This document summarizes the results of a steel design report checking the design of member 3 (a rafter) against Eurocode 3 standards. It provides the section dimensions and material properties, performs section classification and capacity checks for various limit states including bending, shear, buckling and deflection. The member was found to meet all design limits under the given loading conditions.

Uploaded by

scribd_namn
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
224 views

EC3 Example Report

This document summarizes the results of a steel design report checking the design of member 3 (a rafter) against Eurocode 3 standards. It provides the section dimensions and material properties, performs section classification and capacity checks for various limit states including bending, shear, buckling and deflection. The member was found to meet all design limits under the given loading conditions.

Uploaded by

scribd_namn
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 10

Steel Design Report

Checking C:\Users\jake.FDS\Desktop\EC3 example.mfd to Eurocode 3 code


Monday, 11 April 2011 4:15 PM

Checking design member 3 (Rafter)


Members: 3
Group: HEM Balk
Section: 600HEM

Section Dimensions
b = 305.0 mm, d = 486.0 mm, tf = 40.0 mm, tw = 21.0 mm, c = 152.5 mm, r = 27.0 mm

Material Properties
S 235 H
fy = 235.0 MPa, fu = 360.0 MPa
fyf = 235.0 MPa, fyw = 235.0 MPa
E = 210000.0 MPa, G = 81000.0 MPa

Section Properties
Ag = 36370.0 mm
Iy = 2374.0x106mm4, Wely = 8770.0x10mm, Wply = 7660.0x10mm, iy = 256.0 mm
Iz = 189.8x106mm4, Welz = 0.0x10mm, Wplz = 1240.0x10mm, iz = 72.2 mm
It = 15.7x106mm4, Iw = 15900.0x109mm6

Design Parameters
Tension Parameters
Compression Parameters
Lcy = 5.099 m, Lcz = 5.099 m
Shear Parameters
Stiffener Spacing, a = 0.0 mm
Bending Parameters
Lateral Restraints:
Position(m)
Span(m)
Top
Bottom Torsion
0.0 m
0.0 m
Lateral Lateral None
5.099 m
5.099 m
Lateral Lateral None
Primary Deflection Parameters
y L/250 mm
Secondary Deflection Parameters
y L/250 mm

Derived Section Properties


Net Section Area
Anet = Ag - AWeb Holes - AFlange Holes = 36370.0 - 0.0 - 0.0 = 36370.0 mm
Selection of Buckling Curve
h/b > 1.2, 620.0/305.0 > 1.2, 2.033 > 1.2 and tf 40, 40.0 40
Buckling curve for buckling about y-y axis is a
Buckling curve for buckling about z-z axis is b

Load Case: Load Case 1 (Linear) (Serviceability Limit State)


Deflection Checks
Design Member 3, Load Case 1 (Linear), Primary Deflection
Major axis deflection, L/250, 10.495 20.396 mm

OK 49% under

Design Member 3, Load Case 1 (Linear), Secondary Deflection


Major axis deflection, L/250, 10.495 20.396 mm

OK 49% under

Load Case: Load Case 1 (Linear) (Strength Limit State)


Design Actions
My = 781.153 kN-m, Mz = 0.0 kN-m, Tx = 0.0 kN-m, Vy = 222.792 kN, Vz = 0.0 kN, Nt = 0.0 kN, Nc = 160.794 kN

Effective Section Area


= 2/1 = 102.004/-102.004 = -1.0
Flanges
Outstand: < 0, -1.0 < 0 k = 1.7 - 5 + 17.12 = 1.7 - 5*-1.0 + 17.1*-1.02 = 23.8
p = (c/t)/(28.4(k)) = (152.5/40.0)/(28.4*1.0(23.8)) = 0.028
p 0.673, 0.028 0.673 = 1
< 0, -1.0 < 0 ceff = c/(1 - ) = 1.0*152.5/(1 - -1.0) = 76.25 mm
Web
Internal: k = 16/[((1+)2 + 0.112(1-)2)0.5 + (1+)] = 16/[((1+-1.0)2 + 0.112(1--1.0)2)0.5 + (1+-1.0)] = 23.905
p = (d/t)/(28.4(k)) = (486.0/21.0)/(28.4*1.0(23.905)) = 0.167
p 0.673, 0.167 0.673 = 1

< 0, -1.0 < 0 deff = d/(1 - ) = 1.0*486.0/(1 - -1.0) = 243.0 mm


Aeff = 4cefftf + defftw = 4*76.25*40.0 + 243.0*21.0 = 17303.0 mm

Section Classification
d = 486.0 mm, tw = 21.0 mm, c = 152.5 mm, tf = 40.0 mm, = 1.0
Web
When 0.5:
d/tw 36/, 486.0/21.0 36*1.0/0.5, 23.143 72.0
Web is Class 1
Flange
c/tf 9/, 152.5/40.0 9*1.0/1.0, 3.813 10.0 Flange Class is 1
Section is Class 1

