MCB2300 Can
MCB2300 Can
MCB2300 Can
Summer 2009
by Robert Boys, Version 1.01 bob.boys@arm.com San Jose, California
Introduction:
CAN is extensively used in automobiles and trucks but has found applications everywhere. There are many application layers available for CAN such as ISO 15765 (cars), J1939 (trucks) and CANopen (factory automation) but it is very easy to develop your own protocol that will fit and simplify your needs. Modern CAN transceivers provide a stable and reliable CAN physical environment without the need for expensive coaxial cables. Most of the mystery of CAN has dissipated over the years. There is plenty of example CAN software available to help you quickly develop your own network. A CAN controller is a sophisticated device. Nearly all the features of the CAN protocol described below are automatically handled by the controller with almost no intervention by the host processor. All you need to do is configure the controller by writing to its registers, write data to the controller and the controller then does all the housekeeping work to get your message on the bus. The controller will also read any frames it sees on the bus and hold them in a small FIFO memory. It will notify the host processor that this data is available which you then read from the controller. The controller also contains a hardware filter mechanism called an Acceptance Filter that can be programmed to ignore those CAN frames you do not want passed to the processor. See app note AN10674 for more information: www.nxp.com/microcontrollers.
The main CAN backbone and drops are comprised of a twisted pair of wires. drops
Node 1
Node 2
Node 3
Node 4
Node 5
Node 6
a,b = 120 watt termination resistors. Drops use the same twisted pair of wires as the backbone.
www.keil.com
A Node Schematic:
This is the CAN1 schematic diagram from the Keil MCB2300 evaluation board which has two independent CAN channels. This board is available populated with a LPC2368, LPC2378, LPC2387 or a LPC2388 ARM7 processor. IC5 is a TJA1040 NXP CAN transceiver which performs the conversion between the single-ended CAN controller TD1 or TD2 and RD1 or RD2 signals to the bi-directional differential pair of the CAN bus called CANH and CANL (High and Low). This transceiver IC5 connects to the NXP LPC2300 series microprocessor IC4 which contains two CAN controllers via two sets of pins: TXD (Driver input) and RXD (Receiver output). The corresponding nomenclature on the LPC2300 is TD1 and RD1. TD1 connects to TXD. RD1 connects to RXD. It is that simple. Multiple CAN controllers in the same processor are often used in routers, gateways or to create more receiver FIFO memory for intentionally slowed down CPUs (for EMI reasons). For general use, a node normally needs only one controller. If it had at least two, it could talk to itself.
STB on IC3 when low enables the Transceiver. This can be useful for low power modes or when the CAN controller is in Buss-off mode. This will effectively remove the node from the bus. TIP: You will have to use hardware to use this feature. Note R12 and R13, two 60 ohm termination resistors. The TJA1040 has provisions for split termination which offers greater noise immunity, especially at higher CAN speeds. Two 60 ohm resistors are used in series with capacitor C45. This evaluation board can be used as a small, two node test network since it contains two separate CAN nodes. If this board is used as a node, and is not at one of the ends, the termination resistors should be removed and external resistors used. Connector CAN1 corresponds to a generally accepted standard for CAN on DB9 connectors. Pin 7 is the CAN Hi bus line and pin 2 is CAN Lo. TIP: If CAN Hi and CAN Lo are reversed, the network will not operate properly.
2. Display a trace. You might need a storage scope to see just one trace due to the non-repetitive nature of CAN. 3. Pick the smallest width signal pulse and measure its time period in seconds as accurately as you can. 4. Invert this value (divide into 1) and you have the CAN speed in bits per second.
www.keil.com
Data Bytes: 0 through 8 bytes. TIP: A CAN frame with only an ID field and no data bytes is valid and useful.
2. An ID of 0 has the highest priority and will always get through. An 11 bit ID has priority over any 29 bit ID. 3. You can change the ID size at any time for a mix of 11 and 29 bit IDs. The controller can easily sort this out. 4. Messages tend to start transmitting at the same time. It is not permissible for a CAN node to start transmitting if another is already transmitting. This will cause a bus error. CAN controllers will not make this mistake. 5. TIP: Note that CAN controllers can be configured to pass only certain messages to its host processor. Choose your ID values carefully to take advantage of this if needed. This can take a large work load off a nodes processor. 6. You can use the ID for data, node addressing, commands and request/response sequences. Commercial protocols use any of these in practice. You can choose any method or create your own that best suits your purpose. 7. TIP: Make sure two nodes never send the same ID value at the same time. It is illegal but possible to do this. If two messages sent at the same time are identical, they will be seen as one. If the data bytes are different, this will result in a bus error and the frames will be resent continuously. This creates havoc on the bus until bus-off occurs.
