Contents

7 - Control relays

Control relays
b k control relays v For a.c or d.c control circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/4 v For d.c control circuit (low consumption) . . . . . . . . . . . . . . . . . . . . . . . page 7/5 v Instantaneous and time delay auxiliary contact blocks . . . . . . . . . . . . page 7/6 v Mounting and marking accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/7 b Mini-control relays v Mini-control relays CA2 SK and CA3 SK . . . . . . . . . . . . . . . . . . . . . . page 7/12 v Mini-control relay with alternating contacts CA2 SKE . . . . . . . . . . . . page 7/12 v Instantaneous auxiliary contacts and coil suppressor modules . . . . . page 7/13 b TeSys d control relays and add-on blocks v Control circuit: a.c., d.c. or low consumption, . . . . . . . . . . . . . . . . . . page 7/21 v Add-on blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/22 v Accessories and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/23

Zelio Time: timing relays


Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/26

Zelio Control: measurement and control relays


Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7/28

7/1

Characteristics

Control relays
k control relays

Environment
Conforming to standards Product certifications Operating positions IEC 60947, NF C 63-140, VDE 0660, BS 5424 UL, CSA

Vertical axis

Horizontal axis

Without derating

Without derating

Connection Screw clamp connections Solid cable Flexible cable without cable end Flexible cable with cable end Solid cable Spring terminals Flexible cable without cable end Faston connectors Clip Solder pins for With locating device between printed circuit board power and control circuits Tightening torque Philips head n 2 and 6 Terminal referencing Conforming to standards EN 50005 and EN 50011 Protective treatment Conf. to IEC 60068 (DIN 50016) Degree of protection Conforming to VDE 0106 Ambient air temperature around the device Maximum operating altitude Vibration resistance 5...300 Hz Flame resistance Storage Operation Without derating Control relay open Control relay closed Conforming to UL 94 Conforming to NF F 16-101 and 16-102 Control relay open Control relay closed Conforming to VDE 0106 and IEC 60536

mm2 mm2 mm2 mm2 mm2 mm

Min. 1 x 1.5 1 x 0.75 1 x 0.34 1 x 0.75 1 x 0.75 2 x 2.8 or 1 x 6.35 4 mm x 35 microns 0.81.3 Up to 8 contacts

Max. 2x4 2x4 1 x 1.5 + 1 x 2.5 1 x 1.5 1 x 1.5

Possible positions for CA2 K only, with derating, please consult your Regional Sales Office. Max. to IEC 60947 1 x 4 + 1 x 2.5 2 x 2.5 1 x 1.5 + 1 x 2.5 2 x 1.5 2 x 1.5

N.m

C C m

"TC (Klimafest, Climateproof) Protection against direct finger contact (devices with screw clamp terminals or pins for printed circuit board) - 50...+ 80 - 25...+ 50 2000 2 gn 4 gn Self-extinguishing material V1 Conforming to requirement 2 10 gn 15 gn SELV (Safety Extra Low Voltage), up to 400 V

Shock resistance (1/2 sine wave, 11 ms) Safety separation of circuits

Control circuit characteristics

Control relay type Rated control circuit voltage (Uc) Control voltage limits For operation (y 50 C) single voltage coil For drop-out Mechanical durability at Uc 50/60 Hz coil In millions of operating cycles Standard c coil Wide range, low consumption c coil Maximum operating rate In operating cycles per hour Average consumption Inrush at 20 C and at Uc Sealed Heat dissipation Operating time Between coil energisation and at 20 C and at Uc opening of the N/C contacts closing of the N/O contacts

CA2 K a 12...690 0.8...1.15 Uc y 0.2 Uc 10 10 000 30 VA 4.5 VA 1.3 5...15 10...20 10...20 15...25 2

CA3 K c 12...250 0.8...1.15 Uc y 0.1 Uc 20 10 000 3W 3W 3 25...35 30...40 10 15 2

CA4 K c 12...120 0.7...1.3 Uc y 0.1 Uc 30 6000 1.8 W 1.8 W 1.8 25...35 30...40 10...20 15...25 2

W ms ms

Between coil de-energisation and opening of the N/O contacts ms ms closing of the N/C contacts ms Maximum immunity to microbreaks

References : pages 7/4 and 7/5

Dimensions : page 7/8

Schemes : page 7/9

7/2

Characteristics (continued)

Control relays
k control relays

Contact characteristics of control relays and instantaneous contact blocks


Number of auxiliary contacts On CAp K On LA1 K Rated operational voltage (Ue) Up to Rated insulation voltage (Ui) Conforming to BS 5424 Conforming to IEC 60947 Conforming to VDE 0110 group C Conforming to CSA C 22-2 n 14 Conventional thermal current For ambient temperature y 50 C (Ith) Frequency of the operational current Minimum switching capacity U min (DIN 19 240) I min Short-circuit protection Conforming to IEC 60947 and VDE 0660, gG fuse Rated making capacity Conforming to IEC 60947 I rms Short-time rating Permissible for 1s 500 ms 100 ms Insulation resistance Non-overlap distance CAp K and LA1 K: linked contacts conforming to INRS, BIA and CNA specifications V V V V V A Hz V mA A 4 2 or 4 for CA2 K and CA3 K, 2 for CA4 K 690 690 690 750 600 10 Up to 400 17 5 10

A A A A M mm

110 80 90 110 > 10 0.5 (see schemes page 7/9)

Operational power of contacts conforming to IEC 60947


a.c. supply, category AC-15 d.c. supply, category DC-13

Electrical durability (valid for up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making current (cos 0.7) = 10 times the power broken (cos 0.4)

Electrical durability (valid for up to 1200 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load.
V W W W W 24 120 55 15 720 48 80 38 11 600 110 60 30 9 400 220 440 600 52 28 8 300 51 26 7 230 50 25 6 200

V 1 million operating cycles 3 million operating cycles 10 million operating cycles Occasional making capacity VA VA VA VA

24

110/ 127 48 96 240 17 34 86 7 14 36 1000 2050 5000

48

220/ 380/ 440 600/ 230 400 690 440 800 880 1200 158 288 317 500 66 120 132 200 10 000 14 000 13 000 9000

Time constant in ms

1 Breaking limit of contacts valid for: b maximum of 50 operating cycles at 10 s intervals (power broken = making current x cos 0.7). 2 b b b Electrical durability of contacts for: 1 million operating cycles (2a) 3 million operating cycles (2b) 10 million operating cycles (2c).

