FROM SVANTE ARRHENIUS TO THE DIGITAL pH METER: A CENTURY OF ACIDITY MEASUREMENT. This work describes
the establishment of the concept of pH and the evolution of its measurement. The origin of the pH definition can be found in the
development of the chemistry of aqueous solutions during the XIXth century. The electrolytic dissociation theory by Svante Arrhenius
played a central role. After the proposal of the pH scale by Srensen, many years were necessary for the acceptance of this new
parameter among chemists in general. Its importance was first recognized in biochemistry and related areas. Twenty years after, its
importance had been recognized in many industrial and laboratorial practices. The previous methods were based on colorimetric
and electrometric methods, but both suffered from many problems. Acceptance of pH in Chemistry was only possible after the
development of experimental trustable measurements. The invention of the pH meter was the primordial step.
Keywords: pH; pH meter; acidity measurement.
H+ + OH-
(1)
(2)
Como esse processo ocorre em extenso mnima, a concentrao da gua no equilbrio praticamente igual concentrao inicial, onde:
K[H2O] = K = [H+] [OH-]
(3)
233
234
Gama e Afonso
Quim. Nova
alcalina da cida (Tabela 1). A despeito do ntido apoio de pesquisadores russos e italianos4.5,9.15, a escala de Giribaldo no se consagrou23,29-31. A partir da frmula apresentada na Tabela 1 e da expresso [H+] [OH-] = 1 x 10-14, pde-se demonstrar que os valores de PR
no variavam com o logaritmo da concentrao do on hidrognio,
mas sim com o logaritmo do quadrado dessa concentrao (PR = 14
+ 2 log [H+]), o que amplificava o erro desse parmetro no caso de
medida incorreta de acidez. Apesar de Giribaldo afirmar27,28 que
sua escala era insensvel temperatura (ao contrrio do que sucede
com o pH), o quociente [H+]/[OH-] sensvel s variaes de Kw
com a temperatura, exceto unicamente no caso da neutralidade.
Diversas outras tentativas de se criar uma escala alternativa
quela proposta por Srensen apresentavam frmulas de clculo
mais complexas que a do pH, o que levou ao abandono dessas propostas pela no praticidade no uso rotineiro23.
A dificuldade do conceito de pH se estabelecer entre os qumicos talvez se explique, ao menos em parte, por outro ngulo32: na
dcada de 1920, a teoria de Arrhenius, sob a qual se insere o conceito de pH, sofria duras crticas por conta de suas limitaes
vista do progresso que a Qumica experimentava at ento. As teorias protnicas (Brnsted-Lowry) e eletrnica (Lewis) foram propostas para resolver as lacunas que a teoria de Arrhenius no explicava. Para estas novas teorias o conceito de pH era irrelevante, e
casos onde o pH tinha aplicabilidade duvidosa (caso de meios cidos e bsicos concentrados, reaes em sistemas slidos, etc) passaram a ter um tratamento conceitual.
O conceito de pH foi bem acolhido nos Estados Unidos, era
considerado um meio conveniente de expressar a acidez de solues de cidos/bases e de caracterizar produtos industriais e fisiolgicos9. Na rea de ensino8, em razo da freqncia com a qual se
empregava a expresso pH unicamente como ferramenta de clculo algbrico, foi necessria a publicao de obras que visassem
esclarecer esse novo parmetro fsico-qumico. H. Chakmakjiam,
professor da Escola de Medicina de Boston e membro da Division
of Chemical Education da American Chemical Society defendeu em reunio daquela diviso: A questo que a reduo do
conceito a uma mera operao matemtica incomodava, pois os
alunos aprendiam pH sem relacion-lo aos fenmenos fsico-qumicos pertinentes. Era necessria a juno de conceitos termodinmicos e eletroqumicos para dar uma melhor viso do que ocorre nas solues inicas, dispersando a aura de mistrio que cerca
a mente do aluno31. No incio dos anos 1960, a idia da acidez
crescer com o abaixamento do pH, e vice-versa, era ainda uma
dificuldade apontada pelos alunos no ensino americano23.
