Marc Vorpahl
Universitat Witten/Herdecke, Cardiology, Faculty Member
Research Interests:
Research Interests:
Research Interests:
Research Interests:
Research Interests: Cardiology, Survival Analysis, Risk assessment, Medicine, Fibrin, and 15 moreHumans, Female, Male, Paclitaxel, Registries, Aged, Middle Aged, Drug Eluting Stents, Adult, Public health systems and services research, Risk Assessment, Sirolimus, Stent, stent thrombosis, and Cardiovascular medicine and haematology
Research Interests:
Research Interests: Cardiology, Magnetic Resonance Imaging, Medicine, Humans, Internal Medicine, and 14 moreMale, Clinical Sciences, Middle Aged, Percutaneous Coronary Intervention, Coronary Angiography, Myocardial Infarction, Coronary heart disease, Public health systems and services research, Circulation, Coronary Artery Disease, Ejection Fraction, Right Coronary artery, Cardiovascular medicine and haematology, and Coronary Vessels
Research Interests: Cardiology, Computed Tomography, Medicine, Stents, Stroke, and 13 moreHumans, Female, Two Stroke Engine, Clinical Sciences, Aged, Public health systems and services research, Carotid Stenting, Circulation, X ray Computed Tomography, Embolic Stroke, Carotid Stenosis, Carotid Arteries, and Cardiovascular medicine and haematology
AIMS Transradial access (TRA) has become a standard approach for cardiac catheterization. However, an obstacle to TRA is the risk of radial artery occlusion (RAO) after radial access in about 5%-10% of patients. We analyzed the safety and... more
AIMS Transradial access (TRA) has become a standard approach for cardiac catheterization. However, an obstacle to TRA is the risk of radial artery occlusion (RAO) after radial access in about 5%-10% of patients. We analyzed the safety and efficacy of getting vascular access after RAO by percutaneous transluminal angioplasty in cases of chronic radial occlusion. METHODS AND RESULTS Chronic RAO was confirmed by Allen test and color Doppler in 8 patients. TRA was achieved by puncture in the distal tabatiere (anatomical snuffbox) using Seldinger's technique followed by insertion of a 5 Fr radial introducer sheath. Angiogram was obtained before percutaneous transluminal angioplasty with a 2.0 mm coronary balloon to reopen the artery. Puncture of the occluded radial artery, percutaneous transluminal angioplasty, and subsequent coronary catheterization and PCI were successful in all 8 patients. One complication was a dissection of the radial artery without further adverse events. No he...
Research Interests:
Background: Transcatheter aortic valve replacement is an established treatment option for patients with severe symptomatic aortic stenosis and is most commonly performed through the transfemoral access route. Percutaneous access site... more
Background: Transcatheter aortic valve replacement is an established treatment option for patients with severe symptomatic aortic stenosis and is most commonly performed through the transfemoral access route. Percutaneous access site closure can be achieved using dedicated plug-based or suture-based vascular closure device (VCD) strategies, but randomized comparative studies are scarce. Methods: The CHOICE-CLOSURE trial (Randomized Comparison of Catheter-based Strategies for Interventional Access Site Closure during Transfemoral Transcatheter Aortic Valve Implantation) is an investigator-initiated, multicenter study, in which patients undergoing transfemoral transcatheter aortic valve replacement were randomly assigned to vascular access site closure using either a pure plug-based technique (MANTA, Teleflex) with no additional VCDs or a primary suture-based technique (ProGlide, Abbott Vascular) potentially complemented by a small plug. The primary end point consisted of access site–...
Research Interests:
Research Interests:
Research Interests:
Research Interests:
Medical devices such as implant delivery systems are commonly used during minimally invasive procedures in the cardiovascular system. These devices often have lubricious polymer coatings to reduce friction between the device and blood... more
Medical devices such as implant delivery systems are commonly used during minimally invasive procedures in the cardiovascular system. These devices often have lubricious polymer coatings to reduce friction between the device and blood vessels but coatings may separate and potentially cause serious injuries to patients. Lubricious coated eSheaths for transcatheter heart valve implantation were assessed for luminal integrity at the proximal, medial and distal part. We assessed the number, depths and area of luminal trails using environmental scanning electron microscope (ESEM), white light interferometry (WLI) and optical profilometry using area scale fractal complexity (asfc) as surface parameters. A total of 15 eSheaths were retrieved and analyzed after successful femoral transcatheter Sapien 3 implantation in patients (23 mm valve- 14F eSheath, 26 mm valve- 14F eSheath and 29 mm valve- 16F eSheath, n = 5 for each group). Unused eSheaths (14F and 16F) served as controls (n = 5 for e...
Research Interests:
Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are... more
Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%,p=0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2±1.2 min versus2.3±1.2 min; n.s.), however, greater in the case of cross...