Power broken in VA

Power broken in W

16 000 10 000 8000 6000 5000 4000 3000 2000 1000 800 600 500 400 300 200 1000 700 500 300 200 100 80 60 50 40 30 20 10 8 6 12 24 48 110 220 440 600 V

4 3

250

200 140

3 Breaking limit of contacts valid for: b maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4 Thermal limit

2a 2b 2c

2a 2b
24 48

100

100 80 60 40

50

2c
20 110 120 220 380 500 440 690 V

References : page 7/6

Dimensions : page 7/8

Schemes : page 7/9

7/3

References

Control relays
k control relays
For a.c. or d.c. control circuit

Control relays for a.c. control circuit


816892

b Mounting on 35 mm 7 rail or 4 screw fixing. b Screws in the open "ready-to-tighten" position.


Control circuit Consumption Auxiliary contacts Basic reference, to be completed by adding the voltage code (1) Weight

kg

Screw clamp connections


CA2 KN40pp 4.5 VA 4 3 2 1 2 CA2 KN40pp CA2 KN31pp CA2 KN22pp 0.180 0.180 0.180

816891

Spring terminal connections


4.5 VA 4 3 2 1 2 CA2 KN403pp CA2 KN313pp CA2 KN223pp 0.180 0.180 0.180

Faston connectors, 1 x 6.35 or 2 x 2.8


4.5 VA CA2 KN403pp 4 3 2 1 2 CA2 KN407pp CA2 KN317pp CA2 KN227pp 0.180 0.180 0.180

Solder pins for printed circuit boards


4.5 VA 4 3 2 1 2 CA2 KN405pp CA2 KN315pp CA2 KN225pp 0.210 0.210 0.210

Control relays for d.c. control circuit


b Mounting on 35 mm 7 rail or 4 screw fixing. b Screws in the open "ready-to-tighten" position.
819411

Screw clamp connections


3W 4 3 2 1 2 CA3 KN40pp CA3 KN31pp CA3 KN22pp 0.225 0.225 0.225

Spring terminal connections


3W CA3 KN407pp 4 3 2 1 2 CA3 KN403pp CA3 KN313pp CA3 KN223pp 0.225 0.225 0.225

Faston connectors, 1 x 6.35 or 2 x 2.8


3W 4 3 2 1 2 CA3 KN407pp CA3 KN317pp CA3 KN227pp 0.225 0.225 0.225

Solder pins for printed circuit boards


3W 4 3 2 1 2 CA3 KN405pp CA3 KN315pp CA3 KN225pp 0.255 0.255 0.255

(1) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office): Control relays CA2 K (0.8...1.15 Uc) (0.85...1.1 Uc) Volts a 12 20 24(2) 36 42 48 110 115 127 220/ 230 230/ 380/ 400 400/ 440 500 660/ 50/60 Hz 230 240 400 415 690 Code J7 Z7 B7 C7 D7 E7 F7 FE7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 Control relays CA3 K (0.8...1.15 Uc) Volts c 12 20 24(2) 36 48 60 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3. (2) When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (a code Z7, c code ZD) so as to compensate for the incurred voltage drop.

Characteristics : pages 7/2 and 7/3

Dimensions : page 7/8

Schemes : page 7/9

7/4

References

Control relays
k control relays
For d.c. control circuit

Low consumption control relays (d.c. control circuit)


b Mounting on 35 mm 7 rail or 4 screw fixing. b Screws in the open "ready-to-tighten" position.
816895

Control circuit Consumption

Auxiliary contacts

Basic reference, to be completed by adding the voltage code (1)

Weight

kg

Screw clamp connections


1.8 W CA4 KN40ppp 4 3 2 1 2 CA4 KN40pp CA4 KN31pp CA4 KN22pp 0.235 0.235 0.235

Spring terminal connections


1.8 W 4 3 2 1 2 CA4 KN403pp CA4 KN313pp CA4 KN223pp 0.235 0.235 0.235

Faston connectors, 1 x 6.35 or 2 x 2.8


1.8 W 4 3 2 1 2 CA4 KN407pp CA4 KN317pp CA4 KN227pp 0.235 0.235 0.235

Solder pins for printed circuit boards


1.8 W 4 3 2 1 2 CA4 KN405pp CA4 KN315pp CA4 KN225pp 0.265 0.265 0.265

(1) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office): Control relays CA4 K (Wide range coil: 0.7...1.3 Uc) Volts c 12 20 24 48 72 110 120 Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3

Characteristics : pages 7/2 and 7/3

Dimensions : page 7/8

Schemes : page 7/9

7/5

References

Control relays
k control relays
Instantaneous and time delay auxiliary contact blocks

Instantaneous auxiliary contact blocks


816899

Clip-on front mounting, 1 per control relay


Connection Composition Reference Weight

LA1 KN20

Screw clamp terminals

2 1 4 3 2 1 2 1 4 3 2 1 2 1 4 3 2 1

2 1 1 2 3 4 2 1 1 2 3 4 2 1 1 2 3 4

LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1

KN20 KN02 KN11 KN40 (1) KN31 (1) KN22 (1) KN13 (1) KN04 (1) KN203 KN023 KN113 KN403 (1) KN313 (1) KN223 (1) KN133 (1) KN043 (1) KN207 KN027 KN117 KN407 (1) KN317 (1) KN227 (1) KN137 (1) KN047 (1)

kg 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045

816900

Spring terminals

LA1 KN40

Faston connectors 1 x 6.35 or 2 x 2.8

Electronic time delay contact blocks


b b b b b
816899

Relay output with common point changeover contact, a or c 240 V, 2 A maximum Control voltage 0.85...1.1 Uc Maximum switching capacity 250 VA or 150 W Operating temperature - 10...+ 60 C Reset time: 1.5 s during the time delay period 0.5 s after the time delay period

Clip-on front mounting, 1 per control relay


Voltage Type Timing range Composition Reference Weight

7
LA2 KT2p V a or c 24...48 On-delay

s 1...30

LA2 KT2E

kg 0.040

a 110...240

On-delay

1...30

LA2 KT2U

0.040

Other versions

Electronic timers type RE4. Please consult your Regional Sales Office.
(1) Block of 4 contacts for use on CA2 K and CA3 K.

