DM Plant
DM Plant
DM Plant
3
4
5
INDEX
5) DEMINERALISATION SYSTEM………………………………………..
6) OPERATION OF DM PLANT……………………………………………..
7) MONITORING OF DM PLANT…………………………………………
6
1) RAW WATER & IMPURITIES:
Water is one of the basic requirements in raising steam. In nature water is available in
abundance. Its physical and chemical characteristics vary depending upon the source and
strata on which it flows. It picks up mineral salts from the soil, which go in to solution.
Water, therefore contains mineral salts in dissolved condition, in varying proportions,
composition and degree. It gets polluted further with multifarious organic and inorganic
impurities due to disposal of industrial and domestic wastes. Decayed vegetation and micro-
organism also contribute to contamination. Besides dissolved salts water contains coarse
substance in suspended form, constituting of silt and clay matters, generally termed as
turbidity. Silicate matters are present in dissolved as well as in colloidal forms, proportion of
which varies depending mainly on the following conditions:
- Temperature
- Seasonal Conditions
- Chemical characteristics of the particulate
- Velocity of the flow
Table 1 lists the major impurities of raw water, classed in three main groups: first, ionic and
dissolved, second non-ionic and undissolved and third gaseous. The ionic impurities in the
first group are sub divided in to cations and anions. Organic matter and colour appear in both
the first two groups, because there are many types: some dissolved and ionic, such as
hamates, and others colloidal and non-ionic, such as tannins. Also there may be types of
organic matter that are dissolved and non-ionic.
7
MAJOR IMPURITIES OF WATER:
HARDNESS
Alkalinity is of 3 types.
1. Bicarbonate Alkalinity
2. Carbonate Alkalinity
3. hydroxide or caustic Alkalinity
Total Alkalinity = HCO3 + CO3 + OH
Phenolphthalein Alkalinity (p Alk) is determined by titration with an acid and the colour change (pink to
colorless) takes place at pH of about 8.3.
Methyl Orange Alkalinity (M. Alkalinity):- During titration with an acid, the colour change takes place
at about pH of 4.3 (Orange to Pink)
8
2) METHOD OF EXPRESSING DISSOLVED IMPURITIES:
40
----- X 50 = 100 ppm as Caco3. (Here 20 is equivalent wt. of Ca)
20
9
3) IMPURITIES IN WATER, DIFFICULTIES CAUSED AND MEANS OF
TREATMENT:
10
4) PRE TREATMENT OF RAW WATER:
The purpose of pre treatment is to render raw water fit as influent to a de-mineralizing unit.
Pre treatment is done to make water free from suspended, colloidal and organic impurities.
Since presence of such impurities adversely affect the de-ionisation effect and the final
quality of de-mineralized water, pre-treatment plays a vital role in water treatment. The
different process involved in pre-treatment are:-
a) Settling and Coagulation
b) Filtration
a) SETTLING & COAGULATION:
Used for removal of turbidity and suspended matter. The coarse, heavy particles of
suspended matter gets easily removed by settling the water in a tank, but some suspended
impurities, such as turbidity, micro-organisms and colour are very finely divided or even in
colloidal form, so that they do not settle readily. Settling basins would have to be
excessively large, to remove these fine particles.
Co-agulation is a process of breaking up of a colloidal solution resulting in the recipitation of
the particle of the dispersed phase. It may be spontaneous and brought about by the additions
of an electrolyte which is termed as “coagulant”. Co-agulation, induced by adding chemicals
(Coagulants) to the water, agglomerates the finely divided, suspended solids in to masses that
settle more readily. This occurs in two ways:-
• The particles of turbidity and colour have like electric charges on their surfaces,
which keep them apart, because like electric charges repel one another and the co-
agulant ions selected possess charges opposite to those on the suspended particles, so
that they neutralize each other.
• The coagulant reacts with the alkalinity of the water to form a gelatinous precipitate,
called “floc” which enmeshes and entraps the finer of the suspended particles.
