NT Build 485 (Edition 2)
NT Build 485 (Edition 2)
NT Build 485 (Edition 2)
NT BUILD 485
CONTENTS
FOREWORD
Foreword
Scope
Normative references
Definitions
Principle
Apparatus
Sampling
Test specimens
Procedure
10 Test Report
Precision (informative)
Telephone +47 47 61 44 00
Fax +47 22 56 55 65
info@nordicinnovation.net
www.nordicinnovation.net
ISSN: 14592762
Project: 04014 (1624-03)
NT BUILD 485
Edition 2
Approved 2004-11
1(6)
NORDTEST METHOD
SCOPE
NORMATIVE REFERENCES
EN 933-2
NT BUILD 485
PRINCIPLE
APPARATUS
5.1
5.2
5.3
capacity.
5.4
low temperature cabinet, (upright or chest) with
air circulation. The cabinet shall be automatically controlled
to adhere to the temperature curve shown in Figure 1. The
sample temperature in the thawing out phase can be
controlled either by air circulation or immersion of sample
cans in a 20C water bath. A manual method of control may
be used, provided the correct cooling curve, as shown in
Figure 1, is adhered to. In the case of a dispute, the
automatic control shall be used.
5.5
DEFINITIONS
3.1
Test specimen
3.2
Laboratory sample
3.3
5.6
5.7
Constant mass
SAMPLING
NORDTEST METHOD
NT BUILD 485
TEST SPECIMENS
7.1
General
7.2
8.2
Check that the water or salt solution level in each can is still
at least 10 mm above the top of the test portion and place
the lids on the cans. Place the covered cans containing the
test portions in the cabinet, ensuring that the heat is
extracted from them as uniformly as possible from all sides.
The distance between adjacent cans and the sidewalls of
the cabinet shall be not less than 50 mm and the cans shall
not be touching.
The samples in the cabinet shall then be subjected to a
series of 10 freeze-thaw cycles as follows:
a) the temperature at the centre of a can, filled with
aggregate and water or NaCl solution as specified in 8.2
and situated in the centre of the cooled area, shall be the
reference measuring point of temperature.
Aggregate
size
mm
48
816
1632
3263
1)
Lightweight aggregate
(bulk volume)
ml
1000
2000
40001)
60001)
500
1000
1500
7.3
25
20
15
Temperature, C
10
5
0
-5
-1 0
-1 5
PROCEDURE
8.1
Soaking
-2 0
-2 5
0
10
12
14
16
18
20
22
24
T im e , h o u r s
NORDTEST METHOD
NT BUILD 485
8.3
On completion of the tenth cycle, empty each can
into a suitable container, and wash thoroughly by hand with
water. Dry each test specimen to constant mass and sieve
on a test sieve having an aperture size that is half the lower
size sieve used to prepare the test portion (e.g. of 4 mm
aperture size when testing 816 mm sample). Cool the
sample to ambient temperature and weigh immediately (M2).
9.1
9.2
10
TEST REPORT
The test report shall refer to this Standard and contain the
following information:
F = [(M1 M2)/M1]X100
where
M1 is the initial dry mass of the three test specimens before
cycling, in grams;
M2 is the final dry mass of the three test specimens after
cycling, that is retained on the specified sieve, in grams;
F is the percentage loss in mass of the three test
specimens after freeze-thaw cycling.
NOTE: A statement on the precision of this test is given in the
Appendix.
10.5
NORDTEST METHOD
NT BUILD 485
APPENDIX
Return address:
Nordic Innovation Centre,
Stensberggata 25
NO-0170 Oslo, Norway
NORDTEST
NORDTEST is a Nordic Innovation Centre
brand offering competence and expertice
in the field of harmonizing of norms and
methods,a large Nordic net-work of experts,
more than 650 recommended Nordic testing
methods and 550 published technical reports.
www.nordicinnovation.net