Column Segments
Segments
Finding segments
Restraint #1
Full restraint at critical flange
Restraint #2
Full restraint at critical flange
Full or Partial restraint forms segment
Summary of segments
Segment #1
Start = 0.000, Length = 5.099, Restraint Arrangement: FF
Mmax = 781.153 kN-m, MA = 497.148 kN-m, MB = 213.142 kN-m, MC = 70.863 kN-m, Rm = 1.0

Tensile Capacity
Plastic resistance of the gross section
Npl,Rd = Afy/M0 = 36370.0*235.0/1.0 = 8546.95 kN
Ultimate resistance of the gross section
Nu,Rd = 0.9Anetfu/M2 = 0.9*36370.002*360.0/1.1 = 10712.619 kN

Compressive Capacity
Nc,Rd = Afy/M0 = 36370.0*235.0/1.0 = 8546.95 kN

Moment Capacity about Major Principal Axis


Mc,y,Rd = Mpl,y,Rd = Wy,plfy/M0 = 7660.0*235.0/1.0 = 1800.1 kN-m

Moment Capacity about Minor Principal Axis


Mc,z,Rd = Mpl,z,Rd = Wz,plfy/M0 = 1240.0*235.0/1.0 = 291.4 kN-m

Major-Axis Shear capacity:


For steel grades up to and including S460, = 1.20
Av = A - 2btf + (tw + 2r)tf = 36370.0 - 2*305.0*40.0 + (21.0 + 2*27.0)*40.0 = 14970.0 mm
Vpl,y,Rd = Vpl,y,Rd = Av(fy/3)/M0 = 14970.0*(235.0/3)/1.0 = 2031.089 kN

Minor-Axis Shear capacity:


For steel grades up to and including S460, = 1.20
Av = A - (hwtw) = 36370.0 - 486.0*21.0 = 26164.0 mm
Vpl,z,Rd = Vpl,z,Rd = Av(fy/3)/M0 = 26164.0*(235.0/3)/1.0 = 3549.861 kN

Torsion capacity:
y = fy/3 = 235.0/3 = 135.677 MPa

Tt = [2(btf2/2) + (dtw2/2)]y = [2*(305.0*40.02/2) + (486.0*21.02/2)]*135.677 = 80.75 kN-m

Bimoment section resistance:


df = h - tf = 620.0 - 40.0 = 580.0 mm
BRd = fydfbf2tf/4 = 235.0*580.0*305.02*40.0/4 = 126.793 kN-m

Major-Axis Bending and Shear capacity:


VEd 0.5Vpl,Rd, 222.792 0.5*2031.089, 222.792 1015.545 = 0
fy = (1 - )fy = (1 - 0.0)*235.0 = 235.0 MPa

Mc,y,Rd = Mpl,y,Rd = Wy,plfy/M0 = 7660.0*235.0/1.0 = 1800.1 kN-m

Minor-Axis Bending and Shear capacity:


VEd 0.5Vpl,Rd, 0.0 0.5*3549.861, 0.0 1774.931 = 0
fy = (1 - )fy = (1 - 0.0)*235.0 = 235.0 MPa
Mc,z,Rd = Mpl,z,Rd = Wz,plfy/M0 = 1240.0*235.0/1.0 = 291.4 kN-m

Biaxial Bending and Axial Load capacity:


n = NEd/Npl,Rd = 160.794/8546.95 = 0.019

NEd 0.25Npl,Rd and NEd 0.5hwtwfy/M0, 160.794 2136.738 and 160.794 1529.85 MN,y,Rd = Mpl,y,Rd = 1800.1 kN-m
NEd hwtwfy/M0, 160.794 620.0*21.0*235.0/1.0, 160.794 3059.7 MN,y,Rd = Mpl,y,Rd = 1800.1 kN-m

Biaxial Bending, Shear and Axial Load capacity:


VEd 0.5Vpl,Rd, 222.792 0.5*2031.089, 222.792 1015.545 = 0
fy = (1 - )fy = (1 - 0.0)*235.0 = 235.0 MPa
n = NEd/Npl,Rd = 160.794/8546.95 = 0.019
NEd 0.25Npl,Rd and NEd 0.5hwtwfy/M0, 160.794 2136.738 and 160.794 1529.85 MN,y,Rd = Mpl,y,Rd = 1800.1 kN-m
NEd hwtwfy/M0, 160.794 620.0*21.0*235.0/1.0, 160.794 3059.7 MN,y,Rd = Mpl,y,Rd = 1800.1 kN-m

Major Axis Compressive Buckling capacity:


Beam-column is pinned-pinned kcr = 1.0
Lcr = kcrL = 1.0*5099.02 = 5099.02 mm

fy = 235.0 MPa, A = 36370.0 mm, Lcr = 5099.02 mm, i = 256.0 mm, = 1.0
1 = (E/fy) = 93.3 = 93.3*1.0 = 93.9

For Class 1, 2 and 3 cross-sections, = Lcr/i 1/1 = 5099.02/256.0 * 1/93.9 = 0.212