Characteristics : page 7/3

Dimensions : page 7/8

Schemes : page 7/9

7/6

References

Control relays
k control relays
Mounting and marking accessories

Suppressor modules incorporating LED indicator


Mounting and connection Clips onto front of relay with locating device. No tools required. Type For voltages a and c 12...24 V a and c 32...48 V a and c 50...129 V LA4 K ppp a and c 130...250 V Diode + Zener diode (2) c 12...24 V c 32...48 V RC (3) a 220...250 V Sold in lots of 5 Unit reference LA4 KE1B Weight kg 0.010

Varistor (1)

LA4 KE1E

0.010

LA4 KE1FC

0.010

LA4 KE1UG

0.010

LA4 KC1B

0.010

LA4 KC1E

0.010

LA4 KA1U

0.010

Mounting accessories
Description Application Sold in lots of Clip-on 1 Unit reference LA9 D973 Weight kg 0.025

Mounting plates

On 1 4 rail

On 2 4 rails

110/120 mm fixing centres

10

DX1 AP25

0.065

LA9 D973

Marking accessories
Description Application Sold in lots of 100 Unit reference LA9 D90 Weight kg 0.001

Marker holder

Clip-on fixing on front face

Clip-in markers

4 maximum per relay

Strips of 10 identical numbers 0 to 9 Strips of 10 identical capital letters A to Z

25

AB1 Rp (4)

0.002

25

AB1 Gp (4)

0.002

(1) Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time). (2) No overvoltage or oscillating frequency. Polarised component. Slight increase in drop-out time (1.1 to 1.5 times the normal time). (3) Protection by limiting the transient voltage to 3 Uc max. and limitation of the oscillating frequency. Slight increase in drop-out time (1.2 to 2 times the normal time). (4) Complete the reference by replacing the dot with the required character.

Dimensions : page 7/8

7/7

Dimensions, mounting

Control relays
7

k control relays

Control relays
CA2 K, CA3 K, CA4 K
On panel On printed circuit board

LA1 K
=

8,65

= = =

A1

58

58

50
45

50

35

57

35 45

A2

On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)

58

57

45

LA9 D973
On asymmetrical rail with clip-on mounting plates

DX1 AP25
On asymmetrical rail with clip-on mounting plates

DZ5 ME5

50

53

120

57

21

35 45

57

57

27

45

Electronic time delay contact blocks

LA2 KT
On control relay

LA2 KT 27

38

38

38

57

Suppressor modules
LA4 K
On control relay

25

LA4 K

22

57

Characteristics: pages 7/2 and 7/3

References: pages 7/4 to 7/7

Schemes: page 7/9

7/8

58

22

58

110

Schemes

Control relays
k control relays

Control relays
CA2 K, CA3 K, CA4 K
4 N/O
13/NO 23/NO 33/NO 43/NO

With integral suppression device


CA3 K
3 N/O + 1 N/C
13/NO 33/NO 43/NO 21/NC

CA4 K

2 N/O + 2 N/C
13/NO 43/NO 21/NC 31/NC

A1

A2

A1

A2

A2

14

24

34

44

A1

14

22

32

14

22

34

44

44

A2

+A1

+ A1

_ A2

Instantaneous auxiliary contact blocks LA1 K


For CA2 K, CA3 K, CA4 K
2 N/O LA1 KN20, LA1 KN207
53/NO 63/NO

For CA2 K, CA3 K


1 N/O + 1 N/C LA1 KN11, LA1 KN117
53/NO 61/NC

2 N/C LA1 KN02, LA1 KN027


51/NC 61/NC

4 N/O LA1 KN40, LA1 KN407


53/NO 63/NO 73/NO 83/NO

3 N/O + 1 N/C LA1 KN31, LA1 KN317


53/NO 73/NO 83/NO 61/NC

2 N/O + 2 N/C LA1 KN22, LA1 KN227


53/NO 83/NO 84 61/NC 62 71/NC 72

52

62

62

54

64

54

64

54

74

84

54

62

74

84

1 N/O + 3 N/C LA1 KN13, LA1 KN137


53/NO 61/NC 71/NC 81/NC

4 N/C LA1 KN04, LA1 KN047


51/NC 61/NC 71/NC 81/NC

52

62

72

54

62

72

Electronic time delay contact blocks LA2 KT


For CA2 K, CA3 K, CA4 K
1 C/O LA2 KT2
A1
16 18

Suppressor modules
LA4 KC LA4 KE

A2

15

82

82

54

Characteristics: pages 7/2 and 7/3

References: pages 7/4 to 7/7

Dimensions, mounting: page 7/8

7/9

Characteristics

Control relays

Mini-control relays types CAp SK and CA2 SKE

Environment
Rated insulation voltage (Ui) Conforming to IEC 60947, VDE 0110 gr C, BS 5424, CSA 22-2 n 14, UL 508 Conforming to standards Product certifications Protective treatment Conforming to IEC 60068 (DIN 50015) Degree of protection Conforming to VDE 0106 Ambient air temperature Storage around the device Operation Maximum operating altitude Without derating Operating position V 690

IEC 60947, NF C 63-110, VDE 0660, BS 5424 UL, CSA TC (Klimafest, Climateproof) Protection against direct finger contact - 50+ 70 - 20+ 50 2000 Horizontal axis

C C m

Vertical axis

Without derating Connection by connectors Solid cable Flexible cable without cable end Flexible cable with cable end Pozidriv n 1 head Conforming to standards EN 50005 and EN 50011 mm2 mm2 mm2 N.m Min. 1 x 1.5 or 2 x 1.5 1 x 0.5 or 2 x 0.35 1 x 0.35 or 2 x 0.35 0.8 Up to 4 contacts

Without derating Max. 1 x 6 or 2 x 4 1 x 6 or 2 x 2.5 1 x 6 or 2 x 1.5

Tightening torque Terminal referencing

Control circuit characteristics


Control relay type Rated control circuit voltage (Uc) Control voltage limits For operation (y 50 C) For drop-out Average consumption Inrush at 20 C and at Uc Sealed Heat dissipation Operating time Between coil energisation and at 20 C and at Uc opening of the N/C contacts closing of the N/O contacts Between coil de-energisation and opening of the N/O contacts closing of the N/C contacts Maximum operating rate In operating cycles per hour Mechanical durability at Uc 50/60 Hz coil in millions of operating cycles Standard c coil V CA2 SK a 24400 0.851.1 Uc u 0.20 Uc 16 VA 4.2 VA 1.4 816 714 68 810 1200 10 CA2 SKE CA3 SK c 1272 0.851.1 Uc u 0.10 Uc 2.2 W 2.2 W 2.2 1018 812 46 68 1200 10

W ms ms ms ms

23 VA 4.9 VA 1.5

References : pages 7/12 and 7/13

Dimensions : page 7/14

Schemes : page 7/15

7/10

Characteristics (continued)

