Em 3490.
Em 3490.
Em 3490.
Application:
Rish Master 3490 is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy to class 1.0 accuracy with 7 digit auto-resetting electromechanical counter. The unit provides LED indication for healthy phase, earthed load reverse current. The RISH Master 3490 is available in two version 3phase 3 wire and 3 phase 4 wire unbalanced load and is ideal for secondary metering in industrial applications.
Energy Meter
Product Features:
Class 1.0 Accuracy Class 0.5 optional Available in 3 phase 4 wire and 3 phase 3 wire version Led indication: Healthy phase, Reverse Current Complies to Standards IS 13779,IEC 62053-21 7 Digit auto-resettable mechanical counter True RMS measurement Fully programmable CT ratios Fully isolated current input Built in transient protection State of art SMD technology Pulse output: one potential free relay contact
C l a s s 1 . 0 (0.5Optional) Phase Neutral 57.7 - 277V L-N Line-Line 100 - 480V L-L according to IEC 62053-21 85-500V L-L (49-288V L-N) 5A 5A-9999A 120% of Nominal Value or 6A MAX(as per standard) 0.2% of the rated current 6A Relay contact >=40ms Self powered 45 to 66 Hz < 8 VA < 2 VA 7 digit auto-resetting electromechanical counter 1 per kW.h 3 x green: Voltage phase monitoring 3 x red : reverse connected CT warning Red LED flashing at a rate proportional to measured power. 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x for 1 second, repeated 5 times at 5 min 0.5 inductive 1 0.8 capacitive Panel mount to DIN 42700 Polycarbonate M4 captive screw clamp 2 side clamps
Input Current:
Nominal input current System CT Primary Ratios : Max Continuous Input Current : Start up current Max continuous input current
Pulse output
Pulsed output Pulse duration
-Pulse Indication:
The unit features a red LED pulse indicator which flashes at rate proportional to measured power.
Auxiliary Supply:
AC Auxiliary Supply AS Auxiliary supply frequency range
VA Burden:
Nominal input voltage burden Nominal input current burden
Counter:
Counter: Reading resolution
Advantages:
Since CT ratio is user selectable, a single meter can be used for all application Low VA burden Tamper proof Easy to wire
LED Indication:
LED indicator display:
Pulse indicator
Overload Withstand:
Voltage
Dimension:
Dimension Panel cutout Weight Reference temperature Input waveform Input frequency Auxiliary supply voltage 96mm high x 96mm wide x 80mm deep 92mm x 92mm 320-400 gm 23C +/- 2C Sinusoidal (distortion factor 0.005) 50 or 60 Hz 2% Rated Value 1%
Enclosure style:
Enclosure style Enclosure material Terminals Fixing
Energy Meter
Environmental
Operating temperature Storage temperature 0 to +55C -20 to +65C
Pulse output 2 5 8 11 1 3 4 6 7 9 + 2 5 8
Pulse output 1 3 7 9 + -
k L1 L2 L3 N K
I L K
I k L K LX X X I X X X L1 L2 L3 K
I L K K IX X X L
Dimensions:
3.78 96mm 3.15 80mm 3.62 96mm
3.78 96mm
FRONTDISPLAY AREA
PANEL CUTOUT
3.62 96mm