Standard Specifications AND Code of Practice FOR Road Bridges
Standard Specifications AND Code of Practice FOR Road Bridges
Standard Specifications AND Code of Practice FOR Road Bridges
<<
IRC: 21-2000
Published by THE INDiAN ROADS CONGRESS Jamnagar House, Shahjahan Road, New Deihi-liflOll 2000 Price Rs. /60/(Plus packing & postage)
<<
IRC: 21-2000
October, 1966 January, 1969 March, 1972 July, 1974 April, 1977 June, 1980 March, 1983 (Incorporates Amendment No. 1-Nov.1971) (Incorporates Amendments No,2-Dec,1972, No,3-Nov,1973 and No.4-April, 1974) (Incorporates Amendment No.5-April, 1976) (Incorporates Amendment No.6-May, 1977) (Incorporates Amendments No.7-September 1981 and No.8-December 1982, modification of Clause No. 303.5, changes in Notations and units as per IRC:71)
March, 1987 August, 1988 September, 1994 (Incorporates Amendment to Clause 304,7.1,1 Errata and Amendment Nos, I to Second Revision) November, 1996 December, 1997 October, 2000
<<
Printed at Dee Kay Printers, New Delhi-I 10015 1000 Copies - October, 2000
IRC: 21-2000
Page No.
Composition of Bridge Specifications & Standards Committee Notations Clause No. Introduction 300 301 302 303 304 305 306 307 308 309 310 Scope Terminology Materials Basic Permissible Stresses General Design Requirements Beams and Slabs Columns and Compression Members Footing or Bases Balanced Cantilever and Continuous Construction Box Girders Workmanship Appendix I Design Surface Crack Width 1 2 3 4 18 20 43 58
65
69 70 71 79
<<
IRC 21-2000
Prafulla Kumar*
(Convenor)
3.
4.
5.
6. 7.
8.
9.
DG(RD) & AddI. Secretary, Ministry of Surface Transport (Roads Wing), Transport Bhawan, New Delhi-I 10001 The ChiefEngineer(B) (V. Velayutham), Ministry of Surface Transport S&R (Member-Secretary) (Roads Wingh), Transport Rhawan, New Delhi-i 10001 S.S. Chakraborty Managing Director, Consulting Engg. Services (1) Ltd., 57, Nehru Place, New Delhi-I 10019 Dr. MG. Tamhankar Emeritus Scientist, Structural Engg. Res. Centre, 399, Pocket E, Mayur Vihar Phase 11, Delhi-I 10091 Ninan Koshi DG(RD) & Add!. Secretary (ReId.), 56, Nalanda Apartments, Vikaspuri, New Delhi AG. Borkar Technical Adviser to Metropolitan Commr., A-I, Susriehi Plot No. 22, Arun Kumar Vaidya Nagar, Bandra Reclamation, Mumbai-400050 N.K. Sinha Chief Engieer (PLC), Ministry of Surface Transport (Roads Wing), Transport Bhawan, New Delhi- 110001 M.V.B. Rao Head, Bridge Division, Central Road Research institute, P.O. CRRJ, New Delhi-I 10020 CR. Alimchandani Chairman & Managing Director (STUP Consultants Ltd., 1004-5, Raheja Chambers, 213, Nariman Point, Mumbai-
Vijay Kumar
M.K. Mukherjee MaheshTandon Dr. TN. Subba Rao AK. Hant AD. Narain V.R.Jayadas
15. C.V.Kand
<<
IRC: 21-2000
23. 24.
P.K.Sarmah
S.R.Tambe
25. 26.
27. 28. 29.
30.
3!. 32. 33. 34. 35. 36.
Guwahati-781003 Secretary, Maharashtra PWD (RaId.), 72, Pranit I. Palkar Marg, Opp. Podar Hospital, Work, Mumbai-400025 (H.P. Jamdar) R.&B Department, Block No. 14, The Secretary to the Govt. of Gujarat New Sachivalaya, 2nd Floor, Gandhinagar-382010 (D. Sree Rams Murthy), National Highways, Irrum Manril, The Chief Engineer (R&B) Hydetabad-500482 The Chief Engineer(NH) (D. Guha), Public Works Department, Writera Building, Block C, Calcutta-700001 (R.R. Sheoran), Haryana P.W.D., B&R, Sector-19 B, The Engineer-in-Chief Chandigarh-160019 Central Public Works Department, Nirman Shawan, New Delhi The Director General (Works) The Chief Engineer Ministry ofSurface Transport (Roads Wing), New Delhi The Chief Engineer (R) (CC. Bhattacharya), Ministry of Surface Transport (Roads Wing), Transport Shawan, New Delhi S&R Highways Research Station, 76 Sarthat Pate! Road, The Director Chennai-600025. Bureau of Indian Standards, Manak Bhawan, 9, Bahadurshah The Director & Head Zafar Marg, New Delhi-i 10002 The Chief Engineer (NH) M.P. Public Works Department, Bhopal-461004 The Chief Engineer (NH) LIP. P,W.D., Lucknow The Chief Engineer (NH) Punjab PWD, B&R Branch, Patiala
Ex-Officlo Members
37. President Indian Roads Congress Director General (Road Development)
38.
39.
K.8. Rajoria Engineer-in-Chief, Delhi, PWD, New Delhi Prafulla Kumar, DG(RD) & Addi. Secretary to the Govt. of India, Ministry of Surface Transport (Roads Wing), Transport Bhawan, New Delhi-i 10001 S.C. Shaima, ChiefEngineer Ministry of Surface Transport (Roads Wing) Transport Bhawan, New Delhi-I 10001
Corresponding Members
I.
2.
NV. Merani
Dr.G.P.Saha
3.
Shitala Sharan
<<
Principal Secretary (Retd.), A-4711344, Adarsh Nagar, Worli, Mumbai.400083 ChiefEngineer, Hindustan Construction Co. Ltd., Hincon House, Lal Babadur Shastri Marg, Vikhroli (W), Mumbai-400083 Advisor Consultant, Consulting Engg. Services (I) P~rt.Ltd., 57, Nehru Place, New Dethi-l 10019
(ii)
IRC 21-2000
NOTATIONS
Es Ec lo n
= = = = = = = =
4)
As
V
= = = =
la R h
a
= =
b V d
13
= = =
modulus of Elasticity of steel modulus of Elasticity of concrete Basic anchorage length Factor for basic anchorage length diameter of reinforcing bars Design anchorage length factor for reduction in anchorage length Factor for reduction in anchorage length for excess reinforcement area of bars actually provided area of bars required at full permissible stress Shift of curtailment line Shift of curtailment line at end supports Lap length Support reaction Depth of Section axial spacing of the bar for calculating the lap length (ci. 304.6.6.3) or the distance of centre of gravity of the concentrated load from the nearer support (ci. 305.16.2) edge distane of bar for calculation of lap length (cl. 304.6.6.3) or the breadth of the rectangular beam or slab or the breadth of the rib in case of flanged beam (ci. 304.7.1.1.1) the design shear across the section effective depth of the section, beam or slab The angle between the top and bottom edges of the beam or slab of varying depth at the section considered for shear (ci. 304.7.1.1.2) or coefficient for reduction in maximum permissible stresses in long column (ci. 306.4.3) or Ratio of the long side to the short side of the footing (cI.
P
Ag
t
=
= = =
Maximum permissible Shear Stress total cross-sectional area of stirrup legs or bent up bars within a distances
<<
(iii)
IRC: 21-2000 s = spacing of the stirrups or bent-up bars along the length of the member = permissible tensile stress in shear reinforcement a = angle between the inclined stirrup or bent up bar and the axis of the member, not less than or (cl.307.l.4) or constant for calculation of effective width (cl.305. 16.2) or modular ratio (ci. 306.5.2) Ve equivalent shear T = torsional moment M = bending moment at the cross-section = equivalent Bending Moment due to torsion D = the overall depth of the beam = cross-sectional area of bar forming the closed hoop = centre to centre distance between corner bars in the direction of the width d, = centre to cet~tredistance between corner bars in the direction of the depth = equivalent shear stress = shear strength of the concrete 1~ = effective span (ci. 305.4) or the unsupported length of the compression flange (cl.305.9), or the distance between points of zero moments (Cl. 305.15.2) / = distance between centre ofsupports Clause 305.15.2 or effective length of column (cl. 306.4.3) 1~ = clear span d = effective depth of beam or slab b = effective width for compression flange = thickness of the web for beams (for T-beam and slab) or thickness of the webs + width of the slab between webs (for hollow box sections)
450
b1
= =
c.ro
= =
the effective width of slab on which the load acts the breadth of concentration area of the load for calculation of effective width the permissible stress in direct compression for concrete the permissible stress in direct compression for the longitudinal steel the cross-sectional area of concrete exclusive of any finishing material applied after the casting of the column
<<
IRC: 21-2000
A,
=
Ao
= =
r
N W
up,
= = =
cal
o~,cal AL
= =
=
the cross-sectional area of the longitudinal steel in columns or area of the tension reinforcement the cross-sectional area of concrete in the column core, excluding the area of longitudinal steel the equivalent area of helical reinforcement Tension in helical reinforcement the least radius of gyration the permissible axial load on the column the section modulus the calculated direct compressive stress the calculated compressive bending stress the permissible flexural compressive stress dispersed concentric area which is geometrically similar to the loaded area loaded area is the minimum cover to the tension steel is the perpendicular distance from the point considered to the surface of the nearest longitudinal bar is the average strain at the level where cracking is being considered calculated allowing for the stiffening effect of the concrete in the tension zone is the width of the section at the centroid of the tension steel is the distance from the compression face to the point at which the crack width is being calculated is the average strain at the level where cracking is being considered, calculated ignoring the stiffening effect of the concrete in the tension zone is the depth of the neutral axis found from the analysis to determine e, 2 characteristics strength of untentioned steel in N/mm
A2
c
= =
= =
a
C
<<
(v)
IRC: 21-2000
The Standard Specifications and Code of Practice for Road Bridges, Section III Cement Concrete (Plain and Reinforced) was first published in October, 1966. To cater for thetechnological developments which were taking place in course of time, the Code was exaniinel by the Technical Committees of the IRC and revised in 1972 and in 1987 in the light of their recommendations.
-
In the light of further developments in the field of plain and reinforced concrete, the provisions of the Code were reviewed by the Committee for Reinforced, Prestressed and Composite Concrete (13-6) consisting of the following personnel:
Ninan Koshi A.N. Dhodapkar Convenor Member-Secretary MEMBERS N.K. Sinha Jose Kurien S.G. Joglekar P.Y. Manjure Dr. T.N. Subba Ran A.S.PrasadaRao M.K. Mukhexjee itA. Chaudhary Dr. M.G. Tainhankar G.R. Haridas Shitala Sharan D.D. Sharma Mahesh Tandon Director & Head, Civil Engg., S.A. Reddi Bureau of Indian Standard, Ashok K. Basa (Vinod Kumar) T. Viswanathan EX-OFFICIO MEMBERS President, IRC DG(RD) (K.B. Rajoria) (Prafulla Kumar) Secretary, IRC
(S.C. Sharma)
<<
IRC: 21-2000
The amendments as finalised by this Committee were considered and approved by the Bridge Specifications and Standards Committee in their meeting held at New Delhi on 7th December, 1999 and later approved by the Executive Committee in their meeting held at New Delhi on 14th December, 1999. The, draft amendments were discussed and approved by the Council of the Indian Roads Congress at the 157th Council Meeting held at Madurai on 4th Jahuary, 2000. It was also decided that the document would be published as a fully revised Code after incorporating all the amendments. The object of issuing the Standard Specifications and Code of Practice for Road Bridges Section 111-Cement Concrete (Plain and Reinforced) is to establish a common procedure for the design and construction of road bridges in India. The publication is meant to serve as a guide to both the design engineers and the construction engineers but compliance with the provisions therein does not relieve them in any way of the responsibility for the stability, soundness and safety ofthe structures designed and erected by them. The design and construction of road bridges require an extensive and thorough knowledge of science and technique involved and should be entrusted only to specially qualified engineers with adequate experience of bridge engineering, capable, of ensuring careful execution of work.
