Boiler Feed Water System
Boiler Feed Water System
Boiler Feed Water System
S Shariq Ahmed
Asst. General Manager Allied Energy Systems Pvt. Ltd.
S Shariq Ahmed
INTRODUCTION
S Shariq Ahmed
Function
Boiler feedwater is water used to supply ("feed") a boiler to generate steam or hot water. At thermal power stations the feedwater is usually stored, pre-heated and conditioned in a feedwater tank and forwarded into the boiler by a boiler feedwater pump The function of the Feedwater System is to supply high-pressure water to the boiler during start-up, normal, and emergency operations. The System automatically maintains the proper flow to and water level in the boiler drum.
S Shariq Ahmed
Function
The Feedwater System also supplies water for Desuperheater Sprays that control the Superheat steam temperature.
The feed water used in the steam boiler is a means of transferring heat energy from the burning fuel to the mechanical energy of the spinning steam turbine. The total feed water consists of re-circulated condensate water and purified makeup water.
The makeup water in a 500 MW plant amounts to perhaps 20 US gallons per minute (1.25 L/s) to offset the small losses from steam leaks in the system.
S Shariq Ahmed
Feedwater Heater
Feed Water Regulation Valves Boiler Economizer Inlets Feedwater System Block Diagram
S Shariq Ahmed
Feedwater Heater
Feed Water Regulation Valves Boiler Economizer Inlets Feedwater System Block Diagram
S Shariq Ahmed
The Feedwater exits the bottom of the Deaerator to the suction of the Boiler Feed Pumps (BFP).
The Deaerators are high enough to supply the Net Positive Suction Head (NPSH) to the Boiler Feed Pumps.
S Shariq Ahmed
The pumps can provide Feedwater to any of the High Pressure (HP) Feedwater Heaters.
After the Feedwater is heated in the HP heaters it is then sent through drum level control valves on the boilers and from the drum level control valves to the Economizer inlet valves.
S Shariq Ahmed
The Boiler Feed Pumps can also pump water to any of the HP heaters and boilers.
S Shariq Ahmed
The Boiler Feed Pumps pump the Feedwater through the drum level control valve to the Low Temperature Economizer.
There is a tie line between the Deaerator on Units.
S Shariq Ahmed
S Shariq Ahmed
S Shariq Ahmed
Although steam turbines cannot be used for start-up unless a separate source of steam is available for there operation.
With any pump, the pressure tends to fall as the throughput increases rises, on the other hand due to the effect of friction, the resistance offered by the boiler system to the flow of water increases as the flow rate increases.
S Shariq Ahmed
Variable speed pumps are more expensive but the increase in cost tends to be offset by the operational cost savings.
S Shariq Ahmed
S Shariq Ahmed
A recirculation line prevents the liquid in the pump from becoming hot enough to vaporize and causing cavitation and possible BFP impeller damage.
S Shariq Ahmed
S Shariq Ahmed
S Shariq Ahmed
S Shariq Ahmed
Feedwater Heaters
A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler.
Preheating the feedwater reduces the irreversibility involved in steam generation and therefore improves the thermodynamic efficiency of the system.
This reduces plant operating costs and also helps to avoid thermal shock to the boiler metal when the feedwater is introduced back into the steam cycle.
S Shariq Ahmed
Feedwater Heaters
Pressure classification
Low pressure heater A heater located between the condensate pump and either the boiler feed pump or , if present , an intermediate pressure (booster) pump. It normally extracts steam from the low pressure turbine.
S Shariq Ahmed
S Shariq Ahmed
Feedwater Heaters
Pressure classification
Intermediate pressure heater A heater located between the booster pump and the boiler feed pump. Usually the tubeside pressure is within 200-300 psi of the low pressure heaters , and the steam is extracted from the intermediate pressure turbine.