Control relays

Mini-control relays types CAp SK and CA2 SKE

Auxiliary contact characteristics of mini-control relays and instantaneous contact blocks


Rated operational voltage (Ue) Rated insulation voltage (Ui) V V Up to 690 690 Conforming to IEC 96047, BS 5424, VDE 0110 group C, CSA C 22-2 n 14 Conventional rated For ambient temperature thermal current (Ith) y 55 C Frequency of the operational current Short-circuit protection Conforming to IEC 60947 and VDE 0660, gl fuse

A Hz A

10 Up to 400 10

Operational power of contacts conforming to IEC 60947


a.c. supply, category AC-15 Electrical durability (valid for up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making current (cos 0.7) = 10 times the power broken (cos 0.4). V 1 million operating cycles 3 million operating cycles 10 million operating cycles Occasional making capacity VA VA VA VA 110/ 127 48 96 240 17 34 86 7 14 36 1000 2050 5000 24 48 220/ 230 440 158 66 10000 380/ 400 800 288 120 14000 440 880 317 132 13 000 d.c. supply, category DC-13 Electrical durability (valid for up to 1200 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V W W W W 24 120 55 15 720 48 80 38 11 600 110 60 30 9 400 220 52 28 8 300 440 51 26 7 230

References : pages 7/12 and 7/13

Dimensions : page 7/14

Schemes : page 7/15

7/11

References

Control relays
Mini-control relays types CA2 SK and CA3 SK
Mini-control relay type CA2 SKE with alternating contacts

Mini-control relays
b Width of mini-control relays 27 mm. b Mounting on 35 mm 7 rail. b Connection by connectors.
Control circuit supply Auxiliary contacts Basic reference, to be completed by adding the voltage code (1) CA2 SK20pp CA2 SK11pp CA3 SK20pp CA3 SK11pp Weight
533664

CA2 SK20pp

a.c. supply

2 1

1 1

kg 0.132 0.132 0.132 0.132

d.c. supply

2 1

Mini-control relay with alternating contacts


This mini-control relay with alternating contacts (see function diagram page 7/15) makes it possible to automatically split the operating time between 2 circuits of a redundant system. By regularly energising the "safety circuits", this device makes it possible to ensure that they are operating correctly. b b b b b
CA2 SKE20pp
533665

Width of mini-control relay 45 mm. Fixing by 4 screws. Connection by connectors. Cannot be fitted with front-mounted auxiliary contact block. Cannot be fitted with coil suppressor module.
Auxiliary contacts Basic reference, to be completed by adding the voltage code (1) CA2 SKE20pp Weight

Control circuit supply

a.c. supply

kg 0.175

(1) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office): Mini-control relays CA2 SK and CA2 SKE Volts a 24 48 110 120 220 230 240 50/60 Hz Code B7 E7 F7 G7 M7 P7 U7 Mini-control relays CA3 SK Volts c 12 24 36 48 72 Code JD BD CD ED SD

380 Q7

400 V7

Characteristics: pages 7/10 and 7/11

Dimensions: page 7/14

Schemes: page 7/15

7/12

References

Control relays
Mini-control relays types CA2 SK and CA3 SK
Instantaneous auxiliary contacts and coil suppressor modules

Instantaneous auxiliary contact blocks


533666

Clip-on front mounting


For use on control relays Maximum number of blocks per contactor Composition Reference Weight

CA2 SK20 LA1 SK11

2 1

2 1

LA1 SK20 LA1 SK02 LA1 SK11

kg 0.022 0.022 0.022

Suppressor modules
533667

Connection without need for tools by clipping onto right-hand side of contactor
For use on control relays CA2 SK and CA3 SK LA4 SKp1p Type For voltages a and c 24 V48 V Sold in lots of 10 Unit reference LA4 SKE1E LA4 SKE1U LA4 SKC1U Weight kg 0.003 0.003 0.003

Varistor (1)

a and c 110 V250 V 10 Diode (2) c 24 V250 V 10

(1) Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time). (2) No overvoltage or oscillating frequency. Slight increase in drop-out time (1.1 to 1.5 times the normal time).

Characteristics: pages 7/10 and 7/11

Dimensions: page 7/14

Schemes: page 7/15

7/13

Dimensions, mounting

Control relays

Mini-control relays types CAp SK and CA2 SKE

Dimensions
Mini-control relays
CA2 SK and CA3 SK

55,5

27

84,5 55,5 27

56

LA4 SK

3,5 LA1 SK (1) 3,5

(1) Only on CA2 SK20.

Mounting
Mini-control relays
CA2 SK and CA3 SK On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)

55,5

27

Dimensions
CA2 SKE
68 45

56

7
4

Mounting
CA2 SKE
On panel On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)

58

68

45

48-50

34-35

Characteristics : pages 7/10 and 7/11

References : pages 7/12 and 7/13

Schemes : page 7/15

7/14

58

56

Schemes

Control relays

Mini-control relays types CAp SK and CA2 SKE

Schemes
CA2 SK20, CA3 SK20
2 N/O
13/NO 23/NO

CA2 SK11, CA3 SK11


1 N/O + 1 N/C
13/NO 14 A2 14 24 21/NO 22
Energised De-energised Close Open Close Open

A1

A2

14

24

CA2 SKE
2 N/O
13/NO 23/NO

A1

A2

A1

14

24

Instantaneous auxiliary contacts


2 N/O LA1 SK20
33/NO 43/NO

2 N/C LA1 SK02


31/NC 41/NC

A2 13 23

A1

CA2 SKE
Function diagram

1 N/O + 1 N/C LA1 SK11


33/NO 34 41/NC 42

34

44

32

42

Characteristics : pages 7/10 and 7/11

References : pages 7/12 and 7/13

Dimensions, mounting : page 7/14

7/15

Characteristics

TeSys control relays


TeSys d control relays

Control relay type

CAD a

CAD c

CAD low consumption 690

Environment
Rated insulation voltage (Ui) Conforming to IEC 60947-5-1 Overvoltage category III and degree of pollution 3 Conforming to UL, CSA Conforming to IEC 60947 Conforming to IEC 60536 and VDE 0106 V 690 690

V kV

600 6

600 6

600 6

Rated impulse withstand voltage (Uimp) Separation of electrical circuits Conforming to standards Product certifications Protective treatment Degree of protection Ambient air temperature around the device

Reinforced insulation up to 400 V IEC 60947-5-1, N-F C 63-140, VDE 0660, BS 4794, EN 60947-5 UL, CSA

