Adjust sensing level(Set) by *, key, when fine

adjustment of the sensing level(Set) is needed.


(Enable adjustment range: Between 3c! and 3c?)
DGTAL PRESSURE SENSOR
PSA/PSB SERIES
1. Do not appIy the pressure beyond rated pressure.
t may cause damage to this unit.
2. Do not use it beyond power suppIy.
t may cause damage to this unit.
3. Do not make a short circuit for the Ioad.
t may cause damage to this unit.
4. Do not wire incorrectIy in power poIarity etc.
t may cause damage to this unit.
5. Do not use corrosive gas or Iiquid as it is onIy for non-corrosive gas.
t may cause damage to this unit.
6. Do not give power to its case or twist its case strongIy.
t may cause damage to this unit.
7. This unit shaII not be used outdoors.
t may shorten the life cycle of the product or give an electric shock. This unit is produced only for the
indoor environment.
InstaIIation
Input/Output circuit and connection diagram
Specifications
~Window comparison output mode(5)
t is able to set Low/High-limit value of pressure
sensing level in this mode.
Hysteresis is fixed in 1digit.(2digits for compound
pressure or psi unit type)
Functions
~Pressure dispIay unit change function
PS-V01(C)(P) and PS-C01(C)(P) has 7 kinds of pressure unit, PS-01(C)(P) and PS-1(C)(P) has
4 kinds of pressure unit. Please select the proper unit for application.
PS-V01(C)(P), PS-C01(C)(P) : kPa, kgf/cm, bar, psi, mmHg, inHg, mmH2O
PS-01(C)(P), PS-1(C)(P) : kPa, kgf/cm, bar, psi
When using mmH2O unit, multiply display value by 100.
~Output operation mode change function
There are 6 kinds of control output mode in order to realize the various pressure sensing.
Select a mode for your proper application.
Hysteresis mode(!) : When needed to change hysteresis for sensing pressure.
Automatic sensitivity setting mode(?): When needed to set sensing sensitivity automatically at
proper position.
ndepentent two output mode(J, ', 5): When needed to detect pressure from two position with
one unit.
Window comparison output mode(5) : When needed to detect pressure in certain area.
~Response time change function(Chattering prevention)
t can prevent chattering of control output by changing response time. t is able to set 4kinds of response
time(2.5ms, 5ms, 100ms, 500ms) and if the response time is getting longer, the sensing will be more
stable by increasing the number of digital filter.
~AnaIog output scaIe setting function
t is not fixed the analog output(1-5VDC) scale as the rated pressure range but this is a function to
change properly for user's application. f A1 position for 1VDC output and A5 position for 5VDC output
are set, the pressure range of A1 to A5 is to 1-5VDC analog output.
~Key Iock function
This unit has 2 kinds of key lock function in order to prevent wrong operation.
'o: All keys are locked therefore it is impossible to change any parameter setting/ preset, zero point
adjustment, peak hold and bottom hold check. (t is able to change the status of lock)
.': This is partial locked status, therefore it is impossible to change parameter setting(t is able to
change the status of lock) only, the other functions can be changed.
J': All of the setting is available, all keys are unlocked.
~Zero point adjustment function
This function is to set the display value of pressure as zero point forcibly in case that of port is opened to
atmospheric pressure. Zero point adjustment affects analog output voltage.
~Peak hoId and bottom hoId function
This function is to diagnosis malfunction of the system caused by parasitic pressure or to check through
memorizing the max./min. pressure occurred from the system.
Front paneI identification and function
Setting
Output operation mode
PSA/PSB series has 6 kinds of output operation mode, please use proper output operation mode in
accordance with sensing.
~Hysteresis mode(!)
t is able to set certain value for pressure
sensing level(3c!) and hysteresis(3c?).
~Independent two output mode(J, ', 5)
t is able to set pressure sensing level from two
positions(3c!, 3c?) in this mode, one is for
control and the other is for alarm or additional
control.
Hysteresis is fixed in 1digit. (2 digits for compound
pressure or psi unit type)
~Automatic sensitivity setting mode(?)
This function is to set pressure sensing level to
the proper position automatically. t is set by
receiving pressure from two positions(3c!, 3c?).