S Shariq Ahmed
Feedwater Heaters
Pressure classification
High pressure heater A heater located downstream of the boiler feed pump. Typically, the tubeside design pressure is at least 1500 psig, and the steam source is the high pressure turbine. With a similar purpose to the low pressure feed heaters, the high pressure feed heaters are the last stage of feedwater heating before the feedwater enters the boiler system at the economizer
S Shariq Ahmed
S Shariq Ahmed
S Shariq Ahmed
S Shariq Ahmed
Feedwater Heaters
Orientation
Vertical, Channel Down Although these conserve floor space, the amount of control area available for liquid level fluctuation is less.
S Shariq Ahmed
Feedwater Heaters
Orientation
Vertical, Channel Up These are the least frequently used. Disassembly is by means of bundle removal. If a subcooling zone is present, it must extend the full length of the bundle, since the water must enter the bottom and exit at the top end of the heater.
S Shariq Ahmed
Feedwater Heaters
Orientation
Horizontal Most heaters are of this configuration. These are the most stable in regard to level control, although they occupy more floor space. Disassembly is by means of either shell or bundle removal. Most are floor mounted, although some are mounted in the condenser exhaust neck.
S Shariq Ahmed
Feedwater Heaters
Zones
Zones are separate areas within the shell in a feedwater heater Condensing Zone All feedwater heaters have this zone. All of the steam is condensed in this area , and any remaining non condensable gases must be removed. A large percentage of energy added by the heater occurs here.
S Shariq Ahmed
Feedwater Heaters
Zones
Zones are separate areas within the shell in a feedwater heater Subcooling Zone The condensed steam enters this zone at the saturation temperature and is cooled by convective heat transfer from the incoming feedwater.
S Shariq Ahmed
Feedwater Heaters
Zones
Zones are separate areas within the shell in a feedwater heater Desuperheating Zone The incoming steam enters this zone, giving up most of its superheat to the feedwater exiting from the heater.
S Shariq Ahmed
Feedwater Heaters
Type of feedwater heaters
Open feedwater heater. An open feedwater heater is merely a direct-contact heat exchanger in which extracted steam is allowed to mix with the feedwater
S Shariq Ahmed
Feedwater Heaters
Type of feedwater heaters
Closed feedwater heater. Closed feedwater heaters are typically shell and tube heat exchangers where the feedwater passes throughout the tubes and is heated by turbine extraction steam
S Shariq Ahmed
Feedwater Heaters
Feedwater Heaters are of the shell and tube, extraction steam type and are flue gas type heaters.
Steam from the turbine extraction or from the steam header can supply these heaters The feedwater heaters are shell and tube, U-tube type heaters.
Feedwater enters the bottom of the heater and passes through the tubes, picking up heat from the steam on the shell side of the heater; the feedwater exits the top of the heater.
S Shariq Ahmed
Feedwater Heaters
Steam from the steam header or from the turbine extraction, enters the top of the shell and through baffles is directed across the tubes, as the steam crosses the tube it gives up heat to the water passing through the tubes and condenses. As it condenses it falls into the bottom of the heater in the drain section of the heater. From the drain section of the heater the condensate (drips) is returned to the Deaerator. Heaters also use flue gas to heat the feedwater.
S Shariq Ahmed
Feedwater Heaters
Feedwater Heater Controls
The inlet and outlet feedwater valves to the Extraction Steam Feedwater Heaters on Units are manually operated valves.
S Shariq Ahmed
Feedwater Regulation
The objective of feed water control may seem simple : it is to supply enough water to the boiler to match the rate of evaporation.
S Shariq Ahmed
Feedwater Regulation
The Feedwater Regulation is controlled from the DCS (distributed control system) in the Control Rooms.
The Feedwater Regulation maintains a constant boiler drum level by regulating feedwater flow to the boiler drums. The system provides for drum level control from startup through the normal full operating load range.
