Sonora 4SPI-20 Polarity Locker Power Inserter - 20 Volts
Sonora 4SPI-20 Polarity Locker Power Inserter - 20 Volts
Sonora 4SPI-20 Polarity Locker Power Inserter - 20 Volts
F E AT UR E S
DE S C R I P T I ON
APPL I C AT I ON NOT E S
SS I T UAT I ON
FF E AT UR E S
DE S C R I P T I ON
AAPPL I C AT I ON NOT E S
Contact: Sonora Design Associates t 805.644.8913 t www.sonoradesign.com t info@sonoradesign.com
Revised Mar 15 2012
DBS devices require DC voltages on the coax input
or output connector and the RF signals must pass
through the power inserter.
Sonora power inserters couple regulated DC voltage
on coax cables while allowing the DBS signal to
pass through the inserter. DC Power originates from
switching, short circuit protected transformers.
DBS devices operate at a range of voltages and
currents. Power inserters and a power adaptors are
sold separately or packaged together. DC can be
inserted in one direction (HRFPI) or both directions
(HRFPIB) on the coax.
DBS compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . DBS Ka/Ku
Frequency Response . . . . . . . . . . . . . . . 2 MHz to 2400 MHz
Indoor/Outdoor Case: . . . . . . . . . . . . . . Die cast RF shielded
Switching Power Supply: . . . . . . . . short circuit protected
. . . . . . . . . . . . . . . . . . . . . . . . . . . Regulated Output Voltage
Power inserters couple DC power on coax cables to
DBS LNBs, line amplifers and switches.
HRFPI ................................................................... 2 -2400 MHz
..........................(1) Polarity single direction inserter
HRFPIB................................................................. 2 -2400 MHz
..............................(1) Polarity bidirectional inserter
4SPI ..................................................................... 2 -2400 MHz
......................(4) Polarity single directional inserter
PS2x8 ...................................................................... DC Splitter
.............................. (2) F DC INPUTS to (8) F DC OUT
PS12250 .......................................................... 12 V, 0.25 Amp
.........switching regulated F connector transformer
PS121000A ........................................................12 V, 1.0 Amp
........ switching regulated F connector transformer
PS201200 ...........................................................20 V, 1.2 Amp
.........switching regulated F connector transformer
PS242000A ........................................................24 V, 2.0 Amp
.............switching regulated F, AC cord transformer
4SPI-20 ...............................................................20 V, 1.2 Amp
............................................. & 4SPI (4) polarity inserter
HRPIR20 .............................................................20 V, 1.2 Amp
..................................& HRFPI single direction inserter
HRPIR242 ...........................................................24 V, 2.0 Amp
..................................& HRFPI single direction inserter
HRPIR242B .........................................................24 V, 2.0 Amp
.................................... & HRFPIB bidirectional inserter
PS8-242000 ................................................. (1) 24 V, 2.0 Amp
......................................................... & PS2x8 DC splitter
PS8-244000 .................................(2) 24 V, 2.0 Amp Supplies
......................................................... & PS2x8 DC splitter
SOLUTION
RELATED CONSIDERATIONS
4SPI
HRFPI HRFPIB
POWER SUPPLIES
C
O
A
X
D
C
I
N
S
E
R
T
E
R
S
PS2x8
PS201200
PS242000A
Contact: Sonora Design Associates t 805.644.8913 t www.sonoradesign.com t info@sonoradesign.com
Revised Mar 15 2012
2 POWER SUPPLIES
L
N
B
P
O
W
E
R
I
N
G
SINGLE LNB POWERING
PS
20
1200
HRF
PI
16 V
Min
95
A stacked polarity LNB or
even polarity LNB requires
a mi ni mum of 16 vol ts at
its input. Model HRFPIR20
power i nser ter s i ncl ude
model HRFPI and model
PS201200 power supply.
LNB current is typically less
than 200 mA. Usi ng soli d
copper RG-6 coax with a loop
resistance of 4 ohms per 100,
the maximum cable length
can be calculated.
(20 V - 16 V) / (4 ohms x 0.2
Amp) = 500 feet.
Model SL5 LNBs employ current management to
minimize the current carried per coax. (500 mA total)
18 V = 200 mA, 18V 22kHz = 200 mA, 13V = 50 mA, 13V
22kHz = 50 mA.
SL5 POWERING
24 Vdc 2 Amp
18 Vdc, 0.2A 16 Vdc Minimum
16 Vdc Minimum
(4) coax to SL5
SWM8 Powering of SL5
Legacy 1
Legacy 3
Legacy 2
OFF-AIR
SWM1 PWR
SWM2
SWM8
99/101
103/110
/119
18V 13V
18V
22k
13V
22k
Flex
Port1
Flex
Port2
24V
2A
HRPIR
242B
18 Vdc, 0.2A
13 Vdc, 50mA
13 Vdc, 50mA
101
99
SL5
103
110 119
200 ft Max
Starting at 18v, the max Switch to LNB distance is 200ft.
Increasing the voltage to 20 volts allows the dish to be
up to 400 feet from the LNB (includes the in-line current
to power the LA144a amplifers)
4SPI S1 S2 S3 S4