -.!"3!"
+ 1!3!$"
+1 *11"<'$<#!'$
+< <#!'$35"<1*!1"<'$
+ D!H!'I$%'$3"<13!
+* 5"<1*!5"H3H'$
+6 -.'$35"<1*!
 15&H'"'$3DJD.!'D$
 '$D$%D!"$'D!%
 6$%D!"'$343$%!$5"
 6$%D!"'$$6!$%4
 -!$H3K$%'$
 6$%D":;$'D'$
 '$3:)+!'I343$%!

4. Disposal
 

When using this air conditioner in the European countries, the follow information must be
followed:
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste.


For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can be disposed of at
least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least free of charge.
C) The manufacture will take back the old appliance for disposal at least free of charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal dealers.

Wild disposal of waste in forests and landscapes endangers your health when hazardous substances
leak into the ground-water and find their way into the food chain.

57
 

REMOTE CONTROLLER
Please read this Owner's Manual carefully before operation.
Save this manual in a safe place for future reference.

58
SPECIFICATIONS 1

iFEEL

Model YKR-H

Rated Voltage 3.0 V (Dry batteries AAA x 2)


Signal Receiving 8m
Range
Environment -5ºC to 60ºC

NOTE:
Buttons design is based on typical model and might be slightly different from the actual one you purchased, the
actual shape shall prevail.
All the functions described are accomplished by the unit. If the unit has no this feature, there is no corresponding
operation happened when press the relative button on the remote controller.
,, ,,
When there are wide differences between Remote controller Illustration and "Owner's manual" on
on function description, the description of "Owner's manual" shall prevail.

59
OPERATION OF BUTTONS 2
Note:
The remote controller
display all symbols
during power-on and
only those
8 1 corresponding to
9 2 current operation the
rest of the time.
10 3
11 4
iFEEL
12 5
13
14 6

15 7

1. ON/OFF
* Press this button to turn on/off the unit.
* This will clear the existing timer and SLEEP settings.

2.
* Press this button to set the temperature display to Fahrenheit,
which is displayed by default in Celsius. The “℃” will not be
displayed on the LCD.
* Press this button again to restore the temperature display
to Celsius.
Note: Temperature display in Fahrenheit is not available for some
models. When temperature is displayed in Fahrenheit on the
remote controller, it might be in Celsius on the unit, the function
and operation of which will not be affected.

60
3. SPEED
* Press this button, you can select the fan speed as follows:
Low Mid High Auto
Note: AUTO air speed is not available in FAN mode.

4. DISPLAY
* Press this button to turn on/off the display. This is for the
convenience of users who are unconformable sleeping with
the backlight on.
5. iFEEL
* Press this button to set the temperature display on the
remote controller to ambient temperature and press this
button again to set it to preset temperature.
6. TIMER
* With the unit ON, press this button to set OFF timer or with
it OFF to set ON timer.
* Press this button once, a “ON(OFF)” will flash. Press “ ” or
“ ”to set the number of hours in which the unit will be turned
ON/OFF, with an interval of 0.5 hour if less than 10 hours, or
1 hour if longer than 10 hours , and a range of 0.5-24 hours.
* Press it again to confirm the setting, the “ON (OFF)” will
stop flashing.
* If the timer button is not pressed longer than 10 seconds after
the “ON (OFF)” start flashing, the timer setting will be exited.
* If a timer setting is confirmed, pressing this button again will
cancel it.
Note: When a ON timer is set, all function buttons (except SLEEP,
DISPLAY and iFEEL can't be set ) are valid and when the ON time
set is up, the unit will operate as preset.

61
7. HEALTH / iCLEAN
This function performs a self cleaning the indoor unit. When the 'iClean' function is
activated, the unit operates initially mode cooling fan at low speed during this period
condensing water entrains the powder battery. then the unit switches to heating
mode the fan at low speed, to dry the battery inside the unit. Finally the drive
switches to cooling to finish completely dry.
This button also serves to remove the reminder cleaning air filter, code
'CL' which is activated when the machine reaches the cumulative
operating 360h. Press 10 times the 'HEALTH' button to remove the counter.
To turn off the meter, press the 'HEALTH' button 5 times.

8. or
* Each time the “ ” is pressed, the temperature setting will
increase by 1℃ and each time the “ ” is pressed, it will
decrease by 1℃.
* The temperature setting ranges from 16℃ (60℉)~32℃(90℉).
Note: The temperature cannot be set in AUTO or FAN mode, thus
these two buttons are not functional.

9. TURBO
* Press this button only in COOL or HEAT mode to set TURBO
on or off to speedy the cooling or heating.
* When TURBO is on, the air speed is HIGH.
* When TURBO is off, the air speed will restore to previous
status.
10. MODE
* Press this button, you can select the running mode as follows:
AUTO COOL DRY HEAT FAN
Note: HEAT mode is not available for cool only units.

62
11. SLEEP
* Press this button to enter SLEEP mode, which the unit will
exit after 10 hours of continuous operation and restore to the
previous status.
Note:The SLEEP function cannot be activated in FAN mode.

