Series AR712/722 Gas Chromatograph: Analysis of Impurities in Argon

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Series AR712/722 Gas Chromatograph

Analysis of Impurities in Argon

The GOW-MAC Series AR712/722 GC has been engineered and optimized specically for the analysis of trace impurities in argon. Two congurations are available depending upon the impurities being measured. Principle The argon gas passing through the detector is subjected to a high electromagnetic eld. This causes the gas to illuminate. A light dependent resistor (LDR) monitors the resulting luminance. The light intensity is altered as the sample component elutes from the column. The output from the LDR is converted to a mV signal and is measured on a data reduction system. The area count is proportional to the concentration of each component in the sample. Features "" Laminar low volume ow system "" Hands-free operation in auto-mode "" High quality VCR ttings ensure perfect seals "" Mass spec leak tested valve in argon purged housing "" Pre-installed, pre-tested analytical column(s) with chromatogram "" Rapid start-up with factory supplied documentation "" Accuracy of 1% "" Application guaranteed

Applications Specialty gas manufacturers Industrial processes requiring inert argon Semiconductory industry Gas separation plants Nuclear industry Certication of argon purity Air separation plants Specialty gas manufacturers

Sensitivity H2 O2 N2 CH4 CO CO2 < 15 ppb < 75 ppb < 100 ppb < 30 ppb < 200 ppb < 100 ppb

SB-AR712.cn

Chrom Perfect Chromatogram Report

950 CH4

Impurities in Argon
H2 O2 N2 CH4 CO RT 0.98 1.34 1.75 2.52 2.91 Area 205288 465894 104985 1128221 101133 ppm 1.86 2.33 2.18 2.00 1.93
2.52 H2 0.98 N2

900

850 Response - MilliVolts

800

700

650

600 0.0 0.5 1.0 1.5 2.0 2.5 Time - Minutes 3.0 3.5 4.0 4.5 5.0

Printed on 6/25/09 4:29:58 PM

1.75

750

1.34 O2

2.91 CO

Page 1 of 1

Specications
Detector Type Sensitivity Temperature Range Linearity Carrier Gas

Ordering Information
Part No. AR712 Gas Chromatograph w/ High Frequency Argon Discharge Detector (HFADD) for the determination of impurities in argon. Single valve/single column instrument for H2, O2, N2, CH4, & CO (automated 6-port GSV with appropriate column), 220 V Gas Chromatograph w/ High Frequency Argon Discharge determination of impurities in argon. Dual valve/dual column instrument for H2, O2, N2, CH4, CO, & CO2 (automated 10 & 4-port GSVs with appropriate columns), 220 V Complete Accessory Package for Series AR712/AR722 GC (REQUIRED to install & operate a Series AR712/ AR722 GC System), 220 V

discharge luminosity 30 ppb CH4 ambient to 400 C > 103 UHP argon with UHP 2-stage argon regulator*
*note: if the carrier gas is not as pure as the sample gas, reverse peaks can occur for gases which are in lower concentration in the sample gas.

AR722

Column Oven Temp. Range Temp. Readout Temp. Control Accuracy Stability

ambient +4 C digital, LCD 1% of rates, 1% of setting < 0.05 C/hr, 30 min warm up pressure regulator for ow control through columns Inlets: 1/8 VCR Swagelok Outlets: 1/8 Swagelok Output continuous adjustment by means of external potentiometer 0 - 100 mV 50 F to 104 F (10 C to 40 C) 19 W x 18 H x 18 D (48.26 x 45.72 x 45.72 cm) Net: 150 lbs. (68 kg)

59-575-230

Gas Flow Connections High Voltage Power Supply Output Signal Operating Temp Overall Dimensions Weight

A05-0003-002-VCR High Purity, Two Cylinder, Carrier Gas Changeover Manifold System with 580 CGA ttings, purge/vent valves, wall mounted. (HIGHLY recommended) 21-072 180-567 Mini Gas Leak Detector, 220 V Hand-held Digital Flowmeter (for non-corrosive gases)

Global Headquarters GOW-MAC Instrument Co. 277 Brodhead Road, Bethlehem, PA 18017 U.S.A. Tel: (610) 954-9000 Fax: (610) 954-0599 E-mail: sales@gow-mac.com www.gow-mac.com
Analytical instruments since 1935

Beijing Office GOW-MAC Instrument Co. - Beijing 6A1502 (100053) +86-10-83813136 : +86-10-83813136 : sales@gow-mac.com.cn www.gow-mac.com.cn

SB-AR712.cn 1009 2009 GOW-MAC Instrument Co. All rights reserved. The GOW-MAC logo and design are registered trademarks of GOW-MAC Instrument Co. in the United States and other countries. Information, descriptions, photographs and specifications in this publication are subject to change without notice. GOW-MAC Instrument Co. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material.