12-UT Defect Sizing
12-UT Defect Sizing
DEFECT SIZING
It cannot be used to assess flaws which are larger than the cross-section of the
ultrasonic beam because there will be total extinction of the backwall echo. Nor is it
suitable for assessing very small flaws from which the ratio of flaw to backwall echo
would be very small. The method can be adapted to take some account of the
attenuating effect of depth by reference to a predetermined beam profile but this is
not normally done.
Despite these limitations the method is widely used to assess flaws as in the case of
porosity levels in semi products such as blooms intended for forging applications.
The method is applied by first locating the flaw and optimising the probe position to
give the maximum flaw echo. The detector sensitivity is then adjusted to bring the
back wall echo to a predetermined level, usually 80% or 100% of the full screen
height. The ratio of the flaw echo amplitude to the backwall echo amplitude is
determined as shown in Fig. 1 (a).
ASSESSMENT OF FLAW SEVERITY USING THE BACKWALL ECHO
Obviously
the
method
relies on
the
Figure 1
component under test having a plane back surface lying parallel to the entry surface
to produce a backwall echo. It can be undertaken with longitudinal or shear wave
probes, although with most component shapes the absence of a back wall echo from
shear wave probes makes it more suited for use with longitudinal wave probes.
The 6dB Drop Method
This is a relatively simple method which can be used to delineate a large flaw such
as a lamination or cavity. It is best undertaken using a detector equipped with a
calibrated attenuator.
The method is based on the fact that a 50% drop in the energy received by a probe
is equivalent to a 6dB drop in sensitivity. Imagine a lamination which is larger than
the beam width. When the probe is located fully over the flaw as in Fig. 2 (a) then
the CRT display shows only an echo from the flaw.
THE 6dB DROP METHOD
Figure 2
As the probe is moved over the edge of the flaw some of the energy travels past the
flaw to the backwall. The flaw echo height falls and a backwall echo rises. A position
is achieved where half the energy is reflected from the flaw and half from the
backwall. At this position shown in 2 (b) the probe centre should coincide with the
edge of the defect. This position can be achieved in one of two ways by observation
of the CRT display.
In the first procedure the probe is positioned fully over the flaw and the flaw echo
height adjusted to a selected height i.e., 50% or 80% of full screen deflection. Using
the calibrated attenuator the sensitivity is increased by 6dB. The probe is then
moved off the defect until the flaw echo falls to the previously selected height. The
probe centre is then over the edge of the defect.
In the second procedure the flaw echo height is set initially to 80% of the full screen
deflection. The probe is then moved off the defect until the flaw echo falls to 40% of
the full screen deflection.
The second procedure is useful when a calibrated attenuator is not available, but in
order to achieve good accuracy the amplifier must be linear over the screen
deflection range used.
12.3.3 The 20dB Drop Method
This method is similar to that described in 12 3.2 And can be used to delineate large
flaws.
The method is based on the suggestion that as the probe is moved off the defect to a
position where a 20dB drop occurs in the flaw echo amplitude then the edge of the
probe is coincident with the edge of the defect, as shown in Fig. 3.
THE 20 dB DROP METHOD
The method is applied by Initially
locating the probe fully over the defect
(at a). The sensitivity is Adjusted such
that the flaw echo amplitude is at a
preselected height on the CRT screen,
eg., 50%. The sensitivity is increased by
20dB using the calibrated attenuator
and the probe is then moved off the
defect to a position (b) at which the flaw
echo returns to the preselected height
on the
CRT. The
trailing edge of the probe is then
considered to be coincide with the edge
the defect.
When using this method it is preferable to check the probe beam profile prior to
testing and confine the probes used to those with the large diameter and higher
frequencies to reduce beam spread.
The use of the 6dB and 20dB methods is not restricted to flaw sizes greater than the
probe diameter but can be used to assess smaller defects provided there is a
measurable probe movement but as defect size decreases the inaccuracy becomes
greater.
12.4 Methods using Reference Blocks
The use of reference blocks containing artificial reflectors to provide comparisons for
natural flaws is becoming more widespread. There are certain advantages in using
such blocks as they can be manufactured from material similar in composition, heat
treatment, thickness and surface condition to that of the components to be tested.
Artificial flaws can be introduced into these blocks as and where required to simulate
the size of natural defects which would be harmful in the component under test.
They will normally take the form of drilled holes, parallel or normal to the beam axis.
Those normal to the beam axis will most frequently have flat ends.
A block is usually prepared with the artificial reflectors located at different depth
levels in order that a test sensitivity can be set and a distance amplitude curse
(D.A.C.) established to calibrate the equipment for attenuation losses in the material
and the characteristics of the probe being used.
This is not strictly a true defect sizing method but a method of excluding
unacceptable defect sizes.
Alternatively the block may be prepared with holes of different diameters and depths
to allow a family of D.A.C. to be established. An estimate of defect sizes can then be
made.
12.5 The AVG Method (D.G.S. Method)
This is a universally established method of describing the response of natural flaws
in terms of the size of equivalent circular reflectors.
Although it is seldom possible to describe the true size of a natural flaw because of
the several unknown variables which affect its response this method has the
advantage of being able to provide reproducible results amongst different operators
and therefore creates confidence and credibility in the test.
The basis of the method is the A.V.G. diagram as illustrated in Fig. 4 which shows
graphically the dependence on distance of the echo amplitudes from a series of
perfectly orientated circular reflectors in an attenuation free medium.
A - the reduced distance to the flaw is related to V - the gain and G - the reduced
flaw dimension so that the diagram can be applied to various probes having different
characteristics.
Figure 4
Decibels
The unit for measuring the ratio of sound intensities is the bel. In practice this unit is
too large so it is divided by 10 to give the decibel. The bel is the logarithm of the ratio
of two intensities, so a decibel is a tenth of the logarithm. The difference between
two sound intensities is the gain measured in dB.
D1
dB
to the probe.
of the
Example
Find the difference in gain between 3/64" and 5/64" Dia FBH
GAIN = 40 log D1 dB
D2
= 40 log 5 dB
3
= 9dB approx
CHAPTER #______
Tutor Assessed Assignment
Name_______________
Date________________
Personal Number_____12______
Number of Pages____________
Answer the questions on the adjoining
pages then,
Return this assignment to TSC&A.
Comments:-
NAME___________________________DATE__________________
1.
2.
3.
4.
The scattering of the rays of an ultrasonic beam due to reflection
highly irregular surface is called:
from
a) Angulation
b) Dispersion
c) Refraction
d) Rarefaction
5.
In general, which of the following modes of vibration would
greatest penetrating power in coarse grained material
if the frequency of the waves are the same?
have
a) Longitudinal
b) Shear
c) Transverse
d) All of the above waves would have the same penetrating
6.
Which of the following frequencies would probably result in
ultrasonic attenuation losses?
a) 1.0 MHZ
the
power.
the
greatest
b) 2.25 MHZ
c) 10 MHZ
d) 25 MHZ
7.
When inspecting a rolled or forged surface with a thin scale
that is generally tightly adhering to the part, what is
necessary
before testing the part?
a) Clean the surface of loose scale
b) Have all scale removed
c) Rough machine the surface
d) Caustic etch the surface
8.
Which ultrasonic test frequency would probably provide the
penetration in a 12 inch thick specimen of coarse
grained steel?
a) 2.25 MHZ
b) 1 MHZ
c) 5 MHZ
d) 10 MHZ
9.
10.
best
to
do