Axial Piston Pump Series PV: Variable Displacement zp03
Axial Piston Pump Series PV: Variable Displacement zp03
Catalogue HY30-3243/UK
Catalogue HY30-3243/UK
Introduction......................................................................................................4 Characteristics.................................................................................................5 Ordering Code.................................................................................................6 Noise Levels....................................................................................................8 Efciency and Case Drain Flows.....................................................................9 Dimensions....................................................................................................12 Mountingkits..................................................................................................20 Pump combinations Thru Drive, Shaft Load Limitations......................................................21 Compensators Compensators Dimensions.................................................................22 Pressure Compensators.....................................................................23 Load-Sensing Compensators.............................................................24 Power Compensators..........................................................................25 Power Compensators, Diagrams........................................................26 Electrohydraulic p-Q Control...............................................................27 Electronic Module PQDXXA (digital)...................................................28 General Installation Information.....................................................................29
Catalogue HY30-3243/UK
Introduction
Pump with Standard Pressure Compensator, code F*S
PF
PM
L L
P1 P1
A A
PM
L L
P1
P1
A A
p
S L
= included
= included
With thru drive for single and multiple pumps Swash plate type for open circuit
Technical Features Mounting interface according to VDMA-standards sheet 24560 part 1 Standard: 4-hole ange ISO 3019/2 (metric) Large servo piston with strong bias spring achieves fast response; e.g. for PV042 upstroke < 75 ms downstroke < 45 ms Note: Follow installation instructions. Reduced pressure peaks due to active decompression of system at downstroke Also at low system pressure reliable compensator operation. Lowest compensating pressure 12-15 bar 9 piston and precompression technology (precompression volume) result in unbeaten low outlet ow pulsation. Rigid and FEM-optimized body design for lowest noise level Complete compensator program Thru drive for 100% nominal torque
PP UQ PM P L L P1 P1 A A PL Q PM P L L P1
U
Q P1
s
A A UQ
p p S L = included S L
= included
Catalogue HY30-3243/UK
Characteristics
Technical data
Displacement Operating pressures Outlet Inlet min. max. Minimum speed [cm3/rev] from 16 to 270
nominal pressure pN 350 max. pressure pmax. 420 1) drain port 2 2) 0.8 (absolute) 16
Pump with Standard Pressure Comp. Pump with Power Comp.
Mounting interface 4-hole ange ISO 3019/2 Installation drain port as high as possible
1) 2)
Combination PV/PV
Combination PV/PGP
Selection table
Model PV016 Max. displacement [cm3/rev] Output ow at 1500 min-1 [l/min] Input power at Max speed * 1500 min-1 and 350 bar [kW] [min-1] 15.5 19.5 3000 0.0017 19 Moment of inertia [kgm] Weight [kg]
16 24 30
34.5 22.5 94.5 120 138 61.5 2800 78 2500 89.5 2300 136 2400 0.030 175 2200 1800 0.098 90 172 0.018 60
PV270 270
405 263
* The maximum speed ratings are shown for an inlet pressure of 1 bar (absolute) and for a uid viscosity of = 30 mm/s.