Data Bytes:
You can select from 0 to 8 data bytes using the 4 bit DLC field. 1. You can have any number of data bytes mixed on the CAN bus. The controller can easily sort this out. 2. TIP: If you always use only one number of data bytes, your software will be much simpler to write and maintain. 3. The data bytes can contain anything. It will not be prioritized like the ID is. CAN does not specify data contents. 4. Commercial protocols such as J1939 use these for data as well as control bits for multi-frame transmissions.
Remote Frames:
These are not used much but are worth mentioning. A remote frame is a quick method of getting a response from another node(s). It is a request for data. The requesting node sends out a shortened CAN frame with only a user specified ID number and the number of data bytes it expects to receive (the DLC is set). No data field is sent. The responding node(s) sees this ID and DLC, recognizes that it has the desired information and sends back a standard CAN frame with the same ID, DLC and with its data bytes attached. All of this (except that the response node recognizes the ID and DLC) is implemented in the CAN controller hardware. Everything else must be configured by the user software.
Other Bit Fields: Only the ACK bit will be mentioned in this document:
ACK: Is a 1 bit field in the CAN frame created by the transmitting node but set by all the other nodes. TIP: The number one reason people cant get their CAN node working is you need at least two nodes to work. When a node puts a message on the bus, it will wait for the ACK bit to be asserted by any other node that has seen the message and determines it to be valid. If so, the transmitting node finishes the message and goes into the idle state or sends its next message. If not, it will immediately resend the message forever until the ACK is inserted or the controller is RESET. This transmitting node will never go into bus-off mode. Note that a standard CAN test tool will usually act as a second node.
www.keil.com
TIP: This presents an excellent opportunity to provide an easy test situation. If you cant get your network to work try this. It wont tell you if your frequency, ID or data bytes are correct, but it will tell you if you are putting out something. 1. Construct your CAN node with a transceiver connected to the CAN controller and a termination resistor. 2. Do not connect any other node or test tool. Just one node running by itself with at least one 120 ohm resistor. 3. Connect an oscilloscope hot lead to CAN Hi and ground to CAN Lo. The scope ground must be isolated from the CAN ground. You do not need a high speed scope almost any will suffice. You can also connect a scope to the CAN controller output pin and ground. If you connect from CAN Hi or Lo and ground, your signal will be smaller. 4. Configure your CAN controller and write the IDE, ID, DLC and any data bytes into the appropriate register. 5. Any CAN frames will now be continuously displayed on the scope. RESET the processor to start over. TIP: You can measure the CAN frequency with the method described in the TIP: under Physical Layer.
Bus Loading:
Many CAN networks work on a bus loading from 15 to 35 % and this is increasing. A higher bus loading can cause lower priority messages to be delayed but these messages will still get through in a timely fashion. It is quite difficult to achieve 100% bus loading although one can come quite close. Overall system performance does not drop greatly at high loading. TIP: It is possible to get very high bus loads for a very short period of time in any CAN network. CAN does not automatically space out messages. It is possible to get a series of back-to-back messages that will equal nearly 100 % bus loading. You should be prepared for this. One solution is to select only those messages needed by a node by programming its acceptance filter. Another is to have your software space out the messages. This problem is quite hard to diagnose.
Bus Speed:
Bus speed in a system is a balancing act between things such as propagation delays (from bus length) and EMI emissions versus necessary data throughput. Run your network as fast as possible for stable operation and with enough throughput. Do not run it faster than it needs to be, but make some room for later expansion. TIP: If your network is not stable: make sure you have two termination resistors at each end of the network. Try slowing the CAN speed down to see if this helps. Resistors can be ordinary 120 ohm watt carbon type. They are not critical.