S Shariq Ahmed
Feedwater Regulation
Feedwater Flow is controlled by two (2) separate modes of control:
Single element The single-element system responds to the drum level to control the level control valve. The level controller compares the drum level set point, set on the DCS to the actual drum level. The controller in AUTO generates a signal, which regulates the level control valve to maintain the drum level. In MANUAL the level is controlled by the operator. Three-element The three-element system utilizes measurements of steam flow, feedwater flow and drum level to control feedwater flow.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The level of water in the drum provides and immediate indication of the water contained by the boiler. If the mass flow of the water into the system is greater than the mass flow of steam out of it, the level of water in the drum rises and vice versa. As the level of water in the drum rises , the risk increases of water being carried over into the steam circuits.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
If the level of water falls there is a possibility of the boiler being damaged , partly because of the loss of essential cooling of the furnace water-walls. The target of feed water control system is to keep the level of water in the drum to approximately the midpoint of the vessel. The level of water is affected by transient changes of pressure within the drum and the sense in which the level varies is not necessarily related to the sense in which the feed flow must be adjusted.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Swell Shrinkage
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Swell Boiling water comprises a turbulent mass of fluid containing many steam bubbles, and as the boiling rate increases the quantity of bubbles which are generated also increases.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Swell The mixture of water and bubbles resemble foam, and the volume it occupies is dictated both by the quantity of water and by the amount of the steam bubbles within it. If the pressure within the system is decreased, the saturation temperature is also lowered and the boiling rate therefore increases.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Swell As the boiling rate increase, the density of water decreases, but since the mass of water and steam has not changed , the decrease in density must be accompanied by an increase in volume of the mixture.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Swell By this mechanism the level of water in the drum appears to rise a phenomenon referred to as SWELL. The rise of level is misleading, it is not indicative of the real increase in mass of the water of system, which would require the supply of water to be cut back to maintain the status quo.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Swell If the drop in pressure is the result of the steam demand suddenly increasing , the water supply will need to be increased to match the increased steam flow.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Shrinkage: It is the opposite of swell. It occurs when the pressure rises.
The mechanism is exactly the same as that for swell, but in the reverse direction.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Shrinkage: It causes the level of water in the drum to fall when the steam flow decreases, and once again the delivery of water to the boiler must be related to the actual need rather than to the possibly misleading indication provided by the drum level transmitter.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Shrinkage: The effect of swell and shrinkage in addition to being determined by the rate of change of pressure, also depends on the relative size of the drum and the pressure at which it operates.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Shrinkage: If the system pressure is low the effect will be larger than with a boiler operating at higher pressure, since the effect of a given pressure change on the density of water will be greater in the low pressure boiler than it would if the same pressure change were to occur in a boiler operating at higher pressure.
S Shariq Ahmed
Feedwater Regulation
Single Element Control
The situation arises due the following effects: Shrinkage: The simplest solution for these is implementation of a two element system since it is based on the use of two process measurements in place of the single drum-level measurements used.
S Shariq Ahmed
S Shariq Ahmed
Feedwater Regulation
Two element system
A valve with a linear characteristic is employed in conjunction with a transmitter that produces a signal proportional to steam flow. If the transmitter produces a signal which is equal to the steam flow at all loads and if the flow through the valve is matched with this signal at every point in the flow range, a controller gain of unity is will ensure that , throughout the dynamic range of the system, the flow of water will always be equal to the flow of steam.
The correct gain of the controller can be determined from a knowledge of the swell and shrinkage effects within the boiler.
S Shariq Ahmed
Feedwater Regulation
Two element system
Theoretically better results can be obtained by carrying out tests to determine the swell effect at various points in the load range and introducing a nonlinear function within the level controller to compensate for the differences across the range.
S Shariq Ahmed
S Shariq Ahmed
Feedwater Regulation
Three element system
In two element system it is assumed that the feed water valve characteristic is linear and the valve is sized to produce a fixed flow when it is 100% open. However the flow through the valve depends both on its opening and on the pressure drop across it. In a feed water system, the pressure drop across the valve varies from instant to instant, and the flow through it at any given opening will therefore vary.