12. SWING
* Press this button to activate up/down swing and press it again
to fix the swing position.
13. SWING This button has no function.

63
14 .Anti-F
* The Anti-F functions when the unit is turned off with the remote
controller in COOL, DRY or AUTO mode. It will operate in HEAT
mode (FAN mode for cool only units), with the internal fan
running with weak flow for 3 minute before stop, to remove the
moisture within the evaporator so as to prevent it from giving
off bad smell from mold.
* This function is not set in the factory. You may set it or cancel it
any time you want as follows: With both the unit and the remote
controller OFF, point the remote controller at the unit and press
“Anti-F” button once, the buzzer will sound 5 times after 5 times,
indicating this function is set. Once set, this function will remain
valid except when the unit is power off or until it is canceled.
* To cancel Anti-F:
1. Power off the unit.
2. With both the unit and the remote controller OFF, point the
remote controller at the unit and press this button once, the
buzzer will sound 3 times after 5 times, indicating this function
is canceled.
Note:
* With Anti-F activated, it is advised not to turn ON the unit
again before it is fully OFF.
* Anti-F function will be invalid when OFF timer is set.

15. This button has no function.

64
OPERATION 3

65
ATTENTION 4
1.Aim the remote con troller toward s the receiver on the air-
conditio ner.
2.The remote controller s hould be within 8 meters away
from the receiver.
3.No obstacle s be tween the re mo te controller and receiver.
4.Do not drop or throw the remote con trolle r.
5.Do not put the remote co ntro ller under the forceful
sunrays or h eating facilities and othe r heating sources.
6.Us e two 7# batteries, do not use the electric batteries.
7.Take the batteries out o f remote controller be fore stop its
using for lon g.
8.When the noise of transmitting signal canÿ t be heard
ind oor u nit or the transmission symbol on the display
screen doe snÿ t flare, ba tterie s need be re placed.
9.If reset phenomenon occurs on pressing the button of the
remote con trolle r, the electric quantity is deficient and
new ba tteries n eed to be sub stituted.
10.The w aste battery sho uld be disposed properly.

CHANGING THE BATTERIES 5

66
 

INFORMATION SERVICING

Please note all service information before performing any installation,


maintenance or handling of this R-32 gas air conditioner.

67
 
1. Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary
to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the system.
2. Work procedure
Works shall be undertaken under a controlled procedure so as to minimise the risk of a
flammable gas or vapour being present while the work is being performed.
3. General work area
All mintenance staff and others working in the local area shall be instructed on the nature of work
being carried out. work in confined sapces shall be avoided. The area around the work space shall
be sectioned off. Ensure that the conditions within the area have been made safe by control of
flammable material.
4. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work,
to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak
detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking,
adequately sealed or intrinsically safe.
5. Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate
fire extinguishing equipment shall be available to hand. Have a dry power or CO2 fire extinguisher
adjacent to the charging area.
6. No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe
work that contains or has contained flammable refrigerant shall use any sources of ignition in such a
manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette
smoking, should be kept sufficiently far away from the site of installation, repairing, removing and
disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior
to work taking place, the area around the equipment is,,to be surveyed to make sure that there are
,,
no flammable hazards or ignition risks. NO SMOKING signs shall be displayed.
7. Ventilated area
Ensure that the area is in the open or that it it adequately ventilated before breaking into the system
or conducting any hot work. A degree of ventilation shall continue during the period that the work is
carried out. The ventilation should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.

8. Checks to the refrigeration equipment


Where electrical components are being changed, they shall be fit for the purpose and to the correct
,
specification. At all times the manufacturer s maintenance and service guidelines shall be followed.
,
If in doubt consult the manufacturer s technical department for assistance. The following checks shall
be applied to installations using flammable refrigerants:

68
 
z the charge size is in accordance with the room size within which the refrigerant containing
parts are installed;
z the ventilation machinery and outlets are operating adequately and are not obstructed;
z if an indirect refrigerating circuit is being used, the secondary circuits shall be checked
for the presence of refrigerant; marking to the equipment continues to be visible and
legible.
z marking and signs that are illegible shall be corrected;
z refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode refrigerant containing components, unless
z the components are constructed of materials which are inherently resistant to being
z corroded or are suitably protected against being so corroded.
9. Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and
component inspection procedures. If a fault exists that could compromise safety, then no
electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue operation, and adequate
temporary solution shall be used. This shall be reported to the owner of the equipment so all
parties are advised.
Initial safety checks shall include:
z that capacitors are discharged: this shall be done in a safe manner to avoid possibility of
sparking
z that there no live electrical components and wiring are exposed while charging, recovering
or purging the system;
z that there is continuity of earth bonding.

10. Repairs to sealed components


10.1 During repairs to sealed components, all electrical supplies shall be disconnected from the
equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely
necessary to have an electrical supply to equipment during servicing, then a permanently
operating form of leak detection shall be located at the most critical point to warn of a
potentially hazardous situation.
10.2 Particular attention shall be paid to the following to ensure that by working on electrical
components, the casing is not altered in such a way that the level of protection is affected.
This shall include damage to cables, excessive number of connections, terminals not made
to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve
the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall
,
be in accordance with the manufacturer s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection
equipment. Instrinsically safe components do not have to be isolated prior to working on them.