Bus Errors:
Recall we said that all the nodes (including the transmitting node) checks each CAN frame for errors. If an error is detected, here is what happens: 1. Any or all the nodes will signify this fact by driving the bus to logical 0 (dominant state) for at least 6 CAN bits. 2. This violates the Bit Stuffing rule (never greater than 5 bits the same polarity) so every node sees this as an error. 3. This so called Error Frame signals to all nodes a serious error has occurred if they dont already know it. 4. The transmitting bus abandons the current frame and adds 4 to its 8 bit TEC register. (transmit error counter) 5. IF this TEC equals 0xFF, the transmitting node goes BUS OFF and takes itself off the bus. (it is zero at RESET) 6. IF not, it attempts to retransmit. It will still have to go through the priority process with any other messages. 7. All other nodes also abandon reading the current frame, and adds 4 to each REC register. (receive error counter) 8. Any nodes that have messages queued up for transmission will transmit now. All others start listening to the bus. 9. Hopefully, this time the message(s) will be broadcast and received error free. Each time a frame is transmitted and/or received successfully, the corresponding TEC and REC registers are decremented (usually by only 1) Super TIP: Error Counters ? These are two 8 bit registers in every CAN controller and you can read these with your software. This is a good idea because it gives some indication of general bus health and stability. In a good CAN network, TEC and REC will equal 0. If it starts having higher values, something has happened to your network. The usual suspect is bad hardware. The problem is usually in either the wires or the transceiver chip. TIP: Dont forget that if something happens to the integrity of your twisted pair, such as CAN Lo disconnected; it might still work but with greatly reduced noise immunity (that is what differential signals do best). If your network is in a very noisy environment, there might be a lot more transient bus errors. This is very tricky to debug without knowledge of the REC and TEC register contents. Read TEC and REC with your software and report it to your diagnostic routines. In a general sense, TEC represents a given nodes errors and REC indicates the other nodes errors. Bus Off: As mentioned, if a transmitting node detects it has put too many bad frames on the bus, it will disconnect itself. It will assume that there is something very wrong with itself. To get back on the bus depends on how you configure the controller. It can take a controller RESET or a certain number of good frames received or other situations. 4
www.keil.com
BUS Faults:
This is different (sort of) from a bus error. We normally think of a bus fault as something that has happened to the wires or the output transistors of the transceiver chip. Not all bus faults will result in a bus error. A bus error can be thought as the CAN controllers reaction to a problem on the bus such as noise, faulty node that includes a bus fault. What happens if one of the twisted pair opens or is shorted out ? CAN has an automatic mechanisms for this. Not all transceiver chips implement all of them. You can usually short CAN Lo to ground (ISO 11898 says can short Hi also) or open one CAN line. The ground needs to be connected for these to function. You cant short both Hi and Lo together or open both up. You can cut the ground or have a large ground loop present and CAN will still work. These will be detected as a bus error as described above. At least one node must try to transmit a frame in a bus fault condition to trigger a bus error. A bus in idle mode cant trigger a bus error. When the bus fault is removed, in many systems the network will come back alive if so configured. CAN has excellent noise immunity because of the twisted pair. The common mode noise gets cancelled out and the CAN signal is not affected at all because it is 180 degrees out of phase. The Ground: Strictly speaking, the ground is not needed for CAN operation if the twisted pair is intact. This is readily shown with simple experiments. One experiment showed a small network still worked properly with two nodes having a 40 volts DC ground difference ! However, it is a good idea to include a good ground in your system design. Some bus faults need the ground to allow the transceiver to compensate and keep the network running. TIP: How can you create a Bus Error for testing ? Easy: have a node send a message at the wrong frequency. When this frame tries to get on the bus this is certain to create a bus error condition. Some CAN controllers can send a one-shot frame which will simplify your testing procedure.
Bonus TIPS: Here some items not part of the CAN specification but might prove helpful in your system: 1) Transmitting data sets greater than 8 bytes:
Clearly, transmitting a data set greater than 8 bytes will take multiple frames and this will require some planning. Such schemes can become very complicated as they have to deal with a wide-ranging set of contingencies. If you can focus on a narrow requirement set, design of a simpler protocol is possible. Most current schemes use the first data byte to contain the number of total data bytes to follow plus a counter to help determine which data byte is which. The ID usually identifies the node plus whether is the request or response message. If you want to use an existing protocol see ISO 15765. This is what automobiles use. This includes OBDII diagnostics which is public information. This is a good example where one message can be comprised of many CAN frames.