Catalogue HY30-3243/UK
Ordering Code
PV
Variation 2nd Axial piston Size Threads pump and pump variable displacement displacement high pressure Rotation Mounting version code Thru drive Compensator Pump Compensator Design series:
(not required for order)
Seals Code N V E W P S
Code
016 020 023 063 080 092 140 180 270
Displacement 16 cm/rev 20 cm/rev 23 cm/rev 63 cm/rev 80 cm/rev 92 cm/rev 140 cm/rev 180 cm/rev 270 cm/rev
1 2 3 4
Single pump, no 2nd pump and coupling PV140 or PV180 mounted PV or PVM pump mounted Gear pump series PGP mounted 2nd pump with full model
7) Specify
code
Code 1
9
2)
For order specify displacement. Mounting interface 4-hole ange 4-hole ange 4-hole ange 4-hole ange 4-hole ange 4-hole ange Shaft Cylindric, key Splined, SAE Cylindric, key Splined, SAE Cylindric, key Splined, DIN 5480
Y8) A B C9) D10) E11) G12) H J K9) L10) M11)
Code
3)
Code
4)
Port 4)
Threads5)
1 BSPP Metric 3 UNF UNC 46) BSPP Metr. M14 7 ISO 6149 UNC 8 ISO 6149 Metric1)
for PV016 - PV023 for PV032 and larger for PV063 and larger for PV270 for PV016 - PV092
Drain, gauge and ushing ports mounting and connecting threads 6) For PV063-PV180 only: pressure port 1 1/4 with 4 x M14 instead of 4 x M12
5) All
Catalogue HY30-3243/UK
Ordering Code
PV
Compensator Pump Compensator Design series:
not required for order
Standard Pressure Compensator Code Compensator options 0 0 1 No compensator 1 0 0 With coverplate, no control function F D S 10 - 140 bar, spindle + lock nut F H S 40 - 210 bar, spindle + lock nut F W S 70 - 350 bar, spindle + lock nut Remote Compensator options F R Remote pressure compensator F S Variation R, for quick unload valve F F Load-Sensing compensator Two valve load-sensing compensator F T Variations for Remote Compensator C External pressure pilot 13) 1 NG6/D03 interface top side 2 Like 1 but with ext. pilot port 15) P Pilot valve PVAC1P* mounted D Proportional pilot valve type PVACPP* mounted L Pilot valve with DIN lock mounted Accessory mounted 14) Z Code Power compensator Displacement Compensator option Nom. torque [Nm]
Electrohydraulic compensator Code Compensator option Pilot pressure supply F Standard (internal), no shuttle valve U Elbow manifold, compensator horizontal 16) Function P Proportional displacement control Variation V Standard, no pressure compensation R G D Z S T Remote pressure comp. NG6 interface Variation R, Pressure sensor and proportional pilot valve mounted for pressure resp. power control Variation R, Proportional pilot valve PVACPP* mounted Variation R, accessories mounted 14) Remote pressure comp., NG6 interface top side, for quick unload valve Variation S, pressure sensor and proportional pilot valve mounted for pressure resp. power control
Remote pressure comp., NG6 interface top P side, for preload and quick unload manifold E
16) not
016 063 140 180 270 Nom. power [kW] 023 092 at 1500 min-1
Variation P, pressure sensor and proportional pilot valve mounted for pressure resp. power control
B x 3 19.5 C x 4 26 D x 5.5 36 E x 7.5 49 G x x 11 71 H x x 15 97 K x x x 18.5 120 M x x x 22 142 S x x x 30 195 T x x x x 37 240 U x x x x 45 290 W x x x x 55 355 Y x x x 75 485 Z x x x 90 585 2 x x 110 715 3 x 132 850 Function L x x x x x C x x x x x Variation A B x x x x x x x x x x NG6 interface top side No pressure compensation Adjustable pressure compensation Proportional pilot valve PVACPP* mounted Accessories mounted 14)
13) Not
for *UPV
Note Compensator differential p is to be adjusted: Remote pressure comp., power comp. 15 1 bar (Codes FR*, FT*, *L*, *C*, FPR, FPD, FPZ, FPG) With quick unload manifold 12 1 bar (Codes FS*, FPS, FPT, FPP, FPE) Load-Sensing comp. (not power comp.) 10 1 bar (Codes FF*) The ordering code PVACPP* correspond to the DSAE1007P07*
C x x x x x D x x x x x Z x x x x x
for two-valve-compensator
specify on order with full model code. 15) Only for Codes *FR* and *FT*
Catalogue HY30-3243/UK
Noise Levels
PV016 - PV023
PV063 - PV092
PV270
PV140
Typical sound level for single pumps, measured in unechoic chamber according to DIN 45 635, part 1 and 26. Microphone distance 1m; speed: n = 1500 min-1.
All data measured with mineral oil viscosity 30 mm/s (cSt) at 50C.
