Bs Punching Shear PDF
Bs Punching Shear PDF
Bs Punching Shear PDF
0.0024bh if As 0.0013bh if
(BS 3.12.5.3)
In addition, an upper limit on both the tension reinforcement and compression reinforcement has been imposed to be 0.04 times the gross cross-sectional area (BS 3.12.6.1).
rectangular area with the sides parallel to the sides of the columns or the point loads (BS 3.7.7.1). Figure 4-4 shows the auto punching perimeters considered by SAFE for the various column shapes. The column location (i.e., interior, edge, corner) and the punching perimeter may be overwritten using the Punching Check Overwrites.
1.5d
1.5d
1.5d
Interior Column
1.5d
Edge Column
Corner Column
1.5d
1.5d
Circular Column
T-Shape Column
L-Shape Column
(BS 3.4.5.8)
4 - 22
Slab Design
f k2 = cu , 1 k2 25
m = 1.25
40 25
100 As 3 bd
1 4
400 d
(BS 3.4.5.4)
v min(0.8
f cu , 5MPa)
(BS 3.7.6.4)
fcu , 4 MPa)
Veff ud
, where
(BS 3.7.7.3)
x and y are the length of the side of the critical section parallel to the axis of bending Mx and My are the design moments transmitted from the slab to the column at the connection V is the total punching shear force f is a factor to consider the eccentricity of punching shear force and is taken as:
1.00 f = 1.25 1.25 for interior columns for edge columns for corner columns (BS 3.7.6.2, 3.7.6.3)
The ratio of the maximum shear stress and the concrete punching shear stress capacity is reported as the punching shear capacity ratio by SAFE.
4 - 24
Slab Design
Given v, vc, and vmax, the required shear reinforcement is calculated as follows (BS 3.7.7.5).
If v 1.6vc
(BS 3.7.7.5)
If v exceeds the maximum permitted value of vmax, the concrete section should be increased in size.
Slab Design
4 - 25
Free edge
Iy
gx
gy
s0 d 2
s0
Iy
s0
Iy
Free edge
y
Ix
x
Critical section centroid
Free edge
Ix
Interior Column
Edge Column
Corner Column
Figure 4-5 Typical arrangement of shear studs and critical sections outside shear-reinforced zone
4 - 26
Slab Design