Design of R.C. Column (Axially Loaded) : Provide 10-16#bars As Main Bars
Design of R.C. Column (Axially Loaded) : Provide 10-16#bars As Main Bars
Length of
column
l, m
4
Effective
length
Le, m
2.6
Column size
B, mm
D, mm
500
500
Load
P, kN
1000
Grade of
concrete
fck, N/mm2
20
Grade of
steel
fy, N/mm2
415
Area of
Area of
Gross Area
steel
concrete
Ag, mm2 Asc, mm2 Ac, mm2
250000
2000
248000
Capacity of Column
Pu, kN
2540.1
Load on column
Pu, kN
1500
Check
Capacity of colum is Greater than load on Column
Safe
Continue the Design
No of Bars
10
Spacing
mm
256
ALLY LOADED)
End condition of
column
Fixed-Fixed
Percentage
of steel
(assumed)
%
0.8
CHECK
It is SHORT COLUMN
and Axially Loaded
Dia of
Main Bar
mm
16
Dia of
lateral
ties
mm
8
Fixed-Fixed
Fixed-Hinged
Hinged-Hinged
20
25
30
35
40
45
50
250
415
500