A introduo do pH como ferramenta de controle revolucionou
inmeros processos industriais em meio aquoso: precipitaes, culturas bacteriolgicas, produo de vacinas, galvanoplastias, fermenta-
24
Guillaumin25
Wherry
26
Giribaldo27,28
Descrio
Comentrios
235
Ano
Faixa de pH
Srensen
Clark e Lubs
Mc IIvaine
Walpole
Politsch
Mc Clendon et al.
Kolthoff
Ringer
1908
1919
1921
1910
1915
1922
1925
1924
1,04-12,9
01,2-10,0
2,2-8,0
3,8-5,7
06,7-9,24
07,45-9,050
10,17-11,36
10,97-12,06
Mudana de cor
Faixa de
viragem
Azul de timol
Azul de bromofenol
Vermelho de metila
Prpura de bromocresol
Azul de bromotimol
Vermelho de fenol
Vermelho de cresol
Azul de timol
Vermelho-amarelo
Amarelo-azul
Vermelho-amarelo
Amarelo-prpura
Amarelo-azul
Amarelo-vermelho
Amarelo-violeta
Amarelo-azul
1,2-2,8
3,0-4,6
4,4-6,0
5,2-6,8
6,0-7,6
6,8-8,4
7,2-8,8
8,0-9,6
Solues-tampo
KCl 0,2 mol L-1 + HCl 0,2 mol L-1
Ftalato cido de potssio 0,2 mol L-1 +
HCl 0,2 mol L-1
Ftalato cido de potssio 0,2 mol L-1 +
NaOH 0,2 mol L-1
KH2PO4 0,2 mol L-1 + NaOH 0,2 mol L-1
H3BO3 + KCl + NaOH 0,2 mol L-1
1,2-2,2
2,2-3,8
4,0-6,2
5,8-8,0
7,8-9,6
(4)
(5)
236
Gama e Afonso
Quim. Nova
espao13,34,35, pois superavam deficincias dos mtodos colorimtricos, tais como melhor preciso, existncia de solues sem um
bom indicador e determinao de solues coradas19. Apesar de,
em 1893, W. Ostwald j ter medido a concentrao inica utilizando medidas condutimtricas e Walter H. Nernst (1864-1941), em
1889, ter estabelecido uma relao matemtica entre potencial e
concentrao inica, fatores de frum prtico impediam a ampla
utilizao de mtodos eletromtricos. Nos primeiros anos do sculo XX, a precariedade de equipamentos, a carncia de profissionais qualificados para operao dos instrumentos e o alto custo dos
mesmos eram srios entraves difuso dos mtodos eletromtricos
de determinao da acidez de uma soluo13,20,31,41.
As montagens eltricas eram feitas atravs da unio de vrios
componentes, unidos por fios, ou seja, no havia um instrumento
nico para determinao da acidez de uma soluo31,32. Esses esquemas podiam apresentar diversos problemas13,20,42: possibilidade
de ligaes equivocadas ou de inverses de polaridade que levavam a curto-circuitos e mesmo exploses de eletrodos; dificuldade
de ajustar o zero - a flutuao excessiva da corrente levava a
oscilaes que dificultavam medidas reprodutveis; os fios nem
sempre eram verificados quanto sua integridade fsica, bem como
as soldas e junes nas conexes dos diversos componentes; os
eletrodos apresentavam freqentemente defeitos, especialmente o
de hidrognio (negro de platina oxidado ou no homogneo), ou
seja, a baixa durabilidade do instrumento e sua confiabilidade duvidosa; a temperatura da medida era diferente da do ambiente, sem
que se pudessem utilizar fatores de correo no instrumento; o aparecimento do potencial de juno (lquida) entre as clulas e a dificuldade de control-lo, ou, pelo menos, de minimiz-lo.