Alum or Aluminum sulphate is the most commonly used coagulant, because it is the
lowest in cost and least corrosive to handle. The reactions are shown below:-
Al2 (SO4)3 + 3 Ca (HCO3)2 = 2Al (OH) 3 + 3CaSO4 + 6CO2
11
The other coagulates are FeSO4 (Ferrous sulphate) and ferric sulphate {Fe2
(SO4)3}
Factors influencing coagulation:
• Organic matter, if present in appreciable amounts, inhibits coagulation and
narrows the optimal pH range. For the oxidation of organic matter pre
chlorination and narrows the optimal pH ranges. For the oxidation of organic
matter pre chlorination is desirable, because it broadens the optimal pH range and
there by makes the coagulation easier to control.
• If the alkalinity in the water is insufficient to react with the dose of co-agulant, the
pH is below the optimal range, and then the alkalinity must be increased by
adding an alkali. Lime is the cheapest alkali. For Al2 (SO4)3 optimum pH is from
5.5 to 7.5.
b) Filtration:
Filtration is defined as passage of fluid through a porous medium to remove matters held
in suspension. In water purification the matter to be removed includes:-
1. Suspended Silt
2. Clay
3. colloids
4. Micro Organisms including algae, bacteria and virus.
The particles to be removed have approximate size as follows:-
Material Particle Size, Milli-micron
Silt 50,000
Bacteria 5,000
Viruses 50
Colloids 1 – 1,000
12
5) DEMINERALISATION SYSTEM:
13
would result in a high degree of swelling and an accompanying gelatinous
structure having poor hydraulics properties.
• The design of commercial ion exchange resin is therefore involves a choice of
cross linking that represents a compromise between kinetic and hydraulic
performance.
Cation exchanger of the hydrogen type are either strongly acidic or weekly acidic.
Strongly acidic resins contain the sulfonic acidic functional group SO3H where as
weekly acidic resins contain carboxylic acidic group COOH.
Similarly there are weekly basic anion exchanger resins and strongly basic anion
exchanger resins. Strongly basic anion exchangers are again of two types, type I and
type II. Type I resins have less exchange capacity, but more stability than type II.
Type I have quaternary ammonium functional group. Type II has modified
quaternary ammonium functional group where one of the methyl groups is replaced
with an ethanol group.
The week base anion exchangers have polyamine functional groups containing
primary amine – NH2, secondary amine NHR and tertiary amines NR2.
14
3. SA-SB Low alkalinity raw Conductivity 5-15 Low equipment cost
water. SiO2 removal micro mhos/cm. SiO2 high chemical cost.
required. = 0.02-0.1
4. SA-D-SB High alkalinity of raw Conductivity 5-15 Low chemical cost.
water. SiO2 removal micro mhos/cm. SiO2
required. = 0.02 – 0.1
5. SA-WB-D-SB Higher alkalinity, SO4 Conductivity 5-15 Low chemical with
and Cl in raw water. micro mhos/cm. SiO2 high equipment cost.
SiO2 removal required. = 0.02-0.1
KEY
15
6) OPERATION OF DM PLANT:
A typical DM plant consists of cation, degasser and anion exchangers:
Introducing weak acid cation exchanger and weak base anion along with typical de-
mineralization chain and regenerating strong and weak exchangers by same acid/caustic
increase the efficiency of plant. Also having mixed bed for polishing ex-anion water
improves the quality of D.M. water to great extent.
OVERVIEW OF DM PLANT
Degasser
tower
Weak Strong
Raw water
Acid Acid
inlet
cation cation
Pressure
filter Degasser
tank
DM Water
storage tank
Weak
Strong
Ba se Mixed
Ba se
Anion Bed
anion
DM water supply to
unit
Degasser usually provided in between cation exchangers and anion exchangers to remove
carbon dioxide that decipates during ion exchange in cation exchangers.
The operating principles of weak acid cation exchanger (WAC), strong acid cation exchanger
(SAC), Degasser, Weak Base Anion Exchanger (NBA), Strong Base Anion Exchanger
(SBA) and mixed bed (MB) are discussed in following paragraphs.