3) Time-outs:
Automotive CAN networks use time-outs and this concept is easily and effectively transferred to systems in other fields. A time-out occurs when a node fails to respond to a request in a timely fashion. Time-outs are handled completely by software. The CAN specification does not provide this mechanism. A time-out is helpful to recover from problems with the network such as severe bus errors, catastrophic bus faults, faulty nodes or intermittent connections. The result is usually a limp-home mode where a node will attempt to run itself without information from the rest of the network. In some cases, a punitive limp-home mode is entered that forces the user to perform repairs. A good example is if the transmission fails and proper shifting becomes impossible. In this case, the module will go into limp-home mode and the transmission might be put into one gear such as second to allow the vehicle to still be driven. This can be for safety reasons or to prevent further damage to the power train. Heart-beats and Address Claiming: The other side to a time-out is a heart beat. Periodic messages can be sent out to determine that all nodes are on the bus and active. CANopen uses such heart-beats. J1939 has a software mechanism where each node can declare itself to be on the bus and be recognized by the other nodes. This is called Address Claiming and occurs during the system startup. Your software provides these mechanisms and not the CAN specification. 5
www.keil.com
Sequence of Transmitting Data on the CAN Bus: (this is done automatically by the controller)
1. Any node(s), seeing the bus idle for the required minimum time, can start sending a CAN frame. 2. All other nodes start receiving it except those also starting to transmit a message. (they all start at the same time) 3. If any other node starts transmitting: the priority process starts the node with the highest priority continues on and those with a lesser priority stops sending, turns into a receiver and receives the higher priority message. 4. At this point, only one node is transmitting a message and no other will start at this time. 5. When the transmitting node has completed sending its message, it waits one bit time for the 1 bit ACK field to be pulled to a logic 0 by any other node (or usually all of them) to signify the frame was received without errors. 6. If this happens, the transmitting node assumes the message reached its recipient, sends the end-of-frame bits and goes into receive mode or starts to send its next message if it has one. The receiving nodes pass the received message to their host processors for processing unless the acceptance filtering prevents this action. 7. At this time, any node can start sending any messages or the bus goes into the idle state. Go to 1. 8. If this does not happen (ACK bit not set) then the transmitting retransmits the message at the earliest time allowed. If the ACK bit is never set, the transmitting node will send this message forever. Transmitting Notes: How does a node know when it should transmit a message ? Easy you create the CAN frame you want to send by loading up the IDE, ID, DLC and any data byte registers in the CAN controller and then, in most controllers, you set a bit that triggers sending the frame. After this, the controller takes care of sending all frame bits. Unless the controller signals otherwise to the processor, you can assume the message was sent. What if there is an error ? All nodes, including the transmitting node, monitor the bus for any errors. If an error condition is detected a node or nodes signify to the other nodes there is an error by holding the bus at logical 0 for at least 6 bus cycles. At this point, all nodes take appropriate action. The message being sent (and now aborted) will be resent but only for a certain number of times. See Bus Errors on page 4. What if no node wants or uses the message ? Nothing. The ACK bit only says that the CAN frame was transmitted without errors and at least one node saw this frame error free. Remember the transmitting frame cant ACK itself. CAN does not provide any acknowledgment mechanism that a frame was used or not by its intended recipient. If needed, you will have to provide this in your software as many systems do. TIP: In a periodic system, if a node misses a message, it doesnt matter much as another one will be along shortly. All nodes except those currently transmitting frames are in listening mode. A CAN frame is sent using the procedure as described above:
Sequence of Transmitting data on the CAN Bus:
This frame is received by all listening nodes. If deemed to be a valid CAN message with no errors the ACK bit is set. In CAN terminology, this set to the dominant state as opposed to the recessive state. The frame is sent through the controllers acceptance filter mechanism. If this frame is rejected it is discarded. If accepted it is sent to the controller FIFO memory. If the FIFO is full, the oldest frame is lost. The host processor is alerted to the fact a valid frame is ready to be read from the FIFO. This is done either by an interrupt or a bit set in a controller register. This frame must be read as soon as possible. The host processor decides what to do with this message as determined by your software. TIP: You must decide whether to use polling or interrupts to alert the host processor a frame is available. Polling is where the host processor polls or continuously tests the bit mentioned in # 5. Polling runs the risk of losing or dropping a frame but is sometimes easier to implement and debug. Interrupts cause the processor to jump to an interrupt handler where the frame is read from the controller. Using interrupts is the recommended method. What happens if a message is dropped ? This can cause some problems as CAN itself does not have a mechanism for acknowledging a CAN frame. If you want this, you must add it to your software. In the case of Periodic Messages, it doesnt normally matter much as a replacement message will be along shortly. How fast do I have to read the FIFO to not drop messages ? It depends on the CAN speed, frame size, and bus loading. It is a good idea to read these frames as soon as possible since if a frame is dropped, it will not be automatically recovered or resent by the transmitting node. It is gone forever unless you provide a suitable mechanism in your software to have it resent.