Hysteresis is fixed in 1digit.(2 digits for compound
pressure or psi unit type)
The pressure sensing level is shown in the
following calculation.
Error
Accessory
Main products
Caution for using
1. Do not insert any sharp or pointed object into pressure port.
lt could not operate normally due to mechanical trouble.
2. Be sure that this unit must avoid direct touch with water, oil, thinner etc.
3. Be sure to avoid transient time(within 3sec.) after initial power on.
4. When a switching moving regulator is used for power supply, frame
ground(F.G.) terminal of its power supply part must be grounded.
5. Avoid wiring with power line or high voltage line.
lt may cause malfunction by noise.
6. When moving this unit from cold place to warm place, please remove
the humidity on the cover then use it.
7. Do not press the setting button with sharp or pointed object.
8. Do not apply over 30N tensile strength on connection part or load.
9. When using mmH2O unit, multiply display value by 100.
10. nstallation environment
t shall be used indoor Altitude Max. 2,000m
Pollution Degree 2 nstallation Category
~Preset vaIue setting
1. Set the pressure sensing level.
2. Please set preset value after unlocking key lock
when key lock function is set.
(Please see key lock setting)
3. Be sure that the setting method is different by
each output operation mode.
When hysteresis mode(!) and independent two
output mode(J, ', 5)
~Parameter setting
1. Set to pressure display unit, output operation
mode, response time(Chattering prevention),
analog output scales or key lock.
2. Please set parameter after unlocking key lock
function when key lock function is set.
(Please see below key lock setting)
Return to RUN mode
Display unit setting
kPa kgf/cm bar psi mmHg inHg mmH2O
(Pressing key shortly, the unit is saved, then moves
to the next setting mode.)
When using mmH2O unit, multiply display value by
100.
M
RUN mode
Response time setting
and previous set response time flashes in
0.5sec. by turns.
Select the response time by * , key.
Analog output scale setting(5VDC)
and previous set pressure will flashes in
0.5sec. by turns.
Set the pressure value which 5VDC is output by
*, key.
Available setting range :
[!]+10% of rated pressure > [5] >Max. value
of rated pressure
(Pressing key shortly one time, the selected
pressure is set as 5VDC scales then moves to the
next setting mode.)
M
Automatic sensitivity setting mode(?)
(Saves in EEPROM)
(Saves in EEPROM)
Return to RUN mode
Window comparison output mode (5)
Pressure sensing level 1 setting
and the previous sensing level 1 flashes in
0.5sec. by turns.
Set pressure sensing level 1 by * , key.
Enable setting range: Min. setting pressure >Lo <
Max. value of setting pressure
(Pressing key shortly one time, sensing level 1 is
set then move to next setting mode.)
RUN mode
Return to RUN mode
RUN mode
and the previous detection level 2 flashes in
0.5sec. by turns.
Set pressure sensing level 2 by * , key.
Enable setting range: Lo < Hi > Max. value of setting
pressure
(Pressing key shortly one time, the setting is
completed then returns to RUN mode.)
Pressure detecting level 2 setting
M
Please check the preset value again when output
operation mode is changed.
When the display unit is changed, preset value is
calculated according to the display unit.
f no key touched for 60sec., it returns to RUN mode
[Except for automatic sensitivity setting
mode(?)]
Whenever * ( )key touched one time, 1digit
(2digits when using psi unit or compound pressure
type) is increased(decreased) and it is continuously
increased(decreased) by pressing key constantly.
M A N U A L
Display
unit
setting
Zero point adjustment
Para-
meter
setting
Peak
hold
Zero
point
adjust
-ment
Output
operation
mode
setting
Analog
output scale
setting
(1VDC)
Analog
output scale
setting
(5VDC)
Key
lock
setting
Peak hold Bottom hold
R
U
N
m
o
d
e
Response
time
setting
Sensing level 2 setting
(3c?, Hi)
Preset
value
setting
Press
within 3sec.
M
Press
more than
3sec.
Press
more than
3sec.
~Zero point adjustment
1. press * and keys for over 1sec. at
the same time putting an applied pressure in
state of the atmospheric pressure.