Ncr,y = Afy/2 = 36370.0*235.0/0.2122 = 189954.212 kN

For Buckling Curve a, = 0.21


= 0.5[1 + ( - 0.2) + 2] = 0.5*[1 + 0.21*(0.212 - 0.2) + 0.2122] = 0.524
= 1/( + (2 - 2)) = 1/(0.524 + (0.5242 - 0.2122)) = 0.997
ip = [(Iy + Iz)/A] = [(2374.0 + 189.8)/36370.0] = 265.504 mm
i02 = ip2 + y02 + z02 = 265.5042 + 0.02 + 0.02 = 70492.164 mm
Ncr,TF = 1/i02(GIt + 2EIw/Lcr,T2) = 1/70492.164*(81000.0*15.7 + 2*210000.0*15.9/5099.022) = 36020.812 kN
NEd/Ncr 0.04, 160.794/189954.212 0.04, 0.001 0.04 the buckling effects may be ignored
Ny,b,Rd = Nc,Rd = 8546.95 kN

Minor Axis Compressive Buckling capacity:


Beam-column is pinned-pinned kcr = 1.0
Lcr = kcrL = 1.0*5099.02 = 5099.02 mm

fy = 235.0 MPa, A = 36370.0 mm, Lcr = 5099.02 mm, i = 72.2 mm, = 1.0
1 = (E/fy) = 93.3 = 93.3*1.0 = 93.9

For Class 1, 2 and 3 cross-sections, = Lcr/i 1/1 = 5099.02/72.2 * 1/93.9 = 0.752


Ncr,z = Afy/2 = 36370.0*235.0/0.7522 = 15109.267 kN

For Buckling Curve b, = 0.34


= 0.5[1 + ( - 0.2) + 2] = 0.5*[1 + 0.34*(0.752 - 0.2) + 0.7522] = 0.877
= 1/( + (2 - 2)) = 1/(0.877 + (0.8772 - 0.7522)) = 0.753
ip = [(Iy + Iz)/A] = [(2374.0 + 189.8)/36370.0] = 265.504 mm
i02 = ip2 + y02 + z02 = 265.5042 + 0.02 + 0.02 = 70492.164 mm
Ncr,TF = 1/i02(GIt + 2EIw/Lcr,T2) = 1/70492.164*(81000.0*15.7 + 2*210000.0*15.9/5099.022) = 36020.812 kN
NEd/Ncr 0.04, 160.794/15109.267 0.04, 0.011 0.04 the buckling effects may be ignored
Nz,b,Rd = Nc,Rd = 8546.95 kN

Lateral Torsional Buckling capacity:


Beam-column is pinned-pinned kcr = 1.0
Lcr = kcrL = 1.0*5099.02 = 5099.02 mm
M1 = -781.153 kN-m, M2 = 354.869 kN-m m = M1/M2 = -781.153/354.869 = -2.201
m = 1.75 + 1.05m + 0.3m2 = 1.75 + 1.05*-2.201 + 0.3*-2.2012 = 0.892
For Class 1 or 2 cross-sections Wy = Wpl,y = 7660.0x10mm
For Rolled I-sections with h/b > 0.2, 620.0/305.0 > 0.2, 2.033 > 0.2 use Buckling Curve c LT = 0.49
LT,0 = 0.4
= 0.75
Mcr = m[(2EIz/Lcr2)(GIt + 2EIw/Lcr2)] = 5530.912 kN-m
LT = (Wyfy/Mcr) = (7660.0*235.0/5530.912) = 0.57

MEd/Mcr LT,02, 781.153/5530.912 0.42, 0.141 0.16 the buckling effects may be ignored and LT = 1.0
Mb,Rd = Mc,Rd = 1800.1 kN-m

Member Capacity Summary


Nt,Rd = min(Npl,Rd, Nu,Rd) = min(8546.95, 10712.619) = 8546.95 kN
Nc,Rd = 8546.95 kN
My,c,Rd = 1800.1 kN-m
Mz,c,Rd = 291.4 kN-m
Vy,c,Rd = 2031.089 kN
Vz,c,Rd = 3549.861 kN
Tt,Rd = 80.75 kN-m
BRd = 126.793 kN-m
My,V,Rd = 1800.1 kN-m
Mz,V,Rd = 291.4 kN-m
My,N,Rd = 1800.1 kN-m
Mz,N,Rd = 291.4 kN-m
My,NV,Rd = 1800.1 kN-m
Mz,NV,Rd = 291.4 kN-m
Nb,Rd = min(Ny,b,Rd, Nz,b,Rd) = min(8546.95, 8546.95) = 8546.95 kN
Mb,Rd = 1800.1 kN-m

Design Checks
Design Member 3, Load Case 1 (Linear), Tension
NEd/Nt,Rd 1.0, 0.0/8546.95 1.0, 0.0 1.0

OK 100% under

Design Member 3, Load Case 1 (Linear), Compression


NEd/Nc,Rd 1.0, 160.794/8546.95 1.0, 0.019 1.0

OK 98% under

Design Member 3, Load Case 1 (Linear), Bending (Major Axis)


