Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Bs Punching Shear PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Chapter 4 - Design for BS 8110-97

4.6.1.2 Design Flexural Reinforcement for the Strip


The reinforcement computation for each slab design strip, given the bending moment, is identical to the design of rectangular beam sections described earlier (or to the flanged beam if the slab is ribbed). In some cases, at a given design section in a design strip, there may be two or more slab properties across the width of the design strip. In that case, the program automatically designs the tributary width associated with each of the slab properties separately using its tributary bending moment. The reinforcement obtained for each of the tributary widths is summed to obtain the total reinforcement for the full width of the design strip at the considered design section. This is the method used when drop panels are included. Where openings occur, the slab width is adjusted accordingly.

4.6.1.3 Minimum and Maximum Slab Reinforcement


The minimum flexural tension reinforcement required for each direction of a slab is given by the following limits (BS 3.12.5.3, BS Table 3.25) with interpolation for reinforcement of intermediate strength:

0.0024bh if As 0.0013bh if

f y = 250 MPa f y = 500 MPa

(BS 3.12.5.3)

In addition, an upper limit on both the tension reinforcement and compression reinforcement has been imposed to be 0.04 times the gross cross-sectional area (BS 3.12.6.1).

4.6.2 Check for Punching Shear


The algorithm for checking punching shear is detailed in the section entitled Slab Punching Shear Check in the Key Features and Terminology manual. Only the code specific items are described in the following subsections.

4.6.2.1 Critical Section for Punching Shear


The punching shear is checked at the face of the column (BS 3.7.6.4) and at a critical section at a distance of 1.5d from the face of the support (BS 3.7.7.6). For rectangular columns and concentrated loads, the critical area is taken as a
Slab Design 4 - 21

SAFE Reinforced Concrete Design

rectangular area with the sides parallel to the sides of the columns or the point loads (BS 3.7.7.1). Figure 4-4 shows the auto punching perimeters considered by SAFE for the various column shapes. The column location (i.e., interior, edge, corner) and the punching perimeter may be overwritten using the Punching Check Overwrites.
1.5d

1.5d

1.5d

Interior Column
1.5d

Edge Column

Corner Column

1.5d

1.5d

Circular Column

T-Shape Column

L-Shape Column

Figure 4-4 Punching Shear Perimeters

4.6.2.2 Determine Concrete Capacity


The concrete punching shear factored strength is taken as (BS 3.7.7.4, 3.7.7.6):
1 1

0.79k1k 2 100 As 3 400 vc = m bd d

(BS 3.4.5.4, Table 3.8)

k1 is the enhancement factor for support compression, and is conservatively taken as 1

(BS 3.4.5.8)

4 - 22

Slab Design

Chapter 4 - Design for BS 8110-97


1

f k2 = cu , 1 k2 25
m = 1.25

40 25

(BS 3.4.5.4, Table 3.8) (BS 3.4.5.2)

However, the following limitations also apply: 0.15

100 As 3 bd
1 4

(BS 3.4.5.4, Table 3.8)

400 d

0.67 (unreinforced) or 1 (reinforced)

(BS 3.4.5.4)

v min(0.8

f cu , 5MPa)

(BS 3.7.6.4)

For light-weight concrete, vmax is defined as: v min(0.63

fcu , 4 MPa)

(BS 8110-2:1985 5.4) (BS 3.4.5.4)

fcu 40 MPa (for calculation purpose only)

As = area of tension reinforcement, which is taken as zero in the current implementation.

4.6.2.3 Determination of Capacity Ratio


Given the punching shear force and the fractions of moments transferred by eccentricity of shear about the two axes, the nominal design shear stress, v, is calculated as: v=

Veff ud

, where

(BS 3.7.7.3)

1.5M y 1.5 M x V =V f + + eff Vx Vy

(BS 3.7.6.2, 3.7.6.3)

u is the perimeter of the critical section


Slab Design 4 - 23

SAFE Reinforced Concrete Design

x and y are the length of the side of the critical section parallel to the axis of bending Mx and My are the design moments transmitted from the slab to the column at the connection V is the total punching shear force f is a factor to consider the eccentricity of punching shear force and is taken as:
1.00 f = 1.25 1.25 for interior columns for edge columns for corner columns (BS 3.7.6.2, 3.7.6.3)

The ratio of the maximum shear stress and the concrete punching shear stress capacity is reported as the punching shear capacity ratio by SAFE.