Research Interests:
Innovative catheter systems with lower-profile sheaths and a dynamic expansion mechanism (DEM) were recently introduced for transcatheter aortic valve replacement (TAVR). However, the labeling of 14 F and 16 F eSheaths denote the inner... more
Innovative catheter systems with lower-profile sheaths and a dynamic expansion mechanism (DEM) were recently introduced for transcatheter aortic valve replacement (TAVR). However, the labeling of 14 F and 16 F eSheaths denote the inner nominal diameter. Exact changes of the clinically relevant outer diameters during usage are not available. eSheaths were measured every 30 mm using a digital caliper. Unused 14 F and 16 F eSheaths served as controls. Maximum eSheath diameters were measured after insertion of the Edwards Commander Delivery System (ECDS) into 14 F and 16 F eSheaths.Finally, eSheaths were retrieved and measured after TAVR. Outer diameters of control 14 F eSheaths were 5.8 mm and 6.50 mm for the 16 F eSheath. Introduction of the 23 mm and 26 mm ECDS into 14 F eSheaths showed a maximum diameter of 7.65 mm and 7.64 mm (P=NS). Introduction of the 29 mm ECDS into the 16 F eSheath showed the greatest diameter of 8.18 mm (P=0.03). After TAVR, diameters of the 14 F eSheaths were...
Research Interests:
Transcatheter mitral valve repair has become a promising alternative treatment option for severe symptomatic mitral regurgitation in patients at high risk for open heart surgery with heart-lung bypass. We describe the first successful... more
Transcatheter mitral valve repair has become a promising alternative treatment option for severe symptomatic mitral regurgitation in patients at high risk for open heart surgery with heart-lung bypass. We describe the first successful procedure of mitral clipping through a right lateral mini-thoracotomy via the right upper pulmonary vein in a patient with an agenesis of the inferior vena cava. The set-up of the MitraClip system on a separate table located at 70¡ on the right side of the patient and the fixation of the steerable sheath at the entry into the thorax with constant posterior pressure enabled clip implantation using the usual manoeuvres with marked reduction of the mitral insufficiency. The access through the right upper pulmonary vein using the usual right mini-thoracotomy enabled a successful mitral clipping even in the absence or occlusion of the inferior vena cava.
Research Interests:
Research Interests: Cardiology, Medicine, Humans, Internal Medicine, Male, and 15 moreDislocation, Marfan syndrome, Clinical Sciences, Middle Aged, Coronary Angiography, Myocardial Infarction, Public health systems and services research, Circulation, FOREIGN BODY MIGRATION, Aneurysm, Stent, Chest Pain, Ostium, Cardiovascular medicine and haematology, and Coronary Aneurysm
The mitral clipping technique is emerging as a promising new treatment option for severe mitral regurgitation. The device was designed and assessed in intermediate risk populations, which is in contrast to the real world, where most... more
The mitral clipping technique is emerging as a promising new treatment option for severe mitral regurgitation. The device was designed and assessed in intermediate risk populations, which is in contrast to the real world, where most patients are deemed to be at very high risk for open heart surgery. The cardiac anatomy of these patients often challenges the freedom grades of the current mitral clip device. In this case presentation, we describe a novel technique overcoming extreme atrial dilation in a patient with severe mitral regurgitation despite previous implantation of two mitral clips. Based on a low/anterior trans‐septal puncture, this procedure relied on a counter clock‐wise 90° turn of the steerable sheath and alignment of the clip delivery system to the mitral valve, thereby gaining additional longitudinal freedom. This resulted in the successful implantation of two additional clips with achievement of a mild to moderate mitral regurgitation without relevant gradient and d...
Research Interests: Cardiology, Treatment Outcome, Medicine, Humans, Internal Medicine, and 14 moreMale, Mitral Valve Repair, Aged, Cardiac Catheterization, CLIPS, prosthesis Design, Cardiac Catheters, Mitral regurgitation, Severity of Illness Index, Heart Valve Prosthesis Implantation, Cardiomegaly, Cardiovascular medicine and haematology, Heart atria, and Mitral valve
A buddy wire is often used to aid in the delivery of balloons and stents when negotiating tortuous or calcified vessels. We present a planned two-stent mini-crush intervention complicated by entanglement of the buddy wire with the second... more
A buddy wire is often used to aid in the delivery of balloons and stents when negotiating tortuous or calcified vessels. We present a planned two-stent mini-crush intervention complicated by entanglement of the buddy wire with the second stent and subsequent distortion of the stent within the guiding catheter. Based on this case, we suggest removing the buddy wire immediately after successful positioning of the first stent, because entrapment with a second stent is possible and may lead to challenging situations in a simultaneous two-stent strategy.