Catalogue HY30-3243/UK
vol. efficienc y
20
overall efficiency
80
15
12
ll fu at r we po w flo
60
10
8
ut inp
40
20
t input power a
0 0 0 100
ad deadhe
300 Pressure [bar] 0
200
PV020
Output flow [l/min] Input power [kW]
30 25
output flow, vo l. efficiency
100
overall efficiency
25
20
100
24
20
80
18
15
low ll f u tf ra
60
12
10
we po t u inp
40
5
inpu t power at d
20
d ea dhea
300 Pressure [bar] 0
100
200
PV023
Output flow [l/min] Input power [kW]
40 25 vo l. efficiency
100
overall efficiency
32
20
output flow
80
24
15
16
10
w lo ll f u tf ra e w po ut p in
60
40
5
inpu t power at d
20
d ea dhea
300 Pressure [bar] 0
100
200
Catalogue HY30-3243/UK
output flow
56
vol. efficiency
overall efficiency
80
80
60
42
40
28
t pu in
r we po
at
ll f fu
w lo
60
40
20
14
d a dh ea er at de inp ut p o w
0 100 200 300 Pressure [bar]
20
PV080
Output flow [l/min] Input power [kW]
120 80
output flow, vol. efficiency
96
64
overall efficiency
100
100
70
100
80
72
48
48
32
t pu in
at er w po
ll f fu
w lo
60
40
24
16
h ead r at dea d input powe
20
100
200
PV092
Output flow [l/min] Input power [kW]
150 100
output flow vol. efficiency
100
120
80
cy overall efficien
80
90
60
60
40
w lo ll f u tf ra e w po ut p in
60
40
30
20
20
10
Catalogue HY30-3243/UK
200
120
output flow
80
150
90
100
60
pu in
w lo lf ul f at er w o tp
60
40
50
30
20
a d he i np ut power at de
0 0 0 100 200
ad
0
PV180
Output flow [l/min] Input power [kW]
300 175
vol. efficiency output flow
100
overall e ffic
iency
240
140
80
180
105
120
70
tp pu in
l ul tf a er ow
w flo
60
40
60
35
20
ad he ad in pu t power at de
0 0 0 100 200 300 Pressure [bar]
PV270
Output flow [l/min] Input power [kW]
500 250
250
150
100
400
200
100
80
100
50
in
200
100
pu t
po we r
at f
300
150
ul lf
60
40
20
11
Catalogue HY30-3243/UK
Dimensions
PV016 - 023, metric version
mounting hole for horse power compensator pilot or displacement feedback LVDT
94 120
16.5
drain port L1, dimensions see L2
13 32
9 10
89 55 15
X key 8 x 7 x 40 DIN 6885
12 28-0.25
thread M10 - 22 deep
48
125
22
flushing port L3; G 3/8 optional M 18 x 1.5; ISO 6149-1 (threads options 7 and 8) oder 3/4 - 16 UNF (threads option 3) The pump shown above has mounting option K and thru drive option T (prepared for thru drive).
58.7
32 30.2 23.8
4 x M10, 18 deep optional 7/16 - 14 UNC - 2B (threads options 3 and 7) 4 x M10, 18 deep optional 3/8 - 16 UNC - 2B (threads options 3 and 7)
100h8
mounting option L splined shaft W 25 x 1.5 x 15 x 8f DIN 5480
50.8
19
Outlet: flange according ISO 6162 DN 19; PN 400 bar
43
For further information about anges see catalogue No. 4039/UK Pressure Hydraulic Flanges (on request). Shown is a clockwise rotating pump. Counter clockwise rotating pumps have inlet, outlet and gauge ports reversed.
12
Catalogue HY30-3243/UK
Dimensions
PV016 - 023, SAE version and thru drive
13.5
89.8 44.9
9.4 8 42 50
44.9 89.8
101.6-0.05
mounting option E splined shaft 15T 16/32 DP, flat root, side fit ANSI B92.1
46
E A G C
Thru shaft adaptors are available with the following dimensions: A B 10 10 10.5 10 10 10.5 C 85 103 125 - - - D - - - - - 89.8 E M8 M8 M10 - - M12 F 100 109 - 82 106 - G M8 M10 M8 M10 63 80 100 50.8 82.55 101.6
Dimension H and available couplings see page 24. At threads options 3 and 7 the dimensions E and G are UNC - 2B threads.
13
Catalogue HY30-3243/UK
Dimensions
PV063 - 092, metric version
For further information about anges see catalogue No. 4039/UK Pressure Hydraulic Flanges (on request). Shown is a clockwise rotating pump. Counter clockwise rotating pumps have inlet, outlet and gauge ports reversed.