69
11. Repair to intrinsically safe components
 
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring
that this will not exceed the permissible voltage and current permitted for the equipment in
use. Intrinscially safe components are the only types that can be worked on while live in the
presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
Replace components only with parts specified by the manufacturer. Other parts may result
in the ignition of refrigerant in the atmosphere from a leak.
12. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp
edges or any other adverse environmental effects. The check shall also take into account the
effects of aging or continual vibration from sources such as compressors or fans.
13. Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or
detection of refrigerant leaks. A halide torch(or any other detector using a naked flame)
shall not be used.
14. Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable
refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the
sensitivity may not be adequate, or may need re-calibration.(Detection equipment shall be
calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition
and is suitable for the refrigerant. Leak detection equipment shall be set at a percentage of the
LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate
percentage of gas (25% maximum) is confirmed. Leak detection fluids are suitable for use with
most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine
may react with the refrigerant and corrode the copper pipe-work.
If a leak is suspected ,all naked flames shall be removed or extinguished. If a leakage of refrigernat
is found which requires brazing, all of the refrigerant shall be recovered from the system, or
isolated(by means of shut off valves) in a part of the system remote from the leak . Oxygen free
nitrogen(OFN) shall then be purged through the system both before and during the brazing process.

15. Removal and evacuation


When breaking into the refrigerant circuit to make repairs of for any other purpose
conventional procedures shall be used, However, it is important that best practice is followed
since flammability is a consideration. The following procedure shall be adhered to:
z remove refrigerant;
z purge the circuit with inert gas;
z evacuate;
z purge again with inert gas;
z open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be
flushed with OFN to render the unit safe. This process may need to be repeated several times.
Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to
fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down
to a vacuum. This process shall be repeated until no refrigerant is within the system.

70
When the  final OFN charge is used,
 the system shall be vented down to atmospheric pressure
to enable work to take place. This operation is absolutely vital if brazing operations on the
pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not closed to any ignition sources and there
is ventilation available.
16. Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed:
z Ensure that contamination of different refrigerants does not occur when using charging
equipment. Hoses or lines shall be as short as possible to minimize the amount of
refrigerant contained in them.
z Cylinders shall be kept upright.
z Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
z Label the system when charging is complete(if not already).
z Extreme care shall be taken not to overfill the refrigeration system.
z Prior to recharging the system it shall be pressure tested with OFN. The system shall be
leak tested on completion of charging but prior to commissioning. A follow up leak test
shall be carried out prior to leaving the site.

17. Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar
with the equipment and all its detail. It is recommended good practice that all refrigerants
are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall
be taken.

In case analysis is required prior to re-use of reclaimed refrigerant. It is essential that


electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically
c) Before attempting the procedure ensure that:
z mechanical handling equipment is available, if required, for handling refrigerant cylinders;
z all personal protetive equipment is available and being used correctly;
z the recovery process is supervised at all times by a competent person;
z recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from
various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer ,s instructions.
h) Do not overfill cylinders. (No more than 80% volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that
the cylinders and the equipment are removed from site promptly and all isolation valves
on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has
been cleaned and checked.

71
18. Labelling
 
Equipment shall be labelled stating that it has been de-commissioned and emptied of
refrigerant. The label shall be dated and signed. Ensure that there are labels on the
equipment stating the equipment contains flammable refrigerant.
19. Recovery
When removing refrigerant from a system, either for service or decommissioning, it is
recommended good practice that all refrigerants are removed safely.
When tranferring refrigerant into cylinders, ensure that only appropriate refrigerant
recovery cylinders are employed. Ensure that the correct numbers of cylinders for holding
the total system charge are available. All cylinders to be used are designated for the
recovered refrigerant and labelled for that refrigerant(i.e special cylinders for the
recovery of refrigerant). Cylinders shall be complete with pressure relief valve and
associated shut-off valves in good working order.
Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery of
flammable refrigerants. In addition, a set of calibrated weighing scales shall be available
and in good working order.
Hoses shall be complete with leak-free disconnect couplings and in good condition. Before
using the recovery machine, check that it is in satisfactory working order, has been
properly maintained and that any associated electrical components are sealed to prevent
ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct
recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants
in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been
evacuated to an acceptable level to make certain that flammable refrigerant does not
remain within the lubricant. The evacuation process shall be carried out prior to retruning
the compressor to the suppliers. Only electric heating to the compressor body shall be
employed to accelerate this process. When oil is drained from a system, it shall be carried
out safely.
20. Transportation, marking and storage for units
1. Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
2. Marking of equipment using signs
Compliance with local regulations
3. Disposal of equipment using flammable refrigerants
Compliance with national regulations
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the
equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be
determined by local regulations.

72

C/ PROVENZA 392 P2
08025 BARCELONA
SPAIN
(+34) 93 446 27 80

También podría gustarte