300. SCOPE This Code deals with the structural use of plain cement concrete and reinforced cement concrete in road bridges.
<<
IRC: 21-2000
301. TERMINOLOGY
For the purpose of this Code, the following definitions shall apply: 301.1. Concrete
A mixture of cement, water, fine and coarse aggregates and any admixture (that may be permitted by the competent
authority) prepared and placed in accordance with this Code. 301.1.1. Reinforced concrete : Concrete containing steel reinforcement (non-prestressed) conforming to Clause 302.5 of this Code and of no less than the minimum amount required by this Code and is a composite material in which both materials act in co-operation to resist the stress resultants. (Concrete containing prestressed steel reinforcement for introducing precompression oftensile flange ofelement is termed Prestressed Concrete which is outside the purview of this Code). 301.1.2. Plain concrete : Concrete containing no steel reinforcement or less amount of reinforcement than specified for reinforced concrete in this Code, the co-operation of such steel being ignored in resisting stress resultants. (Plain concrete cast in such massive dimensions as to require specific measures to be taken to cater for generation of heat and attendant volume change to minimise cracking is termed Mpss Co9crete which is outside the purview of this Code). 301.2. Core of Helically Reinforced Column The portion of the concrete enclosed within the outer surface formed by the helical reinforcement. 301.3. Curing Concrete : Maintaining moisture condition to promote continued hydration of cement in the concrete. <<
1RC: 21-2000
301.4. EffectIve Depth of a Beam : The distance between the centroid of the area of tension reinforcement and the fibre at which the compressive stress is maximum.
301.5. Mortar : A mixture of cement, fine aggregate and water and any admixture that may be permitted by the competent authority. 301.6. Cover : The thickness from the outer surface of the concrete to the nearest surface of the reinforcement.
302. MATERIALS
302.1.
Cement
Any of the following types of cement may be used with prior approval of competent authority.
Table 1
{i) (ii) (iii) (iv) (v) (vi)
(vii)
Type Ordinary Portland Cement 33 Grade Ordinary Portland Cement 43 Grade Ordinary Portland Cement 53 Grade Rapid Hardening Portland Cement Sulphate Resistant Portland Cement
Portland Pozzolana
C onformlag to
IS: 269
IS: 8112 IS: 12269 IS: 8041 IS: 12330
Cement
IS: 1489-Part-I
Portland Blast Furnace Slag Cement IS: 455 (viii) Low Heat Portland Cement IS: 12600 Notes : (1) Use of Portland pozzolana cement may be permitted only in
special literature on precautions to be taken with regard to the use of special types of cement with low C 3A content may be
referr&~to.Durability criteria like minimum cement content
and water cement ratio, etc. should also be given due consideration.
<<
IRC: 21-2000
302.2.
Admlxtures
302.3.
302.3.1.
Aggregates
General : All coarse and fine aggregates shall conform to IS:383 and shall be tested to conform to IS:2386
Parts I to VIII. 302.3.2.
Coarse aggregate
302.3.2.1. Coarse aggregates shall consist of clean, hard, strong, dense, non-porous and durable pieces of crushed stone, crushed gravel, natural gravel or a suitable combination thereof or other approved inert material. 302.3.2.2. The maximum size of the coarse aggregate may be as large as possible within the limits specified, but in no case greater than one quarter of the minimum thickness of member or 10 mm less than the minimum lateral clear distance between individual reinforcements or 10 mm less than the minimum clear cover to any reinforcement. 302.3.2.3. The preferred nominal size of aggregate is 20 mm for reinforced concrete and prestressed concrete. However, larger sizes upto 40 mm may be permitted in special cases when there is no restriction to flow of concrete in a section. For plain concrete, preferred nominal sizes may be between 20 mm and 40 mm. However, larger si~esmay be permitted only in special cases, subject to supplemen~taI specifications and precautions. 302.3.3. Fine aggregates : Fine aggregates shall consist of hard, strong, durable clean particles of natural sand, crushed <<
IRC: 2 1-2000
stone or gravel or suitable combination of natural sand and crushed stone or gravel. They shall not contain dust, lumps, soft or flaky particles, mica and other deleterious materials in such quantities as would reduce the strength or durability of concrete or attack the reinforcement. 302.3.4. Grading of aggregates shall be such as to produce a dense concrete of the specified strength, which can be worked readily into position without segregation and without the use of excessive water content. 302.4.
Water
Water used for mixing and curing shall be clean and free from injurious amounts of oils, acids, alkalis, salts, sugar, organic materials or other substances that may be deleterious to
concrete or steel.
302.4.1. In case of doubt regarding development of strength, the suitability of water for making concrete shall be ascertained by the compressive strength and initial setting time tests specified in 302.4.1.2. and 302.4.1.3. 302.4.1.1. The sample of water taken for testing shall represent the water proposed to be used for concreting, due account being paid to seasonal variation. The sample shall not receive any treatment before testing other than that envisaged in the regular supply of water proposed for use in concrete. The sample shall be stored in a clean container previously rinsed out with similar water. 302.4.1.2, Average 28 days compressive strength of at least three 150 mm concrete cubes prepared with water proposed to be used shall not be less than 90 per cent of the average of strength of three similar concrete cubes prepared with distilled water. The cubes shall be prepared, cured and << 6
IRC: 2 1-2000 tested in accordance with the requirements of IS:516. 302.4.1.3. The initial setting time of test block made with
the appropriate cement and the water proposed to be used shall
not be less than 30 minutes and shall not be more than 30 minutes from the initial setting time of control test block prepared with the same cement and distilled water. The test blocks shall be prepared and tested in accordance with the requirements of IS:403l (Part 5).
The pH value of water shall not be less than 6. Potable water is generally considered satisfactory for mixing
302.4.2.
concrete. As a guide the following concentrations represent the maximum permissible values
(a) To neutralise 100 ml sample of water, using phenolphthalein as an indicator, it should not require more than 5 ml of 0.02 normal NaOH. The details of test are given in 8.1 of IS:3025 (Part 22). (b) To neturalise 100 ml sample of water, using mixed indicator, it should not require more than 25 ml of 0M2 normal H2S04. The details of test shall be as given in Clause 8 ofIS:3025 (Part 23).
Permissible limits for solids shall be as given in Table 2.
(c)
Organic
Inorganic Sulphates (as SO3) Cholorides (as Cl) ~
400 mg/lit.
2000 mg/lit. for concrete work not containing embedded steel and 500 mg/lit, for prestressedlreinforced concrete work 2000 mg/lit.
Suspended matter
<<
IRC 21-2000
Mixing or curing of concrete with sea water is not permitted because of presence of harmful salts in sea water. 302.4.4. Water found satisfactory for mixing is also suitable for curing concrete. However, water used for curing should not produce any objectionable stain or unsightly deposit on the concrete surface. The presence of tannic acid or iron
compounds is objectionable.
302.4.3.
302.5.
Reinforcement
Reinforcement shall consist of the following grades of reinforcing bars, designated by their characteristic strength, where characteristic strengthf~ shall be taken as that specified in governing IS Specifications listed in Table 3 as the minimum
value of 0.2 per cent proof stress or yield stress. Table 3
Grade Bar type conforming Characteristic strength f MPa designation to governing IS Elastic modulus
GPa
Fe 240
Fe 415
240
415
200
200
Fe 500
IS:l786 Deformed
bar
500
<<
IRC : 21-2000
302.6.
Concrete
302.6.1. Concrete grade : The concrete shall be in grades designated in Table 4, where the characteristic strength is defined as the strength of material below which not more than 5 per cent of test results are expected to fall
Table 4 Grade designation Specified characteristic compressive strength of 150 mm cubes at 28 days (MPa)
M 15
M M M M 20 25 30 35
15
20
25 30
35
M 40 M 45 M 50
M 55
40
45
50
55
302.6.2. Minimum concrete grade, minimum cement content and maximum water cement ratio for structural~membersunder different conditions of exposure are given in Table 5. 302.6.3. The cement content shall not exceed 540 kg/rn3 of concrete. 302.6.4. Total water soluble sulphate (SO 3) content of the concrete mix expressed as (SO3) shall not exceed 4 per cent by mass of cement used in the mix. 302.6.5. Total chloride content in concrete expressed as chloride-ion shall not exceed the following values by mass of
<<
IRC : 21-2000 z
1-
9
.~ ,~
9
Z~ ~
~c
~ ~ -~
LC,
~ ~
.~J
Cfl ~ O~)
C
~ ~
o
~
~U~LZ
~
LU
.,-
z
_~
.L~ U ~ .~
~o
C
~
E~.
0
)<~
Z
~
c,~ ~
z
..~ ,~
~
t~
~.
I-
~2
~ ~
LZ~ >
o~
l,~._ I.~~
I-J ~
LZ~
~<&~~o
C)
~ ~
Z~.
~<
c~:;:
-~
~p
C)
~
0
Ib-.
~ ~-
~
L~3
-.>
L~J
c.
.
C ~
0u..
u_o
~
u2rn
..
z
~
LU
~ C
C,
LU
10
<<
C)
IRC : 2 1-2000
cement used
Type
PSC R.C.C. (in severe condition of exposure) R.C.C. (in moderate condition of exposure) and P.C.C.
302.7.
302.7.1. Target mean strength : The target mean strength of specimen shall exceed the ~specified characteristic
shall be taken as 1.64 times the standard deviation of sample test results taken from at least 40 separate batches of concrete of nominally similar proportions produced at site by the same plant under similar supervision, over a period exceeding 5 days, but not exceeding 6 months. (ii) Where there are insufficient data to satisfy the above, the current margin for the initial mix design shall be taken as given in Table 6. Table 6 Concrete Grade M 15 M 20 M 25 M 30 M 35 M 40 M 45 M 50 M 55 M 60 Current Margin (MPa) 10 10 11 12 12 12 13 13 14 14 Target Mean Strength (MPa) 25 30 36 42 47 52 58 63 69 74
<<
IRC: 21-2000
(c)
(ii) (iii)
full details of tests on trial mixes carried out in accordance with sub-clause 302.7.3 or for ordinary structural concrete, a statement that, for initial production, the appropriate mix proportions given in Table 7 will be used.
Proportion of
Table 7. Proportions for Nominal Mix Concrete Concrete Total quantity of dry Grade aggregate by mass per 50 kg of cement to be taken as the sum of individual masses of fine and coarse aggregate (Kg) MiS 350
fine aggregate
to coarse aggregate (by mass) Generally 1:2, subject to upper
limit
P.C.C. R.C.C. 25
-
1:1.5
<<
M20
IRC : 21-2000
302.7.3. Trial mixes : Trial mixes shall be prepared using samples of approved materials for all grades of concrete. Sampling and testing procedures shall be in accordance with Clauses 302.10 and 302.11. The concreting plant and means of transportation employed to make the trial mixes and to transport them to representative distances shall be similar to the corresponding plant and transport to be used in the works. A clean dry mixer shall be used and the first batches shall be discarded. Test cubes shall be taken for trial mixes as follows. For each mix, set of six cubes shall be made from each of three consecutive batches. Three from each set of six shall be tested at an age of 28 days and three at an earlier age approved by the engineer-in-charge. The cubes shall be made, cured, stored, transported and tested in compression in accordance with the specification. The average strength of the nine cubes at 28 days shall exceed the specified characteristic strength by the current margin minus 3.5 MPa.
