Does proactive ergonomics program enhance office worker health and productivity? The investigation was conducted in connection with the move of 1500 office staff to a building with improved ergonomics. It was focused on associations... more
Does proactive ergonomics program enhance office worker health and productivity? The investigation was conducted in connection with the move of 1500 office staff to a building with improved ergonomics. It was focused on associations between workstation features, working postures, musculoskeletal pain symptoms, and eye strain before and 18 months after implementation of a proactive ergonomic program. The outcomes were compared between the intervention and a similar reference group. Associations between improvement of postures and less musculoskeletal pain and eye strain were confirmed. A cross association between several features and postures and improved symptoms was noted, along with improved productivity. The study suggests that a proactive program adhering to the OSHA recommendations needs to include an individual workstation assessment to be effective in reducing symptoms and increasing productivity.
To develop a questionnaire (in Spanish) to measure computer-related visual and ocular symptoms (CRVOS). A pilot questionnaire was created by consulting the literature, clinicians, and video display terminal (VDT) workers. The replies of... more
To develop a questionnaire (in Spanish) to measure computer-related visual and ocular symptoms (CRVOS). A pilot questionnaire was created by consulting the literature, clinicians, and video display terminal (VDT) workers. The replies of 636 subjects completing the questionnaire were assessed using the Rasch model and conventional statistics to generate a new scale, designated the Computer-Vision Symptom Scale (CVSS17). Validity and reliability were determined by Rasch fit statistics, principal components analysis (PCA), person separation, differential item functioning (DIF), and item-person targeting. To assess construct validity, the CVSS17 was correlated with a Rasch-based visual discomfort scale (VDS) in 163 VDT workers, this group completed the CVSS17 twice in order to assess test-retest reliability (two-way single-measure intraclass correlation coefficient [ICC] and their 95% confidence intervals, and the coefficient of repeatability [COR]). The CVSS17 contains 17 items explori...
A cross-sectional study was carried out on a sample of 26 VDU operators in a post office and a bank, working regularly on video display units. The study aimed at (1) determining the physical working conditions, particularly lighting... more
A cross-sectional study was carried out on a sample of 26 VDU operators in a post office and a bank, working regularly on video display units. The study aimed at (1) determining the physical working conditions, particularly lighting conditions, (2) assessing employees' complaints, (3) measuring visual defects among operators in VDU workstations. The following results are revealed: (a) ergonomic shortcomings in workplace and work station design were clearly noticed (b) noise level was between 60 db and 78 db, (c) illumination parameters did not much the task and caused ocular symptoms and visual fatigue, (d) visual tests revealed vision defects in 84.6% of the cases, (e) visual fatigue was noticed at the end of the working day. The abnormal frequency of operators' complaints can be explained by the association of visual defects and inadequate working conditions.
An increasing number of people seek medical attention for symptoms of visual discomfort due to computer vision syndrome (CVS). We compared the efficacy and adverse event rates of a new eye lubricant, OptiZen (InnoZen, Inc., polysorbate 80... more
An increasing number of people seek medical attention for symptoms of visual discomfort due to computer vision syndrome (CVS). We compared the efficacy and adverse event rates of a new eye lubricant, OptiZen (InnoZen, Inc., polysorbate 80 0.5%) and Visine Original (Pfizer Consumer Healthcare, tetrahydrozoline HCl 0.05%). In this double-blind parallel arm trial, 50 healthy men and women, ages 18 to 65 years, with symptoms of CVS who use a video display terminal for a minimum of 4 hours per day were randomized to OptiZen (n = 25) or Visine Original (n= 25), 1 to 2 drops b.i.d. for 5 days. The primary end-points were ocular discomfort and adverse events. OptiZen and Visine Original had similar efficacy in alleviating symptoms of ocular discomfort (odds ratio of 1.23 [95% confidence interval, 0.63 to 2.42], P= 0.55). OptiZen and Visine Original were very similar with respect to odds ratios and 95% confidence interval (CI) for each of the measurement times (P= 0.72). Visine Original user...
