Wind Load Calculations
Wind Load Calculations
Wind load is calculated following BNBC 1993. The assumed location of the
project is Chittagong. Basic wind speed is 280 kilometer per hour (80 m/sec)
.Exposure category is assumed A-III.
28/57.5=0.487 and
Now design wind pressures are calculated at different height for wind
perpendicular to building length and wind perpendicular to building width as
shown in Table A and Table B.
Cz
0.368
0.415
0.497
0.565
0.624
0.677
0.725
0.769
0.81
0.82
Sustained wind
pressure,
qz=CcC1CzVb2
(kN/m2)
1.36
1.54
1.84
2.09
2.31
2.51
2.68
2.85
3.00
3.03
CG
1.654
1.592
1.511
1.457
1.418
1.388
1.363
1.342
1.324
1.34
Design wind
pressure,
Pz=CGCpqz
(kN/m2)
3.42
3.72
4.22
4.63
4.98
5.29
5.56
5.80
6.03
6.18
Cz
Sustained wind
pressure,
qz=CcC1CzVb2
(kN/m2)
0.368
CG
1.654
Design wind
pressure,
Pz=CGCpqz
(kN/m2)
2.79
1.36
6
0.415
1.592
3.03
1.511
3.45
1.457
3.78
1.418
4.06
1.388
4.31
1.363
4.53
1.342
4.74
1.324
4.92
1.34
5.04
1.54
9
0.497
1.84
12
0.565
2.09
15
0.624
2.31
18
0.677
2.51
21
0.725
2.68
24
0.769
2.85
27
0.81
3.00
30
0.82
3.03