Conforming to IEC 60068 Conforming to VDE 0106 Storage Operation, conforming to IEC 60255 (0.81.1 UC) For operation at Uc Without derating Without derating in the following positions C C C m

TH Front face protected against direct finger contact IP 2X - 60+ 80 - 5+ 60 - 40+ 70 3000 - 60+ 80 - 5+ 60 - 40+ 70 3000 Protection against direct finger contact - 60+ 80 - 5+ 60 - 40+ 70 3000

Maximum operating altitude Operating positions

30

180

30

90

90

180

1 80

Shock resistance (1) half sine wave for 11ms Vibration resistance (1) 5300 Hz Screw clamp connections

Control relay open Control relay closed Control relay open Control relay closed Flexible 1 conductor 2 without cable end Flexible 1 conductor with 2 cable end Solid conductor 1 without cable 2 end Tightening torque conductor conductors mm2 mm2 mm2 mm2 mm2 mm2 N.m

10 gn 15 gn 2 gn 4 gn 14 14

10 gn 15 gn 2 gn 4 gn 14 14

10 gn 15 gn 2 gn 4 gn 14 14

conductor conductors conductor conductors

14 12.5 14 14 1.7

14 12.5 14 14 1.7

14 12.5 14 14 1.7

Spring terminal connections

1 or 2 flexible or rigid conductors mm2 12.5 12.5 12.5 without cable end (1) In the least favourable direction, without change of contact state, with coil supplied at Uc.

References : pages 7/21 to 7/23

Dimensions : page 7/24

Schemes : page 7/25

7/16

Characteristics (continued)

TeSys control relays


TeSys d control relays

Control relay type

CAD a

CAD c

CAD low consumption c 572 0.71.25 Uc 0.10.25 Uc Inrush or sealed: 2.4 45

Control circuit characteristics


Rated control circuit voltage (Uc) Control voltage limits Operation With coil 50/60 Hz With standard coil, wide range Drop-out Average consumption at 20 C and at Uc a 50/60 Hz (at 50 Hz) VA V 12690 0.81.1 Uc at 50 Hz 0.851.1 Uc at 60 Hz 0.30.6 Uc Inrush: 70 sealed: 8 419 12440 0.71.25 Uc 0.10.25 Uc Inrush or sealed: 5.4 3545

With standard coil Operating time (at rated control circuit voltage and at 20 C)

Between coil energisation ms and - opening of the N/C contacts - closing of the N/O contacts ms Between coil de-energisation ms and - opening of the N/O contacts - closing of the N/C contacts ms

1222 412

5055 614

6070 1015

617 2 3 30

20 2 3 30 28

25 2 3 30 40

Short supply failure Maximum operating rate Mechanical durability In millions of operating cycles

Time constant L/R

Maximum duration without ms affecting hold-in of the device In operating cycles per second With coil 50/60 Hz (at 50 Hz) With standard coil c wide range ms

References : pages 7/21 to 7/23

Dimensions : page 7/24

Schemes : page 7/25

7/17

Characteristics (continued)

TeSys control relays


TeSys d control relays

Characteristics of instantaneous contacts incorporated in the control relay


Number of contacts Up to Rated operational voltage (Ue) Rated insulation voltage (Ui) Conforming to IEC 60947-5-1 Conforming to UL, CSA Conventional For ambient temperature 60 C thermal current (Ith) Frequency of the operational current Minimum switching capacity U min I min Short-circuit protection Rated making capacity Short-time rating Conforming to IEC 60947-5-1 Conforming to I rms IEC 60947-5-1 Permissible for 1s 500 ms 100 ms V V V A Hz V mA 5 690 690 600 10 25...400 17 5 gG fuse: 10 A a : 140, c : 250 A A A M Guaranteed between N/C and N/O contacts Philips head n 2 and 6 ms N.m 100 120 140 > 10 1.5 (on energisation and on de-energisation) 1.2 Linked contacts in association with auxiliary contacts LAD N The 3 N/O contacts and the 2 N/C contacts of CAD N32 are linked mechanically by one mobile contact carrier.

Insulation resistance Non-overlap time Tightening torque Non-overlap distance Linked contacts

Conforming to draft standard IEC 60947-4-5

References : pages 7/21 to 7/23

Dimensions : page 7/24

Schemes : page 7/25

7/18

Characteristics (continued)

TeSys control relays


TeSys d control relays

Rated operational power of contacts (conforming to IEC 60947-5-1)


a.c. supply, categories AC-14 and AC-15 Electrical durability (valid for up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making current (cos 0.7) = 10 times the power broken (cos 0.4).
V VA VA VA 24 60 16 4 48 120 32 8 115 280 80 20 230 560 160 40 400 960 280 70 440 1050 300 80 600 1440 420 100

1 million operating cycles 3 million operating cycles 10 million operating cycles


Millions of operating cycles

1 8 7 6 5 4 3 2

1 0,8 0,7 0,6 0,5 0,4 0,3 0,2

0,1 0,1 0,2 0,3 0,4 0,5 0,6 0,8 1 0,7 0,9 2 3 6 8 10 5 7 9 Current broken in A 4

d.c. supply, category DC-13 Electrical durability (valid for up to 1200 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the power.
V W W W 24 120 70 25 48 90 50 18 125 75 38 14 250 68 33 12 440 61 28 10

1 million operating cycles 3 million operating cycles 10 million operating cycles


Millions of operating cycles

1 8 7 6 5 4 3 2 250 V

24 V 48 V 125 V

1 0,8 0,7 0,6 0,5 0,4 0,3 0,2

440 V

0,1 0,1 0,2 0,3 0,4 0,5 0,6 0,8 1 0,7 0,9 2 3 4 6 8 10 5 7 9 Current broken in A

References : pages 7/21 to 7/23

Dimensions : page 7/24

Schemes : page 7/25

7/19

References

TeSys control relays


TeSys d control relays and add-on blocks

See page opposite for mounting possibilities according to control relay type and rating

7/20

References

TeSys control relays


TeSys d control relays and add-on blocks
Control circuit: a.c., d.c. or low consumption

Control relays for connection by screw clamp terminals


Type Number of contacts Composition Basic reference, to be completed by adding the control voltage code (1) Standard voltages a Instantaneous 5 5 3 CAD 50 pp 2 CAD 50pp (3) CAD 32pp (3) B7 B7 P7 P7 c BD BD LC (2) BL BL kg 0.580 0.580 Weight