Examine the effect of a multi-component office ergonomics intervention on visual symptom reductions.Office workers were assigned to either a group receiving a highly adjustable chair with office ergonomics training (CWT), a training-only... more
Examine the effect of a multi-component office ergonomics intervention on visual symptom reductions.Office workers were assigned to either a group receiving a highly adjustable chair with office ergonomics training (CWT), a training-only group (TO) or a control group (C). A work environment and health questionnaire was administered 2 and 1 month(s) pre-intervention and 3, 6, and 12 months post-intervention. Multi-level statistical models tested hypotheses.The CWT intervention lowered daily visual symptoms (p < 0.01) post-intervention. The TO group did not significantly differ from the control group. The CWT group differed significantly from the TO group (p = 0.01) post-intervention.Workers who received a highly adjustable chair and office ergonomics training had reduced visual symptoms and the effect was maintained through twelve months post-intervention. The lack of a training-only group effect supports implementing training in conjunction with the highly adjustable chair to reduce visual symptoms.► There remains little intervention research on how to improve visual health. ► A highly adjustable chair with an office ergonomics training reduced visual symptoms. ► Symptom reduction was maintained through 12 months of follow-up. ► Office ergonomics training alone did not reduce visual symptoms. ► There is a need for replication studies.
The aims of this study were to evaluate the employees' subjective assessments of different aspects of lighting condition as well as task area illuminance in manufacturing plants. This field study was conducted between March and May... more
The aims of this study were to evaluate the employees' subjective assessments of different aspects of lighting condition as well as task area illuminance in manufacturing plants. This field study was conducted between March and May 2013, in three packing plants (Saveh, central Iran). Data were collected by questionnaire and measurement of the task area illuminance levels. Data were analysed using contingency coefficient test, Spearman's correlation analysis and non-parametric Friedman tests. The recommended illuminance levels were not met in 46.9% of the work areas. This finding was in agreement with the employees' perception of light level, and with low satisfaction with lighting in the work environment. Adverse effects of lighting condition on job performance, changing posture for better viewing of the work area and eye tiredness were reported as 64%, 33% and 31% of the employees, respectively. Satisfaction with lighting was negatively correlated with the age of respon...
The mass digitization of books is changing the way information is created, disseminated and displayed. Electronic book readers (e-readers) generally refer to two main display technologies: the electronic ink (E-ink) and the liquid crystal... more
The mass digitization of books is changing the way information is created, disseminated and displayed. Electronic book readers (e-readers) generally refer to two main display technologies: the electronic ink (E-ink) and the liquid crystal display (LCD). Both technologies have advantages and disadvantages, but the question whether one or the other triggers less visual fatigue is still open. The aim of the present research was to study the effects of the display technology on visual fatigue. To this end, participants performed a longitudinal study in which two last generation e-readers (LCD, E-ink) and paper book were tested in three different prolonged reading sessions separated by- on average- ten days. Results from both objective (Blinks per second) and subjective (Visual Fatigue Scale) measures suggested that reading on the LCD (Kindle Fire HD) triggers higher visual fatigue with respect to both the E-ink (Kindle Paperwhite) and the paper book. The absence of differences between E...
High comorbidity and an overlap in symptomology have been demonstrated between dyslexia and visual stress. Several researchers have hypothesized an underlying or causal influence that may account for this relationship. The magnocellular... more
High comorbidity and an overlap in symptomology have been demonstrated between dyslexia and visual stress. Several researchers have hypothesized an underlying or causal influence that may account for this relationship. The magnocellular theory of dyslexia proposes that a deficit in visuo-temporal processing can explain symptomology for both disorders. If the magnocellular theory holds true, individuals who experience symptomology for these disorders should show impairment on a visuo-temporal task, such as driving. Eighteen male participants formed the sample for this study. Self-report measures assessed dyslexia and visual stress symptomology as well as participant IQ. Participants completed a drive simulation in which errors in response to road signs were measured. Bivariate correlations revealed significant associations between scores on measures of dyslexia and visual stress. Results also demonstrated that self-reported symptomology predicts magnocellular impairment as measured b...
When observers focus their stereoscopic visual system for a long time (e.g., watching a 3D movie) they may experience visual discomfort or asthenopia. We tested two types of models for predicting visual fatigue in a task in which subjects... more
When observers focus their stereoscopic visual system for a long time (e.g., watching a 3D movie) they may experience visual discomfort or asthenopia. We tested two types of models for predicting visual fatigue in a task in which subjects were instructed to discriminate between 3D characters. One model was based on viewing distance (focal distance, vergence distance) and another in visual direction (oculomotor imbalance). A 3D test was designed to assess binocular visual fatigue while looking at 3D stimuli located in different visual directions and viewed from two distances from the screen. The observers were tested under three conditions: (a) normal vision; (b) wearing a lens (-2 diop.); (c) wearing a base-out prism (2▿) over each eye. Sensitivity and specificity were calculated (as Signal Detection Theory parameters: SDT). An ANOVA and SDT analyses revealed that impaired visual performance were directly related to short distance and larger deviation in visual direction, particular...