Additional trial mixes : Additional trial mixes and tests, shall be carried out during production before substantial 302.7.4.
changes are made in the material or in the proportions of the materials to be used, except when adjustments to the mix proportions are carried out in accordance with 302.9.2.1. 302.8.. RequIrement for Nominal Mix Concrete
302.9.1. Batching and mixing : The quantities of << fine aggregate and the various sizes of coarse aggregate cement,
IRC : 21-2000
shall be measured by weight, unless otherwise authorised by the engineer-in-charge. A separate weighing machine shall be provided for weighing the cement. Different types of cement shall not be mixed. The quantity of water shall be measured. Any admixture to be added shall be measured and, if solid, shall be measured by weight. The batch weight of aggregate shall be adjusted to allow for moisture content typical of the aggregate being used. All measuring equipment shall be maintained in a clean and serviceable condition. Its accuracy shall be checked over the range in use when set up at each site, and maintained thereafter. The accuracy of equipment shall fall within the following limits
Measurement of cement Measurement of water
3 per cent of the quantity of cement in each batch 3 per cent of the quantity of water in
each batch
in each batch
The concrete mixer shall comply with the requirement of BIS where applicable. The mixing time shall be not less than that recommended by the manufacturer, subject to the approval of the trial mixes by the engineer-in-charge. Concrete mixers that have been out of use for more than 30 minutes shall be thoroughly cleaned before any fresh <<
14
IRC : 2 1-2000 concrete is mixed. Unless otherwise agreed the first batch of concrete through the mixer shall then contain only two-thirds of the normal quantity of coarse aggregate. Mixing plant shall be thoroughly cleaned before changing from one type of cement to
another.
302,9.2.
to mix proportions may be made in order to minimise the variability of strength subject to approval of engineer-in-charge and to maintain the target mean strength subject to approval of engineer-in-charge. Such adjustments shall not be taken to imply any change in the current margin. 302.9.2.2. Change of current margin When required by the engineer-in-charge, the current margin shall be recalculated in accordance with Clause 302.7.1. The recalculated value shall be adopted as directed by the engineer-in-charge, and it shall become the current margin of concrete produced subsequently. 302.10. Sampling and Testing
302.10.1. General: Samples from fresh concrete shall be taken as per iS: 1199 and cubes shall be made, cured and tested at 28 days in accordance with IS:516. 302.10.2. Sampling procedure A random sampling procedure shall be adopted to ensure that each concrete batch shall have a reasonable chance of being tested, that is, the sampling should be spread over the entire period of concreting and cover all mixing units. The point and time of sampling shall be at delivery into the construction, unless otherwise agreed to. 302.10.3. Frequency: The minimum frequency of sampling of concrete of each grade shall be in accordance with Table 8. <<
!RC: 2 1-2000
Table 8
Quantity of Concrete in Work (m3)
1-5 Number of Samples 1 2 3 4 4 plus one additional sample for each additionai 50 m3 or part thereof
6-15
16-30 31-50 51 and above
At least one sample shall be taken from each shift of work. 302.10.4. Test specimen and sample strength : Three test specimens shall be made from each sample for testing at 28 days. Additional cubes may be required for various purposes such as to determine the strength of concrete at 7 days for any other purpose. The test strength of the sample shall be the average of the strength of three specimens. The individual variation should not be more than 15 per cent of the average. 302.11. Acceptance Criteria
302.11.1. Compressive strength : When both the following conditions are met, the concrete complies with the specified compressive strength:
(a) The mean strength determined from any group of four consecutive samples should exceed the specified characteristic compressive strength by 3 MPa. compressive strength minus
(b)
Strength of any sample is not less than the specified characteristic 3 MPa.
302.11.2. Workability : The concrete mix proportions << chosen should be such that the concrete is of adequate
IRC : 21-2000 workability for placing condition of the concrete to ensure proper compaction. Suggested ranges of workability of concrete measured in accordance with IS:1195 are given below Degree of WorkabiLity
Low
Medium
Slump (mm)
25-50 50-100
High
100-150
302.11.3. Chloride content : Unless otherwise specified and agreed, the method of calculation and test shall be based upon the chloride-ion contents of all constituents and the composition of the concrete. The chloride-ion content of each of the constituent used in the calculation shall be one of the following:
(a) (b) the measured value the value declared by the manufacturer
the maximum value where specified in the BIS for the constituent as appropriate. The calculated chloride content of the concrete expressed as the percentage of chloride-ion by mass of cement shall not exceed the value specified in Clause 302.6.5. 302.11.4. Density of fresh concrete : Where minimum density of fresh concrete is specified, the mean of any four consecutive samples shall not be less than the specified value and any individual sample result shall not be less than 97.5 per cent of the specified value. 302.11.5. Density of hardened concrete : Where minimum density of hardened concrete is specified, the mean of any four << consecutive samples shall not less than the specified value and
(c)
IRC : 2 1-2000
individual sample result shall not be less than 97.5 per cent of the specified value.
any
302 12 Storage of Materials All efforts shall be made to store the materials in proper places so as to prevent their deterioration or intrUsion by foreign matter and to ensure their satisfactory quality and fitness for the work. The storage space shall also permit easy inspection, removal and re-storage of the materials. All such materials, even though stored in approved storage, shall be subjected to acceptance test prior to their use. 303. BASIC PERMISSIBLE STRESSES 303.1. The permissible stresses for concrete of different grades shall be as indicated in Table 9.
TabLe 9. Properties and Basic Permissible Stresses of Concrete
Concrete grade
Properties/permissible stresses 1. Modulus of elasticity Ec~design value (GPa) 2. Permissible direct
MMMMMMM
15 20 25 30 35 40 45
M 50 35
M 55 36
M 60 37
32.5 33.5
compressive stresses
(MPa)
~,
allowable
3.75
3. Permissible flexural
<<
303.2. 303.2.1.
steel reinforcement
Fe 415 Fe 500
combined bending
200 240
Fe 240 Fe 415
Fe 500
Direct compression
.
115 170
205
Fe 240 Fe 415
Fe 500
95
95
95
303.3.
concrete
Concrete grade
Permissible tensile stresses MPa
M 20
0.53
M 25
0.61
M 30 and above
0.67
In case of concrete members cast in one lift with no construction joints or when special precautions are taken for surface preparation of joints like use of wet sand blasting or surface retarders, the basic values given in Table 11 can be permitted to be increased but in no case shall these exceed 1.25 times the basic value given in Table 11.
<<
19
IRC: 21-2000
303.4.
303.4.1. The requirement of crack control at the tensile face of reinforced concrete components under sustained loads shall be deemed to have been satisfied, provided the following detailing criteria are met
(i) (ii)
For slabs, the diameter and spacing of reinforcing bar shall not exceed 25 mm and 150 mm respectively.
For beams, including top and bottom flanges in rectangular
voided slab and box beams and for solid slabs in solid slab balanced cantilever bridges the diameter and spacing of
reinforcing bar shall not exceed 32 mm and 150 mm respectively. (iii)
For columns the diameter and spacing of reinforcing bar shall not exceed 32 mm and 300 mm respectively.
303.4.2. In special cases, where the detailing criteria stated in Clause 303.4.1 are not possible to be achieved, the~ designs shall be checked for crack width limitations as specified in Appendix- I. 303.5. PermIssible Stresses under various Combinations of Loads and Forces
303.5.1. The permissible stresses given in Clause 303 shall not be exceeded for combination I of Clause 202.3 of IRC:6. The permissible increase for other combinations shall conform to Clause 203 of IRC:6. 304. GENERAL DESIGN REQUIREMENTS 304.1. General 304.1.1. Various stresses that are likely to occur in any plain and reinforced concrete structure, under the worst combination of loads and forces, specified in IRC:6 shall be provided for in accordance with accepted design and construction
<<
20
mechanics without exceeding the limits of stresses specified in Clause 303. 304.1.2. The detailing of reinforcement in all components shall be such as to ensure satisfactory placement and good compaction of concrete all around in the components with due consideration being given to the construction techniques adopted. 304.2. Basis of Design
304.2.1. The strength of a reinforced concrete structural member may be assessed by commonly employed elastic theory and it may be assumed that (i) the modulus of elasticity of steel is 200 GP~ unless otherwise determined by tests. (ii)
(iii)
the modular ratio has the values given in Table 9 (note 1) and
unless otherwise permitted, the tensile strength of concrete is
ignored.
304.2.2. In plain concrete structures, tension upto limits specified in Table 11 may be permitted. 304.3. Cover
304.3.1. The minimum clear cover to any reinforcement bar, closest to the concrete surface, shall be 40 mm. 304.3.2. Increased minimum cover thickness of 50 mm shall bc proyided when concrete members are exposed to severe conditions of exposure as mentioned in note (1) of Table 5 except that for the condition of alternate wetting and ~dryingand in cape of foundations where the minimum clear cover shall be
75 mm.
304.3.3.
<<
IRC 21-2000
304.4.
Bar Sizes
304.4.1. The maximum size of reinforcement shall be 40 mm diameter or a section of equivalent area, unless a bigger size is permitted by the competent authority. 304.4,2. The diameter of any reinforcing bar, including
transverse ties, helicals, stirrups and all secondary reinforcement, shall generally be nOt less than 8 mm.
304.4.3.
columns shall not be less than 12 mm. 30444. The diameter of reinforcement in slabs shall be limited to one-tenth the depth of slab; and the diameter of shear reinforcement in beam-webs, including cranked bars, if any,
shall be limited to one-eighth the thickness of the web.
304.5. 304.5.1.
reinforcing bars shall not be less than the greatest of the following three dimensions (i) (ii)
(iii) Note :
10 mm more than the nominal size of the coarse aggregate used in concrete.
In order to comply with the provisions of this sub-clause, the size of the coarse aggregate for the concrete around congested reinforcement may be reduced. This does not preclude the use of large size aggregate where the reinforcement is not congested.
<<
22
IRC: 21-2000
304.5.2. Sufficient space shall be left between groups of bars to enable the vibrator to be inserted. 304.5.3. The minimum vertical distance between two horizontal main reinforcing bars shall be 12 mm or the maximum diameter of the coarse aggregate or the maximum size of the bar, whichever is greater. 304.5.4. When contact of bars along the lap length cannot be avoided, such bars shall preferably be grouped in the vertical plane. In no case, however, shall there be more than three bars in contact. The vertical and horizontal distances specified in the Clauses 304.5.1, 304.5.2 and 304.5.3 shall be maintained between any such group and an adjacent group or bar. 304.5.5. Subject to satisfying crack control criteria as given in Clause 303.4 the pitch of bars or wires of main tensile reinforcement in slabs shall not exceed 300 mm or twice the effective depth of the slab whichever is smaller. 304.5.6. All mesh reinforcement shall be of such dimensions as will enable the coarsest material in the concrete to pass easily through the meshes of such reinforcement. 304.6. Bond, Anchorage, Splice
304.6.1. To prevent bond failure, design tension or compression in any reinforcing bar at any section of an element shall be developed on each side of the section by an appropriate anchorage length conforming to provisions given in Clause 304.6.2 or by a special anchoring device or by a combination of both. Provided this is done, local bond stresses may be ignored.
<<
23
Anchorage length
304.6.2.1. lermlssible basic value-b The length required for developing full strength of bar with straight ends in tension at anchorage to keep the average bond stresses within allowable limits is termed as the basic permissible value of anchorage length lo = n
The values of n are given in Table 12 varying with
grade of reinforcement grade of concrete and bonding zone
n =_lo/4) M 30 M 35
M 40 and above 42
66 55 65
56 46 60
48
42
40
55
35
50
35
50
Bonding zone II (unfavourable) shall apply to horizontal or barbent less than 450 and so located that more than 300 mm of fresh concrete is cast below the bar, Fig. 1. Bonding zone I (favourable) shall apply to bar not located in bonding zone II. 304.6.2.2. Design value
(1)
d
Bars in tension shall be developed either by a design anchorage length with straight ends or with end hooks of the shape 24
<<
IRC: 21-2000
____
Ii
o~icro.~ co~c~~n~a oc 4
_____
I
DIRICTION CONCREflNO
~OOj-~.
