MCCB
MCCB
MCCB
TemBreak Plus
Ics = 50KA and 85kA
New
TERASAKI
Innovators in Protection Technology
In the ever advancing high level information age Tembreak Plus MCCBs are the answers for all switching and protection applications in power distribution and industrial control.
P ower breaking capacities L ong lasting reliability U nique contact structure S electivity enhanced switchgear
Power Breaker Series : Ics = 50KA
Type No. of Poles Ampere Frame Rated Current (Amps) XH125PJ 3, 4 125 20, 32, 50, 63, 100, 125 XH160PJ 3, 4 160 160 XH250PJ 3, 4 250 160, 250 XH400PJ 3, 4 400 250, 400 XH400PE 3, 4 400 250, 400 XH630PJ 3, 4 630 400, 630 XH630PE 3, 4 630 630 XH800PJ 3, 4 800 800 XH800PE 3, 4 800 800
Rated AC Breaking Capacity IEC 60947-2 415V Icu/Ics KA 400V Thermal Magnetic Microprocessor Dimensions 4P Dimensions 3P Reference MCCB for accessories 120x155x86 90x155x86 XH125NJ 140x165x103 105x165x103 XH250NJ 50/50 50/50 50/50 50/50 65/50 65/50 65/50 65/50 65/50 65/50 85/50 100/50 65/50 65/50 85/50 100/50 65/50 65/50
185x260x103 185x260x103 185x260x103 280x273x103 280x273x103 280x273x103 280x273x103 140x260x103 140x260x103 140x260x103 210x273x103 210x273x103 210x273x103 210x273x103 XS400NJ XS400NJ XH400NE XS630NJ XH630NE XS800NJ XH800NE
I (ON)
I (ON)
TRIP
TRIP
O (OFF)
O (OFF)
Magnetic Setting
From 5 to 10 times In 5 main points of calibration are 5, 6, 7.1, 8.5 & 10. (For all MCCBs including and above 400A rating along with XH 250PJ)
Applicable MCCBs
Frame XH250PE XS400NE XS630NE XS800NE XS1250NE XS1600NE XH400PE XH630PE XH800PE Setting Dial Base Current Setting LTD Pick up LTD Setting STD Pick up STD Setting INST Pick up I0 I1 T1 I2 T2 I3 Rating 250 400 630 800 1250 1600 400 630 800 Poles 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 Breaking capacity Icu Ics At 415 VAC 50 50 50 65 85 65 65 65 25 25 25 49 64 50 50 50
0.8
1.0 30
I1
T1
L.T.D
Time
65
33
5 2 10
I2
1.0
S.T.D
T2
INST.
0.3 3 600% of I1 12
I
Available Adjustments 0.63 - 0.8 - 1.0 x I0 0.8 - 0.85 - 0.9 - 0.95 - 1.0 x I0 5 - 10 - 15 - 20 - 25 - 30 (at I1 x 600%) 2 - 4 - 6 - 8 - 10 x I0 0.1 - 0.15 - 0.2 - 0.25 - 0.3 3 - 12 x I0 (continuously adjustable) Amps Amps Secs Amps Secs Amps
T=500 Sec
RESET
TRIP INDICATORS
l1 T1 lG TG l2 T2
LONG TIME CURR. 0.85 0.95 SETTING 0.8 1.0 l1 l3 x l0 l RATED CUR. (A) 15 BASE CUR. 20 TIME 10 lc 1250 A SETTING 5 30 0.63 0.8 1.0 x ln PICK UP
T1
0.9
x l0 0.2
10 3 l3 0.25 0.3
x l0
12 0.1 lG x ln
2
SHORT TIME l t
0.2
0.3
0.4
SEC at 6 x I1
OFF ON T2 SEC at 10 x IO
Legend LTD* STD* INST* l2t RAMP* Pick-up LED* Test Port* PTA GFT LEDS HI-INST
* Standard for all Microprocessor MCCBs
