Data sheet

Compact Mixing Shunts for Floor Heating FHM-Cx

Application

Mixing shunt FHM-C1 ( Alpha+ pump)

Mixing shunt FHM-C2/ FHM-C3 (Alpha+ pump)

Mixing shunt FHM-C5 (UPS pump)

Mixing shunt FHM-C6 (UPS pump)

Mixing shunt FHM-C7 (Alpha2 pump) The Danfoss compact mixing shunts are used for regulation of ow and supply temperature in hydronic oor heating systems. The compact, exible design allows mounting the mixing shunt directly to the manifold on both left and right side, with the primary pipe connection from the side or below. A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature to the underoor heating system always remains constant. A safety thermostat (standard in models FHM-C1, FHM-C5 and FHM-C7) protects the oor against too high temperatures. A built-in check valve ensures correct ow direction and the mixing shunts are prepared for inserting temperature sensors.
Danfoss HES

Mixing shunt FHM-C8/C9 (Alpha2 pump) An air-vent on top and a thermometer completes the mixing shunt. FHM-C1, -C2 and -C3 incorporates an electronic variable speed pump (Alpha+). FHM-C5 and -C6 have a standard 3-speed pump (UPS). FHM-C7, -C8 and -C9 are equipped with lowenergy, variable speed pumps (Grundfos Alpha2), including a selectable night set-back function. The FHM-Cx compact mixing shunts can be mounted directly to the Danfoss manifold system without the use of special equipment. By using Danfoss oor heating controls all expectations of a professional oor heating system are fulllled.

VD.UL.F3.02

Danfoss 03/2009

Data Sheet Technical data

Compact Mixing Shunt: FHM-Cx


Supply voltage . . . . . . . . . . . . . . 230 V AC Primary connection . . . . . . . . . . . . . . . Flow temperature control FH-TC . . . 18-52 C Supply ow thermometer FH-DT . . . 0-60 C Integrated check valve . . . . . . . . . . . . . Yes
1) 1) Max. Max. eect at eect at Pump type, secondary secondary Grundfos t = 5K t = 10K

Product

Flow limiter FHM-FL Standard

MeasureElectric ment safety set for thermo stat needles2) FH-ST553) FHM-MS Standard Accessory Accessory Accessory Accessory Standard Accessory Accessory Standard Accessory Accessory Standard Accessory Standard Accessory Accessory

Code no.

FHM-C1 FHM-C2 FHM-C3 FHM-C5 FHM-C6 FHM-C7 FHM-C8 FHM-C9


1) 2)

7 kW 7 kW 4.5 kW 4.5 kW 7 kW 7 kW 7 kW 4.5 kW

13 kW 13 kW 9 kW 9 kW 13 kW 13 kW 13 kW 9 kW

Alpha+ 15-60

088U0080 088U0081 088U0082 088U0084 088U0085 088U0086 088U0087 088U0088

Alpha+ 15-60 Accessory Alpha+ 15-40 Accessory UPS 15-40 UPS 15-60 Alpha2 15-60 Accessory Accessory Standard

Alpha2 15-60 Accessory Alpha2 15-40 Accessory

Max eect at t = 30K in primary (70/40) and t = 5K (10K) in secondary line with heatloss 50 W/m. Can only be used by new installation of shunt and manifold. 3) Safety thermostat with prewired plug 230V (length 1m) and wire for i.e. pump connection or together with CF2, switch o temp. 55 C, 4K.

Body, unions and other metal parts O-rings and seals Check valve Weight (depending on model) Max. dierential pressure Max. working pressure Max. ow temperature

Brass / stainless steel EPDM POM / stainless steel approx. 3.5 - 4 kg 0.6 bar PN10 90 C

Accessories

Product Thermometer 0-60C, 35 mm Temperature controller, 15-50 C Electric safety thermostat Flow limiter Measuring set for needles Angle ttings, set 2 stk.

Type FHD-T FH-TC FH-ST55 FHM-FL FHM-MS FHM-AF

Code no. 088U0029 088U0302 088U0301 088U0303 088U0304 088U0305

VD.UL.F3.02

Danfoss 03/2009

Danfoss HES

Data Sheet Safety thermostat, FH-ST55

Compact Mixing Shunt: FHM-Cx

Electrical connection

230V / 16A TS 55C

The FH-ST safety thermostat is xed on the tube and protects oor and system against too high temperatures, especially important for wooden oors. The FH-ST thermostat switches o the power supply of the oor heating base unit, when the temperature reaches 55 C. By switching o the Technical data, FH-ST55 Code number Shut o temperature Switch dierence Classication

power supply of the oor heating base unit, the actuators (NC) will close automatically and the oor heating system is protected. The FH-TC can also be connected to a pump or a zone valve. Note! The electrical installation must be carried out by an authorized installer only (230V DC).

088U0301 55 C 4K IP 40 (mounted)

Temperature controller, FH-TC

FH-TC is a self-acting thermostatic sensor, used for ow temperature control of oor heating and radiator heating systems. The water temperature is directly measured by a stainless steel immersion sensor. Features: Closes on rising sensor temperature. Closes against differential pressure of up to 6 bar. Temperature range: 18 - 52 C. Designed for pressure PN 10.

1 20 C

2 25 C

3 30 C

4 35 C

5 40 C

6 45 C

(max) 52 C

Danfoss HES

VD.UL.F3.02

Danfoss 03/2009

Data Sheet Measuring set, FHM-MS

Compact Mixing Shunt: FHM-Cx

Danfoss

IN

PFM 3000/4000

2
3 1

The ow running through the FHM-MS (xed orice) can be measured by using the Danfoss measuring instruments PFM 3000 / 4000 or other brands of measuring equipment. The FHM-MS valve is supplied with two measuring nipples for 3 mm needles. The measuring nipples are placed across a xed orice and the dierential

Flow limiter, FHM-FL

L/h

17

VD.UL.F3.02

Danfoss 03/2009

OUT

kvs 7,4

pressure can be measured across this orice. The value of the xed orice (kVS 7,4) and the differential pressure will be used in the measuring equipment to dene the ow. Measuring on a xed orice valve is very fast and easy.

2
3 4

Danfoss HES

Data Sheet System

Compact Mixing Shunt: FHM-Cx

FHM-C

Combined oor heating system with boiler

FHM-C

Combined oor heating system with heat pump

Danfoss HES

VD.UL.F3.02

Danfoss 03/2009

Data Sheet Dimensions

Compact Mixing Shunt: FHM-Cx

93

120

Danfoss

25

41

34

OUT

118

20 25

40

95

FHM-C1

93

74

Danfoss

25

41

34

OUT
4 6
5

118

20 25

40

49

FHM-C2, FHM-C3

VD.UL.F3.02

Danfoss 03/2009

Danfoss HES

213
3

213
3 4
5

Data Sheet Dimensions

Compact Mixing Shunt: FHM-Cx

75

74

Danfoss

25

41

34

OUT
4 6
5

20 25 118

40

49

FHM-C5, FHM-C6

60

120

Danfoss

213
25 41 34
2
3 1
OUT

128

20 25

40

95

FHM-C7

Danfoss HES

VD.UL.F3.02

Danfoss 03/2009

213
4

Data Sheet Dimensions

Compact Mixing Shunt: FHM-Cx

60

74

Danfoss

25

41

34

2
3 1

OUT
4 6

128

20 25

40

49

FHM-C8, FHM-C9

VD.UL.F3.02

Danfoss 03/2009

Danfoss HES

213
5