Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

WIRING INSTRUCTIONS

TITLE

BAND SAW

MILWAUKEE ELECTRIC TOOL CORP. 13135 WEST LISBON RD. BROOKFIELD, WIS.
YELLOW

DATE
Apr. 2005

BULLETIN
58-01-0762
BLACK

RED

LEFT BRUSH

WHITE
WHITE
RED

GREEN

YELLOW
SWITCHBOTTOM VIEW

WHITE

RIGHT BRUSH

WHITE

ROUTE SWITCH WIRES


HERE BEFORE INSERTING
CORD CLAMP.

BLACK

1/4" MINIMUM
PAST CORD
CLAMP.

SCHEMATIC
FROM THE BOTTOM LEFT FIELD TERMINAL,
ROUTE RED LEAD #5 ON TOP OF COIL IT
CONNECTS TO, TOWARD YELLOW LEAD #4.
HOLD WIRE #5 WITH INSULATOR 23-14-0020 AS
IT CROSSES THE FIELD GAP. WIRES #4 AND
#5 ARE TO EXIT MOTOR HOUSING INTO
HANDLES TOGETHER.
CONNECT WHITE BRUSH LEAD #6 TO THE TOP
LEFT FIELD TERMINAL. CONNECT WHITE BRUSH
LEAD #7 TO THE BOTTOM RIGHT FIELD TERMINAL. ROUTE WIRES #6 AND #7 ON TOP OF COIL
THEY CONNECT TO AND MAKE CONNECTIONS
TO THE BRUSH TUBES.

ROUTE WIRES
THROUGH TRAPS
AS SHOWN.
WIRES CAN BE IN
ANY ORDER.

YELLOW

RED

NOTE:
WATCH FOR
PINCHED WIRES
BEFORE CLOSING
HANDLES.
WHITE
LB

RB

WHITE

INSULATOR 23-14-0020
MOTOR HOUSING
BACK VIEW

WIRING SPECIFICATIONS
Wire
No.

Wire
Color

Origin or
Gauge

Length

White

Cord

4 1/2"

Component of cord assembly

Black

Cord

4 1/2"

Component of cord assembly

Green

Cord

9 1/4"

Component of cord. Strip 3/16" For T1.

Yellow

18 Ga.

16 1/2"

23-94-0022. Strip 3/16" for T3. Strip 5/16" and tin if ferrule is damaged.

Red

18 Ga.

20 1/2"

23-94-0021. Strip 3/16" for T3. Strip 5/16" and tin if ferrule is damaged.

White

18 Ga.

4 1/8"

23-94-0020. Strip 3/16" for T1 and T3

White

18 Ga.

4 1/8"

23-94-0020. Strip 3/16" for T1 and T3

NOTE:
All leads must be held to 1/8".
All lead lengths are before stripping.

Terminals, Connectors and 1 or 2 End Wire Preparation

BULK LEAD WIRE - BULLETIN NO. 58-01-0003

TERMINAL DESCRIPTION
Code

Part No.

T1
T2
T3

23-74-0900
23-74-0841
23-74-0045

Qnty.

2
1
4

Drwg. 3