ANT-5 Datasheet10 en
ANT-5 Datasheet10 en
ANT-5 Datasheet10 en
In addition, operators must be able to manage the conflicting demands of technicians, who need the proper equipment and training to do their jobs, and executives, who are keeping close control on capital expenses and operating costs.
Highlights Smallest and lightest test solution for interfaces from 1.544 Mbps up to 2.5 Gbps at 2.2 kg Optical testing at dual wavelengths at STM-1/OC-3, STM-4/OC-12, and STM-16/OC-48 Electrical testing at DS1/E1/E3/DS3/E4 and STM-1/OC-3 interfaces Full analysis of concatenated mappings with SDH/SONET signals VC-4-4C/OC-12C, VC-4-16C/OC-48C In-depth PDH analysis with Sabit generation and flexible MUX/DEMUX test configuration Optical power measurement capability for easy detection of physical layer integrity ATM analysis for service verification of ATM and 3G/UMTS networks testing new ATM services carried over PDH, SDH/SONET ECL NRZ port enables nonintrusive direct monitoring of optical networks
STM-16
AUG 16
AU-4-16c
VC-4-16c
C-4-16c
STM-4
AUG 4
AU-4-4c
VC-4-4c
C-4-4c
STM-1
AUG 1
AU-4
VC-4
C-4
TU-3
VC-3 C-3
DS3: 44 736 kbps E3: 34 368 kbps
TU-12
VC-12
C-12
TU-11
VC-11
C-11
OC-3/-12/-48
OC-N
STS-N
STS-48c
STS-48c SPE
STS-12c
STS-12c SPE
STS-3c
STS-3c SPE
STS-1
STS-1 SPE
VT-Group
VT2 VT1.5
Technical specifications
G.703 transmitters BNC 75 unbalanced outputs Bit rates and line codes 2048, 34368 Kbps 44736 Kbps(1) 139264, 155520 Kbps RJ48 120 balanced output Bit rate and line codes 2048 Kbps G.703 receivers BNC 75 unbalanced inputs Bit rates and line codes 2048, 34368 Kbps 44736 Kbps(1) 139264, 155520 Kbps RJ48 120 balanced input Bit rate and line codes 2048 Kbps Clock recovery - Pulling range as G.703 Selectable input gain 155520 Kbps 2048, 34368, 44736, 139264 Kbps T1 interface Connectors Input impedance Bit rate Line Code E1 Hi-Z input A high input impedance setting for the E1 75, E1 120 and T1 100 ports enables these signals to be monitored without a PMP. Bantam 100 1544 Kbps AMI, B8ZS
G.957 optical transmitter and receiver (options) Class 1 laser product Connectors FC-PC connectors Transmitter wavelengths Single wavelength 1310 nm Dual wavelengths 1310 nm and 1550 nm Line bit rates 155.52 Mbps 622.08 Mbps 2488.32 Mbps Line code Optical transmitter specifications Optical Option HDB3 B3ZS CMI BN4565/00.01 BN4565/00.03 BN4565/91.13 BN4565/00.14 BN4565/91.15 BN4565/91.16 Line rate STM1 STM1 STM1/4 STM1/4 STM1/4 STM1/4/16 Wavelength 1310SR 1310SR/1550LR 1310SR 1310SR/1550LR 1310LR/1550LR 1310LR/1550 LR Tx Output power @ 1310nm -8dBm to -15dBm -8dBm to -15dBm -8dBm to -15dBm -8dBm to -15dBm +2dBm to -4dBm +3dBm to -3dBm Tx Output power @ 1550nm +2dBm to -4dBm +2dBm to -4dBm +2dBm to -4dBm +3dBm to -3dBm
HDB3
scrambled NRZ
HDB3
Optical receiver specifications Optical Option 20 dB 26 dB BN4565/00.01 BN4565/00.03 BN4565/91.13 BN4565/00.14 BN4565/91.15 BN4565/91.16 Line rate STM1 STM1 STM1/4 STM1/4 STM1/4 STM1/4/16 Wavelength 1310SR 1310SR/1550LR 1310SR 1310SR/1550LR 1310LR/1550LR 1310LR/1550 LR Rx Dynamic range Rx Optical overload @ 1100 to 1600nm -8dBm to -28dBm N/A -8dBm to -28dBm N/A -8dBm to -28dBm N/A -8dBm to -28dBm N/A -8dBm to -28dBm N/A -8dBm to -28dBm -6dBm