Control relays for connection by spring terminals


Instantaneous 5 5 3 2 CAD 503pp CAD 323pp B7 B7 P7 P7 BD BD BL BL 0.580 0.580

Instantaneous auxiliary contact blocks for connection by screw clamp terminals


For use in normal operating environments
Number of contacts Maximum number per relay Clip-on mounting front side 1 1 1 1 1 on LH side 1 on LH side 1 on LH side Composition Reference Weight

CAD 32 pp

kg 2 1 1 2 2 2 1 4 3 2 1 1 2 2 2 3 4 1 2 LAD LAD LAD LAD LAD LAD LAD LAD LAD LAD LAD LAD N11 8N11 (6) N20 8N20 (6) N02 8N02 (6) N22 N13 N40 N04 N31 C22 0.030 0.030 0.030 0.030 0.030 0.030 0.050 0.050 0.050 0.050 0.050 0.050

4 (4)

4 (4) 1 Including 1 N/O and 1 N/C make before break. CAD 503pp Number of contacts Maximum number per relay Front mounting 1 Composition

With dust and damp protected contacts, for use in particularly harsh industrial environments
Reference Weight

4 (4)

protected (5) 2 2 2 2 2 2

kg 2 1 1 LA1 DX20 LA1 DX02 LA1 DY20 LA1 DZ40 LA1 DZ31 0.040 0.040 0.040 0.050 0.050

CAD 323 pp

Instantaneous auxiliary contact blocks for connection by spring terminals


This type of connection is not possible for contact blocks LAD 8 and blocks with dust and damp protected contacts. For all other instantaneous auxiliary contact blocks, add the digit 3 to the end of the references selected above. Example: LAD N11 becomes LAD N113. (1) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). a.c. supply Volts a 24 42 48 110 115 220 230 240 380 400 415 440 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 d.c. supply (coils with integral suppression device fitted as standard) Volts c 12 24 36 48 60 72 110 125 220 250 440 U from 0.7 to 1.25 Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption (coils with integral suppression device fitted as standard) Volts c 5 12 20 24 48 110 220 250 Code AL JL ZL BL EL FL ML UL (2) LC: low consumption. (3) To order control relays with connection by lugs, add the digit 6 to the end of the selected reference. Example: CAD50pp becomes CAD506 pp. (4) Blocks with 4 auxiliary contacts cannot be used on low consumption control relays. (5) Product fitted with 4 earth screen continuity terminals. (6) These contact blocks cannot be used on low consumption control relays. Characteristics : pages 7/16 and 7/17 Dimensions : page 7/24 Schemes : page 7/25

7/21

References

TeSys control relays


TeSys d control relays
Add-on blocks

Time delay auxiliary contact blocks for connection by screw clamp terminals (1)
Number and type of contacts 1 N/C and 1 N/O Maximum number per relay Front mounting 1 Time delay Type On-delay Range 0.13 s (2) 0.130 s 10180 s 130 s (3) 0.13 s (2) 0.130 s 10180 s Reference Weight kg LAD LAD LAD LAD LAD LAD LAD T0 T2 T4 S2 R0 R2 R4 0.060 0.060 0.060 0.060 0.060 0.060 0.060

Off-delay (Sealing cover: see page 5/73) LAD T

Time delay auxiliary contact blocks for connection by spring terminals


Add the digit 3 to the references selected above. Example: LAD T0 becomes LAD T03.

Mechanical latch blocks (4)


Unlatching control Manual or electric Maximum number per relay Front mounting 1 Basic reference to be completed (5) LAD 6K10p Weight kg 0.070

Suppressor modules
These modules clip onto the top of the control relay and the electrical connection is instantly made. Fitting of an input module is still possible. LAD 6K10

RC circuits (Resistor-Capacitor)
b Effective protection for circuits highly sensitive to "high frequency" interference. b Voltage limited to 3 Uc maximum and oscillating frequency limited to 400Hz maximum. b Slight time delay on drop-out (1.2 to 2 times the normal time). For Operational Reference mounting on voltage CAD a a 2448 V LAD 4RCE a 110240 V LAD 4RCU

Weight kg 0.012 0.012

Varistors (peak limiting)


b Protection provided by limiting the transient voltage value to 2Uc maximum. b Maximum reduction of transient voltage peaks. b Slight time delay on drop-out (1.1 to 1.5 times the normal time). CAD a a 2448 V LAD 4VE a 50127 V LAD 4VG a 110250 V LAD 4VU

0.012 0.012 0.012

Freewheel diode
LAD 4pp b No overvoltage or oscillating frequency. b Increase in drop-out time (6 to 10 times the normal time). b Polarised component. CAD c c 24250 V

LAD 4DDL

0.012

Bidirectional peak limiting diode


b Protection provided by limiting the transient overvoltage value to 2Uc maximum. b Maximum reduction of transient voltage peaks. CAD a a 24 V LAD 4TB a 72 V LAD 4TS CAD c c 24 V LAD 4TBDL c 72 V LAD 4TSDL c 125 V LAD 4TGDL c 250 V LAD 4TUDL c 600 V LAD 4TXDL

0.012 0.012 0.012 0.012 0.012 0.012 0.012

LAD 4DDL ou LAD 4T pDL

(1) These contact blocks cannot be used on low consumption control relays. (2) With extended scale from 0.1 to 0.6 s. (3) With switching time of 40 ms 15 ms between opening of the N/C contact and closing of the N/O contact. (4) Power should not be simultaneously applied or maintained to the mechanical latching block of the CAD N. The duration of the control signal to the mechanical latching block and the CAD N should be u 100 ms. (5) Standard control circuit voltages (for other voltages, please consult your Regional Sales Office): Volts a and c 24 32/36 42/48 60/72 100 110/127 220/240 256/277 380/415 Code B C E EN K F M U Q (6) CAD pp d.c. and low consumption control relays are fitted with a built-in bi-directional peak limiting diode suppressor as standard. On control relays produced after 15th July 2004, this diode is removable. It can therefore be replaced by the user (see references LAD 4T ppp above). It can also be replaced by a freewheel diode LAD 4DDL . If a d.c. or low consumption control replay is used without suppression, the standard suppressor should be replaced with a blanking plug LAD 9DL.