1~300mm
BAR
IN nONDING ZONI
UNFAVOURABLE
Fig. 1. Bonding zones specified in Fig. 2. For bars of grade Fe 240 anchorage with straight ends is not permitted.
(2) Bars developing for full tensile strength shall have design
anchorage length.
=
Ia)
(1,10
aI
I for bars with straight ends 0.7* for bars with end hooks
not
*applies when cover in the plane of curvature and transverse to it is less than 34). With less cover, a~= I applies. (3) At sections where reinforcement area in excess of design requirement (A, A,d) has been provided a reduced length
-
td = ~c2 =
AJAs withcc>l/3 s 2
=
AjA
(4)
d
-
id> 1, minimum
<<
IRC
: 2 1-2000
Id
dl > 6
~Io~
r
di 24 BARS WITH END
HOOKS
d2
BENT UP (DOWN)
<<
for bars
ends
1, mm.
=
12
4) or 300 mm
1, mm
4) or 150 mm
Whichever is greater.
Whichever is greater,
304.6.2.3. DesIgn value for bars in compression : Bars in compression shall be developed by an anchorage length with straight ends, end hooks being deemed not effective and value of d shall be same as that specified for bars in tension in Clause 304.6.2.2. 304.6.3. Anchorage offlexural reinforcement in beams and slabs : The provisions of the clause shall illustrate, supplement and modify the general requirements given in Clause 304.6.2. 304.6.3.1. Anchorage of bars over bearings : Anchorage length of bottom bars may be reduced to 2/3 at end or at intermediate simple support to cater for the favourable effects of transverse compression. Anchorage length shall be measured from the inner (span) face of the support, Fig. 3. 7
1.ONSITUO0~KA~~
DIRECT SUPPOWF
LONOIT(~IP4A~. SIAM
INDiRECT SUPPORT
<<
JRC 21-2000
For indirect support full Id shall be provided. 304.6.3.2. Anchorage of bars in tensIon zone : Bars may be curtailed and anchored in the tension zone of a beam or slab when the following conditions are satisfied
(1) (2) The curtailment and anchorage is done according to Fig. 4. Curtailment of bars is optimally staggered and the area of bars curtailed satisfies the limits on continuing bars laid down in Clause 305.7. The ends of curtailed bars are bent up at a very flat angle over the anchorage length to yield a bigger cover as shown in Fig.4.
Id DESIGN ANCHORAGE LENGTH
(3)
[4
V r
011TH Or ~
,,,,,,~j
AT A AT BOll STOP
o 50 1 0
DEThIL
304.6.3.3. Anchorage of bars bent up (down) : Bars not required for shear resistance shall have an anchorage length id measured from the point of bending. Bars required for shear resistance will be continued to the opposite face of the beamlslab and anchored with a length of 0.6 <<
LRC : 21-2000
BENT DOWN OF SHEAR ANCHOREO IN THE ZONE OF TENSILE STRESSES IN THE CONCRETE. BAR USED AS SHEAR REINFORCEMENT 0.6 Id.
BENT UP OF SHEAR . ANCHORED IN THE ZONE Dr COMPRESSNE STRESSES IN THE CONCRETE. (BAR USED AS SHEAR REINFORCEMENT)
L~b. ji~i~cT~f
BAR NOT USED AS SHEAR REINFORCEMENT
Id1 in compression zone and 1,3 Id1 in tension zone parallel to face of the beam, see Fig. 5. 304.6.4. The shear stirrups shall be deemed adequately anchored when the rcquirements illustrated in Fig. 6 are met with.
304.6.5. Special anchoring device : When the ends of a secondary reinforcement, such as stirrups or binders, are anchored in the compression zone; complete anchorage shall be notwithstanding any of the other provisions of this Code, deemed to have been provided when the end is bent round a bar << of at least its own diameter through an angle of at least 900 and
IRC: 21-2000
CLOSING IN
.4
II ~os.iiusmuIt oul~
oil
II
CLOSING WITH
AREA OF THE
T-BEAMS SLAG
IN THE
AND
continued beyond the end of the curve for at least eight times the diameter or alternatively through an angle of at least 1800 and
continued beyond the end of the curve for at least four tines the diameter of the bar. 304.6.6. Splices
(1)
(2)
IRC: 21-2000
H 3 ~
.1
CENTRES
OF SPUCES
Edge distance
Fig. 7. Longitudinal staggering and transverse distance of reinforcing
bars in the region of lap splices (dimensions in mm)
(2)
Area of bars spliced at any section shall not exceed the following proportions p in relation to the total
area of
In exceptional cases, 100 per cent lapping at a section may be pemiitted for deformed bars only, subject to special precautions
and supplemental specifications.
<<
31
1RC : 2 1-2000
p %
K=
25%
>
25% 1,6
50%
1,4
18
2.2
>
Where
= =
axial spacing
of
the bar
(2) the length of lap of bars in compression shall be equal to I~. ooks H shall not be considered effective.
304.6.6.4. Transverse reinforcement at lap splices Minimum reinforcement in the form of stirrups shall he provtded over the length conforming to the requirements shown in Fig. 8.
ri
STiRRUP
1
a J
<<
Fig. 8. Longitudinal section
IRC : 2 1-2000 304.6.6.5. Welded joints may be used subject to the following
(a) Welding of Fe 240 grade bars conforming to IS:432 shall be permitted. Welding of other grades of bars including Fe 500/ 415 grade bars conforming to IS: 1786 shall in general be prohibited except in special cases mentioned in (h) below, Welding shall conform to 15:2751 except as provided herein. Wclding may be carried out by metal arc welding process. Oxyacetylene welding shall not be permissible. Any other process may be used subject to the approval of the engineer and necessary additional requirements to ensure satisfactory joint performance. Precautions on over heating, choice of electrode, selection of correct current in arc welding etc., should he strictly observed. All bars shall be butt welded except for smaller diameter bass with diameter of less than 20 mm which may be lap welded. Single-V or Double-V butt joints may generally be used, For vertical bars single bevel or double bevel butt joints may he
used,
(h)
(c)
(d)
(e) (1)
Welded joints shall be located well away from bends and not less than twice the bar diameter away from a bend, Generally, shop welding in controlled conditions is to be preferred, where feasible, Site welding where necessary shall, however, be permitted when the facilities, equipment, process, consumables, operators, welding procedure are adequate to produce and maintain uniform quality at par with that attainable in shop welding to the satisfaction of the engineer. Joint welding procedures which are to be employed shall invariably be established by a procedure specification and shall be qualified prior to use by tests as prescribed in 15:2751. All welders and welding operators to be employed shall have to be qualified by tests prescribed in IS:2751, Inspection of welds shall conform to IS:822 and destructive or non-destructive testing may be undertaken when deemed necessary .Ioints with
,
(g)
<<
IRC: 21-2000 weld defects detected by visual inspection or dimensional inspection shall not be accepted. (h) As exception to the provision of(a) above, bars of grades other than Fe 240 grade including special welding grade of Fe 500/ 415 grade bars conforming to lS:1786, for which necessary chemical analysis has been secured and the carbon equivalent calculated from the chemical composition using the formula
Mn CE.
=
Cr+Mo+V
+
+
Ni+Cu
15
C +
6
is 0.4, or less, may be permitted to be welded, The method of welding shall conform to supplemental specifications to the satisfaction of the engineer and shall be subject to suitable qualification tests.
304.6.6.6. At the welded joints complying with Clause 304.6.6.5, while 100 per cent of the cross sectional area may be taken into account as effective for Fe 240 grade bars conforming to ES:432, only 80 per cent of such area in respect of bars other than mild steel including Fe 500/415 grade bars conforming to IS:1786 shall be considered as effective. 304,6.6,7. Bars may be joined with mechanical devices e.g. by special grade steel sleeves swaged on to bars in end to end contact or by screwed couplers. The effectiveness of such joints shall invariably be proved by static and fatigue strength tests. Patented system~~s with proven use shall only he permitted to be used on production of test results showing the adequacy of the device to the satisfaction of the competent authority. A mechanical joint including its connecting elements shall develop in tension or compression at least 125 per cent of the characteristic strength j.
<<
34
IRC : 21-2000
304.7. 304.7.1.
3043.1.1. Shear stress 3047.l.l,l. The design shear stress t at any cross section of beams or slabs of uniform depth shall be calculated by the equation
V b~ d
Where
V b
= =
the design shear across the section breadth of the member, which for flanged sections
d
Note :
For obtaining the maximum shear stress, the section at a distance equal to effective depth from the face of the support shall be checked and the shear reinforcement calculated at the section shall be continued up to the support.
304.7,1.1.2. In case of a beams or slabs of varying depth, the equation shall be modified as
V Mtan/3 d
b,d
bending moment at the section, due to load position corresponding to shear V angle between the top and the bottom edges of the beam at that section,
The negative sign in the formula applies when the bending moment M increases numerically in the same direction as the effective depth d increases, and the positive sign when the moment decreases numerically in this direction. <<
35
IRC : 212000
When shear reinforcement is provided the shear not exceed stress tmax~given in Table 12k
t in
beams shall
For slabs, r shall not exceed half the value of t rflLLN given in Table 12k
,
Table 1 2A. Maximum Shear Stress, Concrete Grade M20 M25 M30
max,
t Ut ,
N/mm1
1.8
1.9
2.2
304713.
3047.1.3,1. The peniiissihle shear stress -r~ concrete in in beams without shear reinfocement is given in Table I 2B. 304.7.1.3 For solid slabs the permissible shear in concrete shall be K.-rwhere .Khas the values given in Table 12C.
.
3047133!. Shear strength of members under axial compression : For members subjected to axial compression P, tile permissible shear stress in concrete given in Table I 2B, shall be multiplied by the following factor:
5P d Where
~-
P
=
1ck
but not exceeding 1.5 Af g axial compressive force in Newtons, gross area of the concrete section in mnY, and characteristic compressive strength of concrete
<<
36
ERG : 21-2000 Table 12W Permissible Shear Stress in Concrete 100 A lxi
Permissible Shear Siress in Concrete, t N/mm2 Grade of Concrete M20 M25 M30 M35 M40 (1) (2) (3) ~4) (5) (6) 0.15 0.18 0.19 0.20 0.20 0.20 0.25 0.22 0.23 0.23 0.23 0.23 0,50 0.30 0.31 0.31 0.31 0.32 0... 75 0.35 0.36 0.37 0.37 0.38 1.00 0.39 0.40 0.41 0.42 0.42 1.25 0,42 0.44 0.45 0.45 0.46 1 .50 0.. 45 t).46 0.48 0.49 0.49 1.75 0.47 0.49 0.50 0.52 0.52 2..00 0.49 0.51 0.53 0.54 0.55 2.25 0.51 0.53 0.55 0.56 0.57 2.50 0.51 0.55 0.57 0.58 0.60 2.75 0.51 056 0.58 0.60 0.62 3, on and above 0.5 I 0.57 0.60 0.62 0.63 Nute~, A is that area of longitudinal tension reinforcement which continues at least one effective depth beyond the section being considered except at supports where the full area of tension reinforcement may be used provided the detailing conforms to Clause 304.6.
..
Table 12G. Values of K for Solid Slabs 300 or 275 more 1,00 1.05 250 225 200 175 150 or less 1.30
1.10
1.15
1.20
1.25
304.7. I .4. Members with shear reinforcement : When r exceeds r~given in Table 1213, shear reinforcement shall he provided in any of th.e thRowing forms
<<
37
IRC: 21-2000
a) b) c)
Vertical stirrups, Bent-up bars along with stirrups, and Inclined stirrups
Where bent up bars are provided, their contribution towards shear resistance shall not be more than half that of the
total shear ~reinforcement, Vs Shear reinforcement shall be provided to carry a shear V t.bd. to be calculated as below
-
vs
A 5
. --
Where
44
.d. (Sina .f Cosca,) total cross-sectional area nf stirrup legs or bent-up bars within a distance s, spacing of the stirrups or bent-up bars along the length of the member, breadth of the member which for flanged beams, shall be taken as the breadth of the web,
b
a
a
= =
permissible tensile stress in shear reinforcement angle between the inclined stirrup or bent tip bar and
Where more than one type of shear reinforcement is used to reinforce the same portion of the beam, the total shear resistance shall be computed as the sum of the resistance for the various types separately. The areas of the stirrups shall not be less than the minimum specified in 304.7.1.5.