Optical power measurement Measurement of the received optical signal level Resolution: 155/622/2488 Mbps electrical interface For connecting ANT-5 to STM-1/OC03, STM-4/OC12 and STM-16/OC-48 monitor points Line code: Input voltage (peak to peak) Coaxial input Connector/Impedance Transmit clock synchronization Internal stability Tx Bit Rate offset Step size External clock (SDH transmitter) Connector Reference clock Reference signal 3.6 ppm 100 ppm 0.1 ppm BNC 75 (120 via external adapter) 2048 kHz 2048 Kbps (HDB3) scrambled NRZ 0.2 to 1V SMA/50 1 dB
(1)
Mappings (to ITU G.707) The following mappings are provided as standard with the instrument C12 mapping (2 Mbps in STM-1, AU-4, asynchronous mode) C3 mapping (34 Mbps in STM-1, AU-4) C3 mapping (45 Mbps in STM-1, AU-4) C4 mapping (140 Mbps in STM-1) SDH output signals STM-1 signal consists of one VC-n container with Framed or unframed PDH test pattern Test pattern without stuffing bits (bulk signal to O.181) Content of nonselected containers STM-1 PRBS 2111 (framed/unframed as per selected container) STM-4 signal consists of one VC-n container with Framed or unframed PDH test pattern or test pattern without stuffing bits (bulk signal to O.181) Three VC-4 containers each filled with a fixed pattern of 11100110 STM-16 signal consists of VC-n containers with Framed or unframed PDH test pattern or test pattern without stuffing bits (bulk signal to 0.181) SOH and POH generation The content of all bytes, with the exception of A1/A2, B1/B2/B3 and H1 to H4, is programmable with any byte. Selectable synchronization messages (S byte) Selectable signal labels (C byte) Trace identifier J0 programmable 1 byte hexadecimal or 16 byte ASCII sequence with CRC J1, J2 programmable 16 byte ASCII sequence with CRC or 64 byte ASCII sequence PDH output signals Signal structures for all bit rates Unframed test pattern Framed test pattern (to ITU-T O.150) Frame types 1544 Kbps unframed, SF, ESF 2048 Kbps unframed, PCM31, PCM31CRC PCM30, PCM30 CRC (to ITU G.704) 34368 Kbps unframed, framed G.751, framed G.832 44736 Kbps unframed, framed C-parity, framed M13 139264 Kbps unframed, framed G.751
Test patterns Test patterns may be generated and measured for any of the provided bit rates either directly at the SDH/PDH interface or within the STM-16/STM4/STM-1 substructure. Additionally, test patterns can be generated and measured at 64 Kbps and nx64 Kbps rates within an E1 frame. PRBS: 2151, 2201, 2231, 2311, 2151 inv., 2201 inv., 2231 inv, 2311 inv. Programmable word 16 bits Anomaly and defect insertion Defect generation Static ON/OFF Anomaly generation single or at a continuous error ratio of 1x10n where the range of n is as indicated below Payload Bit errors (TSEs): n=2-9 SDH structure Anomalies B1, B3 n=4-9 MS-REI, LP-BIP (except C4), LP-REI (except C4) n=3-10 B2 n=3-9 HP-REI n=4-10 SDH anomaly burst generation anomalies: B1, B2, MS-REI, B3, HP-REI, LP-BIP, LP-REI Anomalies are injected in n consecutive frames every m frames or seconds Defects LOS, LOF, RS-TIM, MS-AIS, MS-RDI, AU-LOP, AU-AIS, HP-UNEQ, HP-RDI, HP-TIM, HP-PLM, TU-LOP, TU-AIS, TU-LOM, LP-UNEQ, LP-RDI, LP-TIM, LP-PLM, LP-RFI PDH structure Anomalies FAS n=3-10 EBIT (framed 2 Mbps only) n=3-10 CODE (framed 2 Mbps only) n=3-8 CRC (framed 2 Mbps and 1.5 Mbps ESF only) n=3-9 P-BIT (framed 45 Mbps only) n=4-8 Defects AIS, LOF, RDI, LOS Yellow (1.5, 45 Mbps) Idle (45 Mbps only) DS1 code error inject DS3 error code/PVP analysis SDH and PDH receive signals Signal structures as for generator unit