My,Ed/My,c,Rd 1.0, 781.153/1800.1 1.0, 0.434 1.0

OK 57% under

Design Member 3, Load Case 1 (Linear), Bending (Minor Axis)


Mz,Ed/Mz,c,Rd 1.0, 0.0/291.4 1.0, 0.0 1.0

OK 100% under

Design Member 3, Load Case 1 (Linear), Shear (Major Axis)


Vy,Ed/Vy,c,Rd 1.0, 222.792/2031.089 1.0, 0.11 1.0

OK 89% under

Design Member 3, Load Case 1 (Linear), Shear (Minor Axis)


Vz,Ed/Vz,c,Rd 1.0, 0.0/3549.861 1.0, 0.0 1.0

OK 100% under

Design Member 3, Load Case 1 (Linear), Bending + Shear (Major Axis)


My,Ed/My,V,Rd 1.0, 781.153/1800.1 1.0, 0.434 1.0

OK 57% under

Design Member 3, Load Case 1 (Linear), Bending + Shear (Minor Axis)


My,Ed/My,V,Rd 1.0, 0.0/291.4 1.0, 0.0 1.0

OK 100% under

Design Member 3, Load Case 1 (Linear), Biaxial Bending + Axial Force


Check 1:
My,Ed MN,y,Rd, 781.153 1800.1 OK 57% under
Check 2:
My,Ed MN,y,Rd, 0.0 291.4

OK 100% under

Check 3:
= 2; 5n < 1, 5*0.019 < 1, 0.094 < 1 = 1

[My,Ed/My,N,Rd]&a + [Mz,Ed/Mz,N,Rd] 1, [781.153/1800.1]2.0 + [0.0/291.4]1.0 1, 0.188 1

OK 81% under

Design Member 3, Load Case 1 (Linear), Biaxial Bending + Shear + Axial Force
Check 1:
My,Ed MN,y,Rd, 781.153 1800.1 OK 57% under
Check 2:
My,Ed MN,y,Rd, 0.0 291.4

OK 100% under

Check 3:
= 2; 5n < 1, 5*-1.#QO < 1, -1.#QO < 1 = 1
[My,Ed/My,N,Rd]&a + [Mz,Ed/Mz,N,Rd] 1, [781.153/1800.1]2.0 + [0.0/291.4]1.0 1, 0.188 1

OK 81% under

Design Member 3, Load Case 1 (Linear), Torsion


(Tt,Ed/Tt,Rd)2 + (BEd/BRd)2 1.0, (0.0/80.75)2 + (0.0/126.793)2 1.0, 0.0 1.0 OK 100% under

Design Member 3, Load Case 1 (Linear), Compression Buckling


NEd/Nb.Rd 1.0, 160.794/8546.95 1.0, 0.019 1.0

OK 98% under

Design Member 3, Load Case 1 (Linear), Lateral Torsional Buckling


MEd/Mb,Rd 1.0, 0.0/1800.1 1.0, 0.0 1.0

OK 100% under

Design Member 3, Load Case 1 (Linear), Biaxial Bending + Compression Buckling


y = 0.997, z = 0.753, LT = 1.0
For Class 1 and 2 cross-sections:
Ai = A = 36370.0 mm
Wy = Wpl,y = 7660.0x10mm and Wz = Wpl,z = 1240.0x10mm
My.Ed = 0 and Mz.Ed = 0

NRk = fyAi = 235.0*36370.0 = 8546.95 kN


My,Rk = fyWy = 235.0*7660.0 = 1800.1 kN-m
Mz,Rk = fyWz = 235.0*1240.0 = 291.4 kN-m
Calculate Cmy

= Me/Mh = 354.869/-781.153 = -0.454

Mh/Ms > 1.0, -781.153/-213.142 > 1.0, 3.665 > 1.0 h = 1.0
Cmy = 0.90 + 0.10h = 0.90 + 0.10*1.0 = 1.0
Calculate Cmz

= Me/Mh = 0.0/0.0 = 0.0

h = Mh/Ms = 0.0/0.0 = 0.0


Cmz = 0.90 + 0.10h = 0.90 + 0.10*0.0 = 0.9
Calculate CmLT

= Me/Mh = 354.869/-781.153 = -0.454

Mh/Ms > 1.0, -781.153/-213.142 > 1.0, 3.665 > 1.0 h = 1.0
CmLT = 0.90 + 0.10h = 0.90 + 0.10*1.0 = 1.0
kyy = Cmy(1 + (y - 0.2)NEd/(yNRk/M1)) = 1.0*(1 + (0.212 - 0.2)*160.794/(0.997*8546.95/1.0)) = 1.0
kzz = Cmz(1 + (2z - 0.6)NEd/(zNRk/M1)) = 0.9*(1 + (2*0.752 - 0.6)*160.794/(0.753*8546.95/1.0)) = 1.033
kyz = 0.6kzz = 0.6*1.033 = 0.62
kzy = 0.6kyy = 0.6*1.0 = 0.6
Check 1:
NEd/(yNRk)/M1 + kyy(My,Ed + My,Ed)/(LTMy,Rk)/M1 + kyz(Mz,Ed + Mz,Ed)/My,Rk/M1 1.0, 0.453 1.0