<<
IRC: 2 1-2000
0.4
.
415 MPa
b.s
0.87 1
onehalf the depth of the beam subject to a maximum of 300 rum. Stirrups shall pass round, or otherwise he secured to the appropriate longitudinal tensile reinforcement. The ends of stirrups shall be adequately anchored in the compression zone in accordance with Clause 304,6,4. Where for practical purposes it istbund necessary to anchor the ends of tile stirrups in the tensile zone. full anchorage length in accordance with Clause 304.62.2 shall be provided. 304.7,, 1 .7. Bentup bars shall b.c carried through a depth of at least equal to the lever arm of the resisting moment and adequately anchored in accordance with Clause 304.6.3.3. The spacing of th~ bentup bar measured at the level of neutral axis and in the direction of longitudinal axis of the beam shall not exceed three-quarter the effective depth of the beam. 304.7.2. Torsion
304.7.2. 1. General : In structures: where torsion is required to maintain equilibrium, menibers shall be designed for torsion. However, for such indeterminate structures where torsion can be eliminated by releasing redundant restraints, no specific design for torsion is necessary provided torsional stiffhess is neglected in the calculation of internal forces.. .Adeqi.iate control of any torsional cracking is provided by the shear reinforcement as per Clause 304.7.1. Torsional reinforcement is not calculated separately fbr torsion alone. Instead the total longitudinal reinforcement is determined for a fictitious bending moment which is a function << 39
mc : 21-2000
of actual bending moment and torsion; similarly web reinforcement is determined for a fictitious shear which is a
304.7.2.2. CrItical section: Sections located less than a distance d, from the face ofthe support may be designed for the same torsion as computed at a distance d, where d is the eflbctive depth. 304.7.2.3. EquIvalent shear 304.7.2.3.1. Equivalent shear, V~, hall be calculated from s the formula:
Where V~ V T b
= =
-
The equivalent nominal shear stress, ;, in this case shall be calculated as given in 304.7.1.1.1. except for substituting V by Y,. The values of; shall not exceed the values of t~ given
in Table 12A. 304.7.2.3.2. If the equivalent shear stress ; does not exceed;, given in Table 128, minimum shear reinforcement shall be provided as specified in 304.7.1.5. 304.7.2.3.3. If; exceeds those given in Table 128, both
<<
21-2000 longitudinal and transverse reinforcement shall be provided in accordance with 304.7.2.4.
IRC
torsion
304.7.2.4. i. Reinforcement for torsion, when required shall consist of longitudinal and transverse reinforcement. 304.7.2.4.2. Longitudinal reinforcement The longitudinal reinforcement shall be designed to resist an equivalent bending moment, Ml, given by Ml= M + M
e
Where
Al
bending
-
moment
T(1+Dfb)
Al
1)
h
1.7
=
304.7.2.4.2.!. If the numerical value of Al as defined in 3047,2.4.2. exceeds the numerical value of the mement Al, longitudinal reinforcement shall he provided on the flexural compression face, such that the beam can also withstand an equivalent moment Mt1 given by Me,=M,-M, the moment Me, being taken as acting in the opposite sense to the moment M. 304.7.2.4.3. Transverse reinforcement Two legged closed hoops enclosing the corner longitudinal bars shall have an area of cross section A~ given by A,,,
<<
=
--
T.s
V.s
IRC 212000 the total transverse reinforcement shall not he less than (re r~)b.s
Where
7 V 4,
:.::::
torsional moment shear force cross sectional area of bar forming the closed hoop spacing of the stirrup reinforcement centre to centre distance between corner bars in the
centre to centre distance between corner bars direction of the depth breadth of the member
=
in the
permissible tensile stress in shear reinforcement equivalent shear stres.s as specified in 304.7.2.3. I and
,
Table
304.7,2.5. Distribution of torsion reinforcement When a member is designed for torsion, torsion reinforcement shall be
provided as below
(a) The transverse reinforcement shall be rectangular closed stirrups placed perpendicular to the axis of the member, The spacing of the surrops shall not exceed the smaller of or 300 mm.
Where ~ and Y1 are respectively the short and long dimensions of the member.
(h)
In all cases there shall be at least one longitudinal bar in each corner of the stirrups. The diameter of these longitudinal bars shall not be less than the diameter of the stirrups or 12 mm
whichever is greater.
<<
IRC :21-2000
304.8.
Moment of inertia
the entire concrete section, including the reinforcement on basis of the modular ratio, or
the
the compression
area of the
reinforcement, on
the basis
Whichever method is adopted for the beams, the same method should be used for the columns. 304.8.2. Moment of inertia for calculating deflection: Appropriate values of moment of inertia may be used. 304.9. Temperature and Shrinkage Effects
304.9.1. The values of co-efficients ofthermal expansion and shrinkage of concrete shall be taken as follows (i) Thermal expansion
For reinforced concrete 1] 7 x lQ~per degree celsius
304.9.2. Every simply supported span shall be provided with means to permit both rotation and longitudinal expansion caused by the design loads and forces,
305. BEAMS AND SLABS
305.1. For bridges having beam and slab type of super-structure the number of longitudinals shall not be less than <<
43
1W : 21-2000
305.2. The minimum thickness of the deck slab including that at the tip of the cantilever shall be 200 mm. However, reduction in the thickness of the slab upto a maximum of so mm may be permitted at the cantilever tip subject to satisfactory detailing. The thickness of the webs shall not be less than 250 mm. 305.3. Cross girder monolithic with the deck slab shall be provided at the bearings. Intermediate cross-girders shall be provided depending on design requirements. The thickness of the cross girders shall not be less than the minimum web thickness of the main longitudinal girder. The depth of the cross girders at bearings shall be suitably adjusted to allow access fix proper inspection of bearings and to ficilitate positioning of jacks for future lifting up of the super-structure. 305.4. Effective Span 305.4.1. In the case of flee supports on line bearings, the effective span lo shall be the distance from the centre to centre of the bearings. 305.4.2. In the case of a free support, not on line bearings, the effective span lo shall be 1, + d or 1 whichever is
smaller,
Where 1
J
distance betvieen cenfl of supports clear span effective depth of beam or slab.
305.4.3. in the case of restraint at the support, the effective span may be taken as equal to the clear distance between the faces of the supports.
<<
44
!RC: 21-2000
3055.
Effective Depth
305.5. 1 The effective depth of a beam or slab shall be the depth from edge of the compressimi section to the centroid
TAN~
~f3
Fig. 9.
However, for calculating the moments in a haunched slab or beam, the actual varjation of moment of inertia in the span shall be considered. the member lying below or above a plane which makes a slope of I :3 with the horizontal shall be considered as adding to the effective depth.
portion of
<<
45
IRC 21-2000
305.6
(i) Beams When in a beam, part or all of the main is required to resist compression, links or ties atlea,st one quarter of the size of the largest compression bar should be provided at a niaximwii spacing of I 2times the size of the smallest compression bar. Links should he so arranged that every con-icr and alternate bar in an outer layer of reinforcement is supported by a link passing round the bar having an included angle of not more than 1350. All other bars within a compression zone shall he within 150 mm of a restrained bar,
reinforcement
(ii) Slabs When the designed percentage of reinforcement in the compression face of a slab exceeds 1 per cent, links of atleast 6 nini or one quarter the size of the largest
compress ion bar should he provided for a depth of 200 mm through the thickness of the slab.. If the thickness of the slab is. insufficient to accomniodate then it should be tied with the tension bar. The spacing of these links should not exceed twice the member thickness in either of the two principal directions, of the member or 400 mn-i and in the direction of the compression
force. not greater than 16 times the bar size. 305.7. Curtailment of Bars
305.7. 1, To prevent large changes in the monient of resistance the points a.t which the bars are curtailed shall be suitably spread. 305.7.2. In simply supported spans, at least 33 per cent of the steel required to resist the maximum bending moment shall he carried over the supports along the tension side of the beam and in the case of slab this shall not be less than 50 per <<
46
[RC 2 I 2000
\Vhcre the alignment of the reinforcement deviates from the normal to the plane of bending, as in the case of a beam with carved or sloped soffit, only the area of the reinforcement effective in the direction normal to the plane of bending shall be considered. 305.9. Lateral Support in Beams
in flanged beams with length between adequate lateral restraints greater thai-i thirty times the width of the compress ion flange, the permissible compressive stress in concrete shall be lo reduced by a factor equal to l.5--~ where ? is the unsupported length and b is the width of the compression flange of the beam. 305. I 0.
All thces of reinforced concrete member either fully exposed or lying within a depth of 500 mm below the level of perennial suhniergence under water, soil or soil-soil-water system shall be reinforced for shrinkage and temperature. This. reinfbrcenient shall be provided in two directions at right angles to each other in a plane parallel to the surface under consideration and shall he spaced at 300 mm maximum with 250 mm2 of steel area per metre in each direction for all grades of reinforcement. Reinforcing bars placed near the surface of a member in each direction to carry other loads may be considered as fully <<
47
IRC 212000
effective in providing reinforcement for shrinkage and temperature e.g. main longitudinal reinfbreement, distribution reinforcement in slabs, web reinforcement in beams and ties or helieals in
columns.
305.11.
Beams
The dispersion of the live load along the span length through the wearing coat. deck slab and filling shall not he considered.
305.12.
Beams
305.. 12. 1. When longitudinal beams are connected together
by transverse members like deck slab, cross girders, diaphragms
sof fit slab, etc., the distribution of bending moments between longitudinals shall be calculated by one of the following methods
(i ) Finding the reactions on the longitudinals assuming the supports olthe deck slab as unyielding. This method is applicable where there are only two longitudinals ~ ith no soflit slah~ Distributing the loads between longitudinals by (ourbons method, strictly within its limitation, i.e., when the effective width of the deck is less than half the span and when the stifihess of the cross girders is ~erymuch greater than that of the longitudinals; and Distributing the loads bet~~ longitudinals by aim rat~onal een method of grid analysis, e.g., the method of harmonic analysis as given by Hendry and Jaeger or Morice and Littles version of the isotropic plate theory of Guy on and Massonet, etc.
(d)
(iii)
305.12.2. In calculating the shear force on sections of longitudinal beams, wheel loads or ti-ack loads shall be allocated
<<
48
1RC: 2 1-2000
(b) (ii)
For loads more than 5.5 metres away from either supports
Distribution of the loads between the longitudinals for the purpose of finding shearing forces shall be assumed to he the same as for bending moments given in Clause 305.12.1.
305.13.
Dispersion of live loads along the span length through the wearing coat, deck slab aM filling shall not be considered. 30f.. 14. Distribution of Live Loads on Intermediate
305. 15.1. For T-beams or h-beams, the slab shall be. c.ons~deredas an integral part of the bean-i if adequate botid and shear resistance are provided at the junction of the slab a..iid the web of the beam. <<
49
IRC 21-2000
305.15.2. In the absence of a more accurate determination, the effective width for compression flanges of beams with solid webs and hollow box sections shall be taken as the following, but not exceeding the actual flange width.
b
+ +
b
Where
b
=
b,
h
The effective width shall be taken as constant over the In general, the effective width for tension flange may he taken as actual value.
entire span.
305.15 .3. if T-forni or L-form is used only for the purpose of providing additional compression area, such as in continuous
bw
Fig.
