HYSYS Tutorial 5 Examples
HYSYS Tutorial 5 Examples
James M. Lee
HYSYS is an interactive process engineering and simulation program. It is powerful program
that you can use to solve all kinds of process related problems. However, since you have to
provide various conditions and choices in order to solve a problem, you cannot use it effectively
unless you have good knowledge about the process and the solution procedures. The objective of
this class is to introduce you to the program so that you can use it as you take core chemical
engineering courses in the future.
You can find all kinds of documentation (tutorials, manuals, examples, etc) from the
following web site:
http://www.hyprotech.com/hysys/support/index.html - HYSYS%20Documentation
You can find numerous other resources by searching the web. You search results will
include many course web sites of other chemical engineering departments. Let’s start with
simple examples to find out how HYSYS works.
10. Click Separator in PFD. Choose the name of the Inlet as Cooled, the Vapor as Top, and
the Liquid as Bottom. Close the window.
11. Arrange streams in PFD so that it looks orderly as shown in the figure below.
12. Now click at the top of the HYSYS window to open Workbook. Check the units to
see if it is in English units. Otherwise, change the unit by clicking
Tools/Preferences/Variables. Choose Field as your choice and close the window.
13. Now fill in the Workbook with all the given condition, starting from the inlet stream:
temperature (50), pressure (14.7), and molar flow (100). Double click 100 (molar flow
rate), and composition window will be opened. Fill in the composition and close. As you
fill in the conditions, HYSYS will calculate the rest of the shell.
14. Continue to fill in the pressure (50) of the Compressed stream, temperature (32) and
pressure (50) of the Cooled stream. Now the calculation is complete as shown in the table
below. If you want to know the composition of the Top stream, double click 23.48 (molar
flow rate of the Top stream.)
HYSYS 3
General Reactor , three different reactors will pop up, click conversion reactor and
click it on PFD. Do the same for the Cooler and Separator.
6. Name inlets and outlets of all process units as shown in PFD diagram on the next page
(See the previous example if you don’t know how to do this.)
7. You will notice that the reactor is colored red with the error message, “Need a reaction
set.” Now we need to input what the reaction is.
Click Flowsheet/Reaction Package. Add Global Rxn Set. Then, click Add Rxn at the
lower right side of the window and choose Conversion. Add three components
(n-Heptane, Toluene, Hydrogen) and Stoich Coeff (-1, 1, 4). Click Basis page, and type
15 for Co (this is the conversion). Close windows until you see PFD.
8. Double click reactor. Choose Global Rxn Set as Reaction set and close the window.
9. Now, open worksheet , and type in all the know conditions for the streams as shown
in the worksheet below. Note that only blue colored fonts are the values that you
specified. If you more information than the degree of freedom allows, it will give you
error messages.
HYSYS 4
6. You can change the Pre-Heat stream temperature and see how it affects the H-Duty and
UA (heat transfer coefficient × interfacial area). Increasing Pre-Heat temperature can
reduce the H-Duty, but it will increase UA, which means that you need a heat exchanger
with more interfacial area (bigger and with more inner pipes). Obviously, there will be
upper limit of Pre-Heat temperature no matter how good your heat exchanger is. You can
see this effect by changing the temperature and recording the change of other values. Th
is can be done by using Databook function (under the Tools pull down menu.). The
process can be described as follows:
a. Open Tools/Databook. Click Insert button and choose Pre-Heat as object,
Temperature as Variable and click Add button. Do the same for Heat-Duty as
object, Heat Flow as Variable and Heat Exch as object, UA as Variable. Close
the window.
b. Go to the Case Studies page and click Add. Check Ind (Independent variable)
for Pre-Heat and check Dep (Dependant variable) for Heat-Duty and Heat
Exch. Click View. Type in 500 for Low Bound, 620 for High Bound, and 10 for
Step Size.
c. Click Start. After a few seconds, click Results.
HYSYS 6
4. Click Flowsheet/Reaction Package. Add Global Rxn Set. Then, click Add Rxn at the
lower right side of the window and choose Conversion. Add three components (ethylene,
hydrogen_chloride, and ethyl_chloride) and Stoich Coeff (−1, −1, 1). Click Basis page,
and type 90 for Co for Ethylene as a basis. Close windows until you see PFD.