Application Long Time Delay Short Time Delay Instantaneous : : : : : : Pre-Trip Alarm Ground Fault Trip Light Emitting Diodes High Instantaneous : : : : Overload protection , True R.M.S. Short circuit protection and selectivity Short circuit protection, fast acting Provides easier grading with downstrams fuses Lights on LTD overload, flashes on PTA pick-up Facility for TNS-1 OCR checker for calibration checking Useful for loadshedding application Protection against ground application Indication of fault for faster diagnosis High inrush applications, increased selectivity
TemBreak
Series Frame No. of Poles ECONOMY 'XE' 2, 3 3 3, 4
Series
STANDARD 'XS' HIGH FAULT 'XH'
XE100NS XE225NC XS125NJ XS250NJ XS250PJ XS400CJ XS400NJ XS630CJ XS630NJ XS800NJ XH125NJ XH250NJ 3, 4 160,250 3, 4 160,250 3, 4 400 3, 4 400 3, 4 630 3, 4 630 3, 4 800 3, 4 20,32,50 63,100,125 3, 4 160,250
Ratings (In) Breaking Capacity (Icu) KA at 415 VAC as per IEC 60947-2 Calibration Temperature Thermal Setting Magnetic Setting Rated Insulation Voltage (Ui) Rated Impulse withstand voltage Vimp (KV)
30,40,50
175
63,100,125
60,75,100 200,225
10
15
25
25
35
35
50
35
50
50
50
50
400C
450C
450C
450C
450C
450C
450C
450C
450C
450C
450C
450C
Fixed
Fixed Fixed
Adjustable (63% to 100% of In) Adjustable (5 to 10 Times In) 690 690 690 690 690 690 690 690 Fixed 690
660
690
690
Features
Conforms to IEC60947-2 / IS 13947-2 Widest range from 10A to 4000A to suit all applications Line Load Interchangeability Current Limiting design Compact sizes Approved from : American Bureau of shipping, USA : Lloyd's register, UK : Germanischer Lloyd, Germany : ASTA, UK Draw out type Anti Corrosive application DC Application Genset Protection Mining Series (1100 VAC) Disconnector Series
Plug in MCCB
4 Pole MCCB
ACCESSORIES
Internal Accessories
Shunt Trip (SHT) Standard Voltages : (with builtin Anti burning switch) 200-480 V AC 100-115 V AC Under Voltage Trip (UVT) Standard Voltage : 350-450 V AC
1 Change over
External Accessories
Motor Operator
Extended Terminals
Interpole barriers
Dimensions(mm)
Upto 400 A Frame
3P H L 4P H L ASL Y N Mounting hole
FRAMES
H H1 W W1 W W1 W2 d D D1 Y
}
XE100NS XE225NC XS125NJ/XH125NJ/XH125PJ XS250NJ XS250PJ/XH250NJ XH250PE/XE400NS/XS400CJ/XS 400NJ XS400NE/XH400NE/XH250PJ/ XH400PE/XH400PJ 130 160 155 165 165 260 260 110 135 134 144 144 228 228 3 Pole 75 50 105 70 90 60 105 70 105 70 140 90 140 90
}
4 Pole - - 5 87 - - 7 83 120 90 30 4 104 140 105 35 4 107 140 105 35 4 124 185 135 45 7.5 145 185 135 45 7.5 145 68 60 86 86 103 103 103 64 92 102 102 102 102 102
H1
ASL
H1 H
W1 W
W2 W1 W
D1 D
BREAKER TYPE
XE600NS
28 14 M8 Mounting screw A B (Neutral: N) 103 145
A
8 8 8 10 10
B
34 34 36 35 36
N
36 36 36 36
ASL
ASL
XS630CJ, XS630NJ, XH630PJ XS630NE, XH630NE, XH630PE XS800NJ, XH800PS XS800NE, XH800NE, XH800PE
40 140 240
7.5 80.5
4P H L 80
31 8
140
ASL 8 25 32 170 80
200
ASL
28 18
45 140 210
17 80
14 120 171
29
M8 Mounting screw
* For dimensions of 1600A, 2000A & 2500A Frames, contact our nearest Sales Office.
PD/MCCB/3000/AUG '04
RP/5000/Jan '08