Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Centrifugal compressor operations

The wet gas compressor is used as an example in this article reviewing compressor performance, operating conditions and basic control philosophy
Tony Barletta and Scott W Golden Process Consulting Services Inc

he FCC wet gas compressors major func- pressure drop. System pressure drop depends on tion is reactor pressure control. The equipment design and operation, while compresmachine must compress gas from the main sor and control system performance set receiver column overhead receiver to gas plant operating pressure. Wet gas compressors operate at fixed pressure while maintaining stable regenerator- or variable speed. Fixed speed compressors reactor differential pressure (Figure 1). Typically, throttle compressor suction while variable speed reactor-regenerator differential pressure must be machines use steam turbines or variable speed controlled within a relatively narrow +2.0psi to motors to control receiver pressure. 2.0psi (+0.14 to 0.14 bar) range to permit If necessary, compressor surge control systems stable catalyst circulation. The wet gas compres- recycle gas to ensure inlet gas flow rate is mainsor and its control system play a vital role in tained above the minimum flow (surge point or maintaining steady reactor operating pressure. line). Even when receiver pressure is stable, To be sure, optimum FCC operation requires rapid system pressure drop changes from tray balancing regenerator and reactor pressures to flooding and dumping will cause rapid changes wet gas and air blower constraints. Nonetheless, in reactor pressure. reactor pressure is presumed constant throughMost motor driven compressors operate at out this article to simplify discussions. fixed speed using suction throttle valves to vary Reactor operating pressure is regu-lated by the pressure drop from the main column overhead main column overhead receiver pressure and receiver to the compressor inlet (Figure 2). The system pressure drop from the reactor to the pressure controller manipulates the throttle valve overhead receiver. The wet gas machine needs to position and pressure drop to maintain constant have sufficient capacity to compress receiver wet gas to the gas plant operating pressure. Wet gas Differential compressor Reactor effluent composition, pressure overhead receiver pressure and PC temperature, and gasoline PC PI PI endpoint all influence the Atmosphere amount of wet gas and its molecular weight. Variability in main column overhead receiver pressure or unstable system pressure drop produce reactor pressure Main Reactor Regenerator swings. These can cause catalyst column circulation problems and other operability concerns. Oil feed Reactor operating pressure is Air set by main column overhead receiver pressure and system Figure 1 Regenerator-reactor differential pressure

www.digitalrening.com/article/1000294

PTQ Q3 2004 1

Main column Spillback FI Motor Compressor C.W. PC Overhead receiver Inter-stage receiver FI C.W. Spillback Gas plant

variable speed motor is operating at maximum speed or amps, feed rate or reactor temperature must be reduced to lower wet gas rate to the compressor capacity. Fixed or variable speed motors and turbines must have sufficient power to compress the mass flow rate of gas while meeting the differential head between the overhead receiver and the gas plant. Otherwise, reactor temperature or feed rate must be reduced to decrease the amount of receiver wet gas flow to the driver limit.

Figure 2 Fixed speed compressor and inter-condenser system

Compressor Design

receiver pressure. Normal system pressure drop variation is slow and predictable. Therefore, receiver pressure can be adjusted to maintain constant reactor pressure. As long as the throttle valve is not fully open, then the compressor has excess capacity. Once the throttle valve is fully open and spillback valve is closed, the machine can no longer compress wet gas flow to the gas plant operating pressure. Generally, reactor temperature or feed rate is reduced to permit the compressor throttle valve to regain pressure control so that flaring can be avoided. Variable speed compressors use steam turbines or variable speed motors to control receiver pressure. Speed is adjusted to change the operating point on the compressor map to meet the system flow-head requirements for stable reactor pressure control. As system pressure drop increases, receiver pressure is reduced. Therefore, machine speed must be increased to compress the higher gas flow rate and to meet higher head requirements. Once the turbine governor is wide-open or the