2. When the zero point adjustment is completed,
it displays and returns to RUN mode
automatically.
f executing zero point adjustment on external
pressure being at pressure port flashes
3times. Please execute it in the atmospheric
pressure after removing external pressure.
Please execute zero point adjustment regularly.
Press more than 3sec.
(Saves in EEPROM)
Press more than 3sec.
and previous set unit flash in 0.5sec. by turns.
Select the unit by *, key.
Display pressure unit of
positive pressure type
Display pressure unit of vacuum pressure type and
compound pressure type
Output operation mode setting
(Pressing key shortly, the output operation mode
is saved, then moves to the next setting mode.)
M
and previous set output mode flash in 0.5sec.
by turns.
Select the output operation mode by * , key.
2.5ms 5ms 100ms 500ms
(Pressing key shortly, the response time is saved,
then moves to the next setting mode.)
M
Analog output scale setting(1VDC)
and previous set pressure flash in 0.5sec. by
turns.
Set the pressure value which 1VDC is output by
*, key.
Available setting range:
Min. value of rated pressure > [!] >90% of
rated pressure
(Pressing key shortly one time, the selected
pressure is set as 1VDC scales then moves to
the next setting mode.)
M
Key lock setting
M
and previous set key lock flashes by turns.
Select key lock by *, key.
(Pressing key shortly one time, key lock is set
then moves to the display unit setting mode.)
When pressing key for over 3sec. in any setting
mode, it returns to RUN mode memorizing set value
at EEPROM. Also, if no key touched for 60sec. it
displays previous setting value with ignoring current
setting.
Setting data is saved at by EEPROM even though
the power off. But, note that the life cycle of EEPROM
is 100,000 times.
M
~Peak hoId and bottom hoId
1. Press *for more than 3sec. in RUN mode.
2. and memorized max. pressure(Vacuum type
is for max. vacuum pressure) flashes in 0.5sec. by
turns.
3. Press *key one time shortly, then it displays bottom
hold value. and memorized min. pressure
(Vacuum type is for max. vacuum pressure) flashes
in 0.5sec. by turns.
4. f pressing *key one time shortly, memorized peak
hold and bottom hold value is removed then returns
to RUN mode.
When the peak hold value is over than display
pressure range, it displays .
Bottom hold value is below than display pressure
range, it displays .
Pressure sensing level 1 setting
and previous set sensing level1 flash in 0.5sec.
by turns.
Set the pressure sensing level 1 by *, key.
Enable setting range: Min. value of setting
pressure < 3c! > Max. value of setting pressure
(f pressing key shortly one time, sensing level 1 is
set then move to the next setting mode.)
M
RUN mode
Pressure sensing level 1 setting
and previous set sensing level 1 flash in 0.5sec.
by turns.
Apply the needed pressure(3c!) within the rated
pressure.
f pressing * key shortly one time, current sensing
pressure is set sensing level 1, and the set
sensing level1 flash by turn (0.5sec.).
and sensing level(Set) flash in 0.5sec. by turns.
Automatic sensitivity setting and fine
adjustment
When checking the value of sensing level 1, 2(3c!,
3c?) and automatic sensitivity setting value, please
press key shortly and sequently.
Example of the setting in automatic sensitivity setting
mode (To check absorption of component by vacuum
pressure). The state of removed target is 3c! and the
state of absorbing target is 3c?. By *key, sensing
level (SET) value is set in the middle between 3c!
and 3c? automatically.
Return to RUN mode
M
M
Switching
regulator
+
-
F.G.
Ground
Pressure sensing level 2 setting
and previous set sensing level 2 flash in 0.5sec.
by turns.
Set the pressure sensing level 2 by * , key.
Enable setting range: Hysteresis mode
Min. value of setting pressure > 3c? < 3c!
independent two output mode Min. value of setting
pressure < 3c? >Max. value of setting pressure
(Pressing key shortly one time, the setting is
completed then returns to RUN mode.)
M
Output voltage:1V-5VDC 2% F.S.
Zero point:Within 1VDC 2% F.S.
Resolution:Approx. 1/200
kPa, kgf/cm
2
, bar, psi
Linear:Within 2% F.S.
Span:Within 4VDC 2% F.S.