OK 55% under

Check 2:
NEd/(zNRk)/M1 + kzy(My,Ed + My,Ed)/(LTMy,Rk)/M1 + kzz(Mz,Ed + Mz,Ed)/My,Rk/M1 1.0, 0.285 1.0

OK 71% under

Checking design member 4 (Column)


Members: 4
Group: HEM Balk
Section: 340HEM

Section Dimensions
b = 309.0 mm, d = 243.0 mm, tf = 40.0 mm, tw = 21.0 mm, c = 154.5 mm, r = 27.0 mm

Material Properties
S 235 H
fy = 235.0 MPa, fu = 360.0 MPa
fyf = 235.0 MPa, fyw = 235.0 MPa
E = 210000.0 MPa, G = 81000.0 MPa

Section Properties
Ag = 31580.0 mm
Iy = 763.7x106mm4, Wely = 4720.0x10mm, Wply = 4050.0x10mm, iy = 156.0 mm
Iz = 197.1x106mm4, Welz = 0.0x10mm, Wplz = 1280.0x10mm, iz = 79.0 mm
It = 15.1x106mm4, Iw = 5580.0x109mm6

Design Parameters
Tension Parameters
Compression Parameters
Lcy = 5.0 m, Lcz = 5.0 m
Shear Parameters
Stiffener Spacing, a = 0.0 mm
Bending Parameters
Lateral Restraints:
Position(m)
Span(m) Top
Bottom
0.0 m 0.0 m
Lateral Lateral None
5.0 m 5.0 m
Lateral Lateral None
Primary Deflection Parameters
y L/250 mm

Torsion

Secondary Deflection Parameters


y L/250 mm

Derived Section Properties


Net Section Area
Anet = Ag - AWeb Holes - AFlange Holes = 31580.0 - 0.0 - 0.0 = 31580.0 mm
Selection of Buckling Curve
h/b > 1.2, 377.0/309.0 > 1.2, 1.22 > 1.2 and tf 40, 40.0 40
Buckling curve for buckling about y-y axis is a
Buckling curve for buckling about z-z axis is b

Load Case: Load Case 1 (Linear) (Serviceability Limit State)


Deflection Checks
Design Member 4, Load Case 1 (Linear), Primary Deflection
Major axis deflection, L/250, 3.181 20.0 mm

OK 84% under

Design Member 4, Load Case 1 (Linear), Secondary Deflection


Major axis deflection, L/250, 3.181 20.0 mm

OK 84% under

Load Case: Load Case 1 (Linear) (Strength Limit State)


Design Actions
My = 354.869 kN-m, Mz = 0.0 kN-m, Tx = 0.0 kN-m, Vy = 113.978 kN, Vz = 0.0 kN, Nt = 0.0 kN, Nc = 250.0 kN

Effective Section Area


= 2/1 = 87.59/87.59 = 1.0
Flanges
Outstand: 0, 1.0 0 k = 0.578/(+0.34) = 0.578/(1.0+0.34) = 0.431
p = (c/t)/(28.4(k)) = (154.5/40.0)/(28.4*1.0(0.431)) = 0.207
p 0.673, 0.207 0.673 = 1

0, 1.0 0 ceff = c = 1.0*154.5 = 154.5 mm


Web
Internal: k = 16/[((1+)2 + 0.112(1-)2)0.5 + (1+)] = 16/[((1+1.0)2 + 0.112(1-1.0)2)0.5 + (1+1.0)] = 4.0
p = (d/t)/(28.4(k)) = (243.0/21.0)/(28.4*1.0(4.0)) = 0.204
p 0.673, 0.204 0.673 = 1
0, 1.0 0 deff = d = 1.0*243.0 = 243.0 mm
Aeff = 4cefftf + defftw = 4*154.5*40.0 + 243.0*21.0 = 29823.0 mm

Section Classification

d = 243.0 mm, tw = 21.0 mm, c = 154.5 mm, tf = 40.0 mm, = 1.0


Web
When 0.5:
d/tw 36/, 243.0/21.0 36*1.0/0.5, 11.571 72.0
Web is Class 1
Flange
c/tf 9/, 154.5/40.0 9*1.0/1.0, 3.862 10.0 Flange Class is 1
Section is Class 1

Column Segments
Segments
Finding segments
Restraint #1
Full restraint at critical flange
Restraint #2
Full restraint at critical flange
Full or Partial restraint forms segment
Summary of segments
Segment #1
Start = 0.000, Length = 5.000, Restraint Arrangement: FF
Mmax = 354.869 kN-m, MA = 72.548 kN-m, MB = 69.924 kN-m, MC = 212.397 kN-m, Rm = 1.0

Tensile Capacity
Plastic resistance of the gross section
Npl,Rd = Afy/M0 = 31580.0*235.0/1.0 = 7421.3 kN
Ultimate resistance of the gross section
Nu,Rd = 0.9Anetfu/M2 = 0.9*31580.001*360.0/1.1 = 9301.746 kN