Low-stage

High-stage

3-stages

3-stages

Suction

Intercondenser system

Discharge

Figure 3 Compressor schematic with inter-condenser

Wet gas machines use six to eight impellers (stages) to compress gas from the main column overhead receiver to the gas plant operating pressure. Most have inter-stage condensing systems after the first three or four stages (low-stage) that cool the compressed gas, condense a small portion and separate the gas and liquid phases (Figure 3). Inter-stage receiver gas is then compressed in the last three or four stages (high-stage). Inter-stage condensers reduce gas temperature and raise compressor efficiency by 57%, but they also consume pressure drop. Separate flow-polytropic head and flow-polytropic efficiency curves are needed to evaluate overall compressor system performance. These curves have inlet gas flow rate on the Xaxis and polytropic head developed and polytropic efficiency on the Y-axis. Consequently, overall compressor performance and power consumption depend on each compressor sections performance curves and the effects of the inter-condenser system. Evaluating overall performance of these compressors is more complex than a machine without inter-cooling, but fundamentally the same. Some compressors do not have inter-condenser systems. A single flow-polytropic head and flowpolytropic efficiency curve represent overall performance. They have lower efficiency and the gas temperature leaving is generally near 300F rather than 200F with an inter-cooled design. These machines must compress all wet gas from inlet conditions to the gas plant operating pressure, resulting in higher power consumption.

2 PTQ Q3 2004

www.digitalrening.com/article/1000294

Stable operating range


Each wet gas compressor section must be operated within its stable flow range. At fixed speed, the compressor curve 11 0% begins at the surge point and ends at rat ed Sp stonewall, or choke flow. Surge point is ee d an unstable operating point where flow Surge line 100 is at minimum. At surge, the compressor % suffers from flow reversals that cause vibration and damage. At the other end 90% of the curve is the choke (or stonewall) point. At the choke point, the inlet flow 80% is very high and the head developed very low. Flow through the machine 70% approaches sonic condition, or Mach 1.0. Polytropic efficiency also drops rapidly near stonewall. Stonewall For variable speed compressors, there is a region between the surge and stonewall lines where there is stable machine performance (Figure 4). The compressor Inlet flow flow-polytropic head can be varied anywhere within this region. Because Figure 4 Variable speed ow-head map there is no throttling, all power goes into compression, which minimises power Surge control ensures that inlet flow rate is consumption. maintained above minimum (surge point or Stable compressor perform-ance is defined surge line) at all times. A flow meter in the between these two flow-head limitations. Some compressor suction or discharge and inlet machine designs can vary flow by 25% or more temperature and pressure are used to calculate between surge and stonewall points, while others the actual flow rate (ICFM) into the low- and have only 68% flow variation between these high-stage of compression. limits. Compressors with small (narrow) stable As suction flow (ICFM) decreases toward the flow regions need to have robust surge control surge line (or point), the spillback control valve systems. The head-flow curve basic slope is rela- opens to recycle gas from discharge to suction to tively flat near the surge point and becomes raise inlet flow rate. Spillback flow is kept at steeper as inlet flow is increased. The impeller minimum to reduce power consumption. blade angle determines the shape of the curve Compressors with inter-condensers need two and the compressor efficiency. independent spillback systems from discharge to the suction of each section. Spillback streams Basic compressor control should be routed in front of upstream exchangReactor yield and condenser operating tempera- ers so the heat of compression is removed ture and pressure change throughout the day. (Figure 2). Therefore, the gas rate from the main column receiver is variable. Consequently, the compressor Without inter-condenser control system must be capable of maintaining The simplest wet gas compressor to evaluate is a constant receiver pressure. Thus, fixed speed fixed speed machine with no inter-condensers. It compressors have suction throttle valves and vari- has a single flow-head curve (and single flowable speed machines change speed to compensate efficiency curve) with surge point rather than a for gas rate changes. Because the compressor inlet line. gas flow rate is not constant and may be below Although molecular weight does affect develthe surge point or line, the compressor is typically oped head, typical molecular weight variations in designed with a surge control system. a gas oil cracker do not materially change
Polytropic head