Receiving Notes:
www.keil.com
Test Tools:
The biggest problem in getting your first CAN network running is that in order to see some messages, you have to have both a receiving node and a transmitting node properly working at the same time. This can be quite the onerous job. There are two ways to help here. One is to use a working node such as an evaluation board with proven CAN examples. You can attempt to receive these known good CAN frames with your node. An example is provided in this document. Second, you can purchase a CAN test tool. This is the best idea. These provide both sending and receiving capabilities and act as a CAN node. There are two types: simple low cost devices that provide basic creating and displaying bus traffic and those offering advanced capabilities. There are essentially two types: simple low cost tools and ones for power developers. Typical sources for inexpensive tools are SYS TEC www.phytec.com, www.kvaser.com and PEAK www.peak-system.com which is also sold in the USA through www.phytec.com. There are many other companies that sell these types of inexpensive tools. Search on the Internet to find these. If you are developing a more capable and powerful CAN system, you should consider a CAN analyzer. These offer very advanced features such as triggering, filtering and best of all; a database where your ID and data bytes are displayed in words rather than raw hex numbers. This will save a lot of time and make for a better, more reliable product. Typical suppliers are Dearborn Group www.dgtech.com , Vector CANalyzer www.vector.com , National Instruments www.ni.com and Intrepid www.intrepidcs.com. Do not be afraid to use an automotive type device even if your application is something else. CAN is CAN no matter where it is used and no matter what anybody says. Everything else sits on top of CAN.
Bit Stuffing:
The CAN protocol states that when there are 5 consecutive bits of the same polarity, one bit of opposite polarity will be inserted to maintain the counter accuracy. These bits make the CAN frame longer and are very common. These bits are inserted and removed automatically by the CAN controller and are only visible when an oscilloscope is attached to the bus. TIP: When bits are added (or not) to the CAN frame as various messages are sent on the bus, the changing frame length will look like jitter on the bus. It is not jitter of course; CAN just works this way. Just something to be aware of.
Conclusion:
You now have enough CAN theory to enable you to develop and troubleshoot a small CAN network. Now, on the next few pages, let us look at how we can program a real CAN controller to transmit and receive messages. There are some hands-on experiments you can try the Keil evaluation software is free and for one experiment no hardware is needed. For the other, you will need an evaluation board with a NXP processor with CAN (most of their chips have two which is very handy) and a Keil ULINK2 or ULINK-ME USB to JTAG adapter. For more information relating to CAN please see www.dgtech.com/pdfs/techpapers/primer.pdf For information regarding testing CAN networks: www.dgtech.com/pdfs/techpapers/CIA_article.pdf For CANopen and other information see: www.can-cia.org (most CANopen docs are free) A differential twisted pair of wires with two 120 termination resistors: This is the minimum network of 2 nodes. The MCB2300 requires a cable like this but without the resistors as these are on the board.
www.keil.com
8 8
www.keil.com
2. Select Project/Open Project. Open the file C:\Keil\ARM\Boards\Keil\MCB2300\CAN\CAN.Uv2. 3. Make sure Simulator is selected in the Target window. 4. Compile the source files by clicking on the Build icon. 5. Click on the Options for Target icon. . They will compile with no errors or warnings.
Select the Debug tab and confirm Use Simulator is checked. Click OK. Select OK when the Evaluation Mode box appears.
Position the Toolbox, CAN: Communication and CAN: Controller windows. Open them from Peripherals/CAN Note: you can stop the program with the STOP icon.
9. Note CAN messages with an ID of 0x21 will appear in the CAN: Communications window. You can see both the transmit and receive frames. It might take several seconds for the first messages to appear the first time. You might have to click on CAN loopback ON in the Toolbox window as shown to start the frames. 10. In the Toolbox window, click on the Analog Sweep 03.3v. 11. Changing data values representing output from the A/D convertor will now appear in the CAN data field in the CAN Communication window.