Um dos componentes obrigatrios dessas montagens era a pilha-padro, que tem a caracterstica de apresentar um potencial
constante e independente do pH, prestando-se para comparao
entre seu potencial e o do sistema que se deseja medir9,15,34,36. A
primeira verso foi proposta em 1872 por Josiah L. Clark (18221898), baseada no sistema Hg(Zn)/ZnSO4 saturado. Foi o primeiro
modelo reprodutvel e de sucesso comercial. Foram introduzidos
melhoramentos, culminando em 1892 pela proposta da chamada
pilha de Weston (Edward Weston, 1850-1936), que tem um potencial de + 1,0183 V 20 oC (constante at cerca de 40 oC), baseada
no sistema Hg(Cd)/HgSO4. Os modelos tinham em comum a entrada para termmetro, ligao (+)/(-) da conexo eltrica, visor de
nvel de lquido e entrada de reposio de gua.
Uma alternativa pilha-padro o eletrodo de referncia (antes
chamada pilha de concentrao). Em 1893, Max J. L. Le Blanc (18651943) mostrou que um eletrodo de platina platinizada funcionava
como um eletrodo reversvel de hidrognio, se este gs fosse borbulhado ao redor do eletrodo. Em 1895, O. F. Tower sugeriu a utilizao de uma soluo concentrada de cloreto de potssio entre as duas
meias clulas para diminuir o potencial de juno lquida12,13,43 (decorrente da diferena de velocidade de migrao (mobilidade) entre
os ons, em especial os ons H+ e OH-, que so mais mveis. Ele
aparece entre duas solues eletrolticas diferentes, que esto em
contato por meio de uma interface). O potencial de juno limita a
exatido da medida porque contribui, com uma parcela desconhecida, para a medida de potencial que aparece entre elas.
Srensen foi o primeiro a utilizar o eletrodo de calomelano
(Hg2Cl2/Hg) para determinar o pH (potencial igual a + 0,246 V
25 oC)20. J em 1906, o bilogo M. Z. Cremer (1865-1935), utilizando uma membrana de vidro, percebeu o aparecimento de um
potencial entre duas solues alcalinas4,5. Por fim, em 1909, Fritz
Haber (1868-1934) e Z. Klemensiewicz (1874-1948) descobriram
que o potencial na membrana de vidro era funo da concentrao
dos ons hidrognio4,5,44.
237
Isso s foi possvel porque Beckman possua um grande conhecimento de engenharia eltrica (componentes eletrnicos e tubos de vcuo), de modo que pde integrar os componentes de seu
aparelho, fato ento indito naquela poca. Seu produto permitia o
emprego do eletrodo de vidro, recm-inventado, o que significou
um salto espetacular na obteno de medidas rpidas e confiveis
da acidez11,48.
Beckman percebeu o grande potencial de mercado que seu produto possua44,47,48 e tentou oferec-lo para vrias indstrias, sem
sucesso. Ento resolveu criar sua prpria empresa. Em 1935, fundou a National Technical Laboratories, que comercializou o primeiro medidor de pH, e que foi o comeo da empresa que hoje
conhecida como Beckman Instruments. Seu aparelho chamavase acid-o-meter, da os termos acidimeter e acidmetro. Por
conta da medida de pH que realiza, o termo peagmetro se imps mais tarde na lngua portuguesa. Em 1935, uma segunda verso do instrumento foi lanada comercialmente, e a patente foi
depositada no ano seguinte. As vendas de peagmetros nos Estados
Unidos saltaram de 444 unidades, em 1936, para quase 2000 unidades, trs anos depois48.
Uma vantagem imediata deste aparelho era o tamanho menor
frente s montagens ento em voga; isso decorria da integrao
dos componentes em um nico aparelho. Ele no funcionava a eletricidade, mas a bateria (chumbo-cido, provavelmente), o que justificava o peso do aparelho em relao ao seu tamanho. Todavia,
isso permitia que fosse transportado para o local onde era necessria a medida de pH, o que era de valor especial nas reas de geologia, agronomia, veterinria e na indstria qumica em geral.