4.6.3 Design Punching Shear Reinforcement


The use of shear studs as shear reinforcement in slabs is permitted, provided that the effective depth of the slab is greater than or equal to 200 mm (BS 3.7.7.5). If the slab thickness does not meet these requirements, the punching shear reinforcement is not designed and the slab thickness should be increased by the user. The algorithm for designing the required punching shear reinforcement is used when the punching shear capacity ratio exceeds unity. The Critical Section for Punching Shear and Transfer of Unbalanced Moment as described in the earlier sections remain unchanged. The design of punching shear reinforcement is carried out as explained in the subsections that follow.

4.6.3.1 Determine Concrete Shear Capacity


The concrete punching shear stress capacity of a section with punching shear reinforcement is as previously determined for the punching check.

4 - 24

Slab Design

Chapter 4 - Design for BS 8110-97

4.6.3.2 Determine Required Shear Reinforcement


The shear stress is limited to a maximum of: vmax = 2vc (BS 3.7.7.5)

Given v, vc, and vmax, the required shear reinforcement is calculated as follows (BS 3.7.7.5).
If v 1.6vc

0.4ud Av ( v - vc ) ud = , s 0.87 f yv 0.87 f yv


If 1.6vc v < 2.0vc

(BS 3.7.7.5)

0.4ud Av 5 ( 0.7v - vc ) ud = , s 0.87 f yv 0.87 f yv


If v > vmax, a failure condition is declared.

(BS 3.7.7.5) (BS 3.7.7.5)

If v exceeds the maximum permitted value of vmax, the concrete section should be increased in size.

4.6.3.3 Determine Reinforcement Arrangement


Punching shear reinforcement in the vicinity of rectangular columns should be arranged on peripheral lines, i.e., lines running parallel to and at constant distances from the sides of the column. Figure 4-5 shows a typical arrangement of shear reinforcement in the vicinity of a rectangular interior, edge, and corner column. The distance between the column face and the first line of shear reinforcement shall not exceed d/2. The spacing between adjacent shear reinforcement in the first line (perimeter) of shear reinforcement shall not exceed 1.5d measured in a direction parallel to the column face (BS 3.7.7.6). Punching shear reinforcement is most effective near column corners where there are concentrations of shear stress. Therefore, the minimum number of lines of shear reinforcement is 4, 6, and 8, for corner, edge, and interior columns respectively.

Slab Design

4 - 25

SAFE Reinforced Concrete Design

Typical Studrail (only first and last studs shown)

Outermost peripheral line of studs


d 2
gx x

Outermost peripheral line of studs


d 2

Free edge

Iy
gx

gy
s0 d 2

s0

Iy

s0

Iy

Critical section centroid


y Ix

Free edge

y
Ix

x
Critical section centroid

Free edge
Ix

Interior Column

Edge Column

Corner Column

Figure 4-5 Typical arrangement of shear studs and critical sections outside shear-reinforced zone

4.6.3.4 Determine Reinforcement Diameter, Height, and Spacing


The punching shear reinforcement is most effective when the anchorage is close to the top and bottom surfaces of the slab. The cover of anchors should not be less than the minimum cover specified in BS 3.3 plus half of the diameter of the flexural reinforcement. Punching shear reinforcement in the form of shear studs is generally available in 10, 12, 14, 16, and 20 millimeter diameter. When specifying shear studs, the distance, so, between the column face and the first peripheral line of shear studs should not be smaller than 0.5d. The spacing between adjacent shear studs, g, at the first peripheral line of studs shall not exceed 1.5d. The limits of so and the spacing, s, between the peripheral lines are specified as: so 0.5d s 0.75d g 1.5d (BS 3.7.7.6) (BS 3.7.7.6) (BS 3.7.7.6)

4 - 26

Slab Design