Problem Set 2
Problem Set 2
PROBLEM 1:
A rectangular footing having a thickness of 0.75 m is supporting a 500mm x 500mm column
loaded with a downward force of
1750 KN
and a moment of
transverse axis of the footing base. The maximum and minimum net soil pressure under the
footing are 285 KPa and 22 KPa, respectively. Determine the minimum dimensions of the footing
(in multiples of 0.10 m). Check the footings adequacy with respect to shear requirements and
determine the required steel reinforcements in the long and short direction and within the
bandwidth of the footing. Use fc = 21 MPa,
reinforcements.
PROBLEM 2:
A part of column layout is shown in the figure with corresponding column spacing and location of
the property lines. Design the footing for the remaining four columns (C21 to C24) using the
following criteria stated below.
Allowable soil pressure
f c
fy
Minimum concrete cover
Rebar diameter
Minimum gap/spacing between
Columns
Size
C21
400mm
C22
450mm
C23
400mm
C24
450mm
footings
x
x
x
x
400mm
450mm
400mm
450mm
250 KPa
21 MPa
350 MPa
75 mm
25 mm
1.5 m
Dead Load
1010 KN
1175 KN
1000 KN
1100 KN
Live Load
410 KN
625 KN
600 KN
700 KN
Design Procedure:
1. Provide footing starting from column C21, then C22 until C24.
2. Try first a square footing. If square will not be possible, try rectangular. If rectangular
footing will not be possible then try rectangular combined footing.
3. Design the dimensions of length and width in multiples of 0.25 m and for the effective
depth and thickness in multiples of 5 mm.
4. Determine the number of longitudinal and transverse reinforcements for each footing.
5. After the final design, sketch the layout of the design footing together with the column
layout. Show their proper orientation and label the dimension of each footing.
HINT: You should be able to design 1 square, 1 rectangle, and 1 rectangular combined footing.
C18
C17
C19
C20
3.00 m
C21
C22
C23
C24
1.45 m
1.45 m
4.00 m
3.75 m
5.00 m
0.65 m
ANSWERS
1) L = 3.60 m, W = 3.20 m, long direction: Vub = 700.58 kN, Vup = 1183.68 kN, short direction: : Vub =
706.84 kN, Vup = 1193.40 kN, no. of main bars = 35, no. of temp and shrinkage bars = 19, no. of
bars in bandwidth = 17
2) For C21: Use 2.75 m by 2.25 m rectangular footing. For C22: Use 2.75 m by 2.75 m square footing.
For C23 and C24: Use 5.75 m by 2.5 m rectangular combined footing.