IP (Ingress Protection) Code Symbols: 1st Digit Protection From Solid Objects 2nd Digit Protection From Moisture

The document illustrates the IP classification system used to indicate levels of protection from solid objects and moisture. The first digit refers to protection from solid objects with symbols representing levels 5 and 6, while the second digit refers to moisture protection with teardrop symbols representing levels 3 through 8. These IP codes and symbols can be placed on equipment to show the degree of protection it provides.

Uploaded by

Amit Makwana
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views

IP (Ingress Protection) Code Symbols: 1st Digit Protection From Solid Objects 2nd Digit Protection From Moisture

The document illustrates the IP classification system used to indicate levels of protection from solid objects and moisture. The first digit refers to protection from solid objects with symbols representing levels 5 and 6, while the second digit refers to moisture protection with teardrop symbols representing levels 3 through 8. These IP codes and symbols can be placed on equipment to show the degree of protection it provides.

Uploaded by

Amit Makwana
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

IP (Ingress Protection)

Code Symbols

The chart below illustrates the use of special symbols in the IP classification system. In the "1st digit" columns, note the grid-like symbols
next to numbers 5 and 6. In the "2nd digit" columns numbers 3–8 are symbolized by teardrop shaped symbols, sometimes enclosed in a
box or a triangle, sometimes unenclosed (7–8). These symbols can be placed on equipment to illustrate the IP protection provided.

1st Digit Protection from solid objects 2nd Digit Protection from moisture

0 Non protected 0 Non protected

1 1

Protected against solid objects greater Protected against vertically


than 50mm dripping water

2 2

Protected against solid objects greater Protected against dripping water when tilted up to 15°
than 12.5mm

3 3

Protected against solid objects greater Protected against spraying water


than 2.5mm

4 4

Protected against solid objects greater Protected against splashing water


than 1.0mm
5 5

Dust protected Protected against jetting water

6 6

Dust tight Protected against powerfully


jetting water

Note: IEC 60529 does not specify sealing effectiveness


against the following: mechanical damage of the equipment;
the risk of explosions; certain types of moisture conditions,
e.g., those that are produced by condensation; corrosive
vapors; fungus; vermin.