16
Weak acid cation exchanger mainly removes Calcium & Magnesium alkalinity from
raw water. For simplicity cation resin is represented by H2R and equation for the service
cycle of WAC can be written as
Ca Ca
HCO3 + H2R -R + H2CO3
Mg Mg
Strong acid cation exchanger removes sulfates, chloride, nitrates and sodium salts. The
equation for service cycle of strong acid cation can be written as
Ca So4 Ca H2So4
Cl2 + H2R -R + HCl
Mg NO3 Mg HNO3
HCO3
CO3 H2C03
Na SO4 + H 2R NaR + H2So4
Cl2 HCl
NO3 HNO3
Process of exchanging salts in cation exchange continues till resin looses its capacity to
convert salts into corresponding acids. After this the resin to be regenerated by using
hydrochloric acid or sulfuric acid.
During regeneration resin will regain its capacity to exchange salts after which it can again
remove salts from water.
The equation for regeneration cycle can be written as follows:
Ca Ca
Mg R + HCl Mg Cl + RH
Na Na
17
Ca Ca
Mg R + H2So4 Mg So4 + RH
Na Na
Note: Strong Acid Cation Resin can also remove alkaline salts of Calcium & Magnesium.
However as WAC is precedes SAC, there won’t be any load of alkaline salts on SAC.
When Weak Acid Cation and Strong acid cation are in series regeneration is done in through
fare system. Acid after regenerating strong acid cation exchanger passes through weak acid
cation exchanger.
Normally conductivity is compared during the run. The conductivity ratio is normally
constant during the run. At the exhaustion the conductivity ratio changes indicating the
exhaustion.
Cation leakage is important because it affects the purity of the demineralizer effluent. A
strong base anion exchanger can remove only the acidity, not the sodium. It coverts the
18
sodium salts to sodium hydroxide, which creates a high conductivity and pH value in the
effluent. Therefore for a low conductivity of dematerialized water cation leakage (Na) must
be reduced. The several methods adopted area:-
1. Air Mixing of resin Regeneration.
2. Counter flow re-generation.
The CO2 generated if not removed increases load on SBA resin. So degassers or
Decarborators are placed in cation & anion.
Degassers usually made of acid proof materials (wood or rubber lined steel) as it have to
handle acidic water of cation exchangers. (Redwood or cypresses are usually preferred
woods).
Typical degasser as shown; air blown at the bottom and rises counter current to the
downward trickling water. The spray pipes or trays divide water into droplets or thin films
exposing new surfaces to gas phase. Tray also serves to agitate the water by splashing thus
allow dissolved gases to leave water readily. Agitation overcome tendency of water to retain
gas bubbles through surface tension and viscosity.
Height of the tray stack or Rasching ring proportional to amount of influent CO2.
Decarborators are designed with flow rates that range from 20 to 30 gal/min/sq.foot areas (1
to 1.5 m3/min/m2). The height of Rasching –ring varies from 5 to 15 ft.
19
Sectional view of degasser tower
20
6.4 WEAK BASE ANION EXCHANGER:
Weak base anion exchangers can remove only the highly dissociated acids (like H2So4,
HNO3, HCl) from the effluent of cation exchanger. They can not remove weakly dissociated
carbonic acid from alkalinity or silica acid from the silica content in the water.
Exhaustion reaction represented by equation.
H2SO4 SO4
2 HCl + 2ROH (NO3)2 2R + 2H2O
2HNO3 Na
The regenerates of weak base anion resins may be NaOH, Na2CO3 or NH3
Some typical application of WBA exchanger are mirror silvering, processing of ceramics,
deproofing or cutting of alcohol in distilleries, plating, glass manufacture and automobile
pointing.
6.5 STRONG BASE ANION EXCHANGER
This removes weakly dissociated and the strongly dissociated acids.
The reaction of strong base anion exchangers given in following equation:
H2SO4 SO4
2HCl + 2ROH Cl2 2R + 2H2O
2H2CO3 (Co3)2
Regeneration of Anion exchanger usually did by caustic soda. If weak base anion exchanger
& strong base anion exchanger are in series regeneration done in thoroughfare system.
Caustic soda after regenerating strong base anion exchanger passes through weak base anion
exchanger. Following equation represents regeneration equation.