Output impedance:1kO
2digits
NPN open collector output = Sink current: Max. 100mA,
Applied voltage: Max. 30VDC, Residual voltage: Max. 1V
PNP open collector output = Source current: Max. 100mA, Residual voltage: Max. 2V
3 digit LED 7segment
1digit(psi unit: 2 digits are fixed)
NPN output
PNP output
kPa, kgf/cm
2
,bar, psi,
mmHg, mmH2O, inHg
kPa, kgf/cm
2
, bar, psi,
mmHg, mmH2O, inHg
,
~NPN open collector output type ~PNP open collector output type
Pressure sensing level 2 setting
and previous set sensing level 2 flash in 0.5sec.
by turns.
Apply the needed pressure(3c?) within the rated pressure.
f pressing *key shortly one time, current sensing
pressure is set as sensing level 2, then and the
set sensing level 2 flash in 0.5sec. by turns.
Enable setting range: 3c!+1% of rated pressure >
3c? >Max. value of setting range
f differences of between 3c! and sensing level are
not enough, flashes 3 times then retruns to 3c?
setting. Please re-execute the setting for condition.
t is possible to set repeatedly by * key, the last
setting is set as the sensing level2.
Thank you very much for selecting Autonics products.
For your safety, pIease read the foIIowing before using.
Caution for your safety
1. In case of using this unit with machinery (Ex: nucIear power controI, medicaI equipment, ship, vehicIe,
train, airpIane, combustion apparatus, safety device, crime/disaster prevention equipment, etc) which
may cause damages to human Iife or property, it is required to instaII faiI-safe device.
t may cause a fire, human injury or damage to property.
2. Do not use it in fIammabIe gas because it does not have an expIosion proof construction.
t may cause explosion.
Port plug Bracket A Bracket B
~PSA/PSB (Pressure unit IabeI) ~PSA
-101.3kPa 100kPa 1MPa
-1.034kgf/cm 1.020kgf/cm 10.20kgf/cm
-14.70psi 14.50psi 145.0psi
1.000bar 10.00bar
-760mmHg
-29.9inHg
-103.4mmH O
DSPLAY UNT LABEL
2 2 2
-1.013bar
2 X1000
*100kPa
*1.020kgf/cm
*14.50psi
*750mmHg
*29.5inHg
*102.0mmH O
2
*1.000bar
2
X100
X10
X1000
X100
X10
~PSA series
1. When installing pressure port it is able to bring
pressure from 3 directions by changing the
mounting direction of the pressure port.
2. Pressure port has two types, PT1/8 and
NPT1/8, therefore be sure to use proper port
when using one touch fitting.
3. Please use seal tape at port plug in order to
prevent pressure leak.
4. Please block another two pressure ports not
used with port plug.
5. Please connect it by using spanner(13mm) at
the metal part in order not to overload on the body
when connecting one touch fitting.
6. PSA series has 2kinds of brackets so it is able to
install it in two different ways.
7. At first, please unscrew hexagon wrench bolt
and assemble the bracket on this unit by fixing
the hexagon wrench bolt.
n this case, tightening torque of hexagon
wrench should be max. 30kgf cm.
t may cause mechanical trouble.
The tightening torque of one touch fitting should be
Max. 100kgf cm.
t may cause mechanical trouble.
8. Bracket(PSO-01) and front protection cover
(PSO-02) are sold separately.
Please refer to the below pictures for installation.
13mm Spanner
Bracket
panel
Protection
cover
(PSO-02)
Panel bracket
(PSO-01)
Body
(PSA)
+V(Brown)
Analog voltage
output(Orange)
OUT1(Black)
OUT2(White)
1kO
0V(Blue)
+
-
Load
12-24VDC
M
a
in
c
ir
c
u
it
Load
Over current
protection
circuit
Over current
protection
circuit
~PSB series
1. Pressure port is M5.
t is able to use general one touch fitting.
2. t is able to use it without the pressure port
according to environment.
n this case O-Ring between pressure port
and ts body should not be taken out
in order to prevent pressure leak.
3. Please connect it by using spanner(10mm) at
pressure port in order not to overload on the
body when connecting one touch fitting.
! Caution
There is no over current protection circuit in analog voltage output type. Do not connect this unit to power
source or capacitive load directly.
Please observe input impedance of connected equipment when using analog voltage output.