5. Double click the Conversion Reactor. Choose Global Rxn Set as Reaction set and close
the window.
HYSYS 7
6. Double click the Recycle and set your Prameter/Tolerance to be all “1.”
7. Since it was assumed that the components were separated perfectly, ethyl chloride was
recovered in the bottom at 100% purity, with the other three components in the overhead
product. This can be specified by double clicking Component Splitter and Clicking Splits
(Under Design) and filling in 0 for ClC2 and 1’s for other three components.
8. Now open Workbook. Check the units to see if it is in SI units. Otherwise, change the unit
by clicking Tools/Preferences/Variables. Choose SI and click Clone and change the units
so that it is most convenient to you.
9. Fill in the Workbook with all the given condition, starting from the Feed stream:
temperature (25°C), pressure (1 atm), and molar flow (100 kmol/hr). Double click 100
(molar flow rate), and fill in the composition and close.
10. Continue to fill in the Workbook for the R* stream with the flow rate of zero and the
condition and composition equal to those of the feed, to allow computations to proceed.
Fill in the temperature (25 °C) of the streams S3, S4, and P. Fill in the pressure (1 atm) of
the streams S4 and P.
11. Specify the molar flow rate of the stream of W to be 10 kmol/hr. Now you can open the
Worksheet to see the result of the calculation as shown below.
12. As in Example 3, the Case Study option in the Datebook can be used to investigate the
impact of the purge flow rate on the recycle flow rate, reactor feed composition, and
amount of unused reactants in W stream.
HYSYS 8
Example 5: Distillation
We need to separate a mixture of five paraffins into light and heavy fraction by using
multistage distillation column with 12 ideal trays, a total reflux condenser, and a reboiler.
The feed stream (1000 lbmols/hr) consists of 3% (mole %) ethane, 20% propane, 37% n-
butane, 35% n-pentane, and 5% n-hexane at 225 °F and 250 psia, which enters the column on
the seventh tray, counting from the top. The condenser and reboiler pressures are 248 and
252 psia, respectively. The preliminary design specifications require a reflux ratio of 6.06
and a vapor overhead product of 226 lbmol/hr. Subsequently, the design is modified to
ensure propane overhead recovery of 191 lbmol/hr and butane bottom recovery of 365
lbmol/hr.
Solution
1. Start HYSYS and choose SRK as Base Property Package. Open Component page of
Fluid Package window and add components and close the Fluid Package.
2. Click Enter Simulation Environment and click Distillation Column in the Object
Palette and click it on Process Flow Diagram (PFD). Double click Distillation Column,
and fill in the stream names as C-Duty, R-Duty, F for Feed, D for Distillate), and B for
Bottom. Fill in # Stages = 12 and Inlet Stages 8_Main. Choose the condenser type as Full
Reflux. Click Next.
3. Fill in Condenser and Reboiler pressures as given in the problem and click Next.
4. Fill in Optional Condenser and Reboiler Temperature Estimate. Good estimates are 100
°F for Condenser and 240 °F for Reboiler. The HYSYS will calculate the correct values.
Click Next.
5. Fill in Vapor Rate of 226 and Reflux Ratio of 6.06. Click Done and close Distillation
Input Expert window.
6. Open Worksheet and fill in F stream as given in the problem.
7. Double click the column on PFD and click Run. If you followed all the direction
correctly, it should converge. Now you can turn various pages to see the results of the
calculation.
8. Now, as stated in the problem, we need to ensure that propane overhead recovery must be
191 lbmol/hr and butane bottoms recovery must be 365 lbmol/hr. This can be done by
clicking Monitor at the left side of the window and clicking Add Spec at the bottom of
the window. Click Column Component Flow and fill in the condition for the D stream.
Close the window. Repeat this for the B stream.
9. After adding the two new specifications, the list of active specifications must be updated.
This is carried out in the Monitor page, where the two original specifications are
deactivated and the two new specifications are activated.