Anchor Bolt Placement - Crown-Weld Pole
Anchor Bolt Placement - Crown-Weld Pole
Anchor Bolt Placement - Crown-Weld Pole
Document
Drawing/Page
Figure 1
CI102X01R3
RKM
Date
DCR#
4/17/01
99-120
NOTES
1. Before pouring foundation, confirm that the pole base configuration
matches the masonite anchor bolt template. (See Table 1)
2. 5" (127 mm) and 6" (153 mm) square steel poles and 6" (153 mm)
square aluminum poles require a minimum 24" (610 mm) dia.
foundation. All other poles require a minimum 18" (457 mm) dia.
foundation.
Table 1
Clamping Nut
Leveling Nut
Figure 2
Steel Poles
Pole
3" (76 mm) sq.
4" (102 mm) sq x 10'
4" (102 mm) sq (15'-30')
5" (127 mm) sq
6" (153 mm) sq
4.5" (114 mm) Round
5.5" (140 mm) Round
Anchor
Bolt Size
3/4" (19 mm) x 18" (457 mm)
3/4" (19 mm) x 18" (457 mm)
3/4" (19 mm) x 30" (762 mm)
1" (25 mm) x 36" (914 mm)
1" (25 mm) x 36" (914 mm)
3/4" (19 mm) x18" (457 mm)
3/4" (19 mm) x 30" (762 mm)
Bolt
Circle
10" (254 mm)
10" (254 mm)
10" (254 mm)
10" (254 mm)
11.5" (292 mm)
8.5" (216 mm)
8.5" (216 mm)
Anchor
Bolt Size
1/2" (13 mm) x 12" (305 mm)
3/4" (19 mm) x 18" (457 mm)
1" (25 mm) x 36" (914 mm)
1" (25 mm) x 36" (914 mm)
Bolt
Circle
8" (203 mm)
9.25" (235 mm)
11.5" (292 mm)
13" (330.2 mm)
Aluminum Poles
Pole
3" (76 mm) sq
4" (102 mm) sq
5" (127 mm) sq
6" (153 mm) sq
Pole Shaft
Pole Base Plate
Electrical Conduit
3-3/8"3-5/8"
(86 mm - 92 mm)
Grade
Document
Drawing/Page
INSTALLATION INSTRUCTIONS
RECOMMENDED ANCHOR BOLT PLACEMENT
CI102X01R3
RKM
Date
DCR#
REINFORCEMENT REQUIREMENTS
1. All reinforcing bars to be ASTM A615 grade 60 (60,000 PSI min.
(413 MPa) yield strength).
2. All ties to have a minimum of 12" (305 mm) overlap
3. All vertical bars to stop 3" (76 mm) short of top and bottom of
foundation.
4. All ties to have 3" (76 mm) cover.
5. All concrete to have a minimum compressive strength of 3,000
PSI (21 MPa) at 28 days: 1-1/2" aggregate, 6-1/2% min. air
entrainment.
6. Consult local structural steel fabricator for fabrication.
Typical
Elevation
4/17/01
99-120