1) Can.h
The CAN Structure CAN_Msg: (lines 31-37, 47 & 48) Shown is the structure declaration in Can.h. You should now be able to recognize each of these elements. You can enter either an 11 or 29 bit identifier. Four instances of CAN.msg are invoked and are shown below: CAN_TxMsg and CAN_RxMsg. CanDemo.c writes to these to create the CAN messages and can be displayed in the Keil Watch window. The prototypes for functions used in Can.c are listed in Can.h in lines 31 to 47. These files are visible in Vision and the exact line numbers displayed can change with modifications to these files.
31 32 33 34 35 36 37 typedef struct { id; data[8]; len; format; type; // 29 bit identifier // Data field // Length of data field in bytes // 0 - STANDARD, 1- EXTENDED IDENTIFIER // 0 - DATA FRAME, 1 - REMOTE FRAME unsigned int unsigned char unsigned char unsigned char unsigned char } CAN_msg;
...
47 48 extern CAN_msg extern CAN_msg CAN_TxMsg[2]; CAN_RxMsg[2]; // CAN message for sending // CAN message for receiving
www.keil.com
2) Can.c
Configuring the CAN Controller: (Can.C) There are several things that must be done to properly configure the two CAN controllers. These are done in Can.C by functions that are called by CanDemo.c. Examples are found in the function CAN_setup (lines 92 to 121): 1. Enable and set the clock for each CAN controller. TIP: The clock must be stable for CAN. No R-C oscillators ! 2. Enable the interrupts for the transmit and receive functions for each controller. 3. Set BTR: This is a 32 CAN controller register where things such as bit timing, bus frequency, sample point and silent and loop back modes are set. In the Keil example, the baudrate is set to 500 Kbps (bits per second). This is actually configured in the function CAN_cfgBaudrate starting at line 64. TIP: Sometimes timing settings can cause strange problems. If you experience some unusual problems you might want to study CAN timing in greater detail. For small systems, the default settings or those suggested by the processor manufacturer will work satisfactorily. You can adjust these settings for the most robust bus performance. All CAN controllers have the same general settings for bit timing because of the licensing agreements with Robert Bosch GmbH. For a detailed explanation of CAN bit timing see www.port.de/pdf/CAN_Bit_Timing.pdf and for the calculations see the LPC2300 Users Manual. TIP: All CAN controllers on a network should have consistent BTR values for stable operation. Other Functions in Can.c: CAN_start: Starts the CAN controller by ending the initialization sequence. CAN_waitReady: Checks if transmit mailbox is ready then sets global CAN_TxRdy to 1. CAN_wrMsg: Write a message to the CAN controller and transmit it. CAN_rdMsg: Read a message from the CAN controller and releases it to be sent to the LPC2300 CPU. CAN_wrFilter: Configure the acceptance filter. This is not discussed in this article. See NXP AN10674. CAN_ISR: The interrupt handler for both transmit and receive.
3) CanDemo.c
This contains the main function and contains the example program that reads the pot voltage with the A/D converter and sends its value as a CAN data byte with an 11 bit ID of 0x21. CanDemo.c contains functions to configure and read the A/D converter, display the A/D values on the LCD and call the functions that initialize the CAN controller. Transmitting a CAN Message: Lines 127 to 131 puts the frame values into the structure CAN_TxMsg[1] that refers to CAN controller 2. (Except for the data byte from the A/D converter.) Remember these line numbers can change slightly.
127 128 129 130 131 CAN_TxMsg[1].id = 33; CAN_TxMsg[1].len = 1; CAN_TxMsg[1].format = STANDARD_FORMAT; CAN_TxMsg[1].type = DATA_FRAME; /* initialise message to send */
This CAN message will send one data byte. For example, if you change the value in the member CAN_TxMsg.len to 3, three data bytes will be sent on the bus. What data will be in them depends on the contents of the array CAN_TxMsg.data. TIP: If you send more data bytes than you have data, it is a good idea to fill the empty data bytes with either 0 or 0xFF. Lines 138 puts the A/D value into the data member CAN_TxMsg[1].data[0] in data byte 0 and line 139 transmits it.
138 139 CAN_TxMsg[1].data[0] = val_Tx; CAN_wrMsg (2, &CAN_TxMsg[1]); /* data[0] field = ADC value */ /* transmit message */
10 10
www.keil.com
Receiving a CAN Message: Lines 144 and 145 indicate when a CAN message is received. But something more must be going on here. Line 147 shows that the data byte received and inserted in the array[0] is sent to be displayed on the LCD. How exactly does the CAN data byte get into the member array CAN_RxMsg[0].data[0] ?