And be sure with voltage drop by resistance of extended wire.
+V(Brown)
1kO
OUT1(Black)
OUT2(White)
0V(Blue)
+
-
Load
12-24VDC
M
a
in
c
ir
c
u
it
Analog voltage
output
(Orange)
Load Over current
protection
circuit
Over current
protection
circuit
Hexagon
wrench bolt
Port plug
Spring washer
Pressure
Time
OUT1
OUT2
ON
OFF
ON
OFF
Hi
Lo
Pressure
3c?
Set
3c!
Time
OUT1
OUT2
ON
OFF
ON
OFF
OUT1
OUT2
OUT1
OUT2
Time
OUT1
OUT2
J
'
5
3c?
3c!
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Pressure
Pressure
3c!
3c?
OUT1
OUT2
Time
ON
OFF
ON
OFF
Please keep these instructions and review them before using this unit.
Please observe the cautions that follow;
Serious injury may result if instructions are not followed.
Product may be damaged, or injury may result if instructions are not followed.
The following is an explanation of the symbols used in the operation manual.
caution:njury or danger may occur under special conditions. !
!
!
Dimensions
Front protection
cover
(PSO-02)
Mounting
bracket
(PSO-01)
~PSA series
(Unit:mm)
Mounting bracket
PSA-01
36
+0.5
0
3
6
+
0
.5
0
~PSB series(CabIe integrated type)
Option
(Unit:mm)
50
28
4
3
.
4
1
.
6
Bracket A Bracket B
41
39.4
28
3
0
1
5
PSA-01
PSO-01
PSO-02
~PSB-C series(Connector type)
1
9
4
2-M2 TAP
Pressure port
(M5 depth 5mm)
Pressure port
(M5 depth 5mm)
2-M2 wrench bolt
4
1
0
52
8 44
100kPa
M M
OUT 1 2
54.2
M
1
0
.
3
7 47.2
M
OUT 1 2
*100kPa
2
5
.
5
2-3.4
1
8
.
7
5
6
.7
5
1
2
4.5
Mounting hole(M3 Bolt)
2
5
1
8
.
5
6
.
5
4
2-3.4
Mounting hole(M3 Bolt)
1
2
Error display Description Countermeasures
f external pressure applied, when adjusting
Zero point
When overloaded on control output
When the setting value is not matched with
setting condition
When the applied pressure exceeds the upper
display pressure range up
When the applied pressure exceeds the lower
display pressure range down
Please try again after external pressure
removing
Remove overload
Set proper setting value after checking
setting condition
Apply pressure within display pressure
range
The tightening torque of one touch fitting and
hexagon wrench should be Max. 50kgf cm and
20kgf cm. t may cause mechanical trouble.
Please do not use spanner to install as it may cause
mechanical trouble.
One touch fitting
Hexagon wrench bolt
(M2X10)
O-Ring
Body
Pressure port
Hexagon
wrench bolt
Spring
washer
(Connector type)
(Cable integrated type)
PSA PSB
Set =
(3c! + 3c?)
2
! Caution
Proximity sensors
Area sensors
Door/Door side sensors
Counters
Rotary encoders
Power controllers
Panel meters
Temperature controllers
Tachometer/Pulse(Rate) meters
Temperature/Humidity transducers
Switching power supplies
Stepping motors/drivers/motion controllers
Field network devices
Laser marking system(CO2, Nd:YAG)
Laser welding/soldering system
HEAD QUARTERS :
41-5, Yongdang-dong, Yangsan-si, Gyeongnam, 626-847,
Korea
OVERSEAS SALES :
Bldg. 402 3rd Fl., Bucheon Techno Park, 193, Yakdae-dong,
Wonmi-gu, Bucheon-si, Gyeonggi-do, 420-734, Korea
TEL:82-32-610-2730 / FAX:82-32-329-0728
E-mail : sales@autonics.com
Satisfiable Partner For Factory Automation
The proposal of a product improvement
and development : product@autonics.com
Photoelectric sensors
Fiber optic sensors
Pressure sensors
Timers
Display units
Sensor controllers
Graphic/Logic panels
Press +
Press more
than 1sec.