<<
10
~4bw
IRC
21-2000
beanis over supports, the flange thickness shall not be less than onehalf the width of tlie web and a total flange width not more than four times the width of the web. For effective stress transfer, it is desirable to splay the junction of the web and the flange so as to form an angle of not less than 110,as shown in
Fig. 10.
305.15,4. Where the principal reinforcement in a slab which is considered as the flange of a T-beam or Lbeam ~s parallel to the i:eam, transverse reinforcement shall he provided at the top of the flange. This reinforcement shall he equal to st ~ty per cent of the main reinforcement of the slab at its mid
s~n unless it is specially calculated. The length of such reinforcing bars shall he as indicated in Fig. 11
bw
~ ~
~:J4
1~ V
<<
Fig. 11
.1
-~
1 RC 212000
305.16.
305.16.1. TI-ic effect of concentrated loads on slabs spanning in one or two directions or on cantilever slabs: may he calculated from the influence fields o..f such loads or by any other rational metimd. A value o,f 0.. 1 5 may be assumed for Poissons ratio.
305.16.2. The bending moment per unit width of slab
caused by concentrated loads on solid slabs spanning in one direction or on cantilever slabs, may also be calculated by assessing the width of slab that may be taken as effective in resisting the bending moment due to the concentrated loads. ld)r precast slabs, ti-ic term actual width of slab used in this Clause shall indicate the actual width of each individual precast unit.
(I) (I) Solid slab spanning in one direction 1~ora single concentrated load, the effective width may be calculalted in accordance with the following equation
= a~(i
Whcrc I
= =
the effective width of slab on which the load acts, the effective span as indicated in Clause. 305.4, the distance of the centre of gravity of the concentrated load from the nearer support, the breadth of concentration area of the load, i.e., the dimension of the tyre or track contact area over the road surface of the slab in a direction at right angles to the span plus twice the thickness of the wearing coat or surface finish above the structural slab, and a constant having the following values depending upon the ratio where h is the width of the slab
<<
IRC :21-2000 Provided that the effective width shall not exceed the actual width of the slab. And provided further that in ease of a load near the unsupported edge of a slab, the effective v~ idth shall i~iolcxcced the aho~ value nor half the above value plus e the distance of the load ironi the unsupported edge. a (or sunph supported slat, 0.40 0.80 1.16 1.48 1.72 1.96 2.12 2.24 236 2.48 a for continuous slab 0.40 0.80 1.16 1.44 1.68 1.84 1.96 2.08 2.16 2.24 a for simpi) a for supported continuous slab slah 1.1 260
-~
I,
1.2
1.3 1.4
1.5
2.64
2.72 2.80 2.84
1.6
1.7 1.8 1.9 2 & above
2,88
2.92 2.96 3.00 3.00
2.28 2.36 2.40 2.48 2.48 2.52 2.56 2.60 2.60 2.60
ii)
lor two or more concentrated loads in a line in the direct m of the span, the bending moment per unit width of slab shall he calct.ilated separately for each load according to its appropriate effective width of slab calculated as in (I) above. For tao or mm e loads not in a line in the direction of the span If the effective width of slab for one load overlaps the effective a idth of slab for an adjacent load, the resultant effective a id0i for the two loads equals the sum of the respective effective a idths for each load minus the width of O\ crlap, provided that the slab so designed is lested for the two loads acting separately
(iii)
<<
I RC : 21 2000 (2) Solid slab cantilever (i) For a single concentrated load, the effective width may he calculated in accordance with the. followin,g equation
=
I.2a
Where
5,
the effective width, the distance. of the centre of gravi tv of the concentrated load from the thee of the cantiles er support, and the breadth of concentration area of load, i.e., dirnertsion of the lyre or track contact area over road surface of the. slab in a direction parallel to supporting edge ot the cantilever plus twice thickness ot wearing coat or surtbce finish above structural slab. the the the the the
a:?
=
Provided that the effective width of the cantilever slab shall not exceed onethird the length of the cantilever slab measured parallel to the support.. And pros~ded i fttrther that when the concentrated load is placed near one of the two extreme. ends of the length of cantilever slab in the direction parallel to the support, the effective width shall not exceed the above, value, nor shall it exceed half the above value plus the distance of the concentrated load from the nearer extreme. end measured in the direction parallel to the fixed edge. (ii) For two or more concentrated loads If the effective width of slab for one load overlaps the effective width of slab for an adjacent load, resultant effective width for the two loads shall be taken as equal to the sum of the respective effective width for each load minus the width of overlap, provided that the slab so designed is tested for the two
loads acting separately. Note : Slabs designed on the above basis need not be checked for
shear. (3)
<<
[FtC: 1-2000 2
]he effective width shall depend on the ratio of the transverse and longitudinal flexural rigidities of the slat,. When this ratio is one, that is when the transverse and longitudinal flexural rigidities aie approximately equal, the value of effective width as found for solid slal,s may le used. But as the ratio decreases, a proportionately smaller value shall he taken.
105.l6... Dispersion of loads along the span The effect of contact of wheel or track load! in the direction of span length shall b.c taken as equal to the (!inlcnsion of the tyre. contact area over the wearing surface of the slab in the direction of ti-ic spait plus twice the overall depth of the slab inclustve of the thickne.ss of the wearing surfitce.
305.16.4. Dispersion of loads through tills and wearing coat The dispersion of loads through fills and wearing coat shall be assumed at 45 degrees both along and perpendicular to the spa.n. 105 I 7.
.
105.. 1 7 I I.Jnsupported edges of all slabs shall be suitably sti tThncd as indicated in the following Clauses 305. 17.2. Each unsupported edge of a slab parallel to traffic and beyond the clear road width, shall be s.o stiffened as to give a resisting moment for any type of flexure equal to or in excess of lhat of a 300 mat strip of the main roadway slab adjoi fling the edge. In case of a roadway slab of unifonit depth, whether the reinforcement is oneway (parallel to or across the traffic) d)~ twoway, the maximum resisting moment of the roadway slab adjoining the edge and given by a 300 mm strip in any direction shall he taken as ti-ic criterion for the resisting moment or the stiffened edge. When the roadway slab is of varying depth in the direction parallel to the edge concerned, the stiffening at any particular point along the length of edge shall <<
55
IRC : 21-2000
be adjusted according to the resisting moment of the 300 mm
305. 17.3. Unsupported edge along a line across the traffic ot a roadway slab (as at the cantilever end of a solid slab cantilever bridge) shall, for a strip of at least 300 mn-i width in addition to the. articulation, if any be suitably stiffened by providing top and bottom reinforcement across the direction of traffic. The sectional area of such reinforcement for a 300 mm width of this strip, both at the top and bottom shall each be not less than the average area of longitt.idinal reinforcement for 300 mm width at the ct-id of the cantilever. 305.17.4. For cantileve.r shtb, minimum reintbrcement of 4 rtos. of 16 mm clia HYSD bars shall be provided parallel to th.e free edge at 150 mm spacing at the tip divided equally between th.c top and bottom st.irfaecs. 305.18. Distribution Reinforcement in Slabs
305. 18.1 .For solid slabs spanning in one direction, distributing bars shall be provided at right angles to the main tensile bars: to provide fbr the lateral distribution of loads. The distribution reinforcement shall be such as to produce a resisting moment in the direction perpendicular to the span equal to 0.3 times the moment due to concentrated live, loads pius 0.2 times the moment due to other loads such as dead load, shrinkage, temperature, etc. 30S 1.8.2. In cantilever slabs and in portions of supported slabs which never experience sagging moment, the total distribution steel ~ihallbe distributed half at the top and half at
<<
56
IRC : 21-2000
the. bottom of the slab.. For cantilever slabs the distribution steel shall be calculated on the basis of 0.3 times the live load moment pius 0.2 times th.c dead toad moment and for portions
of supported slabs on the basis of moments indicated in Clause 305.. 18.!. 305. 19.
The area of tension reinforcement in a beam shall be not Ie.ss than 0.2 per cent ofbt.d. when using Fe 415/500 grade bars or 0.3 per cent of ht.d. when using Fe 240 grade where bt is the breadth of section and d is the effective depth. For a box, 1 or I section ht shall be taken as the average width of concrete below the upper flange. In slabs ti-ic tension reinforcement shall be not less than 0. 12 per cent of the total cross-sectional area when. using Fe 4 15/500 grade bars and not less than 0.15 per cent of the total cross-sectional a.rea when using Fe. 240 grade bars. 30 5 ..i?0. Bending Moments The bending moments to be provided for at a crosssection of ~i continuous beam or slab should be. the maximum positive and negative moments at such crosssections, allowing, in both eases, if so desired, for the reduced moments due to the width of the supports, for the following arrangements of superimposed. loadings
(i) alternate spans loaded and all any
(ii)
Except where the approximate values of bending moments are. used, the negative moments at the supports for any as. sumed anangement of loading may each be increased or decreased by not more th%m iS per cent, provided that these modified negative <<
57
IRC :21-2000
moments are used for the calculation of the corresponding moments in the span.
306. COLUMNS AND COMPRESSION MEMBERS
306.1. Classification Columns can be classified under the following three categories U)
(ii)
Pedestal columns : Ratio of effective length to least radius ol gyration less than 12.
Short columns Ratio of effective len.gtl to least radius of gyration more than i 2 but less than 50. Long columns : Ratio of e.fk.cti ye length to least radius ot gyration more than 50 but less than 150.
(iii)
gyration for this clause, the crosssection of the column for c.:olumns with hinders and irt the case of columns with helic 211 rciniforccrncn.t, the section of the core within the outer surfisce of the helical reintbrc.emcnt shall be. considered. 306:. 1 .2. For purpose of this Clause the effective column length given in. Table 1.2 should be used, where 1 is the length of the. column, between adequately restrained supportii. The effective column length values given in this Table 13 arc in respcc.t of typical cases only and embody the general principles which sItc uldi he employed in assessing tfte appropriate value for any particular column. 306.2. Longitudinal Reinforcement 306.2.i. In a pedestal column the cross-sectional area of iong~tudinaieinfbrcemcnt shall be not less ti-ian 0.15 per cent of r the gross cross-sectional area of the column and in column other
<<
58
IRC : 21-2000 Table 13. Effective Column Length Type of column Properly restrained at both ends in position and direction Properly restrained at both ends in. position and imperfectly restrained in. direction at one Effective column length 0.75 1 A value intermediate between 0.75 / and I depending upon the efficiency of the directional restraint A value intennediate between / and 2/ depending upon the efficiency of the imperfect restraint
or both ends
Properly restrained at one end in position and direction and imperfectly restrained in both position and direction at the other end
1,1)
(2.) :3
2 /
1.75 /
Service condition with s nply supported spans on both sides. and pier tixed at base 1.2 /
Where / is the length of piers between surfhc es of restraint. For ah utrncnts the condit~on.s( 1) and (2) will generally apply.
than pedestal columns, the crosssectional area of longItudinal rcinlbrc.ement shall neither be less th.t.tn 0.8 per cent nor more han 8 per cent of th~egross sectional area o:f the. column.
.306.2.2. in any column other than pedestal columns: that has a larger crosssectional area than the minimum rtxiui red to resist the loads lncludlng the horizontal threes, the minimum pcrcen.tae of steel shah he based upon the area of concrete requ~ to resist the direct stress and not upon the actual area. red in any case the arc.a of stcc.l provided shall be not less than 0.3 per<< of ti-ic gross sectional area. of concrete. cent
IRC: 21-2000
306.2.:., A short or long rectangular column shall have a minimum of four longitudinal bars.. In case of columns with other than rectangular sections, there shall be one longitudinal bar placed near each angle point of the column. Short and long columns with helical or circular hinders shall have at least six longitudinal bars. 306.3. Transverse Reinforcement 306.3.!. A reinforced concrete column shall have transverse reinforcement in the form of lateral ties, circular rings or a helical. They shall be so arranged that every corner bar and alternate longitudinal bar near die face of the column shall have lateral support provided by ti-ic corner of a tie having an included angle of not niore than 135 degrees and no bar shall be farthe.r than 1 50 mm from such a laterally supported bar.. Where the bars arc located around the periphery of a circle, a. complete circular tie may he used. 306.3.2. The diameter of transverse reinforcement of any type shall not ordinarily he less than one-quarter the diameter of the largest longitudinal bar in that region of the colunin and in rio case less than 8 mm. 306.3.3. The pitch of transverse reinforcement shall not exceed 300 mm or the lesser of the following two dimensions .0) The least lateral dimension of the column.
