Digimatic Indicators: ABSOLUTE Digimatic Indicator ID-C SERIES 543 - Calculation Type
Digimatic Indicators: ABSOLUTE Digimatic Indicator ID-C SERIES 543 - Calculation Type
Digimatic Indicators: ABSOLUTE Digimatic Indicator ID-C SERIES 543 - Calculation Type
Digimatic Indicators
MeasurLink® (refer to page A-25 for details).
Comparison measuring instruments which ensure high quality, high accuracy and reliability.
An inspection certificate is supplied as standard.
Refer to page U-9 for details.
ABSOLUTE Digimatic Indicator ID-C
SERIES 543 — Calculation Type
Functions • Calculation function operates on spindle • The ABS (absolute) scale restores the last
• Calculation f (x’) =Ax’+B+Cx’–1
(x’=x+offset) displacement. origin position*1 automatically when the
• Peak detection (MAX/MIN) Entering the appropriate formula factors indicator is turned on, and realizes high
• Runout (MAX - MIN) Hold
Note: Peak detection for a fixture dedicated to the application reliability by eliminating over-speed errors.
1) Sampling rate: 10 readings/sec enables direct measurement readout, • By using the parameter setup kit (optional)
2) Capturing speed: 10 µm/sec (max.) thereby eliminating any need for the and the dedicated software, the functions
Settings can be changed to:
1) Sampling rate: 50 readings/sec conversion tables previously needed for those and the parameters can be configured using
2) Capturing speed: 50 µm/sec (max.) applications where fixtures are typically used. a computer.
• Zero-setting (INC system)
• Preset (ABS system) • Five buttons, status icons, and clear button • Equipped with a data output port that
• Tolerance judgment indications allow for easy operation of a wide enables incorporation into measurement
(P1, P2, P3, and INC can be stored) variety of functions. networking and statistical process control
• Analog bar resolution selectable
• Key lock • Wide LCD and new analog bar graph are systems. (Refer to page A-3)
• Display hold (when no external device is connected) now standard on all models. *1 Regarding origin setting, refer to “Origin Setting of Digimatic
• Data output Indicators” on page F-25.
• External PC setting input
• Display rotation (330°)
• Low battery voltage alarm display
• Error alarm display
• Resolution switching*
Resolution (mm) Resolution (in)
0.0002 0.005 0.1 0.00001 0.0002 0.005
0.0005 0.01 0.2 0.00002 0.0005 0.01
0.001 0.02 0.5 0.00005 0.001 0.02
0.002 0.05 1 0.0001 0.002 0.05
* S ince the calculation resolution is one micrometer (0.001
mm), using sub-micrometer resolution settings may
result in the 4th-place digit being unreliable, particularly
when B is set to a very low value and C=0. It does not
change at all with certain combinations of calculation
coefficient (for example, A=1, B=C=0). The 3rd-place
digit representing micrometers (if displayed) is always
reliable.
543-342B
Optional Accessories
• Lifting
Lifting lever 21EZA198 (ISO/JIS Type),
21EZA199 (ASME/ ANSI/AGD Type)
Lifting knob 21EZA105 (ISO/JIS Type),
21EZA150 (ASME/ ANSI/AGD Type)
Lifting cable 21JZA295
• SPC Cable:
905338 (1 m)
9 05409 (2 m) SPECIFICATIONS
• USB Input Tool Direct (2 m): 06AFM380F Metric ISO/ JIS type ASME/ ANSI / AGD type
• Input Tool Series Maximum permissible error*2
(mm)
IT-016U (USB Keyboard Signal Conversion Type): Range Resolution Measuring force Power supply Battery life Net mass
264-016-10 Order No. (selectable) Hysteresis Repeatability (normal use)*5 (g)
(mm) MPEE*3 MPL (N)
IT-007R (RS-232C Communication Conversion Type): MPEH MPER
264-007 543-340B 12.7 1.5 or less 170
0.003
• Connecting Cables for U-WAVE-T (160 mm): 543-590B 25.4 12 steps*5 0.002 0.002 1.8 or less*4 CR2032×1 pc. Approx. 1 year 190
02AZD790F 543-595B 50.8 0.006 2.3 or less*4 260
For foot switch: 02AZE140F
• Digimatic Mini-Processor DP-1VA LOGGER: 264-505 Inch/Metric
• Parameter setup kit: 21EZA313 Maximum permissible error*2
Note: P arameter setting software (can be downloaded for Resolution Measuring force Power supply Battery life Net mass
Order No. Range (selectable) Hysteresis Repeatability (normal use)*5 (g)
free from the Mitutoyo website) is also required. MPEE*3 MPL (N)
MPEH MPER
543-341B 0.5 in
1.5 or less 170
543-342B / 12.7 mm ±0.0001 in
543-591B 1 in /0.003 mm 0.0001 in 0.0001 in F
12 steps*5 1.8 or less*4 CR2032×1 pc. Approx. 1 year 190
543-592B / 25.4 mm / 0.002 mm / 0.002 mm
543-596B 2 in ±0.00025 in
2.3 or less*4 260
543-597B / 50.8 mm /0.006 mm
*2 Valid for resolution set to 0.001 mm / 0.00005 in and coefficients A=1, B=0 and C=0.
*3 Error of indication for the total measuring range
*4 Applies for a spindle orientation between the spindle pointing vertically downward to the spindle horizontal.
*5 Applies only if not connected to a data processor. Battery life depends on use of the indicator. Use the above value as a guide only.
Note: Flat back type only.
Mitutoyo reserves the right to change any or all aspects of any product specification, including prices, designs and service content, without notice. F-16