Sensing level 1 setting
(3c!, Lo)
M
OUT 1 2

1
0
0
kP
a
PSA-01
! Warning
! Caution
M
Press one time
Press one time
Press one time
Press one time
Press one time
Press one time
Press one time
Press one time
Press one time
Press one time
Press one time
(3c! + 3c?)
2
Set =
Press one time
Press one time
(Saves in EEPROM)
Press one time
The above specification are subject to change without notice. EP-KE-77-0001L
3LED display(Red): Displays sensing pressure, every setting value and display error
1 output indicator(Red): Output 1 is ON, LED will be ON
2 output indicator(PSA: Red, PSB: Green): Output 2 is ON, LED will be ON
Mode key: Enter to parameter setting mode or preset setting mode, and save setting value
Up key: Sets the setting value to upper step in preset setting or pressure unit, output
mode, response time, analog output scale, key lock, peak hold value, bottom
hold value display in parameter setting
Down key: Sets setting value to lower step in preset setting or pressure unit,
output mode, response time, analog output scale, key lock, peak hold,
bottom hold display in parameter setting.
Range of rating pressure: t is possible to change the pressure unit in
pressure sensor. Please use different unit label for your application.
t may cause malfunction if above instructions are not followed.
PSA-V01
PSB-V01
PSB-V01C
PSA-01
PSB-01
PSB-01C
PSA-C01
PSB-C01
PSB-C01C
PSA-1
PSB-1
PSB-1C
PSA-V01P
PSB-V01P
PSB-V01CP
PSA-01P
PSB-01P
PSB-01CP
PSA-1P
PSB-1P
PSB-1CP
PSA-C01P
PSB-C01P
PSB-C01CP
2digit fixed
0.2% F.S. 1digit
0.0 to -101.3kPa 0.0 to 100.0kPa 0 to 1,000kPa
Max. 1% F.S.
2
-10 to 50, Storage: -20 to 60'
35 to 85%RH, Storage: 35 to 85%RH
PSA : Approx. 120g, PSB : Approx. 70g, PSB-C : Approx. 80g
5.0 to -101.3kPa -5.0 to 110.0kPa -50 to 1,100kPa
1digit fixed(2digits for psi unit)
Compound
pressure type
-101.2 to 110.0kPa
0.2% F.S. 2digit
Max. 2% F.S.
2
Pressure type
Rated pressure range
Max. pressure range
Applicable fluid
Power supply
Current consumption
Display pressure range
Model
Control output
Repeat error
Response time
Short circuit protection
Hysteresis
1
Analog output
Display method
Min. display interval
Pressure unit
Characteristic of
analog output
Characteristic of control
output and display temp.
Ambient temperature Environ
-ment Ambient humidity
Wire
Material
Unit weight
Gauge pressure
Vacuum
pressure type
Positive pressure type
-100.0 to 100.0kPa
2 times of rated pressure
1.5 times of rated
pressure
2 times of rated
pressure
Air, Non-corrosive gas
12V-24VDC 10%(Ripple P-P:Max. 10%)
Max. 50mA
Selectable 2.5ms, 5ms, 100ms, 500ms
Built-in
Max. 2% F.S.
2
PSA = Front case:PC, Rear case:PC(nsert glass), Pressure port:die-cast(Zn)
PSB = Case, Pressure port:PA PSB-C = Case, Pressure port, Cover: XEF
4, 5P, Length: 2m, AWG 24, nsulation diameter: 1.0
Protection P40(EC standard)
1: n ! mode, hysteresis is variable.
F.S. is the rated pressure.
The specification of pressure port is marked on the upper part of the case. Pressure ports are distinguished by the
colors, silver[Rc(PT)1/8] or black[NPT1/8].
Environment resistance is rated at no freezing or condensation.
Warning
Caution
Vibration 1.5mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours
Cable intergrated type
Connector type 5P, Length: 3m, AWG 24, nsulation diameter: 1.4
2` Display pressure at 25' within 0 to 50'
Panel cut-out :
Panel thickness
0.8mm to 3.5mm
3
4
20
30
6
3
0
3
5
.5
4
5
30
Atmospheric
pressure
inflow hole
40
30
2
8
.
2
4
2
25
35
6
2
2
2-4.2
For mounting front cover
6
41.5