Compressive Capacity
Nc,Rd = Afy/M0 = 31580.0*235.0/1.0 = 7421.3 kN

Moment Capacity about Major Principal Axis


Mc,y,Rd = Mpl,y,Rd = Wy,plfy/M0 = 4050.0*235.0/1.0 = 951.75 kN-m

Moment Capacity about Minor Principal Axis


Mc,z,Rd = Mpl,z,Rd = Wz,plfy/M0 = 1280.0*235.0/1.0 = 300.8 kN-m

Major-Axis Shear capacity:


For steel grades up to and including S460, = 1.20
Av = A - 2btf + (tw + 2r)tf = 31580.0 - 2*309.0*40.0 + (21.0 + 2*27.0)*40.0 = 9860.0 mm
Vpl,y,Rd = Vpl,y,Rd = Av(fy/3)/M0 = 9860.0*(235.0/3)/1.0 = 1337.778 kN

Minor-Axis Shear capacity:


For steel grades up to and including S460, = 1.20
Av = A - (hwtw) = 31580.0 - 243.0*21.0 = 26477.0 mm
Vpl,z,Rd = Vpl,z,Rd = Av(fy/3)/M0 = 26477.0*(235.0/3)/1.0 = 3592.328 kN

Torsion capacity:
y = fy/3 = 235.0/3 = 135.677 MPa
Tt = [2(btf2/2) + (dtw2/2)]y = [2*(309.0*40.02/2) + (243.0*21.02/2)]*135.677 = 74.349 kN-m

Bimoment section resistance:


df = h - tf = 377.0 - 40.0 = 337.0 mm
BRd = fydfbf2tf/4 = 235.0*337.0*309.02*40.0/4 = 75.616 kN-m

Major-Axis Bending and Shear capacity:


VEd 0.5Vpl,Rd, 113.978 0.5*1337.778, 113.978 668.889 = 0
fy = (1 - )fy = (1 - 0.0)*235.0 = 235.0 MPa
Mc,y,Rd = Mpl,y,Rd = Wy,plfy/M0 = 4050.0*235.0/1.0 = 951.75 kN-m

Minor-Axis Bending and Shear capacity:


VEd 0.5Vpl,Rd, 0.0 0.5*3592.328, 0.0 1796.164 = 0
fy = (1 - )fy = (1 - 0.0)*235.0 = 235.0 MPa

Mc,z,Rd = Mpl,z,Rd = Wz,plfy/M0 = 1280.0*235.0/1.0 = 300.8 kN-m

Biaxial Bending and Axial Load capacity:


n = NEd/Npl,Rd = 250.0/7421.3 = 0.034
NEd 0.25Npl,Rd and NEd 0.5hwtwfy/M0, 250.0 1855.325 and 250.0 930.248 MN,y,Rd = Mpl,y,Rd = 951.75 kN-m
NEd hwtwfy/M0, 250.0

377.0*21.0*235.0/1.0, 250.0 1860.495 MN,y,Rd = Mpl,y,Rd = 951.75 kN-m

Biaxial Bending, Shear and Axial Load capacity:

VEd 0.5Vpl,Rd, 113.978 0.5*1337.778, 113.978 668.889 = 0


fy = (1 - )fy = (1 - 0.0)*235.0 = 235.0 MPa
n = NEd/Npl,Rd = 250.0/7421.3 = 0.034

NEd 0.25Npl,Rd and NEd 0.5hwtwfy/M0, 250.0 1855.325 and 250.0 930.248 MN,y,Rd = Mpl,y,Rd = 951.75 kN-m
NEd hwtwfy/M0, 250.0

377.0*21.0*235.0/1.0, 250.0 1860.495 MN,y,Rd = Mpl,y,Rd = 951.75 kN-m

Major Axis Compressive Buckling capacity:


Beam-column is pinned-fixed kcr = 0.7
Lcr = kcrL = 0.7*5000.0 = 3500.0 mm
fy = 235.0 MPa, A = 31580.0 mm, Lcr = 3500.0 mm, i = 156.0 mm, = 1.0
1 = (E/fy) = 93.3 = 93.3*1.0 = 93.9
For Class 1, 2 and 3 cross-sections, = Lcr/i 1/1 = 3500.0/156.0 * 1/93.9 = 0.239
Ncr,y = Afy/2 = 31580.0*235.0/0.2392 = 129994.291 kN
For Buckling Curve a, = 0.21
= 0.5[1 + ( - 0.2) + 2] = 0.5*[1 + 0.21*(0.239 - 0.2) + 0.2392] = 0.533
= 1/( + (2 - 2)) = 1/(0.533 + (0.5332 - 0.2392)) = 0.991
ip = [(Iy + Iz)/A] = [(763.7 + 197.1)/31580.0] = 174.426 mm
i02 = ip2 + y02 + z02 = 174.4262 + 0.02 + 0.02 = 30424.319 mm
Ncr,TF = 1/i02(GIt + 2EIw/Lcr,T2) = 1/30424.319*(81000.0*15.1 + 2*210000.0*5.58/3500.02) = 71232.429 kN
NEd/Ncr 0.04, 250.0/129994.291 0.04, 0.002 0.04 the buckling effects may be ignored
Ny,b,Rd = Nc,Rd = 7421.3 kN