Characteristics : pages 7/16 and 7/17

Illustrations: page 7/20

Dimensions : page 7/24

Schemes : page 7/25

7/22

References

TeSys control relays


TeSys d control relays
Accessories and spare parts

Accessories (to be ordered separately)


Description For marking Sheet of 64 blank legends, self-adhesive, 8 x 33 mm For mounting on CAD, LAD (4 contacts) Sold in lots of 10 Unit reference Weight kg 0.020 0.020 0.200

LAD 21 LAD 22

Sheet of 112 blank legends, LAD (2 contacts), self-adhesive, 8 x 12 mm LAD T Strips of blank, self-adhesive All products legends for printing by plotter (4 sets of 5 strips) SIS Label labelling Multi-language version: software for legends LAD 21 English, French, German, and LAD 22, supplied on Italian, Spanish CD-Rom Legend holder, snap-in, LC1 D09...38 8 x 18 mm LC1DT20...40 LADN (4 contacts) LAD T, LAD R For protection Sealing cover LAD T, LAD R Safety cover preventing CAD access to the moving contact carrier 35

LAD 24

XBY 2U

0.100

SIS-L

s uette are ion d'tiq ette softw di crat oftware etiquetas etich lling ione Labe iel de ngss crear Logic hriftu para la creaz Besc are per Softw are Softw

abel

Gerin n Merlin Modico D canique Square Teleme

100

LAD 90

0.001

XBY 2U

1 1

LA9 D901 LAD 9ET1

0.005 0.004

Spare parts: coils


LA9 D901 Specifications b Average consumption at 20 C: - inrush (cos = 0.75) 50/60 Hz: 70 VA at 50 Hz, - sealed (cos = 0.3) 50/60 Hz: 8 VA at 60 Hz, b Operating range ( < 60 C): 0.85 to 1.1 Uc Control circuit Average resistance Inductance of Reference (1) voltage Uc at 20 C 10 % closed circuit 50/60 Hz V V H 12 6.3 0.26 LXD 1J7 21 (2) 5.6 0.24 LXD 1Z7 24 6.19 0.26 LXD 1B7 32 12.3 0.48 LXD 1C7 36 LXD 1CC7 42 19.15 0.77 LXD 1D7 48 25 1 LXD 1E7 60 LXD 1EE7 100 LXD 1K7 110 130 5.5 LXD 1F7 115 LXD 1FE7 120 159 6.7 LXD 1G7 127 192.5 7.5 LXD 1FC7 200 LXD 1L7 208 417 16 LXD 1LE7 220/230 539 22 LXD 1M7 (3) 230 595 21 LXD 1P7 230/240 645 25 LXD 1U7 (4) 277 781 30 LXD 1W7 380/400 1580 60 LXD 1Q7 400 1810 64 LXD 1V7 415 1938 74 LXD 1N7 440 2242 79 LXD 1R7 480 2300 85 LXD 1T7 2499 LXD 1S7 500 575 3294 LXD 1SC7 600 3600 135 LXD 1X7 690 5600 190 LXD 1Y7 (1) The last 2 digits in the reference represent the voltage code. (2) Voltage for special coils fitted in control relays with serial timer module with 24 V supply. (3) This coil can be used on 240 V at 60 Hz. (4) This coil can be used on 230/240 V at 50 Hz and on 240 V only at 60 Hz.

Weight kg 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070

LAD 9ET1

LXD 1

Characteristics : pages 7/16 and 7/17

Dimensions : page 7/24

Schemes : page 7/25

7/23

Dimensions, mounting

TeSys control relays


7

TeSys d control relays and add-on blocks

Dimensions
CAD a CAD c or LC (low consumption)

c c1 c2 c3

12,5 (LAD 8)

45 c1 c2 c3

45

CAD
b c

32 50
77 84 86 117 129 137 141

323 503
99 84 86 117 129 137 141

CAD
b c

32 50
77 93 95 126 138 146 150

323 503
99 93 95 126 138 146 150

without cover or add-on blocks with cover, without add-on blocks c1 with LAD N or C (2 or 4 contacts) c2 with LAD 6K10 c3 with LAD T, R, S with LAD T, R, S and sealing cover

without cover or add-on blocks with cover, without add-on blocks c1 with LAD N or C (2 or 4 contacts) c2 with LAD 6K10

c3 with LAD T, R, S with LAD T, R, S and sealing cover

Mounting
CAD
Panel mounted Mounted on rail AM1 DP200 or DE200

(1)
=

= = 78

60/70

45

CAD a

CAD c or LC
95 c (AM1 DP200) (2) c (AM1 DP200) (2) (2) With cover

35

CAD a
88 96

CAD c or LC
97 105

with cover

86

(1) 2 elongated holes 4.5 x 9 Mounted on plate AM1 P

AF1 EA4

35

CAD a
c with cover 86

CAD c or LC
95

Characteristics : pages 7/16 to 7/19

Illustrations: page 7/20

60/70

References : pages 7/21 to 7/23

Schemes : page 7/25

7/24

Schemes

TeSys control relays


TeSys d control relays and add-on blocks

Schemes
Instantaneous auxiliary contacts
5 N/O CAD 50
13/NO 23/NO 33/NO 43/NO 03/NO

3 N/O + 2 N/C CAD 32


13/NO 43/NO 44 03/NO 04 21/NC 22 31/NC 32

A1

A2

A1

A2

14

24

34

44

Instantaneous auxiliary contact blocks


1 N/O + 1 N/C LAD N11
53/NO 61/NC

04

14

LAD 8N11 (1)


161/NC (172) 153/NO (184)

2 N/O LAD N20


53/NO 63/NO

LAD 8N20 (1)


153/NO (184) 163/NC (174)

2 N/C LAD 8N02


151/NC (182) 161/NC (172)

LAD N02
51/NC 52 83/NO 53/NO 61/NC 62

54

62

54

64

152 (181)
53/NO

154 (183)

162 (171)

(1) The figures in brackets are for the device mounted on the RH side of the control relay. 2 N/O + 2F N/C LAD N22
53/NO 83/NO 61/NC 71/NC

1 N/O + 3 N/C LAD N13


53/NO 61/NC 71/NC 81/NC

4 N/O LAD N40


53/NO 63/NO 73/NO 83/NO

4 N/C LAD N04


71/NC 51/NC 61/NC 81/NC

154 (183)

164 (173)

3 N/O + 1 N/C LAD N31


73/NO 74 83/NO 84 61/NC 62

54

62

72

84

54

64

74

84

62

72

82

72

52

2 N/O + 2 N/C including 1 N/O + 1 N/C make before break LAD C22
53/NO 87/NO 61/NC 75/NC

54

With dust and damp protected contacts 2 N/O protected 2 N/C protected

2 N/O protected (2)

62

82

54

2 N/O protected + 2 N/O non protected LA1 DZ40


53/NO 63/NO 73/NO

162 (171)

LA1 DX20
53/NO 63/NO

LA1 DX02
51/NC 61/NC

LA1 DY20
53/NO 63/NO

2 N/O protected + 1 N/O + 1 N/C non protected LA1 DZ31


73/NO 74 61/NC 83/NO 84

54

62

76

88

64

52

62

54

64

54

74

84

54

(2) Product fitted with 4 earth screen continuity terminals.

