RISH EM 3490 DIN Panel Mounted Kilowatt Hour

Application:
Rish Master 3490 is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy to class 1.0 accuracy with 7 digit auto-resetting electromechanical counter. The unit provides LED indication for healthy phase, earthed load reverse current. The RISH Master 3490 is available in two version 3phase 3 wire and 3 phase 4 wire unbalanced load and is ideal for secondary metering in industrial applications.

Energy Meter

Product Features:
Class 1.0 Accuracy Class 0.5 optional Available in 3 phase 4 wire and 3 phase 3 wire version Led indication: Healthy phase, Reverse Current Complies to Standards IS 13779,IEC 62053-21 7 Digit auto-resettable mechanical counter True RMS measurement Fully programmable CT ratios Fully isolated current input Built in transient protection State of art SMD technology Pulse output: one potential free relay contact

Technical Specifications: Accuracy:


Active energy (kWh)

Input Voltage: LED Indication: -3 phase voltage status:


The unit contains three green LED, one for each voltage phase. Three illuminated LEDs indicate active monitoring of each of the three phases. In case if any one phase voltage is missing the appropriate LED will switch OFF .However the meter will continue to accurately measure energy for the available voltage phases. In case of phase sequence error all three LED will start blinking with a repetition rate of 1Hz. Nominal input voltage (AC RMS) Max continuous input voltage Input voltage tolerance

C l a s s 1 . 0 (0.5Optional) Phase Neutral 57.7 - 277V L-N Line-Line 100 - 480V L-L according to IEC 62053-21 85-500V L-L (49-288V L-N) 5A 5A-9999A 120% of Nominal Value or 6A MAX(as per standard) 0.2% of the rated current 6A Relay contact >=40ms Self powered 45 to 66 Hz < 8 VA < 2 VA 7 digit auto-resetting electromechanical counter 1 per kW.h 3 x green: Voltage phase monitoring 3 x red : reverse connected CT warning Red LED flashing at a rate proportional to measured power. 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x for 1 second, repeated 5 times at 5 min 0.5 inductive 1 0.8 capacitive Panel mount to DIN 42700 Polycarbonate M4 captive screw clamp 2 side clamps

Input Current:
Nominal input current System CT Primary Ratios : Max Continuous Input Current : Start up current Max continuous input current

-Reverse connected current transformer :


Three red LEDs are provided for each of three phases. Illumination of the red LED indicates a reverse connected CT. The meter will continue to register the energy consumption even if the CTs are reverse connected.

Pulse output
Pulsed output Pulse duration

-Pulse Indication:
The unit features a red LED pulse indicator which flashes at rate proportional to measured power.

Auxiliary Supply:
AC Auxiliary Supply AS Auxiliary supply frequency range

Low back depth:


The instrument has very low back depth (behind the panel) of less than 80 mm in spite of optional features like pulse output

VA Burden:
Nominal input voltage burden Nominal input current burden

Enclosure Protection for dust and water:


conforms to IP 54 (front face)

Counter:
Counter: Reading resolution

Compliance to International Safety standards


Compliance to International Safety standard IEC 61010-1- 2001

Advantages:
Since CT ratio is user selectable, a single meter can be used for all application Low VA burden Tamper proof Easy to wire

LED Indication:
LED indicator display:

Pulse indicator

Overload Withstand:
Voltage

Dimension:
Dimension Panel cutout Weight Reference temperature Input waveform Input frequency Auxiliary supply voltage 96mm high x 96mm wide x 80mm deep 92mm x 92mm 320-400 gm 23C +/- 2C Sinusoidal (distortion factor 0.005) 50 or 60 Hz 2% Rated Value 1%

Max short duration Current

Operating Measuring Ranges


Power Factor

Reference conditions for Accuracy:

Enclosure style:
Enclosure style Enclosure material Terminals Fixing

RISH EM 3490 DIN Panel Mounted Kilowatt Hour


Applicable Standards:
Standard Compliant with IP protection IS 133779,IEC62053-21 IEC 1036, EMC and LVDT IP54

Energy Meter

Electrical Connections: Wiring:


Input connections are made directly to shrouded screw clamp terminals. Numbering is clearly marked on the plastic molding. Choice of cable should meet local regulations. Terminals for both current and voltage inputs will accept up to two 12 AWG diameter cables.

Environmental
Operating temperature Storage temperature 0 to +55C -20 to +65C

Pulse output 2 5 8 11 1 3 4 6 7 9 + 2 5 8

Pulse output 1 3 7 9 + -

k L1 L2 L3 N K

I L K

I k L K LX X X I X X X L1 L2 L3 K

I L K K IX X X L

3 Phase 4 Wire Unbalanced Load

3 Phase 3 Wire Unbalanced Load

Dimensions:
3.78 96mm 3.15 80mm 3.62 96mm

3.78 96mm

FRONTDISPLAY AREA

PANEL CUTOUT

3.62 96mm

MAX PANEL THICKNESS 0.19,5MM