14
Catalogue HY30-3243/UK
Dimensions
PV063 - 092, SAE version and thru drive version
C G
287
B K
H D F
Thru shaft adaptors are available with the following dimensions: A B C D E M8 M8 M10 M12 M16 - M12 M12 M16 F 100 109 140 180 - 106 146 181 - G M8 M10 M12 M16 - M10 M12 M16 - K 58 58 58 58 58 58 58 58 78 L 326 326 326 326 326 326 326 326 346 63 80 100 125 160 82.55 101.6 127 152.4 10 85 - 10 103 - 12 125 - 12 160 - 12 200 - 10 - - 12 - 89.8 14 - 114.5 14 - 161.6
Dimension H and available couplings see page 24. At threads options 3 and 7 the dimensions E and G are UNC - 2B threads.
15
Catalogue HY30-3243/UK
Dimensions
PV140 - 180, metric version
mounting hole for horse power compensator pilot or LVDT for displacement feedback
drain port L2; G1 optional M 33 x 2; ISO 6149-1 (threads options 7 and 8) 204 or 1 5/16 - 12 UNF (threads option 3) 158 50k6 35 35 160h8 200 145
gage port M; G1/4 optional M 12 x 1.5; ISO 6149-1 (threads options 7 and 8) oder 7/16 - 20 UNF (threads option 3)
233 pressure port: 295 suction port: 305 Inlet: flange according ISO 6162 DN 64; PN 160 bar 88.9 64 4 x M12, 20 deep optional 1/2 - 13 UNC - 2B (threads options 3 and 7) 4 x M12, 20 deep optional 1/2 - 13 UNC - 2B (threads options 3 and 7) or threads option 4 (M14, 22 deep) 32 Outlet: flange according ISO 6162 DN 32; PN 400 bar 78 160h8
40 flushing port L3; G 3/4 optional M 27 x 2; ISO 6149-1 (threads options 7 and 8) oder 1 1/16 - 12 UNF (threads option 3) The pump shown above has mounting option K and thru drive option T (prepared for thru drive).
50.8 31.8
66.6
For further information about anges see catalogue No. 4039/UK Pressure Hydraulic Flanges (on request). Shown is a clockwise rotating pump. Counter clockwise rotating pumps have inlet, outlet and gauge ports reversed.
16
Catalogue HY30-3243/UK
Dimensions
PV140 - 180, SAE version and thru drive version
E A C
B 350 415 97
H F D
Thru shaft adaptors are available with the following dimensions: A B C D - - - - - 89.8 114.5 161.6 E M8 M10 M12 M16 - M12 M12 M16 F 109 140 180 - 106 146 181 - G M10 M12 M16 M10 M12 M16 80 100 125 160 82.55 101.6 127 152.4 10 103 12 125 12 160 12 200 10 - 12 - 14 - 14 -
Dimension H and available couplings see page 24. At threads options 3 and 7 the dimensions E and G are UNC - 2B threads.
17
Catalogue HY30-3243/UK
Dimensions
PV 270, metric version
For further information about anges see catalogue No. 4039/UK Pressure Hydraulic Flanges (on request). Shown is a clockwise rotating pump. Counter clockwise rotating pumps have inlet, outlet and gauge ports reversed.
18
Catalogue HY30-3243/UK
Dimensions
PV 270, SAE version and thru drive version
E A C G
B 472.5 531.5 97 D F
Thru shaft adaptors are available with the following dimensions: A B C D E F G M10 M12 M16 M20 M10 M12 M16 M20 80 100 125 160 200 82.55 101.6 127 152.4 165.1 8.5 103 - 10.5 125 - 10.5 160 - 13.5 200 - 13.5 250 - 8 - - 11 - 89.8 13.5 - 114.5 13.5 - 161.6 17 - 224.5 M8 109 M10 140 M12 180 M16 224 M20 - - 106 M12 146 M12 181 M16 229 M20 -
Dimension H and available couplings see page 24. At threads options 3 and 7 the dimensions E and G are UNC - 2B threads.