www.digitalrening.com/article/1000294

PTQ Q3 2004 3

The suction throttle valve plays an important role for a fixed speed motor driven compressor. Throttle valve pressure drop Surge point 55 controls overhead receiver pressure (Figure 8,200 rpm 6) so that reactor pressure is stable. 50 Throttle valve position and pressure drop compensate for changes in receiver gas 45 flow rate or receiver pressure set point changes. Because compressor discharge 40 Stonewall pressure is held constant by the gas plant pressure controller, suction pressure will 35 vary and follow the flow-head curve. 10,200 10,400 10,600 10,800 11,000 11,200 11,400 Inlet volume flow, icfm When gas rate leaving the overhead receiver is higher than flow at the surge Figure 5 Flow-head curve for a six-stage compressor point, the spillback is closed. Hence, compressor suction pressure will ride up and down the flow-head curve as long as the throttle valve is generating pressure Gas plant Main column drop and not fully open. As compressor Spillback inlet flow rate approaches the surge point, Motor the spillback valve opens recycling gas to Compressor ensure sufficient inlet flow into the machine. When the spillback is open, spillback flow rate determines the operating point on the curve. Flow rate must always be maintained above the surge point with FC suction pressure determined by the polyC.W. tropic head generated at the minimum flow PC control point. Since the amount of gas leaving the overOverhead head receiver depends on reactor effluent receiver composition and overhead receiver conditions, the compressor suction pressure will vary. As previously discussed, the compresFigure 6 Receiver pressure control: compressor suction sor has unused capacity as long as the throttling suction throttle valve is not fully open. When establishing operating conditions compressor flow-head performance curve. to stay within an existing machines capacity, or Whereas, resid crackers processing varying if considering a revamp, determining the amounts and quality of residues may have as compressor suction pressure needed to meet the much as eight number variations in molecular proposed operation is critical. Compressor weight, thus the flow-head performance curve is suction pressure is calculated from the compresaffected. The manufacturer should provide sor performance curve. Because the flow and curves at maximum and minimum molecular head terms are affected by suction pressure, estiweight. mating this pressure is an iterative process. Figure 5 is the performance curve for a sixCentrifugal compressors generate a fixed polystage FCC wet gas compressor that is also tropic head (and not a fixed discharge pressure) discussed in this articles case study. The at a given inlet flow rate with suction pressure, compressor develops a fixed polytropic head for gas molecular weight and gas temperature all a given inlet flow rate and the curve can be used influencing both inlet flow rate and polytropic to predict compressor performance at different head. The polytropic head equation is shown in process conditions. Equation 1 below.
60 Polytropic head, 1,000 ft

4 PTQ Q3 2004

www.digitalrening.com/article/1000294

where MW Molecular weight Zavg Average compressibility T1 Suction temperature, R n Compression coefficient P1 Suction pressure, psia P2 Discharge pressure, psia Understanding each variables impact on inlet flow rate and polytropic head is important. Molecular weight and suction pressure have a significant influence on performance, while compressor discharge pressure (P2) is fixed and temperature effects are small. Gas molecular weight (MW) is primarily controlled by reactor effluent composition. As molecular weight decreases the inlet flow rate increases. Because the compressor discharge pressure is fixed, compressor suction pressure must be high enough to generate the head corresponding to the inlet flow rate into the compressor. Again, for a fixed speed compressor, as long as the compressor throttle valve is not fully open, it has unused capacity. Thus, molecular weight changes simply cause throttle valve position and pressure drop to adjust, to maintain receiver pressure. But once the throttle valve is fully open, the machine is operating at maximum capacity. Inlet gas temperature has little influence on compressor capacity because it is based on absolute temperature. Hence, a 20F rise in temperature changes the head term by only 3% and the flow term a similar amount. Compressor suction pressure has a large influence on inlet gas flow rate. For a fixed mass flow rate, raising suction pressure decreases inlet volume by the absolute pressure ratio. At constant receiver pressure, compressor inlet pressure is determined from the flow-head curve for a fixed speed compressor. Using the compressor curve shown on Figure 5, the suction pressure will be that needed to satisfy the inlet flow and head term simultaneously. Throttle valve pressure drop will vary to maintain inlet flow rate between 10400 and 11100icfm, while meeting the gas plant discharge pressure.

