f6150sv Ts Us LR
f6150sv Ts Us LR
f6150sv Ts Us LR
and enhanced ratings. There are three distinct models for your specific testing needs. The F6150sv premier model features 12 analog sources and can run in a mixed mode of operation with a combination of analog and sampled values sources.
CONVERTIBLE AMPLIFIERS Current Mode Convertible Source AC Ranges 6 X 0.5, 1.0 A RmS (L-N) 3 X 0.5, 1.0, 2.0 A RmS (L-N) 1 X 1.5, 3.0, 6.0 A RmS (L-N) S1 S2 S3 Convertible Source DC Ranges 6 X 0.354, 0.707 A DC 3 X .354, 0.707, 1.41 A DC 1 X 1.06, 2.12, 4.24 A DC S1 S2 S3 Power 6 X 75VA / 75 W 3 X 150VA / 150 W 1 X 450VA / 450 W S1 S2 S3 Current Transient Mode Convertible Source AC Ranges 6 X 0.75, 1.5 A RmS (L-N) 3 X 0.75, 1.5, 3.0 A RmS (L-N) 1 X 2.25, 4.5, 9.0 A RmS (L-N) S1 S2 S3 Convertible Source DC Ranges 6 X 0.53, 1.06 A DC 3 X 0.53, 1.06, 2.12 A DC 1 X 1.59, 3.18, 6.36 A DC S1 S2 S3 Power 6 X 97.5VA / 97.5 W 3 X 195VA / 195 W 1 X 585VA / 585 W S1 S2 S3 Voltage Mode Convertible Source AC Ranges 6 X 75, 150V RmS (L-N) 3 X 75, 150, 300V RmS (L-N) 1 X 150, 300, 600V RmS (L-L) S1 & S2 Convertible Source DC Ranges 6 X 106, 212V DC 3 X 106, 212, 424V DC 1 X212, 424, 848V DC S1 & S2 Power 6 X 75VA/ 75W 3 X 150VA / 150 W 1 X 300VA / 300 W S1 & S2 ENHANCED CURRENT AMPLIFIERS AC Ranges 6 X 8.75, 17.5, (35)* A RMS (L-N) 3 X 8.75, 17.5, 35,(70)* A RMS (L-N) 1 X 8.75, 17.5, 26.25,52.5, 105, (210)* A RMS (L-N) S1 S2 S3 DC Ranges 6 X 5.83, 11.7, (23.3)* A DC 3 X 5.83, 11.7, 23.3,(46.6)* A DC 1 X 5.83, 11.7, 17.5, 35,70, (140)* A DC S1 S2 S3 Power 6X 87.5VA / 87.5 W; (6 X 131.25VA /131.25 W)* 3 X 175VA / 175 W; (3 X 262.5VA /262.5 W)* 1 X 525VA / 525 W; (1X787.5VA/787.5 W)* S1 S2 S3 Resolution AC Ranges 0.001 A (0.001) A @ 8.75, 17.5, 35 A RMS (0.01) @ (70)* A RMS (0.001) A @ 8.75, 17.5, 26.25 A RMS (0.01) A @ 52.5, 105, (210)* A RMS Resolution DC Ranges (0.001) A @ 5.83 A DC (0.01) A @ 11.6, (23.3)* A DC (0.001) A @ 5.83 A DC (0.01) A @ 11.7, 23.3, (46.6)* A DC (0.001) A @ 5.83 A DC (0.01) A @ 11.7, 23.3, 35, 70, (140)* A DC Resolution AC Ranges 0.01 V 0.01 V 0.01 V Resolution DC Ranges (0.01 V) @ 106V DC (0.1 V) @ 212V DC (0.01 V) @ 106V DC (0.1 V) @ 212, 424V DC 0.1 V DC Resolution AC Ranges 0.0001 A 0.0001 A 0.001 A Resolution DC Ranges 0.0001 A (0.0001 A) @ 0.53, 1.06 A DC (0.001 A) @ 2.12 A DC 0.001 A Resolution AC Ranges 0.0001 A 0.0001 A 0.001 A Resolution DC Ranges 0.0001 A 0.0001 A 0.001 A
sv-SGD
The F6150sv Smart Grid Distribution (SGD) model features 8 analog sources and can run in a mixed mode of operation. It can be used for IEC 61850 Station and Process Bus testing compliant with 9-2LE.