SO4 Na2SO4
Cl2 2NaCl
(NO3)2 -2R + 2 NaOH 2 ROH + 2 Na (NO3)2
SiO3 Na2SiO3
CO3 Na2CO3
21
6.6 MIXED BED:
22
In mixed bed both strong cation and strong anion exchangers are in same shell, rather in
separate shells. They are mixed together by compressed air after regeneration. Cation and
anion particles being next to each other constitute a series of two bed pairs of beads.
Prior to regeneration the two resins are separated by backwashing. Due to density difference
between two types of beads, the two types of resins separate completely and settle one above
the other (cation in the bottom and anion at the top). A screened interface pipe system,
located between two resins, collects regenerate effluent. Acid usually follows upward and
caustic soda downward.
Cation Regeneration usually proceeds anion, but two may be simultaneously also. The
advantage of sequential regeneration is that the Calcium cations dissipated from the cation
resins before carbonate ions from Anion resins, formation of Calcium Carbonate precipitates
is avoided thus avoiding fouling of interface screening.
A downward blocking flow of water proceeds from top while acid flows upward. Both
blocking water as well as effluent acid escape through interface collector.
The blocking flow avoids expansion of bed and also prevents acid from entering anion bed
above interface.
An upward blocking flow of water or acid proceeds from bottom while caustic soda flows
downward, so that later does not enter cation resin.
Usually mixed bed used for polishing and follows a two bed pair.
23
7) MONITORING OF DM PLANT:
S.
DEFECTS CAUSES REMEDIES
NO.
a. Increase in ionic load Check by analysis
b. Flow integrator/indicator defective Check
c. Less amount of regenerant chemical
Check
used for regeneration
Decrease in
d. Resin fouled Give treatment for de-fouling
capacity
1 e. Plant being used intermittently Regular running
between two
Check and ensure uniform
regenerations f. Channeling in resin bed
distribution of bed
g. Resin dirty Give prolonged backwash
h. Resin deteriorated Check /replace the resin
i. Resin quantity become less Check and makeup the level
a. Cation exhausted Check and regenerate
b. Anion exhausted Check and regenerate
c. Mixed bed exhausted Check and regenerate
d. Resin in mixed bed not in mixed Again remix the resin by air and
state rinse.
e. Some valves particularly back wash
Check and rectify.
inlet valves passing
Check feed water analysis. Note
f. Sodium slip from cation high
changes in Na / TC and Silica /
Treated
TA ratios. Use more chemicals
water quality g. Silica slip from anion high
2 accordingly.
not as
specified h. Unit idle Check
i. Unit is not sufficiently rinsed Rinse it to satisfactory quantity.
Adjust the unit flow between
j. Excessive low flow rate minimum and maximum flow
rate.
Check and ensure uniform
k. Channeling of resin bed
distribution in bed.
l. Resin fouled Same as 1 (d ).
m. Resin deteriorated
Check the resin and replace.
a. Resin not separated during back Give extended backwash after
wash exhaustion of bed.
Mixed bed
b. Air mixing not proper Give extended air mixing.
3 quality not
c. Final rinse not proper Give extended final rinse.
good
d. Some valves may be leaking and
Check and rectify.
contaminating the treated water
24
a. Due to choked suction filter of Check and clean filter.
degassed air blower
High residual
CO2 from Check blower discharge valve /
4 degasser b. Improper air flow to degasser damper / speed of blower and it's
discharge pressure.
Check and take blower in line.
c. Degasser blower not in operation
.
Reduce air flow rate by adjusting
a. Very high air flow rate
Flooding in V/V
5
Degasser b. Packed tower choked due to dust Open, check, clean or replace
or broken packing material packing.
a. Flow rate too low Check and increase flow rate.
b. Backwash inlet valves not holding Check and rectify.
Unit rinse c. Anion resin organically fouled Give alkaline brine treatment.
6 takes long d. Mixed Bed air mix not satisfactory Carryout air mixing again.
time Faulty design, Check/rectify.
e. Acid or alkali pockets formed in
Temporarily give longer backwash
unit
and rinse again.
a. Choked valves or suction strainer
Check and rectify
of pump
Check water level in respective
Flow rate b. Cavitations in pump
tanks.
too low
c. Low inlet pressure Check water pressure.