144 145 147 } if (CAN_RxRdy[0]) { CAN_RxRdy[0] = 0; val_Rx = CAN_RxMsg[0].data[0]; /* rc message on CAN Controller #1 */
Using The Keil Simulator to illustrate: Recall we said before that the function to read the CAN data was located in Can.c. If we look in Can.c, we find the function CAN_rdMsg at lines 167 to 183. Examining it, clearly it is here that the array[0] is indeed loaded here at line 180. But how does this function get called ? It is not called from CanDemo.c. If we set a breakpoint on Can.c line 167 (refer to the illustration) by double-clicking on the left side of Line 167, we can check the Call Stack window to see where it was called from and is also shown. Click on CAN loopback ON in the ToolBox dialog box and click on RUN. The result shown in the Call Stack window indicates that the function CAN_ISR at Line 323 in CAN.C called CAN_rdMsg. TIP: If the program never stops make sure you turned the loopback ON. We can use the Trace function of Vision that is available in Simulator mode to illustrate how CAN_rdMsg is called. 1. Click on Enable Trace Recording icon. 2. Run the program to the breakpoint set previously at Line 167. View the Disassembly 3. Click on View Trace Records. window that opens up as shown below. The yellow arrow points to the start of the function CAN_rdMsg and represents the program counter. This instruction is not executed yet. The grey area shows a recorded history of executed instructions in the order they were executed. The white area displays unexecuted instructions. The assembly source line 338: (from LPC2300.s) loads the PC with the address of CAN_ISR at time -11 which in turn calls CAN_ rdMsg at time -5. The assembly instructions at time -12 and above is a loop in function delay in CanDemo.c. If you right click on any line and select Show Source at Current Line, this will be displayed in the source file.
TIP: This demonstrates trace recording with the Keil simulator. The LPC2300 series also features ETM trace. TIP: If you have more than one CAN controller in your processor you can operate these as parallel receivers. Divide the messages up with the Acceptance Filters. This will help capture all the messages on a very busy bus without losing any. Each CAN controller will handle its share of the messages. This effectively multiplies the number of FIFO buffer memories which is an excellent method of capturing all the CAN frames. 11 11
www.keil.com
The Keil CAN Demonstration Software: How it works(with the Keil MCB2300 board)
You will need a Keil ULINK2 or ULINK-ME USB to JTAG adapter to run the example program on a MCB2300 board. Since this example uses only internal memory: any LPC2300 board with CAN transceiver chips installed will work. Attach a network cable as shown joining pins 2 and 7 from one DB9 connector to the other. No termination resistors are needed. 1. Start Vision by clicking on its icon on your Desktop.
2. Select Project/Open Project. Open the file C:\Keil\ARM\Boards\Keil\MCB2300\CAN\CAN.Uv2. 3. Make sure MCB2300 is selected in the Target window. 4. Compile the source files by clicking on the Build icon. 5. Click on the Options for Target icon. . They will compile with no errors or warnings.
Select the Debug tab and select Use ULINK ARM Debugger.
6. Click on Settings and you can confirm an ARM7TDMI-S processor is connected to the debugger. 7. Click on the Load icon to program the LPC2300 Flash memory. The loader status is indicated in Vision. Select OK when the Evaluation Mode box appears.
9. Open Peripherals/CAN/CAN Controller 1 & 2 and position as appropriate. 10. Click on the RUN icon and rotate the blue pot. Note: you can stop the program with the STOP icon.
11. Note CAN message data appears in the LCD. TIP: If only the Tx changes as you rotate the pot: there is something wrong with the CAN network cable. You should see both the transmit and receive frames. 12. In CAN Controller 2 window Tx1 ID and DATA will be displayed the transmit data. In CAN Controller 2 the received data will be displayed in Rx ID & Data. Clearly the ID is 0x21 in this example and is 11 bits long. 13.
12 12
www.keil.com
The ETM pins on the LPC2300 are shared with the CAN ports and GPIO P2. This means that ETM cant be used when CAN is operating. If you need to use ETM with the LPC2300 you could install an external NXP CAN controller or use a NXP LPC1700 series part. The LPC1700 is a Cortex-M3 and has both ETM and Serial Wire Viewer. The Serial Wire Viewer can provide PC samples, exceptions and data operations with CAN. See the LPC1700 version of this document. ETM is an extremely valuable tool if the LPC2300 CAN controller is not used. It is mentioned here for completeness.
www.keil.com
14 14
www.keil.com