DESIGN OF ISOLATED FOOTING

(Egyptian Code 1995)

ISOLATED FOOTING TYPE :

F1

DESIGN CRETARIA :
Charactrestic Strength Of Concrete
Charactrestic Strength Of Steel
Allowable Soil Capacity

250 Kg/Cm2
3600 Kg/Cm2
1.5 Kg/Cm2

COLUMN DATA :
Smaller Depth Of Col. (a)
Bigger Depth Of Col. (b)
Ultimate Column Load
Is Palne Concrete Active (YES or NO )
Thickness Of Plane Concrete

25 Cm
60 Cm
200 ton
YES
20 Cm

FOOTING :
Required Area Of P.C.
Breadth Of P.C (Bpc)
Length Of P.C (Lpc)
Ult. Stress Under R.C (qu)

8.889
2.85
3.20
29.155

m2
m
m
t/cm2

Area Of R.C
Breadth Of R.C
Length Of R.C

6.86 m2
2.45 m
2.8 m

ULTIMATE MOMENT :
Ult. Moment at Sec {1}
Ult. Moment at Sec {2}

41.980 m.t
36.732 m.t

B
SEC.{1}

a
Required Depth For Moment (d)
Applied Overall Depth (T)

41.394 Cm
60 Cm
L
SEC.{2}

CKECK SHEAR :
Allowable Shear Stress
SEC {3}
Ult. Shear Force
Ult. Shear Stress

SEC {4}
Ult. Shear Force
Ult. Shear Stress

96.825 t/m2
d
46.531 ton
52.888 t/m2
Safe

40.714 ton
58.641 t/m2
Safe

SEC.{3}

SEC.{4}

CKECK PUNCHING :
Cofficient
Allowable Punching Stress

Made By :AHMEDG

0.916667
118.341 t/m2

05/25/2014

d/2

Dr\Mohamed .S. Soliman Office

DESIGN OF ISOLATED FOOTING


(Egyptian Code 1995)

Ult. Punching Force


Ult. Punching Stress

174.303 ton
86.093 t/m2
Safe

d/2

AREA OF STEEL :
SEC {1}
Area Of Steel (As1)
Area Of Steel per meter (As1/m')
Diameter Of Bars
Category Number (Cn)
Reduction Factor (Bcr)
Required Area of Steel per meter (As/m')
Min. Area Of Steel
Total Area Of Steel (As)
Total Number Of Bars

26.832
9.583
13
1
1
9.583
6.780
26.832
22

Cm2
Cm2/m'
mm

SEC {2}
Area Of Steel (As1)
Area Of Steel per meter (As1/m')
Diameter Of Bars
Category Number (Cn)
Reduction Factor (Bcr)
Required Area of Steel per meter (As/m')
Min. Area Of Steel
Total Area Of Steel (As)
Total Number Of Bars

23.478
9.583
13
1
1
9.583
6.780
23.478
19

Cm2
Cm2/m'
mm

CHECK BOND :
Allowable Ulimate Bond Strength
Devloped Length

11.232 Kg/Cm2
50.95 Cm

Cm2/m'
Cm2/m'
Cm2

Cm2/m'
Cm2/m'
Cm2

(Hooked Bars)

SUMMARY OF DESIGN
Charactrestic Strength Of Concrete
Charactrestic Strength Of Steel
Allowable Soil Capacity

TYPE
F1

Length
3.2

Made By :AHMEDG

P.C
Breadth
2.85

Depth
0.2

Length
2.8

R.C
Breadth
2.45

05/25/2014

250 Kg/Cm2
3600 Kg/Cm2
1.5 Kg/Cm2

Depth
0.6

Area Of Steel
Remarks
Long.Dirc. Short.Dirc.
19 D 13
22 D 13

Dr\Mohamed .S. Soliman Office