NINT-xx BOARD CONFIGURATION For ACS600 400V, 500V and 690V Series For ACS611 Series
WARNING! DO NOT ATTEMPT ANY WORK ON A POWERED ACS600! AFTER SWITCHING OFF THE MAINS, WAIT FIVE MINUTES BEFORE ATTEMPTING ANY WORK ON THE UNIT! For more details, see Safety Instructions in the ACS600 Installation & Start-up Manual, pages iii - v.
CAUTION! Electrostatic discharge (ESD) can damage electronic circuits. Do not handle any components without following the necessary ESD precautions. For more details, see ABB Industry Oy ESD Directive, codes 59240803 and 59240790. If unavailable, contact ABB Industry, Helsinki.
OVERVIEW Note: This document applies to ACS600 400V, 500V and 690V series and ACS611 series. This paper gives instructions for hardware board configuration that must be carried out as the NINT board is replaced.
ABB Industry Oy
Dept Prepared Updated
58946231
00012711.DOC Revision Page
TJX
T Hartikainen
L Nuutinen
02/08/201 2
J Kokkonen
2/ 4
NINT (MAIN CIRCUIT INTERFACE) BOARD REPLACEMENT: HARDWARE CONFIGURATION The NINT-xx board must be configured for the particular type of converter prior to replacement. The board has special configuration pad pairs on the solder side (see Figure 1 below), and these pads must be connected by soldering according to Table 2. Note that on the NINT-45 board there are two pad pairs labelled 1, two pad pairs labelled 2 and two pad pairs labelled 3. NINT-46 is labelled likewise from 1 up to 5.
NINT-46
Converter Type: ACS6xx-0011-3 According to Table 2, pad pairs labelled 3 are to be connected by soldering.
5
Connect by soldering
5 4 3 2 1
4 3
1 2 3 4 5 6 7 8
Connect by soldering
Connect by soldering
2 1
NINT-45
Converter Type: ACS6xx-0005-3 According to Table 2, pad pairs labelled 1 are to be connected by soldering. Connect by soldering
Connect by soldering
11 12 13 14 15 16 17 18
Connect by soldering
ABB Industry Oy
Dept Prepared Updated
58946231
00012711.DOC Revision Page
TJX
T Hartikainen
L Nuutinen
02/08/201 2
J Kokkonen
3/ 4
NINT Type
(NINT 44)* (NINT 44)* NINT 45 NINT 45 NINT 45 NINT 46 NINT 46 NINT 41 NINT 41 NINT 42 NINT 42 NINT 42 NINT 42 NINT 42 NINT 42 NINT 42 NINT 43 NINT 43 NINT 43 NINT 43 NINT 43
NINT Type
(NINT 44)* (NINT 44)* NINT 45 NINT 45 NINT 45 NINT 46 NINT 46 NINT 51 NINT 51 NINT 52 NINT 52 NINT 52 NINT 52 NINT 52 NINT 52 NINT 52
R8 Axx 60x-0170-5 NINT 53 R8 Axx 60x-0210-5 NINT 53 R8 Axx 60x-0260-5 NINT 53 R9 Axx 60x-0320-5 NINT 53 R9 Axx60x-0400-5 NINT 53 *) NINT-44 is not used in units manufactured after week 9620. (Serial numbers 620 000 )
ABB Industry Oy
Dept Prepared Updated
58946231
00012711.DOC Revision Page
TJX
T Hartikainen
L Nuutinen
02/08/201 2
J Kokkonen
4/ 4
NINT Type
NINT 66 NINT 66 NINT 66 NINT 66 NINT 62 NINT 62 NINT 62 NINT 62 NINT 62 NINT 62 NINT 62 NINT 62 NINT 63 NINT 63 NINT 63 NINT 63 NINT 63 NINT 63
Table 4. Axx 611 - 380V 500V Frame Axx 611 Type NINT Type
R5Q R5Q R5Q R5Q R5Q R5Q R5Q Axx 611 0025-5 Axx 611 0035-5 Axx 611 0040-5 Axx 611 0050-5 Axx 611 0060-5 Axx 611 0070-5 AWI 611 0075-5 NINT 41 NINT 41 NINT 42 NINT 42 NINT 42 NINT 42 NINT 42