CONVERTIBLE AMPLIFIERS Current Mode Convertible Source AC Ranges 4 X 0.5, 1.0 A RmS (L-N) 4 X 0.5, 1.0 A RmS (L-N) 1 X 1.0, 2.0, 4.0 A RmS (L-N) S1 S2 Convertible Source DC Ranges 4 X 0.354, 0.707 A DC 2 X .354, 0.707, 1.41 A DC 1 X 0.707, 1.41, 2.82 A DC S1 S2 Power 4 X 75VA / 75 W 2 X 150VA / 150 W 1 X 300VA / 300 W S1 S2 Current Transient Mode Convertible Source AC Ranges 4 X 0.75, 1.5 A RmS (L-N) 2 X 0.75, 1.5, 3.0 A RmS (L-N) 1 X 1.5, 3.0, 6.0 A RmS (L-N) S1 S2 Convertible Source DC Ranges 4 X 0.354, 0.707 A DC 2 X .354, 0.707, 1.41 A DC 1 X 0.707, 1.41, 2.82 A dc S1 S2 Power 4 X 97.5VA / 97.5 W 2 X 195VA / 195 W 1 X390VA / 390 W S1 S2 Voltage Mode Convertible Source AC Ranges 4 X 75, 150V RmS (L-N) 2 X 75, 150, 300V RmS (L-N) 1 X 1.5, 3.0, 6.0 A RmS (L-N) S1 & S2 Convertible Source DC Ranges 4 X 106, 212V DC 2 X 106, 212, 424V DC 1 X212, 424, 848V DC S1 & S2 Power 4 X 75VA/ 75W 2 X 150VA / 150 W 1 X 300VA / 300 W S1 & S2 Enhanced Mode AC Ranges 4 X 8.75, 17.5, (35)** A RmS (L-N) 2 X 8.75, 17.5, 35,(70)** A RmS (L-N) 1 X 8.75, 17.5, 35, 70, (140)* A RmS (L-N) S1 S2 DC Ranges 4 X 5.83, 11.7, (23.3)** A DC Power 4X 87.5VA / 87.5 W; (4 X 131.25VA /131.25 W)** 2 X 175VA / 175 W; (2 X 262.5VA /262.5 W)** 1 X 350VA /350W; ( 1X525VA/525 W)** S1 S2 Resolution AC Ranges 0.001 A (0.001) A @ 8.75, 17.5 A RmS (0.01) @ 35, (70)** A RmS (0.001) A @ 8.75, 17.5 A RmS (0.01) A @ 35, 70, (140)** A RmS Resolution DC Ranges (0.001) A @ 5.83 A DC (0.01) A @ 11.6, (23.3)** A DC (0.001) A @ 5.83 A DC (0.01) A @ 11.7, 23.3, (46.7)** A DC (0.001) A @ 5.83 A DC (0.01) A @ 11.7, 23.3, 46.7 (93.3*)* A DC Resolution AC Ranges 0.01 V 0.01 V 0.01 V Resolution DC Ranges (0.01 V) @ 106V DC (0.1 V) @ 212V DC (0.01 V) @ 106V, 212V DC (0.1 V) @ 424V DC 0.1 V DC Resolution AC Ranges 0.0001 A (0.0001 A) @0.75 A RmS (0.001 A) @ 1.5, 3.0 A RmS 0.001 A Resolution DC Ranges 0.0001 A (0.0001 A) @ 0.53 A DC (0.001 A) @ 1.06, 2.12 A DC 0.001 A Resolution AC Ranges 0.0001 A (0.0001 A) @0.5, 1.0 A RmS (0.001 A) @ 2.0 A RmS (0.0001 A) @1.0 A RmS (0.001 A) @ 2.0, 4.0 A RmS Resolution DC Ranges 0.0001 A (0.0001 A) @0.354, 0.707 A DC (0.001 A) @ 1.41 A DC (0.0001 A) @0.707 A DC (0.001 A) @ 1.41, 2.82 A DC
sv-IEC
The F6150sv IEC model has no analog source outputs. It can be used for IEC 61850 Station and Process Bus testing compliant with 9-2LE. Its low level source mode is used to control the F5850 Intellirupter testing interface.