Error measurements Error types B1, B2, B3, MS-REI, HP-REI, LP-REI, TSE, LP-BIP, PDH, FAS-45, FAS-34, FAS-2,FAS-1.5, REI-45, CPBIT, EBIT-2, CRC-2, code errors (2 Mbps), HP-IEC, LP-IEC, HP-OEI, HP-TC-DIFF, HP-TC-REI Alarm detection All alarms are monitored and detected simultaneously. Alarm types LOS, OOF, LOF, MS-AIS, MS-RDI, RS-TIM, AU-AIS, AU-LOP, AU-NDF, HP-RDI, HP-UNEQ, HP-TIM, HP-PLM, TU-AIS, TU-LOP, TU-LOM, LP-RDI, LP-PLM, LP-UNEQ, LP-TIM, LSS, LP-RFI, PDH-AIS, PDH-RDI, Yellow (1.5, 45 Mbps only) Idle (45 Mbps only) Receive signal frequency measurement Receive signal frequency is displayed and deviation from nominal shown in ppm. Resolution 0.1ppm OK summary display Display of large OK for error free circuits for fast and simple installation checks. Upon detection of any anomaly or defect the OK is removed and replaced with a hierarchical list of events allowing easy diagnosis of problems. Display of signal structure with BER or BLER displayed simultaneously. LED event history On screen soft LEDs and defect panel alarms can be set to display historical events. These are displayed yellow to easily distinguish them from current alarms that are displayed red. Performance analysis ITU-T recommendation G.821 ES, EFS, SES, DM and UAS are evaluated. Pass/fail assessment based on line length allocation of 1 to 100%. Evaluation for higher bit rates (up to 140 Mbps) is obtained using a multiplex factor as per annex D of G.821. Measurements can be made using the following events: bit errors (TSEs), FAS-2, CRC-4 and E bit and code errors (2 Mbps), FAS-34, FAS-140.
ITU-T recommendation G.826 EB, BBE, ES, EFS, SES, and UAS are evaluated. pass/fail assessment based on line length allocation of 1 to 100%. The SES and UAS thresholds can be set by users. In-service measurement (ISM) Simultaneous in-service measurement of the near end and far end of a selected path: Measurements can be made using the following events: RSOH B1, MSOH B2, HP B3, FAS-140, FAS-34, FAS-2, CRC and code errors (2 Mbps), LP-BIP. Out-of-service measurement (OOS) Out-of-service measurement using bit errors in the test pattern (for PDH and SDH). ITU-T recommendation G.828 Results ES, EFS, SES, BBE, SEP, UAS Pass/fail assessment based on path allocation of 1 to 100%. The SES and UAS thresholds can be set by users. Hierarchy RSOH B1, MSOH B2, HP B3, LP-BIP, TSE. ITU-T recommendation G.829 Results ES, EFS, SES BBE, UAS The SES threshold can be set by users. Hierarchy RSOH B1, MSOH B2, TSE. ITU-T recommendation M.2100 ES, EFS, SES and UAS are evaluated. Pass/fail assessment based on line length allocation of 1 to 100%. The UAS and BISO (bringing into service objectives) thresholds can be set by users. PDH systems Measurements can be made using the following events: TSEs, FAS-1.5, FAS-2, FAS-34, FAS-140, CRC, and code errors (2 Mbps). ITU-T recommendation M.2101 ES, EFS, SES, BBE, SEP, and UAS are evaluated. Pass/fail assessment based on line length allocation of 1 to 100%. The UAS and BISO (bringing into service objectives) thresholds can be set by users. ISM simultaneously for near end and far end of a selected path: Measurements can be made using the following events: TSE, LP-BIP, HP-B3, MSOH-B2, RSOH-B1.