(ii) Twelve times the diameter reinforcement in the column.
306.3.4. Where. the pitch actually adopted is less than the permissihle maximum as per Clause 306.3.3, the diameter of the transverse reinforcement may be reduced from that given in Clause 30(5. 3.2 subject to a minimum of 8 mm. But the volume <<
IRC: 2 1-2000 of lateral reinforcement calculated on the basis of diameter and maximum pitch given by Clauses 306.. 3.2 and 306.3.3 rt~spectivcly,shall not be reduced. 306.3.5. in case of helical reinfbrcement intended for the increased load capacity as per Clause 306.5.2, the heiica.1 reinforcement shall in addition to Clauses 306.3.2, 306.3.3 and 306.3.4 s.atis.fy the following requirements
fi) ltelica.l reinforcement shall consist of evenly spaced helicais and shall have their ends anchored. The splicing of the helicals shaH be made by welding or by a lap of one and a half turns. The pitch of the helicats shall not be more than 75 mm nor more than one sixth the diameter of the core of the column.
(ii)
306.4.
306.4,1. On a ~shortcolumn, reinforced with longitudinal bars and lateral ties, the permissible axial load N on the column shall not exceed the value obtained from the equation
~
C C
+~j~4
&C C
Where
cro
=:
the permissible stress in direct compression for concrete as given in Clause 303,
the permissible stress in direct compression for the longitudinal steel as given in Clause 303.2,
=
A,
the cross-sectional area of concrete exclusive of any finishing material applied after the casting of the column and exclusive ofthe areas of longitudinal steel, and the cross-sectional area of the longitudinal steel.
306.4.2. On a short column reinforced with longitudinal hl.trs and helicals complying with Clause 306.3.5, the perrissiblc ~:ixi~ti oad N on the column shall not exceed that given, by the l equation in Clause 306.4. 1 or by the equation given below <<
IRC 21-2000
whichever is greater
N Where
ito
rr
2 a ~r 95 .A the cros:s-scctional area of concrete in the column core, excluding the area of longitudinal steel,
=
C C
a oil o
SC
44 .5 -f
the equivalent area of helical reinforcement (i.e., the volume of helical reinforcement per unit length of the
The sum of the terms coA o and 2 a A shall not 4ic sflcngth of exceed 0 S fkAc where i~ the characten concrete. 306~43. In case of a long column reinforced with longitudinal bars and ties or helical reinforcement, the pemiissible axial load on the column shall be obtained from the equations given in Clauses 306,4.1 and 306.42 respectively provided reduced values of permissible stress for steel and fbr concrete are taken uch reduced values of the maximum permissible stresses shall he. obtamed by multiplying the appropriatc maximum penmsstbie stresses given in Clauses 306.4. I and 306.4~2by the coefficient B given by the equation
[OUr wl~ie.re 1
C:
the reduction coefficient, theefic:iive length ot the column, and the least radius of gyration
..:;;.;
c.
Note
When in a column having helical reinfbrcement, the perrnis:sible load is based on the core area, the radius c: I gyration shall also be based on the di arneter of the cure,
<<
62
306.5. 306.5.i.
IRC: 2 1-2000 Design of Sections for Combined Axial Load and Bending
When reinforced concrete section under axial compression is subjected to bending in one or more directions, the section shall be designed by any recognised rational niethod or by the method given in Clauses 306..5.2 to..306.5,4.
306.5.2. The maximum direct stress and bending stress in t.he section shall be calculated by the following methods (1) fi) Direct stTess For columns with helical reinforcement complying with Clause 306.3.5. N Direct stress ,4o (ii)
5
ccAs
2.cx.14sp
For columns with transverse, reinforcement other th.art that in (i) above. N Direct stress A
f
cx. A .4,!
(1) N 1
Bending stress the k:nu.l on the column in the direction of its axi.s, the area ol concrete section perpendicular to the of the c.cfluniri the modular ratio, the. scct~ou modulus (in case o thending in d~reetinns,,W is tlie section niodt.iiu.s w~threftirence to the appropriate principal axis for twowa bending), and
.L9:M
is
<<
:4.!
Dl0111011
1RC 2 1-2000
by
fv
in
Where
.4!~and A! are the bet ding moments about two principal axis of the section and B, and W iu~ethe corresponding section moduli.
306.5.3. If the direct and the. bending stresses, calculated from cquatiotis given in (1) and (2) ol Clause 306.5.2 satisfy all the. following conditions, the sectton may be constdcned safe
ca, cal
C,, cal
0)
Where c~o, al c
GO
C:;
+
CC
the calculated direct compressive stress, the permissible direct compn ssive stress, according to Clause 30.3, multiplied by the reduction factor given in Ctause 306.4.3. the. calculated ilexural compressive stress, and the pennissible tiexural compressive stress, according to Clause 303, muitipl~ed by the reduction co-efficient given in Clause 306.4.3.
ci,, cal
(ii)
The resultant tension due to direct compression and flexure is not greate.r than the value spec ifiocl in Table. 11 for the appropriate grade of concrete mix,
306.5.4. If the condition given in Clause 306.5 .3 (ii) is riot satisfic.d, the section shall be deemed to have cracked in the. region of tension and the tensile resistance of concrete is <<
IRC 21-2000
ignored altogether. The maximum stresses in concrete and steel shall the.n be found according to the recognised theory of cracked section. The fibre compressive stress in concrete shall not exceed the values given fbr flexural compressive stress as given in Table 9 and those fbr tens ion in steel shall not exceed the pennissible. stress in reinforcement givert in Table i 0. 307. FOOTING OR BASES 307. 1. Allowable Press tire on the i..4oaded Area The allowable bearing pressure aCC with near uniform distribution on the loaded area of a footing or base. under a bearing or coiunm shall be given by the following equation
C,,.
=
~~,: ~
Where no
the permissible direct compressive stress in concrete at the bearing area of the base. dispersed concentric area which is geometrically similar to the loaded area A, and also the largest area that can be contained in the plane of A, (maximum width of dispersion beyond the loaded area face shall he limited to twice the height)
C;
The projection of the base or footing beyond thelace of the bearing or column supported on it shall not be less than 150 mm in any direction. Adequate reinforcement for spalling and bursting tension shall he provided with small diameter reinforcement at close << tpacing.
IRC 21-2000
307.2.
Desigit of Footing
307.2,1.
moments at any section of base for a reinforced concre.te column or wall shall be taken to be the moment of the forces over the
entire area on one side of the section. The critical section for bending in the bases shall be taken at the face of the column or ssal 1. 307.2.2. Shear
-
30~7 .2.2.1. The shear strength of the footings shall be go. verned by the severer of the following two conditions.
(a) The footing acting essentially as a wide beam, with a critical section extending in a plane across the entire width; the critical section for this condition shall he assumed as vertical sectioin located from the face of the column, pedestal or wall at a distance equal to the effective depth of the footing. Two way action for slab or footing with a critical. section perpendicular to plane of slab and so located that its: perimeter is mini mum but need not approach closer than half th.e effective depth to the perimeter of concentrated load or reac~ionare.a.
(h)
307.2.3. Bond The. critical section for checking the loc..al bond stress shall he taken to be the same. section. a.s given ~n Claw:e 307.2. 1 and also all other vertical planes where abrupt .changc.:s in section o~cc.ur.
Tensile. reinforcement The reinforcement provided to resist the bendtng moments determined in Clause 307,2, 1 shall be. distributed uniformly across the full width of the section except that in rectangular footing.s for columns or p~edcslais,the rcinfbrccment parallel to the short edge shall he
more closely spaced near the column or pedestal in a band width, equal to the short side of the [doting. The reinforcement irt band width shall be as given below <<
:107.2.4
JRC: 2 1-2000
(13
Where 13 is the ratio of the long side to the short side ~of thc fboting. :307.2.5.
307.2.5.1. General The pile caps shall he designed either by tnr..:s analogy or by bending theory. 307.2.5.2. Design by truss analogy The thickness of pile cap shall he so propot-tioned to act as sti if m ember. The minimum thiclc.ness of cap shall he 0.5 times. the spacing oi the Ic where there are two rows of piles. The truss should he a triangular form with a nodt:~at the centre of loaded area. The lower node of the truss lie at the intersection of the centre line, of the pile.s with the tension reinforcement. When the truss method issued with widely spaced piles (spacing exceeding three times the pile diameter) only the reinforcement with in 1.. 5 times the. pile diameter from the centre of a pile shall he considered to constitute a tension nurnher.. Eighty pc~r cent of the total reinforcement shall he c.oncentrale,d in s.trip...s linking the pile h.ead.s and the remainder uniformly distributed throughout the. pile cap. No check ibm shear is required to be carried out in case pile caps are designed by truss analogy. 307.2.5.3. Design by bending theory The bending moment at any section of the cap for a reinforced concre.te
column or wall shall be taken to be the moment of the forces over the. entire area on one side .of the section. The critica]
<<
67
IRC :21-2000
section for bending in the cap shall be taken at the face of the
column or ~vaIi
3O7.2.5~4. Check for shear The critical section for checking shcar shall be taken at a distance of effective depth (corn the face of the column or wall for caps acting in one d~rccttonand at a dtstance of half the effective depth for caps acting in two directions, Shear on any section for a pile cap shall be in accordance with the following
(a) Entire reaction from any pile where its centre is located at a distance half the pile diameter or more outside the section shall he considered as producing shear on that section, Reaction from any pile where centre is located at a distance half the pile diameter or more inside the section shall he considered as producing no shear ott that section. For intermediate positions of pile centre, the portion of the pile reaction to he considered as producing shear on the section shall he hased on straight line inter-polation between full value for condition (a) and zero value for condition (b).
(is)
(c)
1O7~2~5.5. Check for punching shear The punching shear shall hc~checked both around the column and the pile on a perimeter, as shown in Fig. 12.
i)i9n~etc~r f o
Ther or PUc
<<
68
IRC: 2 1-2000
j71
CONTINUOUS
CONSTRUCTION
308. 1.
.
Moments
308. 1 1. At sections where the dead. load moment i~of as ig,n opposite to that of the live-load moment, the d.esign bending r.ioment tom this condition of loading shall be taken a.s equal to the live load moment plus. C). 7 dead loa.d moment, with proper signs. This condition of loads shall he allowed for in design i.n addition to the other nonnal load conditions. However at least 2.0 per cent of the maximum negative, reinforcement at the support shall he carried out right across the span even if not required l.y design calculations. 308.2.
,
ArticuLations
:308.2. I The design of hearings at articulations: shall ensure that concentrated edge stresses will not he induced and the, angular rotation of the cantilevers and the suspended span is Possible iv ithout any damage to the articulation. 308.2.2.. The slope and arrangement of reinforcemnent of articulation shall he as in the. Fig. 13(a) arid (b). 30K3. Distribution of Reinforcement in the Ten!.ile Flange
Where the. flanges of T-he.ams are subjected to tensile stme;sses in longitudinal direction, the bars of the principal meii,iforce,ment shall he suitably distributed along the flanges with somne concentration at the position of the web.