As long as the receiver gas flow rate is above the surge point, then the spillback valve will be closed. However, as gas flow approaches surge, the spillback valve opens to maintain flow in a stable region of the curve. Suction pressure is a dependent variable as long as the throttle valve has pressure drop. Once the control valve is wide open, the gas rate must be reduced or the suction pressure increased to reduce the inlet volume into the compressor. Variable speed compressors have an operating region between the surge and stonewall lines as previously illustrated in Figure 3. Because variable speed compressors do not incorporate a throttle valve, main column overhead receiver pressure controller varies speed to maintain receiver pressure. As long as the receiver gas flow rate is above the surge line flow rate, there will be no spillback. However, if receiver gas flow is below the surge line, then the spillback will open to meet the minimum flow. In the previous Figure 3, maximum compressor capacity occurs when the compressor is operated at maximum speed. As long as the compressor driver had sufficient energy, then minimum overhead receiver operating pressure will be based on the flow-head developed at 110% of the rated speed for the curve shown in Figure 3.

Capacity: driver power


Compressor power consumption is a function of the mass flow, polytropic head, polytropic efficiency, and gear losses. Compressor shaft horsepower (SHP) is shown in Equation 2 below:
Compressor SHP = [(mH)/(nr 33000)] 1.02

where Hr Polytropic head m Mass flow rate of gas nr Polytropic efficiency 1.02 2% gear losses SHP Shaft horsepower. Unlike variable speed compressors, fixed speed compressors have suction throttle valves to control overhead receiver pressure. Satisfying the flow-head curve requires pressure drop across the control valve and throttling always wastes energy. Because variable speed compressors change speed to match the process flow-head requirements, they consume less

www.digitalrening.com/article/1000294

PTQ Q3 2004 5

energy. However, the capital cost of steam turbines or variable speed motors is higher than a fixed speed motor.

With inter-condenser
Figure 3 is a schematic of a six-stage compressor with three-stages (low-stage) in front and threestages (high-stage) behind the inter-condenser. Gas must still be compressed from the overhead receiver pressure to the gas plant operating pressure. However, the low-stage discharges intermediate pressure gas (6590psig) to an inter-condenser where it is cooled from approximately 200F to 100130F, depending on whether air or cooling water is used. The condenser outlet stream is sent to a separator drum where the gas and liquids (oil and water) are separated. Inter-stage drum gas is fed to the high-stage section of the compressor. Each section has its own flow-polytropic head and flow-polytropic efficiency curves. Because the inter-condenser system condenses a portion of the low-stage gas, mass rate and gas molecular weight (typically four to five numbers lower than main column overhead receiver gas) is lower into the high-stage. This reduces compressor power consumption and allows for more efficient compressor design. Because the low-stage and high-stage sections have separate operating curves, each requires an independent surge control system. One part of the compressor may be operating with spillback to avoid surge, while the other may have the spillback closed. Fixed speed compressors with an inter-cooler have a suction throttle valve in the low-stage to control main column overhead receiver pressure while high-stage discharge pressure is controlled by the gas plant sponge absorber or amine contactor pressure controller. Typically, there is no throttle valve in the suction line to the highstage. Consequently, discharge pressure from the low-stage and suction pressure to the high-stage are dependent variables. Inlet flow rate into the low- and high-stages must always be above the surge point. Separate spillback systems from the low-stage discharge to inlet of the main column condensers and from the high-stage discharge to the inlet of the intercondenser maintain flow above surge for both compressor sections. Thus, suction and discharge pressure from the first three-stages and suction