Defect panel On-screen hierarchical LED indication of defects. Event log Tabular display of time stamped events. Anomaly count Table of all anomalies with measured count and ratio. Graphical display (histogram) Display of errors and alarms as bar graphs versus time. Zoom function allows display resolution of seconds, minutes, hours and days. SOH and POH evaluation Display of complete SOH and POH in hex, binary and ASCII formats. Text decode of S and C bytes for the trace identifier. J0 display of 16 byte ASCII sequence. J1, J2 display of 16 or 64 byte ASCII sequence. Auto protection switching (APS) Operates on SDH and PDH interfaces Measurement triggers MS-AIS, AU-AIS, TU-AIS, or bit error Pass/fail user specified time limit 10 to 2000 ms 1 ms resolution Service disruption Measurement start trigger TSE, AIS Measurement stop trigger Last event K-Byte capture Captures K1 and K2 Byte Capture trigger User selectable Tandem connection monitoring (TCM) Analysis of N1 and N2 bytes Monitoring/display of: TC-IEC, TC-AIS, TC-REI, TC-OEI, TC-UNEQ, LTC, TC-AIS, TC-RDI, TC-ODI, TC-REI Online display of TCM access point identifier TCM error measurement Incoming B3/computed BIP comparison
Round trip delay (RTD) Resolution Except for: E1 PDH E1 SDH VC12 E2 (when carried within PDH E3 or E4) VC11/12bulk Measurement range Pointer analysis and generation Pointer analysis Pointers analysed AU, TU Current pointer values displayed Displays counts of: pointer increments pointer decrements increments and decrements, sum and difference new data flags (NDFs) Average deviation (in ppm) of AU and TU User selectable recording of pointer events into the event log. Pointer generation Pointer generation in AU, TU Generation of pointers by: single pointer increment single pointer decrement rated pointer increment rated pointer decrement Frame rate: 100 to 8000 Repetitive BER test BER evaluation over user definable period 1-99 seconds Automatically repeating feature Progress bar displays the current test period Large character display of BER result VC-12 tributary scan Enables sequential BER testing of C12 channels using configured test pattern. Automatically scans selected VC-12 containers for defects and anomalies. +/- 1 s +/- 100 s +/- 100 s +/- 10 s +/- 10 s 10 s
Concatenated mappings option (BN4565/93.59) Enables measurements of contiguous concatenated signals (STM-4c/16c): VC-4-4c (requires optical interfaces STM-4 or higher) VC-4-16c (requires optical interface STM-16) STS-12c (requires optical interfaces STM-4 or higher and SONET option) STS-48c (requires optical interface STM-16 and SONET option) PDH mux/demux option (BN4565/93.58) For testing of legacy PDH systems. Generates structured signals from nx64 Kbps to 140 Mbps. Output signal hierarchy 2, 34, 140 Mbps Structure depth nx64 Kbps, 2, 8, 34 Mbps E1 Sa bit Tx generation and Rx display SONET STS-1/STS-3c/OC12c(3) mapping option (BN4565/93.62) Enables to generate and receive STS-3/OC3 and OC12 signals. Transmitter and receiver specifications as defined. Signal structures and measurements as defined for SDH above. The following mapping is provided: 599040 Kbps via STS-12c SPE E4 via STS-3c SPE DS3/E3 via STS-1 SPE SDH AU-3/SONET VT mapping option (BN 4565/93.53) AU-3 mapping function enables testing of DS-1, E1, E3 and DS3 tributaries mapped into STM-1 signal via VC-3/AU-3: VC11/TU11 (1544Kbps in STM-1 via TU11, AU3) VC11/TU12 (1544Kbps in STM-1 via TU12, AU3) VC12 (2048Kbps in STM-1 via TU12, AU3) VC3 (34368Kbps in STM-1 via VC3, AU3) VC3 (44736Kbps in STM-1 via VC3, AU3) The VT mapping function enables testing of DS-1 and E1 tributaries mapped into an STS-1 SPE via VT-1.5 and VT2 SPEs (requires option BN 4565/93.62 SONET STS-1/STS-3c/OC12c mapping) ATM (option) (BN4565/93.54) For testing of ATM services carried over PDH, SDH, and SONET Tests ATM over DS1, E1, E3, DS3, E4, VC-4/0C12 and VC-4c/0C12c, STS-1SPE CBR and VBR traffic generation Full cell header editing Cell BER tests O.191 QoS measurements ATM link and channel statistics OAM cell generation and analysis for VC/VP AIS and RDI ATM Channel Explorer