19
Catalogue HY30-3243/UK
Kits
MK
Mounting kit
PV
Axial piston pump series PV
BG
Size Second pump Thread Seals Design series
Code 1 2 3 4 5
Pump size Code T Y A B C D E G H J K L M Second pump, SAE Prepared for thru drive option (plugged) SAE AA, diameter 50.8 mm SAE A, diameter 82.55 mm SAE B, diameter 101.6 mm SAE C, diameter 127,mm SAE D, diameter 152.4 mm SAE E, diameter 165.1 mm Second pump, metric Diameter 63 mm Diameter 80 mm Diameter 100 mm Diameter 125 mm Diameter 160 mm Diameter 200 mm
Code N V E
Pump size 1: PV016 - PV023 Pump size 2: PV032 - PV046 Pump size 3: PV063 - PV092 Pump size 4: PV140 - PV180 Pump size 5: PV270
Code M S
Kit contains positions 30, 69, 84, 85 and 87, see drawing below.
MK
Mounting kit
PV
Axial piston pump series PV
BG
Size
K
Coupling Design series
Code 1 2 3 4 5
Pump size
Pump size 1: PV016 - PV023 Pump size 2: PV032 - PV046 Pump size 3: PV063 - PV092 Pump size 4: PV140 - PV180 Pump size 5: PV270
Code
Coupling for metric, splined shaft DIN 5480 N25 x 1.5 x 15 N32 x 1.5 x 20 N40 x 1.5 x 25 N50 x 2 x 24 N60 x 2 x 28 Coupling for SAE splined shaft at root, side t 9T 16/32 11T 16/32 13T 16/32 15T 16/32 14T 12/24 17T 12/24 13T 8/16 15T 8/16 Coupling + adaptor for keyed shaft Diameter 12 mm Diameter 16 mm Diameter 18 mm
SAE, splined
01 02 03 04 05
85 87 92
69
metric, splined
20 21 22
front pump 30 84 91
second pump
20
Catalogue HY30-3243/UK
Important notice The max. allowable torque of the individual shaft must not be exceeded. For 2-pump combinations there is no problem because PV series offers 100% thru torque. For 3-pump combinations (and more) the limit torque could be reached or exceeded. Therefore it is necessary to calculate the torque factor and compare it with the allowed torque limit factor in the table. Required: calculated torque factor < torque limit factor
Pump Shaft Torque limit factor
To make the necessary calculations easier and more user friendly it is not required to calculate actual torque requirements in Nm and compare them with the shaft limitations. The table on the right shows limit factors that include material specication, safety factors and conversion factors. The total torque factor is represented by the sum of the individual torque factors of all pumps in the complete pump combination. Total torque factor of the combination = sum of individual torque factors of all pumps The torque factor of each individual pump is calculated by multiplying the max. operating pressure p of the pump (in bar) with the max. displacement Vg of the pump (in cm/rev). Torque factor of any pump = p x Vg
D 17700 E 17700 K 17700 L 20130 D E K L D E F G K L 77280 72450 67620 83720 118400 158760 78750 97650 113400 157500
21
Catalogue HY30-3243/UK
Compensators Dimensions
Remote pressure compensator, code FRC Load-Sensing compensator, code FFC
All control ports G1/4 optional M 12 x 1.5; ISO 6149-1 (threads options 7 and 8) or 7/16-20 UNF (threads option 3)
31
42.5
2 x M5 - 10deep in pump body (see note above) load-sensing-port PF (code FF1) (plugged for code FR1 )
40
24
Proportional p-Q-compensator, code FPR (for code FPV lower valve only without interface)
interface NG6, CETOP 03
80
40
40 49 50
34
22
Catalogue HY30-3243/UK
Pressure Compensators
Standard pressure compensator, code F*S The standard pressure compensator adjusts the pump displacement according to the actual need of the system in order to keep the pressure constant. As long as the system pressure at outlet port P is lower than the set pressure (set as spring preload of the compensator spring) the working port A of the compensator valve is connected to the case drain and the piston area is unloaded. Bias spring and system pressure on the annulus area keep the pump at full displacement. When the system pressure reaches the set pressure the compensator valve spool connects port P1 to A and builds up a pressure at the servo piston resulting in a downstroking of the pump. The displacement of the pump is controlled in order to match the ow requirement of the system. Remote pressure compensator, code FRC While at the standard pressure compensator the pressure is set directly at the compensator spring, the setting of the remote pressure compensator can be achieved by any suitable pilot pressure valve connected to pilot port PP. The pilot ow supply is internal through the valve spool. The pilot ow is 1 - 1.5 l/min.The pilot valve can be installed remote from the pump in some distance. That allows pressure setting e. g. from the control panel of the machine. The remote pressure compensator typically responds faster and more precisely than the standard pressure compensator and is able to solve instability problems that may occur with a standard pressure compensator in critical applications. The pressure pilot valve can also be electronically controlled (proportional pressure valve) or combined with a directional control valve for low pressure standby operation. Remote pressure compensator, code FR1 Version FR1 of the remote pressure compensator provides on its top side an interface NG6, DIN 24340 (CETOP 03 at RP35H, NFPA D03). This interface allows a direct mounting of a pilot valve. Beside manual or electrohydraulic operated valves it is also possible to mount complete multiple pressure circuits directly on the compensator body. Parker offers a variety of these compensator accessories ready to install. All remote pressure compensators have a factory setting of 15 bar differential pressure. With this setting, the controlled pressure at the pump outlet is higher than the pressure controlled by the pilot valve.