and discharge pressure from the last three-stages are dependent on each other, inter-condenser system pressure drop, and the amount of material condensed. While principles of compression are the same, overall performance is more difficult to evaluate. Fortunately, process flow models, such as Simscis proprietary ProII or Provision, allow the low- and high-stage flow-polytropic head curves and flow-polytropic efficiency curves, and the inter-condenser system, to be rigorously modelled. Thus, inter-stage operating pressures can be determined through an iterative process without excessive calculations.

Case study: Minimising compressor modications


An FCC unit was revamped to increase unit capacity by 40%. In addition, gas plant limitations required undercutting gasoline to produce heavy naphtha from the main fractionator to reduce liquid loading through the gas plant. The existing compressor was a seven-stage machine with no inter-condenser and a 4400 horsepower motor. A suction throttle valve controlled main fractionator overhead receiver pressure. Prior to the revamp, reactor pressure was 20psig with a compressor inlet pressure of approximately 4-5psig. The 40% higher feed rate and higher gas from undercutting, together, would have increased inlet flow rate by more than 50% if the 4psig suction pressure was maintained. Thus, a new parallel compressor or one new larger compressor would have been required. Because this solution was high cost, alternatives were considered. When evaluating compressor performance, the complete system from the reactor through the compressor outlet needs to be evaluated as a single system. Undercutting gasoline increases wet gas flow rate if no other changes are made because it decreases the amount of liquid product from the main column overhead receiver. Gasoline sponges C3+ hydrocarbons leaving the condenser. Therefore, undercutting reduces sponging at fixed receiver temperature and pressure. For example, undercutting 10% of the gasoline raises wet gas flow rate by approximately 57%. As the percent undercutting increases, so does the amount of wet gas from the overhead receiver. Increasing mass flow rate through the

6 PTQ Q3 2004

www.digitalrening.com/article/1000294

compressor without large changes in the inlet Reactor system pressure drop flow rate requires higher suction pressure. System pressure drop from the reactor to the Components P, psi compressor inlet must be reduced. In this case, Reactor cyclones 2 Reactor vapour line 1 the reactor pressure operated at approximately Reactor line coke 4 20psig and the system pressure drop was 16 Psi, Main column 3 resulting in a 4psig compressor suction pressure. Condenser 3 High pressure-drop components included reacPiping 2 Flow control/metering 1 tor line coke formation, main column overhead Total 16 system and column internals pressure drop. Table 1 shows each major component and its measured pressure drop. Substantial reduction Table 1 in system pressure drop was required to lower compressor inlet flow rate to within 10400 to the existing seven stages of compression would 11200 inlet cubic feet per minute stable operat- have been 350psig, which exceeded the maxiing range. mum allowable working pressure (MAWP) of the Increasing compressor suction pressure raises major equipment in the gas plant. Hence, condensation in the overhead receiver, decreases compressor head had to be reduced. inlet flow rate and increases compressor capacCompressor power requirements also have to ity. In this instance, main column overhead be considered. Both the flow-head and flow-polyreceiver pressure and temperature needed to be tropic efficiency curve is needed to evaluate 12psig and 100F to maintain inlet flow rate power consumption. Power requirement would within stable operating range. Coking in the reac- have been more than 5100hp due to the higher tor line, main column pressure drop, piping, flow mass flow rate. Hence, the existing 4400hp metering, and condenser pressure drop all had to motor would have to be replaced. Replacing a be reduced. Otherwise, a new parallel compres- motor or steam turbine can be very costly sor would have been needed. because it often requires major utilities system Overhead condenser exchanger surface area, modifications. Although the compressor OEM or cooling water (CW) flow rate, and CW tempera- compressor expert should do comprehensive ture all influence wet gas flow rate. Each 1F compressor analyses, the revamp engineer can reduction in receiver temperature lowers wet gas perform preliminary review by making simplifyrate by approximately 1%. Thus, decreasing ing assumptions such as equal head rise per temperature by 10F lowers the wet gas rate by about 10%. Although temperature has little effect on gas volume, main Gas plant Main column column overhead receiver temperature has Spillback a large impact on condensation. Cost-effecMotor tive changes that reduce receiver Compressor temperature should always be considered to maximise existing compressor capacity Remove or to minimise modifications. stage In this instance, raising receiver pressure from 5 to 12psig and lowering temperature FC to 100F decreased the amount of wet gas C.W. produced so that the gas inlet flow rate was 12 +40% feed rate PC within the existing compressor capacity. 5 Base feed rate Raising compressor inlet pressure (and Overhead lowering temper-ature) decreased inlet receiver flow rate, but it also raised compressor Pressure, psig discharge pressure. Since centrifugal compressors develop fixed polytropic head, discharge pressure (P2 in Equation 1) from Figure 7 Receiver operating pressure: before and after revamp