Apesar de ser normalmente creditado a Beckman o lanamento do primeiro peagmetro, deve-se registrar que em 1935 uma
outra proposta desse aparelho foi lanada pela empresa dinamarquesa Radiometer45,49. O que a literatura indica claramente que
ambas as descobertas tiveram como inspirao o trabalho de L.
W. Elder e W. H. Wright50, professores do Departamento de Qumica da Universidade de Illinois. Eles foram os primeiros a sugerir
que as medidas de pH fossem realizadas com eletrodo de vidro e
potencimetro de tubo de vcuo, superando a montagem baseada
na agregao de componentes isolados. Independente de quem ou
qual foi a empresa que inventou o medidor de pH, importante
enfatizar que foi a juno dos conceitos de qumica em soluo
aquosa (pH, tampes), eletroqumica (eletrodo) e eletrnica (medidor) que tornou possvel a concretizao do aparelho.
O advento do peagmetro fez com que a dosagem de acidez
por indicadores corados se restringisse a procedimentos de rotina
238
Gama e Afonso
Quim. Nova
bem estabelecidos, rea de ensino (iniciao s tcnicas de dosagem), ou ainda a casos onde a preciso da medida no precisa ser
rigorosa13,35,42.
A evoluo do peagmetro
Com o passar dos anos, foram introduzidas grandes melhorias
nos medidores de pH at sua forma atual, incluindo eletrodos de
vidro de alta estabilidade, controle por microprocessadores e visores
digitais.
As Figuras 2 a 4 ilustram a evoluo tcnica do instrumento,
visando dar a ele versatilidade e aplicabilidade crescentes.
O primeiro passo foi a eletrificao do aparelho, em contraste
com as primeiras verses (que funcionavam bateria)47. Mas esses
modelos ainda eram muito limitados. No instrumento da dcada
de 1950 (Figura 2), existe apenas um ajuste de escala pelo parafuso preto, realizado ao se colocar uma soluo de pH rigorosamente
7,00; o desvio na escala era compensado pelo ajuste da posio do
ponteiro por meio do parafuso. J os modelos fabricados a partir
do incio dos anos 1960 apresentam uma variedade de recursos
muito maior, com destaque para a introduo do circuito interno
de compensao de temperatura, ponto que responde pela versatilidade do instrumento. A forma de apresentao do resultado passou a ser feita tanto em valores de pH como em milivoltagem; o
mostrador evoluiu do modelo analgico (Figura 3) para o digital
(Figura 4). O ajuste do zero passou a ter dois controles: ajuste grosso
e fino. Os modelos atuais possuem menos de 50% do tamanho dos
instrumentos da dcada de 1980. Alm disso, uma originalidade
a ausncia de botes para controle e ajuste dos parmetros, mas
comandos que so acionadas sob presso.
(7)
(6)
A necessidade de se determinar a acidez de um meio foi reconhecida muito antes de se estabelecerem metodologias experimentais confiveis e reprodutveis de dosagem. Desse modo, pode-se
traar a evoluo da insero da determinao da acidez na rotina
do trabalho em Qumica e outras cincias correlatas, em vrios
estgios distintos: estabelecimento de fatos experimentais e dosagens colorimtricas em base emprica; proposio de teorias que
explicassem os fenmenos observados e de concepes que levariam ao estabelecimento posterior do conceito de pH; adoo de diversos modos de expressar a concentrao do on hidrognio, particularmente aquela proposta por H. Friedenthal; a proposio da
definio de pH, por Srensen e, o desenvolvimento de mtodos
eletromtricos, culminando com a inveno do peagmetro, com o
qual eram superadas as limitaes dos mtodos colorimtricos e as
montagens complicadas e frgeis dos sistemas eltricos de ento.
O conceito de pH adveio de uma situao muito prpria dos
pesquisadores que lidam com sistemas biolgicos, mas esbarrou
no ceticismo e no no reconhecimento imediato pelos qumicos
239