Pressure Drop of Y-Strainer
Pressure Drop of Y-Strainer
Pressure Drop of Y-Strainer
Cv Value of Y-Strainer
Size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3"
Cv 8 9.5 18 30.5 41.4 68 102 138
The Cv factor is a physical measurement specifies the number of gallons per minute (GPM) that can
pass through a piping component (Y-Strainer) with 1 psi pressure drop across the piping component.
These factors are based upon clean screens (20 mesh) handling water.
Pressure Drop in psi at 900 , 1700 and 3400 SCFM - Inlet Air Pressure 100, 150 and 200 psi
Size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3"
100 12.18 4.09 2.22 0.80 0.36 0.20
900SCFM 150 11.90 4.06 2.20 0.80 0.36 0.20
200 11.78 4.05 2.20 0.80 0.36 0.20
100 8.16 2.90 1.31 0.71
1700SCFM 150 8.05 2.89 1.31 0.71
200 8.00 2.87 1.31 0.71
100 12.16 5.32 2.86
3400SCFM 150 11.90 5.26 2.84
200 11.77 5.25 2.83
Pressure Drop in psi at 900 , 1700 and 3400 SCFM - Inlet Gas Pressure 100, 150 and 200 psi
Size 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3"
100 10.12 3.422 1.86 0.68 0.30 0.01
900SCFM 150 9.95 3.41 1.86 0.68 0.30 0.01
200 9.86 3.39 1.86 0.67 0.30 0.01
100 12.83 6.82 2.44 1.09 0.59
1700SCFM 150 12.53 6.73 2.42 1.09 0.59
200 12.40 6.70 2.42 1.09 0.59
100 10.12 4.45 2.39
3400SCFM 150 9.93 4.41 2.38
200 9.85 4.39 2.38
Note! Pressure Drops above 1 bar or 14-15 psi are in general not relevant.
Pressure Drop for Air at 900 SCFM
14
12
10 1"
dp (psi)
8
6 1-1/4"
4 1-1/2"
2
0
100 150 200
Inlet Pressure (psi)
10
8
1-1/2"
dp (psi)
6
2"
4
2-1/2"
2
0
100 150 200
Inlet Pressure (psi)
14
12
10 2"
dp (psi)
8
6 2-1/2"
4 3"
2
0
100 150 200
Inlet Pressure (psi)
Pressure Drop for Gas at 900 SCFM
12
10
1"
dp (psi)
8
6 1-1/4"
4 1-1/2"
2
0
100 150 200
Inlet Pressure (psi)
14
12 1-1/4"
10
dp (psi)
8 1-1/2"
6 2"
4
2 2-1/2"
0
100 150 200
Inlet Pressure (psi)
12
10
2"
dp (psi)
8
6 2-1/2"
4 3"
2
0
100 150 200
Inlet Pressure (psi)