www.digitalrening.com/article/1000294

PTQ Q3 2004 7

70 Polytropic head, 1,000 ft 65 60 55 50 45 40 10,200 10,400 10,600 10,800 11,000 Inlet volume flow, icfm 11,200 11,400

7-stages

6-stages

Figure 8 Flow-head curve for seven- and six-stage compressor

5,200 5,000 Total power, hp 4,800 4,600 4,400 4,200 4,000 10,200

7-stages

Motor horsepower 6-stages

10,400

Tony Barletta is a chemical engineer with Process Consulting Services in Houston, Texas, USA. His primary responsibilities are conceptual process Figure 9 Flow-power requirements for 7- and 6-stage compressor design (CPD) and process design for renery revamps. He holds a BS degree in chemical engineering from the stage of compression to determine whether Lehigh University. E-mail: tbarletta@revamps.com removing a stage of compression or trimming Scott W Golden is a chemical engineer with Process Consulting the impellers is needed. Services. His previous experience includes renery process engIn this instance, the seven-stage compressor ineering and distillation troubleshooting and design. He has developed about 9500ft of head rise per stage of written more than 80 technical papers on revamping, troublecompression. Therefore, eliminating a stage shooting, and distillation. He holds a BS degree in chemical would reduce developed head by about 9500ft. engineering from the University of Maine. Because compressor discharge pressure needed E-mail: sgolden@revamps.com

10,600 10,800 11,000 Inlet volume flow, icfm

11,200 11,400

machine and a de-staged six-stage compressor generated by the OEM. Compressor drivers must also be able to supply the power requirement throughout the stable operating range of the compressor. Power consumption depends on mass flow rate through the machine, polytropic head developed and compressor polytropic efficiency. Flow-polytropic efficiency curves are supplied by the manufacturer and allow power consumption throughout the stable flow range to be easily calculated. Figure 9 shows a comparison between the power requirements of a seven- and sixstage compressor. By eliminating one stage of compression, machine horsepower requirements were reduced below the existing 4400hp motor. Centrifugal machines are used in many refinery units to compress gases. The principles of compression are the same irrespective of the process units. Only the gases compressed and the process variables are different. Understanding centrifugal compressor flow-head and flow-efficiency curves is an essential when evaluating process changes or when revamping.

to be approximately 210psig to meet gas plant operating pressure and to stay below the 250psig pressure relief valve (PSV) settings, the required polytropic head at 12psig suction and 210psig discharge pressure was approximately 46000ft of head. Thus, de-staging was a practical solution. Figure 8 shows the comparison between the flow-head curves for the original seven-stage

Links
More articles from: Process Consulting Services More articles from the following categories: Revamps, Shutdowns and Turnarounds Fluid Catalytic Cracking Rotating Equipment

8 PTQ Q3 2004

www.digitalrening.com/article/1000294

You might also like