<<
69
IRC : 21-2000
At
c~i(VAih
_I_,__ In
Lfl*M~
30~. . Effective Compression Flange Width 1 For calculating stresses at any section of a box. girder the effective: width of the slab ilinctioning as the compression flange shall be in accordance with Clause 305.15.2. 309.2. SoRB Slab Thickness The minimum thickness of the bottom flange shall be detennined by the maximum allowable stresses specified in Clauses 303.1 and 303.2 but in no case shall it be less than 200 mm or one-twentieth of the clear span between the main girders, whichever is greater. The thickness of the deck slab and webs shall not he less than that stipulated in Clause 3052.
<<
70
IRC: 21-2000 309,3. Reinforcement of Soffit Slab Minimum reinforcement of 0.5 per cent of the flange section for Fe 240 grade bar or 0.30 per cent of the flange section for Fe 500/415 grade bars shall be placed in transverse direction distributed equally over both surfaces. Bar spacing shall not exceed 300 rnn~.These bars shall be bent up into the exterior girder stems at least ten times the bar diameter. In the longitudinal direction, the longitudinal steel needed from stress consideration may be distributed equally between the top and the bottom surfaces and also it must be ensured that each surface has atleast the minimum reinforcement specified in Clause 305.10. 309.4. Reinforcement in the top flange in a direction transverse to the girders shall extend to the exterior face of all outside girders, and a minimum of one-third of such reinforcement s.hall either be anchored with 90bends or extended beyond the girder face a sufficient distance to develop the strength of the bar in bond provided the flange projects beyond the girders face a sufficient distance to provide this bond length. 309.5. The minimum clear height inside the box girders shall be 1.5 m to facilitate inspection. WORKMANS1.IP Concrete
310.
310.1.
Measurement of ingredients: All the ingredients of concrete, i.e., cement, fine and coarse aggregates and water and admixtures, if any, shall be determined by weight. Due allowance shall be made for the weight of moisture present in the aggregates. 310.2. 3.10.2.1. << Proportioning Ingredients of Concrete The proportions of cement, aggregates ant
71
IRCH 2 1-2000
water niay he determined by any of the recognised methods of proportioning provided that all the requirements of Clause 303 are satisfied. 310 2. Accurate control shall be kept on the quantity of mixing water, which when specified, shall not be changed without the approval of the competent authority. 310,3. Mixing Concrete
All concrete. shall be niachine-mixe~In order to ensure uniformity and good quality of cone rete, the ingredients shall be mixed in a power driven batch mixer with hopper and suitable weigh batching arrangenient or in a central mix plant. The concorte shall he mixed until it is of even colour and uniform consistency throughout. In no case shall the mixing be done for less than two minutes after all the ingredients are in the mixer. The addition of water after the completion of the initial mixing operation shall not be permitted. 310.4. Transporting Concrete
3lft4.1. Mixed concrete shall be transported from the ~~~acc c,~fmixing to the place. of final deposit as rapidly as practicable by methods which will prevent the segregation or loss of the in~~redients depcs ited as near as practicable to its and final position to .avoid rehandling or flowing. Concrete may be transpori.ed by transit mixers or properly designed buckets or by pumping. Transit mixers or other hauling equipment when used shoi.ild be equipped with in cans of discharge of concrete without segregation. The maximum period between the addition of water to the
<<
72
IRC 2 1-2000 mix and the placing and compaction of concrete in final position shall not exceed 30 minutes or the initial setting time of the cement whichever is less, excepting in the case where retarders are used. 3 10.4.2. When concrete. is conveyed by chute, the plant shall he of such size and design as to ensure practically continuous flow in the chute. The slope of the chute shall he such. as to aIlow the concrete to flow without the use of an cxc.essive quantity of water and without segregation of the ingredients. The delivery end of the chute shall be as close as possible to the point of deposit. The chute shall be thoroughly flushed with water before and after each working period and the water used for this purpose discharged outside the foniiwork. 310.5. Placing and Compacting Concrete
310.5.1. The concrete shall be placed before setting has commenced and shall not he subsequently disturbed unless retcmpering is specially perniitted. Concrete shall be.~soplaced .as to avo.id segregation of the materials and displacement of reinforcement. To achieve this. concrete should be lo\vered vertically in the fonns and horizontal movement of concrete inside the forms should as far as practicable be brought to a minimum. In wall forms drop chutes attached to hoppers at the top should prekrably he used to lower concrete to the bottom of the form. l...Jnde.r no circumstances concrete shall be dropped freely from a height of more than 2 metre. 3 10.5.2. Concrete shall be thoroughly compacted during the operation of placing, and carefully worked around the reinforct~ment, round embedded fixtures and into the corners of a the form work,. To achieve proper compaction vibrators shall he used. The vibrator c.an he internal or external types and << depending upon the shape. and size ofthe member both th.e types
LRC: 21-2000 together shall be used. When internal vibrators are used they shall be inserted vertically to the flu depth of the layer being placed and ordinarily shall penetrate the layer below for a few centimetres. The vibrator should be kept in place until air bubbles cease escaping from the surface and then withdrawn slowly to ensure that no hole is left in the concrete, care being taken to see that it remains in continued operation while being withdrawn. The internal vibrators shall be inserted in an orderly manner and the distance between insertions should be about i~ times the radius of the area visibly affected by vibration. 310.5.3.
Construction Joints
310.5.3.1. Concreting shall be carried out continuously upto constn.iction joints, the position and arrangement of which shall be pre-determined by the designer. 31 0.5.3.2. For a vertical construction joint, a stopping hoard shall b.c fixed previously at the pre-determined position and it shall be properly stayed to have sufficient lateral rigidity to prevent displacement or bulging when concrete is compacted against it. Concreting shall be continued right up to the board. The hoard shall not be removed before the expiry of the period specified in Clause 310.10 for removal of vertical forms. Preparation of the concrete surface and resumption of concreting shall he in accordance with Clause 310.5.4. 310.5.4. Before resuming work at a construction joint when concrete has not yet filly hardened, all laitance shall be removed thoroughly, care being taken to avoid dislodgement of coarse aggregates.
<<
IRC : 2 1-2000
hardened, it should be thoroughly hacked, swept clean, wetted and covered with a layer of neat cement grout. The neat cement grout shall be applied to the surface and this shall he followed by a 10 mnni thick layer of cement mixed in the same proportion as that of cement arid sand in concrete and the concreting s.hall be resumed immediately thereafter. The first hatch of concrete shall be rammed against the old work to avoid formation o.f any stone pockets, particular attention being paid to corners and closed spots. 310 5. The sequence. of concreting, striking of forms and positioning of bearings for every individual structure shall he decided, well in advance of the commencement of work. 310.6. Spacers may be embedded in concrete provided that the quality of the effective cover of any part of the structure is not reduced below the standard required by this code. To ensure adequate cover use of manufactured chairs: is recommended. 310.7. Ctiring and Protection of Concrete
The concrete should he kept constantly wet for a minimum period of 14 (fourteen) days except for rapid hardening cement concrete when it can be reduced to 5 (five) days. Water should he applied on unfornie.d surfhces as soon as it can be done without marring the surface and on formed surfiices immediately after the forms: are stripped. The concrete. ~ I he kept constantly wet by pond~ngor covered with a luer of sackin~g., canvas, hessian or a similar absorbent material and kept constantly wet. After placing and during the. first stages of hardening concrete shall he protected from harmful effects of sunras, drying winds, cold, running water, s:hocks, vibrations, traffic including construction traffic etc. <<
1RC
21-2000
310.8.
31(18.2. 1. When depositing concrete at or near freezing temperature, precautions shall he taken to en~~tire that the concrete shall have a temperature. of at least 5Cwhile placing and that temperature of the concrete shall be maintained above 4Cuntil it has thoroughly hardened. 310.8.2.2. When necessary, concrete ingredients shall he he,ated before niixing but cenient shall not he heated artificially o.ther than by the heat transmitted to it from other ingredients of the concrete. In general, heating of the mixing water only to about 66C may suffice for this purpose. 310.8.2.3. No frozen material or materials containing ice shall be used. 31(18.2.4. All concrete damaged by frost shall he removed, 310.9.
.
Steel Reinforcement
310.9.1 Bending : Reinforcement shr.ll not he. bent or straightened in a manner that will injure the material. All reinforcenient shall be bent cold. 310.9.2. Placing : Al I reinforcement shall he placed and maintained in positions shown on the drawings. <<
-
IRC: 2 1-2000
310,9,3. Splicing and lapping Splicing and lapping shall he in positions conforming to the drawings amid for this purpose all reinforcing bars shall be to the full lengths indicated thereon. The competent authority may, however, make suitable adjustment in the locations of the splices to accommodate the available lengths of bars. En all cases of such adjustment, the requirements of lap length and other stipulations, as per Clause 304.6.6 must be complied with. 310.9,4. Substitution of bar sizes : in other to accommodate the available size of bars, use of bar size other than those shown on the drawings may be permitted by the competent authority. in case of such substitution, the reinforcement actually used shall have an area equivalent to the original or slightly in excess thereof, provided further that the various stipulations of this Code are not violated by such substitution. The requirements with regard to bond stress, limitations of bar sL~..es,spacing of bars, and cover, etc., shall he specially looked into. 310.10. Falsework
For design, fhbrication, erection and stripping of false work, IRC:87 Guidelines for the Design and Erection of False Work for Road Bridges shall be followed, The form work should he robust and strong and the joints should be leak proof. The staging, scaffolding and shuttering are required to be properly designed so that their erection as well as striking can he conveniently done. The design should a~o ensure that at the time of striking, the concrete does not get disturbed and the forms are conveniently removed. Use of bamboo staging shall be prohibited. Ballies staging shall he checked for its soundness and
<<
77
LRC :21-2000
shall be properly braced to make it rigid and strong. Vertical splicing of ballies shall not be permitted. Where centering trusses or launching trusses are adopted for casting of superstructure, the joints of the centering or launching arrangement, whether welded, reverted or bolted shall be thoroughly checked and various members of the centering trusses shall be examined for proper alignment and unintended deformation before proceeding with the concreting. The location where fixing of reinforcement and placing of concrete art~.being done, shall be accessible to the inspecting officers at all stages of construction. 310.11. Tests
310. Ii.!. Tests of cement, aggregates, water etc., to satisfy the requirements of Clause 302 shall be carried out for designing the mix of design mix concrete in accordance with relevant ISI Codes.. These tests may also be carried out while arriving at the proportions of ingredients in the case of nominal mix concrete if required by the competent authority. 310.1 i .2. Tests of reinforcing steel, cement, aggregates and water actually used at site for production of concrete plain or reinforced and if any grade shall be carried out to satis& the requirements of Clause 302 and in accordance with relevant IS! Codes. 3 10.11.3. Load tests on the completed structure may be car,ied out if specially desired.
<<
78
IRC: 21-2000
Appendix / (303~4~2) DESIGN SURFACE CRACK WIDTH AA. The design crack width may be calculated from the following equation Design surface crack width Where
c~
=
(hx)
is the minimum cover
to
is the perpendicular distance from the point considered to the surface of the nearest longitudinal
bar;
=
is the average strain at the level where cracking is being considered calculated allowing for the
[12kh(ax)]l0~~
A,i~hx)f,~
Where
b 1
=
is the distance from the compression face to the point at which the crack width is being calculated;
is the overall depth of the member; is the average strain at the level where cracking is being considered, calculated ignoring the stiffening effect of the concrete in the tension zone; is the depth of the neutral axis found from the analysis to determine e~
x A
<<
mc 21-2000 A negative, value of indicates that the section is uncracked. In assessing the stra.ins the modulus of elasticity of the concrete should be taken as half the instantaneous value. A.2. Permissible crack width: The crack width under sustained loads shall not exceed 0.2 mm for severe conditions of exposure and 0.3 mm for moderate condition of exposure. The conditions of exposure are gi ~enin Table 4 and the sustained loads niay be taken as dead load pius 50 per cent of live load.
<<
80