PM
L L
P1 P1
A A
PP L L P1 P1 A A
PM P
p
= included
T T
P P Q
PM P
L L
P1 P1
A A
Remote pressure compensator with interface NG6 for accessories code FR1
p = included
23
Catalogue HY30-3243/UK
Load-Sensing Compensators
Load-Sensing compensator, code FFC The load-sensing compensator has an external pilot pressure supply. Factory setting for the differential pressure is 10 bar. The input signal to the compensator is the differential pressure at a main stream resistor. A load-sensing compensator represents mainly a ow control for the pump output ow, because the compensator keeps the pressure drop at the main stream resistor constant. A variable input speed or a varying load(-pressure) has consequently no inuence on the output ow of the pump and the speed of the actuator. By adding a pilot orice ( 0.8 mm) and a pressure pilot valve pressure compensation can be added to the ow control function. See the circuit diagram below, left.
PF
PM P
L L
P1 P1
A A
0.8 T T PF P P PF Q
PM P
L L
P1 P1
A A
PM P
L L
P1 P1
A A
Load-Sensing compensator code FFC external orice and pressure pilot valve
p = included
Shown above is load-sensing compensator, code FF1 with an NG6 interface on top of the control valve. That allows direct mounting of a pilot valve for pressure compensation. This version includes the pilot orice. Due to the interaction of ow and pressure compensation this package has not the ideal control characteristic. The deviation is caused by the pilot valves characteristic.
T T
P P
PF
PM P
L L
P1 P1
A A
p S L = included
24
Catalogue HY30-3243/UK
Power Compensators
Hydraulic-mechanical power compensator The hydraulic-mechanical power compensator consists of a modied remote pressure compensator (Code *L*) or of a modied load-sensing compensator (Code *C*) and a pilot valve. This pilot valve is integrated into the pump and is adjusted by a cam sleeve. The cam sleeve has a contour that is designed and machined for the individual displacement and the nominal power setting. At a large displacement the opening pressure (given by the cam sleeve diameter) is lower than at small displacements. This makes the pump compensate along a constant power (torque) curve (see diagrams on opposite page). For all nominal powers of standard electrical motors Parker offers a dedicated cam sleeve. The exchange of this cam sleeve (e. g.: to change power setting) can easily be done without disassembly of the pump. On top of that an adjustment of the power setting can be done within certain limits by adjusting the preload of the pilot control cartridge spring . That allows an adjustment of a constant power setting for other than the nominal speeds (1500 min-1) or for other powers.
Power comp., pilot ow internal pressure pilot valve included code *LC
Power comp., pilot ow external for load-sensing, pilot valve included code *CC
25
Catalogue HY30-3243/UK
The diagrams shown are only valid for the following working conditions: Speed : n = 1500 rev/min : t = 50C Temperature Fluid : HLP, ISO VG46 Viscosity : = 46 mm2/s at 40C
26
Catalogue HY30-3243/UK
UQ PM P L L P1 Us P1 A A
UQ
= included
UP
T T
P P
UQ
Q L L P1 Us P1 A A UQ UP
PM P
= included
UP
T Up T
P pP P
DP DB1 UQ p1 PM P L L P1 P1 A A DB2
Us
UQ UP
= included
27
Catalogue HY30-3243/UK
Features Digital control circuit Parameter setting via RS-232 interface All settings (ramps, MIN/MAX, control parameters) can be stored digitally and recalled from a PC to duplicate settings to other modules Ramp time up to 60 seconds Compatible to the relevant european EMC specications Easy to use PC based setup software Covers all displacements from 16 to 270 cm/rev
Covers all functions: displacement control, displacement control with open loop pressure control, displacement control with closed loop pressure control and displacement control with closed loop pressure control and electronic power limitation.