Remote operation option (BN4565/93.60) Enables ANT-5 to be remotely operated via V.24 or Ethernet from a s/w emulation of the instrument GUI running on a Windows PC. Remote control option (BN4565/93.61) Enables ANT-5 to be remotely controlled over V.24 using SCPI command set. Measurement timers Variable 1 second to 99 days Measurement start manual or delayed start timer Measurement stop manual or automatic timer Display of elapsed time hh:mm:ss Results memory Resolution of error events 1 second Alarm resolution 100 ms Memory capacity up to 10,000 entries (approx. seven days at one entry per minute) Alarm notification Anomalies and defects are indicated via LEDs, onscreen graphic icons and via an audio beeper. Printing Setups and measurement results can be printed using printers compatible with DeskJet, Thinkjet, Epson 9, and Epson 24 print drivers. Printer/remote interface Serial V.24/RS 232 Parallel using adapter cable K1589 ASCII printing possible Result export Results can be exported to PC in .CSV format using V.24, Ethernet (requires remote operation option BN4565/00.60) or a CompactFlash card. These can be processed using standard PC software, such as Excel, Word. Result evaluation (off line) Results (ANT-5 format) can be loaded, analyzed and printed by any Windows-based PC using the ANT-5 Off-line Viewer SW. Enables generation of specific setups with easy download to the unit.
Ethernet port RJ-45 Connector 10Base T TCP/IP Display Color TFT LCD screen Resolution 320 x 240 pixels Languages The user interface can be displayed in the following languages: English, German, French, Spanish, Portuguese, and Chinese CompactFlash CompactFlash card slot - Type I and II Power outage function In the event of an AC line power failure during a measurement, continues to perform measurements using its internal batteries. General specifications Power supply AC line voltage using series specific adapter 100 to 240 V AC line frequency 50/60 Hz Typical operating time on batteries 3 hours Safety class to IEC 1010-1 Part 1 (for connection to SELV only) Pollution environment degree 2 Installation category II (indoor use) Ambient temperature Nominal range of use +5 C to +45 C Storage and transport range 20 C to +60 C Weight and dimensions (L x W x H) - 275 mm x 197 mm x 76 mm - Weight 2.2 kg
Accessories *CF card (> 16 MByte) and adapter BN4565/00.42 *Neckstrap BN 4562/00.53 *PPS-2 power Supply BN 4565/00.57 * Power Cord (Select: European, US, Australian, UK) * Operating Manual BN 4565/98.xx (Select: English, German, French, Spanish, Italian, Chinese)
* included with PDH/ SDH Access Tester
Optical options (equipped with FC/PC interface) 1310 SR BN4565/00.01 1310SR/1550LR BN4565/00.03 Optics STM-1/-4 1310 SR BN4565/91.13 Optics STM-1/-4 1310SR/1550LR BN4565/00.14 Optics STM-1/-4 1310LR/1550LR BN4565/91.15 Optics STM-1/-4/-16 1310LR/1550LR BN4565/91.16 Options (New Build) (applicable when ordering with a new unit) Concatenated Mappings BN4565/93.59 PDH Mux/Demux BN4565/93.58 Remote Operation BN4565/93.60 Remote Control / SCPI command list BN4565/96.61 SONET option (STS-1, STS-3c,OC-12c) BN4565/93.62 SDH AU3/SONET VT mapping BN4565/93.53 ATM option BN4565/93.54 Options (Customer Installed) (applicable for upgrades of already delivered units)
