Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
151 views

Design Calculation

This document provides specifications for installing granite panels using steel support angles. It analyzes the load calculations and structural capacity for angles of size 130x40x5, 90x40x5, and 150x40x5 to support granite panels weighing 185N and 363N. Bolt shear capacity for 8mm bolts is also checked. All designed elements are found to have sufficient capacity based on allowable stress limits. The conclusion recommends angle sizes based on granite panel dimensions.

Uploaded by

Kilaru Hareesh
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views

Design Calculation

This document provides specifications for installing granite panels using steel support angles. It analyzes the load calculations and structural capacity for angles of size 130x40x5, 90x40x5, and 150x40x5 to support granite panels weighing 185N and 363N. Bolt shear capacity for 8mm bolts is also checked. All designed elements are found to have sufficient capacity based on allowable stress limits. The conclusion recommends angle sizes based on granite panel dimensions.

Uploaded by

Kilaru Hareesh
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

PROJECT:

LOCATION:
SUBJECT :

GRANITE PANEL INSTALLATION

DATE :

SEP. 28, 2015

GIVEN DATA :
A

FOR GRANITE PANEL(790X305X30)


1
UNIT WEIGHT =
2600 Kg/M
2
PANEL SCREEN DIMENSION
a)
HEIGHT =
790 mm
WIDTH =
305 mm
THICKNESS =
30 mm
3
VOLUME =
L x W x Thk
790x305X30
VOLUME = Vol=
7228500 mm
or Vol =
0.0072285 M
4

WEIGHT = WT.= UNIT WEIGHT x VOLUME


WT. =
2600 x 0.0072285
18.79 Kg x 9.81
184.37012 N
say WT. =
185 N

TYPICAL PANEL
130x40x5

PAGE

TYPICAL PANEL
90x40x5

FOR STEEL
1
YIELD STRESS Fy =
2
3

UNIT WEIGHT =
STRESS ALLOWABLES
SHEAR STRESS ( Fv )
BENDING ( Fb)
DEFLECTION ( def )

275 MPa or N/mm


40000 psi
7850 Kg/M

0.4Fy
0.66Fy
L
240
4
E (MODULUS OF ELASTICITY) =
CALCULATION

since Fy < 65000 psi


for none structural member
200000 MPa or N/mm

DESIGN FOR STEEL ANGLE (130x40x5)


Dead Weight of Granite
Weight of angle
Total laod

185 N
40 N
225 N

The above laod is sharing by two angles


Therefore load on angle=

PAGE

Ga = 40

112.5 N

AT SECTION xx
x

130
D

CAPACITY OF ANGLE
I=
b h
12
(130)(5)
12

b=
h=
c = 5/2 =

130
5
2.5

4
1354.167 mm
CHECK FOR BENDING, SHEAR AND DEFLECTION

fb =

Mc
I

BENDING
fb =

but M = Wt. ( s )
M = 113(130)
M=
14625 N-mm

14625 x 1.5
1354.1667

fb =

27 N/mm

ALLOW. Fb = 0.66Fy = 0.66(275)=


2

fv =

SHEAR

fv =
fv =

181.5 N/mm

P
A

WHERE P = WT. = 113 N


A = SECT. AREA = 130(5)
A=
650 mm

113
650
0.174 N/mm

ALLOW. Fv = 0.4Fy = 0.4(275)=


3

OK, LESS THAN ALLOW. Fb

OK, LESS THAN ALLOW. Fv


110 N/mm

DEFLECTION
def =

Pl
WHERE :
3EI
(113x130x130x130)
3(200000) 1354.1667
L=
P = WT. =
0.306 mm

ALLOW. DEF = L/240 = 130(240) = 0.5


0.5416667
mm
mm
THE def < ALLOW. DEF, OK

PAGE

130 mm
113 N

CHECK ON THE ANCHOR BOLTS


DL ( WT.)

113 N

Try use 8 mm () bolt

SHEAR DUE WT. ONLY


fv (bolts) = Rb
As

but As =

but Wt. = Rb

Rb =
Rb =

(d)
4
As = 3.141592654( 8 )
4
As =
50.27 mm

113
1
113 N

fv (bolts) =

805
113
50.27
fv (bolts) =
2.25 N/mm
OK, LESS THAN ALLOW. (0.4 X 275=110 N/mm )
E

DESIGN FOR STEEL ANGLE (90x40x5)


FOR GRANITE PANEL(790X305X30)
1
UNIT WEIGHT =
2600 Kg/M
2
PANEL SCREEN DIMENSION
a)
HEIGHT =
790 mm
WIDTH =
600 mm
THICKNESS =
30 mm
3
VOLUME =
L x W x Thk
600x790X30
VOLUME = Vol=
14220000 mm
or Vol =
0.01422 M
4

