Record all work offsets.
Hold reset and delete key while powering up.
Parameter button- go to parameter 900 enter parameters 900-017 from the
record of inspection. A 000 alarm appears after entering the first parameter -go
back to parameters and enter the values for 901. When the next alarm appears
press delete
Enter remainder of 900 parameters. When finished, verify that all parameters are
entered correctly.
Power machine down for 10 seconds then power up
Go to parameter page #1 in MDI mode
ISO = 1
Inch = 1
Page down 3 times to parameter #2
Enter 0000 0011
Go to parameter # 552 set to 10
Place machine in edit mode and memory protect key off. With parameter
screen displayed push the Input Key
LSK should appear in the lower right corner.
From PC transmit the Kiwa.PAR file to the CNC. The CNC LSK should change
to INPUT. After the file is transmitted a number of alarms will appear.
Press Delete at alarm
Power Down/Up
Go to diagnostic page- Verify Diagnostics is displayed in the upper left corner.

4491 Foskuhl Rd.

Floyds Knobs, In. 47119

www.automacon.com

812-923-3718 (phone)

info@automacon.com

812-923-5396 (fax)

Automation
Consultants Inc.
"Sales, Service and Support for Modern Manufacturing"
Hold EOB in and push input
Transfer the Kiwa.dgn file
When finished go back to parameters and set PWE=0. Push reset (must be in
MDI mode)
All alarms should be cleared
Go to Edit mode and push the PGRM key until I/O is displayed. Push I/O then
read. LSK will appear again.
Transmit the Kiwa.PGM file to the CNC.
Push offset until tool offsets are displayed.
Press input.
LSK will appear
Transfer the Kiwa.off file
Verify all offsets.
Enter work offsets P1-P8 by hand.
Power down
Power up holding LQP and CANCLE key.
Move away form home position and zero out.