S Shariq Ahmed
Feedwater Regulation
Three element system
The varying flow results in the level control becoming offset, to restore the steam flow/ feed flow balance. This offset is undesirable since it needlessly erodes the safety margin provided by the presence of the drum. One method of correcting this error produced by the feed valve is the addition of a third element to the system- a measurement of feed-water flow.
S Shariq Ahmed
Feedwater Regulation
Three element system
Ways of implementing a three element system are: 1st Method The output of the drum level controller is trimmed by a signal representing the difference between the feed flow and the steam flow signals. A gain block is introduced to compensate for any difference between the ranges of the two transmitters.
S Shariq Ahmed
Feedwater Regulation
Three element system
Ways of implementing a three element system are: 1st Method In most cases the steam flow and the feed flow signals will cancel out, and the drum level controller will be modulating the feed flow to keep the level at the set point.
S Shariq Ahmed
S Shariq Ahmed
Feedwater Regulation
Three element system
Ways of implementing a three element system are: 2nd Method In this method a cascading control technique is applied. The drum level controller compares the measured level signals with a set value and produces a bipolar output proportional to any error.
S Shariq Ahmed
Feedwater Regulation
Three element system
Ways of implementing a three element system are: 2nd Method This trims a modified steam flow signal , which is acting as the desired value for a closed loop feed water controller. As previously a gain block adjusts for any range difference between the steam flow and the feed flow transmitters.
S Shariq Ahmed
S Shariq Ahmed
Feedwater Regulation
Discrepancies between drum readings
Density errors- differences between installations can cause one instrument to be more affected by density factors than another. Turbulence- standing waves exists around the downcomers, affecting some measurement points more than the others. Flashing off- differences in the geometry of the measuring systems can cause some measurements to be more affected than the others by flashing off during the pressure changes.
S Shariq Ahmed
Feedwater Regulation
Discrepancies between drum readings
Calibration- it is vital that all the transmitters are carefully and accurately calibrated, and that any density compensation is correctly set up. Installation- errors or sluggish response can be the result of partial or complete plugging of impulse lines, or imperfect blow down operations.
S Shariq Ahmed
Feedwater Regulation
In AUTOMATIC, the steam flow is the primary signal to the drum level controller.
The drum level controller then compares drum level to drum level setpoint set on the DCS.
The output signal from the drum level controller is equal to steam flow if actual boiler drum level is equal to boiler drum level setpoint. An actual low boiler drum level is corrected by the drum level controller generating an output signal greater than steam flow.
S Shariq Ahmed
Feedwater Regulation
In AUTOMATIC, the steam flow is the primary signal to the drum level controller.
An actual high boiler drum level is corrected by the drum level controller generating an output signal less than steam flow.
Thus, the output of the drum level controller is the desired Feedwater flow, which is equal to steam flow if the actual boiler drum level is at setpoint.
S Shariq Ahmed
Feedwater Regulation
The feedwater controller then compares actual feedwater flow to the desired feedwater flow signal sent from the drum level controller. This arrangement provides immediate response in feedwater flow to changes in steam flow.
Feedwater Control Valve
S Shariq Ahmed
SYSTEM OPERATION
S Shariq Ahmed
System Startup
All system components that have been tagged out for maintenance have had tags cleared and removed.
All control and indication instrumentation on which maintenance or calibration has been preformed has been returned to service. The Instrument Air System is in service.
The system should be walked down to verify that all pump and motor lubrication are at their proper levels.
S Shariq Ahmed
System Startup
That the systems valves have been placed in their proper startup positions with all drains closed except where otherwise noted.
That all AC and DC electrical power supplies has been racked in and ready for service.
S Shariq Ahmed
Normal Operation
All systems should be monitored for pressures, temperatures, flows, and levels.
S Shariq Ahmed
System Shutdown
The Feedwater System is normally in operation. All pumps should be taken out of service and breakers racked out. Close valving to isolate the system and open drain valves where system needs draining. Any part of the Feedwater System is to be worked on, proper clearance and tagging should be obtained.
S Shariq Ahmed