64

54

62

7
Mechanical latch blocks
LAD 6K10
A1
65/NC

Time delay auxiliary contact blocks


On-delay 1 N/O + 1 N/C LAD T
67/NO 55/NC

LAD S
67/NO 55/NC

Off-delay 1 N/O + 1 N/C LAD R


57/NO

56

68

56

68

58

66

A2

Characteristics : pages 7/16 to 7/19

Illustrations: page 7/20

References : pages 7/21 to 7/23

E2

E1

Schemes : page 7/25

7/25

Selection guide

Zelio Time
Timing relays

Applications

These timing relays enable simple automation cycles to be set up using wired logic. They can also be used to complement the functions of PLCs. Solid state Timing relays with solid state output reduce the amount of wiring required (wired in series). The durability of these timing relays is independent of the number of operating cycles. Relay Relay outputs provide complete isolation between the supply and outut circuits. It is possible to have several output circuits.

Output

Type

Modular

Industrial

Modular

Industrial

Timing ranges

7 ranges: 1 or 2 ranges, 1 s, 10 s, 1 min, 10 min, depending on model: 1 h, 10 h, 100 h 10 s, 30 s, 300 s, 60 min

Depending on model: 6 ranges: 1 s, 10 s, 1 min, 10 min, 1 h, 10 h 7 ranges: 1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

Depending on model : 4 ranges: 0.6 s, 2.5 s, 20 s, 160 s 7 ranges: 1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h 7 ranges: 1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 10 min 10 ranges: 1 s, 3 s, 10 s, 30 s, 100 s, 300 s, 30 min, 300 min, 30 h, 300 h

Relay type

RE11 Lp pp

RE9

RE11 Rp pp

RE 88 865 ppp RE7

Pages

Please consult our catalogue Automation and relay functions.

7/26

These timing relays enable simple automation cycles to be set up using wired logic. They can also be used to complement the functions of PLCs. Relay Relay outputs provide complete isolation between the supply and output circuits. It is possible to have several output circuits.

Optimum

Plug-in Universal Miniature 7 ranges: 0,1 s...1 s 1 s...10 s 0,1 min...1 min 1 min...10 min 0,1 h...1 h 1 h...10 h 10 h...100 h

Panel-mounted Analogue 14 ranges: 1,2 s, 3 s, 12 s, 30 s, 120 s, 300 s, 12 min, 30 min, 120 min, 300 min, 12 h, 30 h, 120 h, 300 h Digital Depending on model: 7 range : 99.99 s, 999.99 s, 99 min 59 s, 99.99 min, 999.9 min, 99 h 59 min, 999.9 h 11 ranges: 99.99 s, 999.99 s, 9999 s, 99 min 59 s, 99.99 min, 999.9 min, 9999 min, 99 h 59 min, 99,99 h, 999.9 h, 9999 h

1 range, depending on model: 0.5 s, 3 s, 10 s, 30 s, 300 s, 30 min

7 ranges: 1 s, 10 s, 1 min, 10 min, 1 h, 10 h, 100 h

RE8

RE 88 867 ppp

RE XLpTMpp

RE 48A ppp

RE 88 857 ppp

Please consult our catalogue Automation and relay functions.

7/27

Selection guide

Zelio Control
Measurement and control relays

Applications

Supply control relays 3-phase 3-phase + neutral

Functions

Control : - rotational direction, - presence of phases, - undervoltage, - overvoltage and undervoltage - asymmetry of phases

Control : - overvoltage and undervoltage - presence of neutral,

Relay output Width

1 or 2 C/O contacts 22.5 mm 45 mm

2 C/O contacts 45 mm

Relay type

RM4 Tppp RM 84 873 004 RM 84 873 299 RM 84 873 5pp

RM 84 873 01p RM 84 873 201 RM 84 873 3pp

RM 84 873 211

Pages

Please consult our catalogue Automation and relay functions.

7/28

Voltage measurement relays

Current measurement relays

Control : - overvoltage a 50 mV...5 V a 1..0.100 V a 30..0.500 V

Control : - overvoltage or undervoltage a 50 mV...5 V a 0.2...60 V a 1...100 V a 15...600 V a 30...500 V a 0.2...60 V a 15...600 V a orc 20...80 V a orc 65...260 V 1 or 2 C/O contacts 1 C/O contact 45 mm

Control : Control : - overvoltage and - overcurrent undervoltage 1...20 A with built-in TI

3 mA...1 A

Control : overcurrent and undercurrent 3 mA...1 A 0.3...15 A 2...500 mA 2...500 mA 0.1...10 A 0.1...10 A 10...100 A with built-in TI

1 C/O contact 22.5 mm

2 C/O contacts 22.5 mm

1 C/O contact 17.5 mm 22.5 mm

1 or 2 C/O contacts 45 mm

RM4 UA0pp RM4 UA3p RM 84 872 3pp RM4 UB3p RM 84 871 102 RM4 JA01p RM4 JA31pp RM4 JA32pp RM 84 872 0pp RM 84 871 0pp RM 84 871 3pp

Please consult our catalogue Automation and relay functions.

7/29

Selection guide
(continued)
7

Zelio Control
Measurement and control relays

Applications

Liquid level control relays

Functions

Control : - empty

Control : - empty or fill

Relay output Width

1 C/O contact 22.5 mm Plug-in 8 or 11-pin

1 or 2 C/O contacts 22.5 mm

Relay type

RM 84 870 1p1

RM 84 870 30p RM 84 870 807

RM4 Lpppp RM 84 870 00p

Pages

Please consult our catalogue Automation and relay functions.

7/30

Liquid level control relays

Motor control relays

Control : - empty or fill with alarm

Control : - empty and fill

Control : - underspeed

Control : - overload and underload (cos ) 2 C/O contacts

2 C/O contacts 45 mm

1 C/O contact

1 C/O contact Plug-in 8 or 11-pin

1 C/O contact 45 mm

RM 84 870 50p

RM 84 870 604

RM 84 870 40p RM 84 870 808

RM 84 874 30p

RM 84 873 40p

Please consult our catalogue Automation and relay functions.