specify serial number of the instrument when ordering
Transportation cases Hard carrying case Soft carrying case Peripheral cables Printer cable Modem cable Serial to parallel printer cable Optical cables (Singlemode, 2 meters) FC-PC to FC-PC FC-PC to SC/PC DIN 47256 to FC-PC FC-PC to E2000 FC-PC to E2000 APC FC-PC to ST-PC FC-PC to Radiall VFO FC-PC to FC-APC FC-APC to FC-APC Electrical cables BNC to BNC (2m) RJ-48 (M) to 2xCF RJ-48 (M) to RJ-48 RJ-48 (M) to RJ-48 (M)/ (F)
* When selecting these cables, please order 2 pcs. (one required for Tx, one required for RX )
BN4565/00.76 BN4518/00.08
Acterna AdvantageSM adding value with global services and solutions From basic instrument support for your field technicians to management of complex, company-wide initiatives, Acternas service professionals are committed to helping you maximize your return on investment. Whatever your needs product support, system management, education solutions, tailored test & measurement solutions or refurbished equipment we offer programs that will give you the competitive edge. To learn more about how Acterna can help your business be more successful, visit the services section on your local web page at www.acterna.com.
Concatenated Mappings BN4565/95.59 PDH Mux/Demux BN4565/95.58 Remote Operation BN4565/95.60 Remote Control / SCPI command list BN4565/96.61 SONET option (STS-1, STS-3c,OC-12c) BN4565/95.62 SDH AU3/SONET VT mapping BN4565/95.53 ATM option BN4565/95.54
Acterna is the worlds largest provider of communications test solutions for telecommunications and cable network operators. A trusted communications test partner for more than eight decades, Acterna offers an unmatched portfolio of awardwinning instruments, systems, software and services that help its customers reduce network costs while improving performance and reliability. Headquartered in Germantown, Maryland, USA with European and Asia-Pacific operations based in Eningen, Germany and Hong Kong Acterna serves nearly every major communications service provider and equipment manufacturer around the world through a skilled sales and support organization in 31 countries.
Worldwide Headquarters One Milestone Center Court Germantown, Maryland 20876-7100 USA Acterna is present in more than 80 countries. To find your local sales office go to: www.acterna.com
Regional Sales Headquarters North America One Milestone Center Court Germantown, Maryland 20876-7100 USA Toll Free: 1 866 ACTERNA Toll Free: 1 866 228 3762 Tel: +1 301 353 1560 x 2850 Fax: +1 301 353 9216 Latin America Acterna do Brasil Ltda. Av. Eng. Luis Carlos Berrini 936 9th Floor 04571-000 So Paulo SP-Brazil Tel: +55 11 5503 3800 Fax:+55 11 5505 1598 Asia Pacific Acterna Hong Kong Ltd. Room 902, 9th Floor Bank of East Asia Harbour View Centre 56 Gloucester Road Wanchai, Hong Kong Tel: +852 2892 0990 Fax:+852 2892 0770 Western Europe Acterna Germany GmbH Mhleweg 5 Germany Tel: +49 7121 86 2222 Fax:+49 7121 86 1222 Eastern Europe, Middle East & Africa Acterna Austria GmbH Aredstrasse 16-18 A-2544 Leobersdorf Tel: +43 2256 65610 Fax:+43 2256 65610-22 Acterna Moscow Prospect Mira 26, stroenie 5 RF-129090 Moscow Tel: +7 095 937 88 04 Fax:+7 095 775 26 05
ANT5STM16/DS/ACC/03-04/AE
Copyright 2004 Acterna, LLC. All rights reserved. Acterna, Communications Test and Management Solutions, and its logo are trademarks of Acterna, LLC. All other trademarks and registered trademarks are the property of their respective owners. Major Acterna operations sites are IS0 9001 registered.
Note: Specifications, terms and conditions are subject to change without notice.