Thermowell Pseudo First Order System
Thermowell Pseudo First Order System
Thermowell Pseudo First Order System
Temperature
observed (C)
Time constant
(sec)
Time (sec)
Error in
Tau (%)
Temperature
Predicted (C)
Error in
Temperature (%)
93
93
91
32.15
1012.64
15.12
91.30
0.33
89
69
1069.13
10.39
89.40
0.45
87
105
1066.64
10.59
87.61
0.70
85
145
1085.89
8.98
85.68
0.79
83
183
1077.11
9.72
83.90
1.08
81
225
1083.61
9.17
82.00
1.23
79
270
1093.74
8.32
80.04
1.31
77
321
1115.82
6.47
77.90
1.17
75
374
1132.50
5.07
75.78
1.04
73
423
1128.92
5.37
73.89
1.23
71
480
1139.56
4.48
71.80
1.13
69
538
1144.67
4.05
69.77
1.12
67
599
1149.06
3.69
67.74
1.10
65
662
1150.58
3.56
65.74
1.15
63
736
1163.59
2.47
63.53
0.85
61
818
1180.12
1.08
61.24
0.39
59
901
1189.15
0.33
59.07
0.13
57
988
1195.14
0.18
56.96
0.07
55
1081
1200.06
0.59
54.86
0.25
53
1191
1214.28
1.78
52.58
0.78
51
1311
1227.71
2.91
50.33
1.32
49
1453
1249.19
4.71
47.93
2.17
47
1621
1277.88
7.11
45.45
3.30
45
1793
1293.38
8.41
43.24
3.91
43
1981
1303.44
9.25
41.16
4.27
41
2220
1326.18
11.16
38.96
4.99
39
2505
1349.46
13.11
36.84
5.54
37
2875
1382.58
15.89
34.75
6.08
35
3248
1372.13
15.01
33.21
5.13
34
3612
1416.78
18.75
32.10
5.59
Tau average
1193.03
Graph100
90
temperature (C)
80
70
60
50
40
30
0
300
600
900
1200
1500
1800
2100
Time (sec)
2400
2700
3000
3300
3600