Visual stress (VS) is characterised by symptoms of visual perceptual distortions and eyestrain when viewing text, symptoms that are alleviated by individually prescribed coloured filters. A recent review supports the existence of VS and... more
Visual stress (VS) is characterised by symptoms of visual perceptual distortions and eyestrain when viewing text, symptoms that are alleviated by individually prescribed coloured filters. A recent review supports the existence of VS and its treatment, but noted that controversy remains, in part due to inconsistencies in the diagnosis of the condition. The present paper reviews the diagnostic criteria for VS in the literature and reports a Delphi analysis of the criteria currently used in clinical practice. Twenty-six eyecare practitioners were invited to participate in a Delphi study. They were selected because they were frequent prescribers of precision tinted lenses. In the first round they were sent a list of the indicators for which there is literature to suggest a relevance in the diagnosis of VS. The practitioners were invited to rank the indicators and add any additional criteria they use in diagnosis. In the second round a revised list was circulated, including items added f...
This study examined the effects of supplementary rest breaks on musculoskeletal discomfort, eyestrain, mood, and performance in data-entry workers. Two rest break schedules were compared in a within-subjects design. Workers alternated... more
This study examined the effects of supplementary rest breaks on musculoskeletal discomfort, eyestrain, mood, and performance in data-entry workers. Two rest break schedules were compared in a within-subjects design. Workers alternated between a &#39;conventional&#39; and a &#39;supplementary&#39; schedule in 4-week intervals. The conventional schedule contained a 15-min break during the first half of the work shift and a 15-min break during the second half of the shift. The supplementary schedule contained the same two 15-min breaks, and a 5-min break during each hour which otherwise did not contain a break, for a total of 20 extra minutes of break time. Results are based on data from 42 workers. They indicated that discomfort in several areas of the body, and eyestrain, were significantly lower under the supplementary than under the conventional schedule. While symptoms increased from pre- to post-work periods under both schedules, the magnitude of the increases was significantly less under the supplementary schedule. In addition, increases in discomfort of the right forearm, wrist and hand over the course of the work week under the conventional schedule were eliminated under the supplementary schedule. These beneficial effects were obtained without reductions in data-entry performance.
The purpose of this study was to determine whether subjects who wear short wavelength-blocking eyeglasses during computer tasks exhibit less visual fatigue and report fewer symptoms of visual discomfort than subjects wearing eyeglasses... more
The purpose of this study was to determine whether subjects who wear short wavelength-blocking eyeglasses during computer tasks exhibit less visual fatigue and report fewer symptoms of visual discomfort than subjects wearing eyeglasses with clear lenses. A total of 36 healthy subjects (20 male; 16 female) was randomized to wearing no-block, low-blocking, or high-blocking eyeglasses while performing a 2-hour computer task. A masked grader measured critical flicker fusion frequency (CFF) as a metric of eye fatigue and evaluated symptoms of eye strain with a 15-item questionnaire before and after computer use. We found that the change in CFF after the computer task was significantly more positive (i.e., less eye fatigue) in the high-block versus the no-block (P = 0.027) and low-block (P = 0.008) groups. Moreover, random assignment to the high-block group but not to the low-block group predicted a more positive change in CFF (i.e., less eye fatigue) following the computer task (adjusted...
The aim of the study was to analyze discomfort glare sensation in subjects aged 50 years and more in comparison with younger subjects (i.e. younger than 35 years of age). The experiments were performed on a computer workstation placed in... more
The aim of the study was to analyze discomfort glare sensation in subjects aged 50 years and more in comparison with younger subjects (i.e. younger than 35 years of age). The experiments were performed on a computer workstation placed in controlled lighting environment where 2 discomfort glare conditions were modeled. Each participant performed for about 1 h specially designed visual tasks, including the tests with Landolt's rings presented on the screen by a computer program. The glare evaluation method consisted of subjective evaluation of discomfort glare on the semantic glare rating scale, tests of mesopic contrast and glare sensitivity, subjective assessment of lighting quality and asthenopic symptoms. The time needed to perform the task and the number of mistakes were also recorded. The subjective evaluation of glare was compared with the Unified Glare Rating (UGR) index calculated by the DIALux simulation program. A higher percentage of the younger group subjects assessed...