PAGE

WEIGHT = WT.= UNIT WEIGHT x VOLUME


WT. =
2600 x
0.01422
36.97 Kg x 9.81
362.69532 N
say WT. =
363 N

Dead Weight of Granite


Weight of angle
Total laod

363 N
30 N
393 N

The above laod is sharing by two angles


Therefore load on angle=

196.5 N

AT SECTION xx
x

90
F

CAPACITY OF ANGLE
I=
b h
12
(90)(5)
12

b=
h=
c = 5/2 =

90
5
2.5

4
937.5 mm
CHECK FOR BENDING, SHEAR AND DEFLECTION

fb =
BENDING

Mc
I

fb =

17685 x 1.5
937.5

fb =

47.16 N/mm

ALLOW. Fb = 0.66Fy = 0.66(275)=


PAGE

but M = Wt. ( s )
M = 197(90)
M=
17685 N-mm

OK, LESS THAN ALLOW. Fb

181.5 N/mm

fv =

SHEAR

fv =
fv =

P
A
197
450
0.438 N/mm

ALLOW. Fv = 0.4Fy = 0.4(275)=


3

WHERE P = WT. = 197 N


A = SECT. AREA = 90(5)
A=
450 mm

OK, LESS THAN ALLOW. Fv


110 N/mm

DEFLECTION
P l3
3EI
(197x90x90x90)
3(200000) 937.5

def =

WHERE :

L=
P = WT. =

90 mm
197 N

0.255 mm
ALLOW. DEF = L/240 = 90(240) = 0.5 mm0.375 mm
THE def < ALLOW. DEF, OK

CHECK ON THE ANCHOR BOLTS


DL ( WT.)

197 N

Try use 8 mm () bolt


5

SHEAR DUE WT. ONLY


fv (bolts) = Rb
As
but Wt. = Rb

Rb =
Rb =
fv (bolts) =

but As =

(d)
4
As = 3.141592654( 8 )
4
As =
50.27 mm

197
1
197 N

805
113
50.27
fv (bolts) =
3.92 N/mm
OK, LESS THAN ALLOW. (0.4 X 275=110 N/mm )
PAGE

CHECKING FOR CAPACITY OF HORIZONTAL CHANNEL SCETION(40X20X3)

Loads Considered
Self weight of Channel
W

Case 1
Moment

197.00 N
113.00 N
40 N

a
b
l

150 mm
450 mm
600 mm

197.00 N
Wab/l
KNm

22162.5

Nmm

Case 1
Moment
W

113.00 N
12712.5 Nmm

Total Moment

I=

34875 Nmm
0.034875 KNm

b h
12
(600)(40)
12

b=
h=
c = 5/2 =

600
40
20

4
3200000 mm
CHECK FOR BENDING, SHEAR AND DEFLECTION

fb =
BENDING
fb =

Mc
I

but M = Wt. ( s )
M = 3200000
M=
34875 N-mm

34875 x 20
3200000

fb = 0.2179688 N/mm
ALLOW. Fb = 0.66Fy = 0.66(275)=
PAGE

OK, LESS THAN ALLOW. Fb

181.5 N/mm

Design of Angle (150x40x5)

TYPICAL PLAN OF ANGLES


Laods coming on Angle

Total Weight
This load is taking by two Angles

PAGE

197.00 N
113.00 N

Weight of granite
Weight of granite
Extra Loads from All
connections

100 N
410.00 N
205

AT SECTION xx
x

20

150
I

CAPACITY OF ANGLE
I=
b h
12
(150)(20)
12

b=
h=
c = 5/2 =

150
20
10

4
100000 mm
CHECK FOR BENDING, SHEAR AND DEFLECTION

fb =

Mc
I

fb =

30750 x 1.5
100000

BENDING

fb =

3.075 N/mm

ALLOW. Fb = 0.66Fy = 0.66(275)=


2

fv =

SHEAR

fv =
fv =

OK, LESS THAN ALLOW. Fb

181.5 N/mm

P
A

WHERE P = WT. = 205 N


A = SECT. AREA = 150(20)
A=
3000 mm

205
3000
0.068 N/mm

ALLOW. Fv = 0.4Fy = 0.4(275)=


3

but M = Wt. ( s )
M = 205(150)
M=
30750 N-mm

OK, LESS THAN ALLOW. Fv


110 N/mm

DEFLECTION
def =

Pl
3EI
(210x150x150x150)
3(200000) 100000

WHERE :

L=
P = WT. =

0.012 mm
ALLOW. DEF = L/240 = 130(240) = 0.5 mm0.625 mm
THE def < ALLOW. DEF, OK

PAGE

150 mm
210 N

CONCLUSION
a
b
c

Use 90x40x5mm angles with panel size not exceeding as mentioned above
Use 40x40x5mm angles with panel size not exceeding as mentioned above
Use 8 mm SS Bolts with embedded length of minimum 150 mm