Research Interests:
Research Interests:
Research Interests:
Research Interests:
ABSTRACT
Research Interests:
Vulnerable carotid plaques at risk for rupture/ulceration do not always correlate with the severity of stenosis at bifurcation sites. Therefore, information on plaque morphology and composition is essential for identifying patients at... more
Vulnerable carotid plaques at risk for rupture/ulceration do not always correlate with the severity of stenosis at bifurcation sites. Therefore, information on plaque morphology and composition is essential for identifying patients at high risk for acute major cerebrovascular events. Traditional imaging modalities, including angiography and ultrasound, are slowly being replaced by CT imaging, as this technology is readily available in most hospitals and provides high-resolution capabilities at relatively low cost. Improvements in MRI, particularly high-resolution gadolinium-enhanced MRI, currently make this modality the most informative technology, as it allows easy identification of lesion morphometry, calcification, and hemorrhage. Further, multimodal imaging of carotid artery plaques using fluorodeoxyglucose positron emission tomography/CT is slowly growing out of its infancy and is providing valuable information on the inflammatory component of the plaque, a critical indicator o...
Research Interests:
Research Interests:
ABSTRACT
Research Interests:
... AngioDynamics, Inc.; AngioScore, Inc.; Angiomed GmbH & Co.; Angioslide Ltd; Angel Medical Systems, Inc.; Angioblast Systems, Inc.; Apnex Medical, Inc.; Arbor Surgical, Inc.; Ardian, Inc.; Atritech ... Ahmed DD, Sobczak SC,... more
... AngioDynamics, Inc.; AngioScore, Inc.; Angiomed GmbH & Co.; Angioslide Ltd; Angel Medical Systems, Inc.; Angioblast Systems, Inc.; Apnex Medical, Inc.; Arbor Surgical, Inc.; Ardian, Inc.; Atritech ... Ahmed DD, Sobczak SC, Yunginger JW: Occupational allergies caused by latex ...
Research Interests:
Research Interests:
Research Interests:
Research Interests:
Research Interests:
Research Interests:
Research Interests:
Research Interests:
... 1.↵: Kolandaivelu K,; Swaminathan R,; Gibson WJ,; Kolachalama VB,; Nguyen-Ehrenreich KL,; Giddings VL,; Coleman L,; Wong GK,; Edelman ER. . ... Abstract/FREE Full Text. 2.↵: Vorpahl M,; Yazdani SK,; Nakano M,; Ladich E,; Kolodgie FD,;... more
... 1.↵: Kolandaivelu K,; Swaminathan R,; Gibson WJ,; Kolachalama VB,; Nguyen-Ehrenreich KL,; Giddings VL,; Coleman L,; Wong GK,; Edelman ER. . ... Abstract/FREE Full Text. 2.↵: Vorpahl M,; Yazdani SK,; Nakano M,; Ladich E,; Kolodgie FD,; Finn AV,; Virmani R. . Pathobiology of ...
Research Interests:
Research Interests:
Research Interests:
Research Interests:
The aim of this study was to perform pathologic assessment on stent fracture.Clinically, stent fracture has been reported in 1% to 2% of patients after drug-eluting stent (DES) implantation.High-contrast film-based radiographs of 177... more
The aim of this study was to perform pathologic assessment on stent fracture.Clinically, stent fracture has been reported in 1% to 2% of patients after drug-eluting stent (DES) implantation.High-contrast film-based radiographs of 177 consecutive lesions from the CVPath DES autopsy registry were reviewed. Stent fracture was graded as I (single-strut fracture), II (≥2 struts), III (≥2 struts with deformation), IV (with transection without gap), and V (with transection causing gap in stent segment). The incidence of adverse pathologic findings (thrombosis and restenosis) was assessed histologically.Stent fracture was documented in 51 lesions (29%; grade I = 10, II = 14, III = 12, IV = 6, and V = 9). Lesions with stent fracture had longer duration after implantation (172 days [interquartile range (IQR) 31 to 630 days] vs. 44 days [IQR 7 to 270 days], p = 0.004), a higher rate of Cypher (Cordis Corp., Miami Lakes, Florida) stent usage (63% vs. 36%, p = 0.001), longer stent length (30.0 mm [IQR 22.0 to 40.0 mm] vs. 20.0 mm [IQR 14.0 to 27.3 mm], p < 0.0001), and a higher rate of overlapping stents (45% vs. 22%, p = 0.003). Although fracture with grade I to IV did not have significant impact on the occurrence of adverse pathologic findings such as thrombosis and restenosis, 67% of the grade V fracture lesions were associated with adverse pathologic findings at fracture sites. Longer stent length, use of Cypher, and longer duration of implant were identified as independent risk factors of stent fracture by logistic regression analysis.The incidence of stent fracture was 29% lesions at autopsy, which is much higher than clinically reported. A high rate of adverse pathologic findings was observed in lesions with grade V stent fracture, whereas fracture with grade I to IV did not have a significant impact on the pathological outcome.