Laser Scan Micrometer
Laser Scan Micrometer
Laser Scan Micrometer
1567-544
LSM-6900
Features:
s
Measuring range .004 to 1" (0.1 to 25mm) covers most precision parts. Repeatability .000002" (0.05m) highest repeatability for a 1" (25mm) LSM in the world. Linearity .00002" (0.5m) over the entire range, and higher linearity in the small range.
s s s
High Resolution Improves measurement accuracy Stable edge detection by using new algorithm. Multi-function type display.
/ [*3] [*4]
Scanning signal monitor connector Remote interlock connector Power switch Built-in interface Optional interface Power supply
Fluorescent display 16-digit + 11-digit, Guidance LEDs Segment designation 1 to 7 (1 to 3 for Transparent material) Edge designation 1 to 255 Simple averaging 1 to 2048 Averaging method Moving averaging 32 to 2048 Tolerance judgement (GO,NG); Multi-limit judgement (7 classes); Offset/Zero-set; Abnormal data elimination; Automatic workpiece detection; Reference value setting; Data output condition; Laser power deterioration; Sample measurement; Statistical processing; Dual-program measurement; Automatic measurement using edge mode; Workpiece position display; Transparent object measuring; Key-lock function; mm/inch changeover; Dual-gauge calibration; Selection of resolution; Judgement in ready state; Display of a comma to mark the thousandths position; Mastering; None-display unnecessary digits; Group judgement Provided as standard (with the plug) Provided as standard (with the plug) Key switch used RS-232C; Foot switch connector; I/O analog interface DCU slot Digimatic code output unit (2-ch) Expansion slot (1-slot) 2nd I/O analog I/F; BCD I/F; GP-IB I/F; AC100V~240V10%, 50/60Hz, 40VA
[*1]: Accuracy inspection environment/Temperature 20C1C, Humidity: 50%10% [*2]: The repeatability is determined by the value for 2 at the measurement interval of 1.28 sec. [*3]: Specified at the center of the measurement region. [*4]: v D: Diameter difference to master gage. [*5]: An error due to workpiece shift either in the optical axis direction or in the scanning direction. [*6]: The area given by [measuring range on the optical axis] x [measuring range in the scanning direction.] [*7]: The combination of functions is limited, details are described in the user's manual.
STANDARD ACCESSORIES Order No. Item 02AGC320A Signal cable (5m/16ft) 930966 Power cable 934626 GHD lead wire 956042 Short plug to Remote-interlock 214938 Plug for Remote-interlock/MP121M by Marushin 02AGC401 Plug for Scanning signal connector/MP-105LC by Marushin 02AGC604 Power ON/OFF key 02AGC605 Fuse 1A (Time-lag) 99MBC071A User's manual for LSM-6900 (English) 99MBC075A User's manual for LSM-902 (English / FDA)
Quantity 1 1 1 1 1 1 1 1 1 1
OPTIONAL ACCESSORIES Order No. Item 02AGD180 Calibration gauges set for LSM-902 02AGD270 Workstage for LSM-501/503/902 02AGD280 Adjustable Workstage for LSM-902 02AGC840 Digimatic code output unit (2-ch) 02AGC880 2nd I/O analog interface unit 02AGC910 BCD interface unit 02AGC940 GP-IB interface unit 02AGD600B Printer & cable set 223663 Printer paper 936937 Digimatic code output cable 937179T Foot switch
Distributed By:
www.mitutoyo.com