Ordering code
PQD
Digital control module for p/Q control
XX
For all frame sizes series PV
A
Version A
Z00
Option Please order the interface cable to PC separately. Ordering code: PQDXXA-KABEL
Technical data
Mounting style Snap-on mounting for EN50022 rail Body material Polycarbonate Inammation class V2...V0 acc. UL 94 Mounting position any Env. temperature range [C] -20...+55 Protection class IP 20 acc. DIN 40 050 Weight [g] 160 Duty ratio [%] 100 Supply voltage [V] 18...30VDC, ripple <5% eff. [A] 22 for 0.2 ms Rush in current Current consumption [A] < 4 for p/Q control ; < 2 for Q-control Resolution [%] 0.025 (power 0.1) Interface RS232C, 9600 baud, 3.5 mm cinch EMC EN 50 081-2, EN 50 082-2 Connctors Screw terminals 0.2...2.5 mm, plug in style Cables [mm] 1.5 (AWG 16) overall braid shield, for supply and solenoid connection 0.5 mm (AWG 20) overall braid shield, for sensor and command signal connections Max. cable length [m] 50 For programming the module via PC, an interface cable is needed, please order separately.
28
Catalogue HY30-3243/UK
Diagrams
Response times
Size PV046 TA [ms] 70 TR [ms] 70
29
Catalogue HY30-3243/UK
Notes
30
Catalogue HY30-3243/UK
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the nal selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specications, designs, availability and pricing, are subject to change by Parker Hannin Corporation and its subsidiaries at any time without notice.
Offer of Sale
31
International
Italy
Corsico (MI) Tel: +39 02 45 19 21 Fax: +39 02 4 47 93 40 Oldenzaal Tel: +31 (0)541 585000 Fax: +31 (0)541 585459
Austria
Australia
Castle Hill Tel: +61 (0)2-9634 7777 Fax: +61 (0)2-9899 6184
Austria
The Netherlands
Canada
Belgium
Norway
Nivelles Tel: +32 (0)67 280 900 Fax: +32 (0)67 280 999
China
Czech Republic
Poland
Klecany Tel: +420 284 083 111 Fax: +420 284 083 112 Ballerup Tel: +45 4356 0400 Fax: +45 4373 3107
Denmark
Portugal
Leca da Palmeira Tel: +351 22 9997 360 Fax: +351 22 9961 527
Mumbai Tel: +91 22 5613 7081/82-85 Fax: +91 22 2768 6841/6618 Tokyo Tel: +(81) 3 6408 3900 Fax: +(81) 3 5449 7201
India
Finland
Slovakia Spain
Ref. Czech Republic Madrid Tel: +34 91 675 73 00 Fax: +34 91 675 77 11
Japan
Vantaa Tel: +358 20 753 2500 Fax: +358 20 753 2200 Contamine-sur-Arve Tel: +33 (0)450 25 80 25 Fax: +33 (0)450 25 24 25
France
Sweden
Germany
Kaarst Tel: +49 (0)2131 4016 0 Fax: +49 (0)2131 4016 9199 Dublin Tel: +353 (0)1 293 9999 Fax: +353 (0)1 293 9900
Spnga Tel: +46 (0)8 597 950 00 Fax: +46 (0)8 597 951 10
United Kingdom
Ireland
Warwick Tel: +44 (0)1926 317 878 Fax: +44 (0)1926 317 855
Kempton Park Tel: +27 (0)11-961 0700 Fax: +27 (0)11-392 7213
South Africa
USA
Cleveland (industrial) Tel: +1 216-896-3000 Fax: +1 216-896-4031 Lincolnshire (mobile) Tel: +1 847-821-1500 Fax: +1 847-821-7600
Parker Hannin is the worlds premier supplier of motion and control systems and solutions, with sales and manufacturing facilities throughout the world. For product information and details of your nearest Parker sales ofce, visit us at www.parker.com or call free on 00800 2727 5374.
Catalogue HY30-3243/UK PDF 04/06 Copyright 2006 Parker Hannin Corporation All rights reserved.