MC III EXP Specs
MC III EXP Specs
MC III EXP Specs
The MC-III EXP stores more flow logs and downloads them faster
than any other flow analyzer on the market.
This powerhouse records up to 384 daily flow logs, 768 hourly logs,
345 event logs and downloads them to your computer via Modbus in
less than a minute.
Benefits
The MC-III EXP offers:
• RS-485 Modbus communications
• Extensive log archival capacity
• High-speed data downloads
• Interactive software for quick and easy calibration
and data access
• Simultaneous indication of rate and total
• Easy-to-read LCD displays
Users can access every configuration • Loop-powered analog output
parameter from one screen.
• 12-point linearization
• Nonvolatile memory
• Password-protected security
• Optional hardware for daily log viewing and
external laptop connection
• Intrinsically safe RS-485 output (option)
• CSA, ATEX, IECEx and CE approvals
Calibration
Calibrating the MC-III EXP is as easy as entering the
calibration factor of the flow meter and selecting
the desired units of measurement. The instrument
automatically calculates its own divisor.
Day
Display Communications /Archive Retrieval
• 8-digit display of total • RTU mode Modbus
• 6-digit display of rate (11-segment characters for • Enron Modbus
easy-to-read prompts) • 16-bit slave address supported
• Character height – 0.3" • Data printouts in tabular or chart formats
• Adjustable contrast and update period • Data export to spreadsheet (.xls and .csv formats)
• User-selectable units of measurement:
Total: bbl, gal, liters, cubic meters, cubic feet, standard Inputs
cubic feet, user-defined units (and all units x 1000) Turbine Meter Input
Rate: Any of the above total engineering units per day,
• Configurable sensitivity adjustment
hour, minute or second
• Frequency range: 0 to 3500 Hz
Remote Reset Input
Calibration
• Liquid flow meter: User enters calibration factor of meter • Optically isolated
and selects units of measurement • Supply range: 3.0 to 30 VDC
• Gas flow meter: User enters calibration factor of meter, External Reset Switch (Option)
pressure and temperature parameters, and FPV via user • Explosion-proof
interface software • Daily log viewing capabilities
Pulse Input
Power Supply Options • Optically isolated
• 3.6 VDC lithium battery pack • Supply range: 3.0 to 30 VDC
2-year life, typical (main or backup power supply)
• Frequency range: 0 to 3500 Hz
• Alkaline battery pack option (main or backup power supply)
CSA approved devices only
Outputs
not recommended for temperatures consistently
Analog Output
below 20° F (-7° C)
• External power supply (6 to 30 VDC) with internal • 4-20 mA, loop-powered (two-wire)
battery backup • 16-bit resolution
• Loop-powered (4-20 mA output) with internal • Accuracy: 0.1% of full scale at 77° F (25° C), 50 PPM/°C
battery backup temperature drift
• Loop power: 8.0 to 30 VDC
Temperature Range • Zero and full-scale engineering values configurable
• Lithium battery: -40° F to 158° F (-40° C to 70° C) from front panel
• Alkaline battery pack (CSA only): 20° F to 140° F • Cannot be used simultaneously with amp and
(-7° C to 60° C) square output
• LCD contrast is reduced below -4° F (-20° C) RS-485 Communications
• Baud rates: 300, 600, 1200, 2400, 4800, 9600, 19,200,
Certification 38,400, 57,600 and up to 115.2K
• CSA approved for US and Canada • Optional external communications port
Class I, Div. 1, Groups B, C, D (explosion-proof) RS-485 adapter (CSA and ATEX approved)
Type 4 enclosure USB adapter (CSA approved)
T6 temperature class Volumetric Pulse Output
• ATEX/IECEx approved • Solid-state relay
Category II, Group 2, Gas/Dust • Output rating: 60 mA max at 50 VDC
Ex d IIC T6 Gb • Configurable pulse duration and scale factor
Ex tD A21 IP66 T85°C
Amp and Square Output
• CE-approved
• Open-drain transistor output of turbine meter input signal
• Complies with EMC Directive 2004/108/EC
• Output rating: 50 mA at 30 VDC
• Cannot be used simultaneously with analog output
Interface Software
• Provided at no additional charge
• Complete configuration
• Real-time data
• Downloads and exports
• “Wizard” offers step-by-step calibration procedure
• Windows® XP, Windows Vista®, or Windows® 7 required
Flow Archive
• 384 daily logs
• 768 hourly logs
• 345 event logs
K-factor changes
Input setting changes
North and South Europe, Africa, Caspian Asia Pacific Middle East
America and Russia Suite 16.02 Menara Level 9, Al Jazira Club Tower A
14450 JFK Blvd. 3 Steyning Way AmFirst P.O. Box 47280, Muroor Road
Houston, TX 77032 Southern Cross Trading Estate No. 1 Jalan 19/3 Abu Dhabi
USA Bognor Regis 46300 Petaling Jaya United Arab Emirates
Tel 1 281 582 9500 West Sussex PO22 9TT Selangor Darul Ehsan Tel 971 2 596 8400
ms-us@c-a-m.com England, UK Malaysia ms-uk@c-a-m.com
Tel 44 1243 826741 Tel 603 7954 0145