Application
Mixing shunt FHM-C7 (Alpha2 pump) The Danfoss compact mixing shunts are used for regulation of ow and supply temperature in hydronic oor heating systems. The compact, exible design allows mounting the mixing shunt directly to the manifold on both left and right side, with the primary pipe connection from the side or below. A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature to the underoor heating system always remains constant. A safety thermostat (standard in models FHM-C1, FHM-C5 and FHM-C7) protects the oor against too high temperatures. A built-in check valve ensures correct ow direction and the mixing shunts are prepared for inserting temperature sensors.
Danfoss HES
Mixing shunt FHM-C8/C9 (Alpha2 pump) An air-vent on top and a thermometer completes the mixing shunt. FHM-C1, -C2 and -C3 incorporates an electronic variable speed pump (Alpha+). FHM-C5 and -C6 have a standard 3-speed pump (UPS). FHM-C7, -C8 and -C9 are equipped with lowenergy, variable speed pumps (Grundfos Alpha2), including a selectable night set-back function. The FHM-Cx compact mixing shunts can be mounted directly to the Danfoss manifold system without the use of special equipment. By using Danfoss oor heating controls all expectations of a professional oor heating system are fulllled.
VD.UL.F3.02
Danfoss 03/2009
Product
MeasureElectric ment safety set for thermo stat needles2) FH-ST553) FHM-MS Standard Accessory Accessory Accessory Accessory Standard Accessory Accessory Standard Accessory Accessory Standard Accessory Standard Accessory Accessory
Code no.
13 kW 13 kW 9 kW 9 kW 13 kW 13 kW 13 kW 9 kW
Alpha+ 15-60
Alpha+ 15-60 Accessory Alpha+ 15-40 Accessory UPS 15-40 UPS 15-60 Alpha2 15-60 Accessory Accessory Standard
Max eect at t = 30K in primary (70/40) and t = 5K (10K) in secondary line with heatloss 50 W/m. Can only be used by new installation of shunt and manifold. 3) Safety thermostat with prewired plug 230V (length 1m) and wire for i.e. pump connection or together with CF2, switch o temp. 55 C, 4K.
Body, unions and other metal parts O-rings and seals Check valve Weight (depending on model) Max. dierential pressure Max. working pressure Max. ow temperature
Brass / stainless steel EPDM POM / stainless steel approx. 3.5 - 4 kg 0.6 bar PN10 90 C
Accessories
Product Thermometer 0-60C, 35 mm Temperature controller, 15-50 C Electric safety thermostat Flow limiter Measuring set for needles Angle ttings, set 2 stk.
VD.UL.F3.02
Danfoss 03/2009
Danfoss HES
Electrical connection
The FH-ST safety thermostat is xed on the tube and protects oor and system against too high temperatures, especially important for wooden oors. The FH-ST thermostat switches o the power supply of the oor heating base unit, when the temperature reaches 55 C. By switching o the Technical data, FH-ST55 Code number Shut o temperature Switch dierence Classication
power supply of the oor heating base unit, the actuators (NC) will close automatically and the oor heating system is protected. The FH-TC can also be connected to a pump or a zone valve. Note! The electrical installation must be carried out by an authorized installer only (230V DC).
088U0301 55 C 4K IP 40 (mounted)
FH-TC is a self-acting thermostatic sensor, used for ow temperature control of oor heating and radiator heating systems. The water temperature is directly measured by a stainless steel immersion sensor. Features: Closes on rising sensor temperature. Closes against differential pressure of up to 6 bar. Temperature range: 18 - 52 C. Designed for pressure PN 10.
1 20 C
2 25 C
3 30 C
4 35 C
5 40 C
6 45 C
(max) 52 C
Danfoss HES
VD.UL.F3.02
Danfoss 03/2009
Danfoss
IN
PFM 3000/4000
2
3 1
The ow running through the FHM-MS (xed orice) can be measured by using the Danfoss measuring instruments PFM 3000 / 4000 or other brands of measuring equipment. The FHM-MS valve is supplied with two measuring nipples for 3 mm needles. The measuring nipples are placed across a xed orice and the dierential
L/h
17
VD.UL.F3.02
Danfoss 03/2009
OUT
kvs 7,4
pressure can be measured across this orice. The value of the xed orice (kVS 7,4) and the differential pressure will be used in the measuring equipment to dene the ow. Measuring on a xed orice valve is very fast and easy.
2
3 4
Danfoss HES
FHM-C
FHM-C
Danfoss HES
VD.UL.F3.02
Danfoss 03/2009
93
120
Danfoss
25
41
34
OUT
118
20 25
40
95
FHM-C1
93
74
Danfoss
25
41
34
OUT
4 6
5
118
20 25
40
49
FHM-C2, FHM-C3
VD.UL.F3.02
Danfoss 03/2009
Danfoss HES
213
3
213
3 4
5
75
74
Danfoss
25
41
34
OUT
4 6
5
20 25 118
40
49
FHM-C5, FHM-C6
60
120
Danfoss
213
25 41 34
2
3 1
OUT
128
20 25
40
95
FHM-C7
Danfoss HES
VD.UL.F3.02
Danfoss 03/2009
213
4
60
74
Danfoss
25
41
34
2
3 1
OUT
4 6
128
20 25
40
49
FHM-C8, FHM-C9
VD.UL.F3.02
Danfoss 03/2009
Danfoss HES
213
5