Minor Axis Compressive Buckling capacity:


Beam-column is pinned-fixed kcr = 0.7
Lcr = kcrL = 0.7*5000.0 = 3500.0 mm
fy = 235.0 MPa, A = 31580.0 mm, Lcr = 3500.0 mm, i = 79.0 mm, = 1.0
1 = (E/fy) = 93.3 = 93.3*1.0 = 93.9
For Class 1, 2 and 3 cross-sections, = Lcr/i 1/1 = 3500.0/79.0 * 1/93.9 = 0.472
Ncr,z = Afy/2 = 31580.0*235.0/0.4722 = 33337.211 kN
For Buckling Curve b, = 0.34
= 0.5[1 + ( - 0.2) + 2] = 0.5*[1 + 0.34*(0.472 - 0.2) + 0.4722] = 0.658
= 1/( + (2 - 2)) = 1/(0.658 + (0.6582 - 0.4722)) = 0.896
ip = [(Iy + Iz)/A] = [(763.7 + 197.1)/31580.0] = 174.426 mm
i02 = ip2 + y02 + z02 = 174.4262 + 0.02 + 0.02 = 30424.319 mm
Ncr,TF = 1/i02(GIt + 2EIw/Lcr,T2) = 1/30424.319*(81000.0*15.1 + 2*210000.0*5.58/3500.02) = 71232.429 kN
NEd/Ncr 0.04, 250.0/33337.211 0.04, 0.007 0.04 the buckling effects may be ignored
Nz,b,Rd = Nc,Rd = 7421.3 kN

Lateral Torsional Buckling capacity:


Beam-column is pinned-fixed kcr = 0.7
Lcr = kcrL = 0.7*5000.0 = 3500.0 mm
M1 = 215.02 kN-m, M2 = -354.869 kN-m m = M1/M2 = 215.02/-354.869 = -0.606
m = 1.75 + 1.05m + 0.3m2 = 1.75 + 1.05*-0.606 + 0.3*-0.6062 = 1.224
For Class 1 or 2 cross-sections Wy = Wpl,y = 4050.0x10mm
For Rolled I-sections with h/b > 0.2, 377.0/309.0 > 0.2, 1.22 > 0.2 use Buckling Curve c LT = 0.49
LT,0 = 0.4
= 0.75
Mcr = m[(2EIz/Lcr2)(GIt + 2EIw/Lcr2)] = 10404.96 kN-m
LT = (Wyfy/Mcr) = (4050.0*235.0/10404.96) = 0.302

LT LT,0, 0.302 0.4 the buckling effects may be ignored and LT = 1.0
Mb,Rd = Mc,Rd = 951.75 kN-m

Member Capacity Summary


Nt,Rd = min(Npl,Rd, Nu,Rd) = min(7421.3, 9301.746) = 7421.3 kN
Nc,Rd = 7421.3 kN
My,c,Rd = 951.75 kN-m

Mz,c,Rd = 300.8 kN-m


Vy,c,Rd = 1337.778 kN
Vz,c,Rd = 3592.328 kN
Tt,Rd = 74.349 kN-m
BRd = 75.616 kN-m
My,V,Rd = 951.75 kN-m
Mz,V,Rd = 300.8 kN-m
My,N,Rd = 951.75 kN-m
Mz,N,Rd = 300.8 kN-m
My,NV,Rd = 951.75 kN-m
Mz,NV,Rd = 300.8 kN-m
Nb,Rd = min(Ny,b,Rd, Nz,b,Rd) = min(7421.3, 7421.3) = 7421.3 kN
Mb,Rd = 951.75 kN-m

Design Checks
Design Member 4, Load Case 1 (Linear), Tension
NEd/Nt,Rd 1.0, 0.0/7421.3 1.0, 0.0 1.0

OK 100% under

Design Member 4, Load Case 1 (Linear), Compression


NEd/Nc,Rd 1.0, 250.0/7421.3 1.0, 0.034 1.0

OK 97% under

Design Member 4, Load Case 1 (Linear), Bending (Major Axis)


My,Ed/My,c,Rd 1.0, 354.869/951.75 1.0, 0.373 1.0

OK 63% under

Design Member 4, Load Case 1 (Linear), Bending (Minor Axis)


Mz,Ed/Mz,c,Rd 1.0, 0.0/300.8 1.0, 0.0 1.0

OK 100% under

Design Member 4, Load Case 1 (Linear), Shear (Major Axis)


Vy,Ed/Vy,c,Rd 1.0, 113.978/1337.778 1.0, 0.085 1.0

OK 91% under

Design Member 4, Load Case 1 (Linear), Shear (Minor Axis)