7
d. Distribution or collector system
Check and clean
choked
e. Resin trap at outlet unit choked Check and clean
f. Control valves shut due to low off
Increase off take.
take.
a. Defective valves Check and rectify / replace.
Pressure Give extended backwash with open
b. Packing of resin bed due to fines of
drop across manhole, scrap fines from top of
8 resin
bed bed
increasing c. Collecting system choked Check and repeat backwash.
d. Pressure gauge defective Check and rectify / replace.
a. Due to excessive backwash Check inlet pressure and flow rate
pressure or flow. and reduce it if necessary.
Resin bed
9 Examine the system for any
being lost b. Faulty collection system
breakage.
c. Inlet strainer damaged Check and replace.
10 Ejector not a. Low power water pressure Check and adjust.
working b. Air lock in the unit Backwash and release air entrapped
in unit.
c. Choked or defective valves Examine and rectify
25
d. Ejector nozzle may be choked Check and clean.
Check for choking of regenerant
e. Too much back Pressure from unit distribution / collecting system.
Passing of inlet and outlet valves.
f. Bulge in rubber linking of pipeline Check and rectify.
Incorrect a. Choked orifice or impulse line Check and clean
11 reading from
b. Dirty glass or float Check and clean
rotameters.
26
8) OPTIMISATION OF DM PLANT OPERATION:
Regeneration system of cation / anion exchanger is normally two types based on regenerate
flow. When the flow of acid / caustic are in the same direction on the service flow the
Regeneration system is known as cocurrent regeneration. And when the flow of acid /
caustic are in opposite direction of service flow it is known as counter current regeneration.
Counter current regeneration have following advantages.
27
STRONG ACID CATION RESIN
Counter-current regeneration systems provide a water quality of better than 2 µ S/cm and
residual silica of 0.020 to 0.050 mg/l as SiO2. Depending upon water composition and
regeneration conditions, the specific conductivity could be as low as 0.2 µ S/cm. The
normal counter-current endpoint is 4 µ S/cm conductivity.
28
A maximum endpoint value of 0.3 mg/1 SiO2 above the average leakage should not be
exceeded in order to avoid a high contamination of the polishing resin layer and unacceptably
high silica leakage during subsequent cycles. Silica leakage can be minimized by operating
the plant at silica break rather than conductivity end point. This secures the lowest silica
leakage, but at the expense of a 5 – 10 % throughput reduction.
The plant configuration will depend on the feed water composition, the water quality
required and the economics of operation. The following general guidelines are given to help
in configuration and resin selection.
(A) [SAC] – [WBA]: This combination of strong acid cation [SAC] and weak base
anion [WBA] resins is used to obtain partially deionized water without removal of
CO2 and SiO2.
(B) [SAC] – [SBA]: The combination of strong acid cation and strong base anion [SBA]
is preferred for treating low mineralized water or for small size plants.
(C) [SAC] – [WBA] – [SBA] : This combination of strong acid cation with weak base
and strong base anions is proven to be an excellent choice for larger plants as it
provides an optimum balance between investment and running cost. It is well suited
to treat waters with low alkalinity, when the FMA (Cl + NO3 + SO4) is typically >
60% of the total anions. The normal end-point for a WBA resin corresponds to the
chloride breakthrough, which means that the downstream SBA resin is only
removing the carbon dioxide and silica ions. This situation generally leads to a big
discrepancy between WBA (large) and SBA (low) volumes.
(D) [WAC] – [SAC] – [SBA]: The use of a weak acid cation [WAC] in front of a strong
anion is preferred with feed waters containing a high proportion of temporary
hardness (>60%) and low FMA. The normal end-point for a WAC resin is 10%
alkalinity leak. In this condition, the down-stream SAC resin should remove the
permanent hardness and the monovalent cations. This situation generally leads to a
big discrepancy between WAC (large). This is the ideal combination for high
hardness, high alkalinity and high FMA water, as well as large size plants. Again
the cation and anion combinations can be in single or separate vessels.
29
(E) [WAC] – [SAC] – [WBA] – [SBA]: This is the ideal combination for high hardness,
high alkalinity & high FMA water, as well as large size plants. Again the Cation &
Anion combination can be single or separate vessel.
30