LOW LEVEL SOURCE PARAMETER RANGES Voltage Mode Convertible Amplifier Sources Current Amplifier Sources 6.7 VRmS N/A Current Mode 4.5 VRmS 3.38 VRmS (3.48 VRmS for enhanced ratings) Transient Mode 6.7 VRmS 6.7 VRmS (6.96 VRmS for enhanced ratings)
0.25% of reading 50
Logic Outputs FET (High Speed Electronic) Relay 4 500V peak <10 millisecond pick up /dropout (Breaking cap AC: 2000 VA with Vmax 250V, Imax 8 A) (Breaking cap DC: 50W with Vmax 300 V, Imax 8A) 250 V RMS Variable Output Battery Simulator Range: Resolution: Power: 50/60 Hz Ripple: Accuracy: 6 - 300V DC 0.3V 90 W, 1.5 A max <0.2% of Range < 5%
Analog Input Measurement (AIM) (F6820 Option) 8 external Analog or Recording: Digital Signals Internal Source 12 Sources recording: 250 mV, 2.5V, 25V, Ranges: 250V RMS Bandwidth: DC, 0-5kHz Input Impedance: 150K Max Input 250V RMA AC / 300V Voltage: DC Isolation: Typical: Maximum: Timers Number: Max Recording Time: Accuracy: Resolution: 500V peak channel to channel Accuracy 0.06% 0.15% Timing and Trigger 8 <24 Hours 0.0005% of reading, 50 sec 100 sec
0.1 msec max pickup /dropout Input Impedance: 150K Isolation: 500V peak Paired Inputs Inputs: 3 Pairs (6) 250V RMS Voltage Sense: AC / 300V DC Open Circuit Test 4V DC Voltage: Short Circuit Test >50mA DC Current: 0.1 msec max Response Time: pickup /dropout Input Impedance: Isolation: 150K 500V peak
Metering Functions DC Meter Inputs Input Range: Typical: Guaranteed: AC Sources Typical: <0.02% of metering loads Logic Input As Counters Frequency: Pulse width: 10 kHz >175 sec 0 - 10V DC / 0 - 20mA DC <0.003% <+0.05%
AC Amplitude Accuracy @ 50-60 Hz @ 20 - 30 C Typical 0.02% of reading + .01% of range Guaranteed 0.09% of reading + .04% of range Range
Phase Angle @ 50/60 Hz Accuracy 0.25 Resolution 0.1 Bandwith DC - 3kHz at Full Power
Frequency Range DC, 0.1 Hz - 2.0 kHZ Continuous Full Load Accuracy Typical 0.5 ppm @ 20 - 30 C 1.5 ppm @ 0 - 50 C 10 ppm Resolution 0.001 Hz
Distortion @ 50/60Hz V & I Sources Total Harmonic Distortion (THD) Typical <0.02% Guaranteed <0.1% General Specifications
Enclosure:
High-impact, molded, flame-retardant ABSmeets National Safe Transit Association testing specification No.1A for immunity to severe shock and vibration
IEC 60068-2-2 Dry Heat (+85C storage; + 50C Rating IEC 801-2 I.E.C. performance level Certified by KEMA as being Operating), IEC 60068-2-1 Cold Electrostatic 1 @ 10kV: normal performance IEC61850 GOOSE: compliant with IEC61850 Environmental: (-50C storage; 0C operating), Discharge within specifications. I.E.C. protocol (IEC61850-7-2 IEC 60068-2-30 Damp Heat Immunity: performance level 2 @ 20kV: no and 8-1) (+55C, 6 cycles, 95% humidity), permanent damage. NEMA Enclose Rating Type 1IEC Enclosure IP20 ANSI/IEEE c37.90. The simulator functions as a source during surge IEC61850 withstand capability tests, when Sample Values the ANSI/IEEE specified isolating (Publishing): circuit is interposed between the simulator and the test relay. 105-264V, 47-63 Hz 80 samples per cycles for nominal frequencies 50Hz and 60Hz using GPS time synchronized signals
FCC 47 CFR Part 15 Class A IEC 60068-2-27 Shock (USA), EN55011:1998/A1:1999/ (15g/11ms, half sine) A2:2002 Group 1 Class A Mechanical: IEC 60068-2-6 Vibration EMC Emissions: ISM(EU), AS/NZS CISPR 11:2004 (10-150 Hz, 20m/s2) Class A ISM (Australia), ICES-001 IEC 60068-2-6 Drop Test Issue 3 ISM (Canada) 42lb,19.05kg EN 61000-6-2:2005; Weight: (front cover and strap EMC Immunity: IEC 61000-4-2/3/4/5/6/11 included) Quality Third Party certification to ISO 15 X 9.5 X 18 inches, Assurance Dimensions: Management 9001:2000 38 X 24 X 45.7 cm System: Calibration: Certification traceable to Humidity: N.I.S.T. standards Up to 95% relative humidity, non-condensing
Safety:
Ethernet or USB control to PC, Wi-Fi (802.11 B+G bands, 30 80ft, 9 - 24m) Communication Station bus Ethernet Interfaces interface: two redundant RJ45s at 100MBps (Ethernet, Wi-Fi, EN 61010-1; UL 61010-1; CSA 27.2 Process bus Ethernet USB) # 61010-1 interface: one redundant RJ45 at 1GBPS and MTRJ (optical fiber) at 100 BaseFX
Doble Engineering Company Worldwide Headquarters 85 Walnut Street Watertown, MA 02472 USA tel +1 617 926 4900 fax +1 617 926 0528 www.doble.com
MKT-SL-F6150SVTS-6/13