Vz,Ed/Vz,c,Rd 1.0, 0.0/3592.328 1.0, 0.0 1.0

OK 100% under

Design Member 4, Load Case 1 (Linear), Bending + Shear (Major Axis)


My,Ed/My,V,Rd 1.0, 354.869/951.75 1.0, 0.373 1.0

OK 63% under

Design Member 4, Load Case 1 (Linear), Bending + Shear (Minor Axis)


My,Ed/My,V,Rd 1.0, 0.0/300.8 1.0, 0.0 1.0

OK 100% under

Design Member 4, Load Case 1 (Linear), Biaxial Bending + Axial Force


Check 1:
My,Ed MN,y,Rd, 354.869 951.75 OK 63% under
Check 2:
My,Ed MN,y,Rd, 0.0 300.8

OK 100% under

Check 3:
= 2; 5n < 1, 5*0.034 < 1, 0.168 < 1 = 1
[My,Ed/My,N,Rd]&a + [Mz,Ed/Mz,N,Rd] 1, [354.869/951.75]2.0 + [0.0/300.8]1.0 1, 0.139 1

OK 86% under

Design Member 4, Load Case 1 (Linear), Biaxial Bending + Shear + Axial Force
Check 1:
My,Ed MN,y,Rd, 354.869 951.75 OK 63% under
Check 2:
My,Ed MN,y,Rd, 0.0 300.8

OK 100% under

Check 3:
= 2; 5n < 1, 5*-1.#QO < 1, -1.#QO < 1 = 1
[My,Ed/My,N,Rd]&a + [Mz,Ed/Mz,N,Rd] 1, [354.869/951.75]2.0 + [0.0/300.8]1.0 1, 0.139 1

Design Member 4, Load Case 1 (Linear), Torsion


(Tt,Ed/Tt,Rd)2 + (BEd/BRd)2 1.0, (0.0/74.349)2 + (0.0/75.616)2 1.0, 0.0 1.0 OK 100% under

Design Member 4, Load Case 1 (Linear), Compression Buckling


NEd/Nb.Rd 1.0, 250.0/7421.3 1.0, 0.034 1.0

OK 97% under

Design Member 4, Load Case 1 (Linear), Lateral Torsional Buckling


MEd/Mb,Rd 1.0, 0.0/951.75 1.0, 0.0 1.0

OK 100% under

Design Member 4, Load Case 1 (Linear), Biaxial Bending + Compression Buckling


y = 0.991, z = 0.896, LT = 1.0
For Class 1 and 2 cross-sections:
Ai = A = 31580.0 mm

OK 86% under

Wy = Wpl,y = 4050.0x10mm and Wz = Wpl,z = 1280.0x10mm


My.Ed = 0 and Mz.Ed = 0

NRk = fyAi = 235.0*31580.0 = 7421.3 kN


My,Rk = fyWy = 235.0*4050.0 = 951.75 kN-m
Mz,Rk = fyWz = 235.0*1280.0 = 300.8 kN-m
Calculate Cmy

Me/Mh < -1.0, -354.869/215.02 < -1.0, -1.65 < -1.0 = -1.0

Mh/Ms < -1.0, 215.02/-69.924 < -1.0, -3.075 < -1.0 h = -1.0
Cmy = 0.90 + 0.10h(1+2) = 0.90 + 0.10*-1.0*(1+2*-1.0) = 1.0
Calculate Cmz

= Me/Mh = 0.0/0.0 = 0.0

h = Mh/Ms = 0.0/0.0 = 0.0


Cmz = 0.90 + 0.10h = 0.90 + 0.10*0.0 = 0.9
Calculate CmLT

Me/Mh < -1.0, -354.869/215.02 < -1.0, -1.65 < -1.0 = -1.0

Mh/Ms < -1.0, 215.02/-69.924 < -1.0, -3.075 < -1.0 h = -1.0
CmLT = 0.90 + 0.10h(1+2) = 0.90 + 0.10*-1.0*(1+2*-1.0) = 1.0
kyy = Cmy(1 + (y - 0.2)NEd/(yNRk/M1)) = 1.0*(1 + (0.239 - 0.2)*250.0/(0.991*7421.3/1.0)) = 1.001
kzz = Cmz(1 + (2z - 0.6)NEd/(zNRk/M1)) = 0.9*(1 + (2*0.472 - 0.6)*250.0/(0.896*7421.3/1.0)) = 1.028
kyz = 0.6kzz = 0.6*1.028 = 0.617
kzy = 0.6kyy = 0.6*1.001 = 0.601
Check 1:
NEd/(yNRk)/M1 + kyy(My,Ed + My,Ed)/(LTMy,Rk)/M1 + kyz(Mz,Ed + Mz,Ed)/My,Rk/M1 1.0, 0.407 1.0

OK 59% under

Check 2:
NEd/(zNRk)/M1 + kzy(My,Ed + My,Ed)/(LTMy,Rk)/M1 + kzz(Mz,Ed + Mz,Ed)/My,Rk/M1 1.0, 0.262 1.0

OK 74% under

End of check of C:\Users\jake.FDS\Desktop\EC3 example.mfd to