The six interdependent disciplines that form the protection plan are:
1. Capture the lightning strike 2. Convey this energy to ground 3. Dissipate energy into the grounding system 4. Bond all ground points together 5. Protect incoming AC power feeders 6. Protect low voltage data/telecommunications circuits At ERICO, we offer innovative, efcient grounding and bonding products as well as engineering experience and technical support. With this experience, ERICO is a world-leading authority in the design and construction of permanent, low-impedance grounding systems. ERICO employs a quality-assurance program to help ensure that detailed procedures required for every step of the operation produce the best possible system for our clients. This attention to detail includes design, materials procurement, manufacturing, installation and testing. Our research and development capabilities provide continuous design improvement with new and improved products that preempt the challenging requirements of ever-evolving industry applications. Engineering expertise is shared among the other ERICO operations worldwide, to provide a comprehensive global knowledge pool.
www.erico.com
RAILWAY
UTILITY
Founded in 1903 as the Electric Railway Improvement Company, ERICO developed the CADWELD exothermic welding process in 1938. CADWELD connections have found industry-wide acceptance as the ultimate grounding and bonding connection. During the 1970s, ERICO pioneered the copperbonded steel ground rod electrode. Today, ERICOs range of facility electrical protection products includes ERITECH ground rods, grounding clamps and accessories, electrical bonding products, ground enhancement material, ground testers, lightning protection components, equipotential mesh and mats, and signal reference grids; low-voltage surge protection devices; and CADWELD exothermic connections.
Table of Contents
Grounding Principles........................................ 2 10 Grounding System Components.................... 11 28 Ground Conductors................................................. 12 13
Ground Rods and Couplers...................................... 14 17 Ground Clamps and Connectors.............................. 18 23 Chemical Ground Electodes...................................... 24 25 Ground Enhancement Material................................. 26 29 Grounding Accessories..................................................... 30 Ground Plates.......................................................... 31 32
Equipotential Bonding.................................... 33 62
Grounding Bus Bars.................................................. 34 37 Telecom Ground Bars............................................... 38 39 Perimeter Grounding Bus Bars.................................. 40 41 Equipment Ground Plates................................................. 42 Equipment Ground Plate Assemblies................................ 43 Aircraft Grounding Receptacles........................................ 44 Signal Reference Grids.............................................. 45 49 Equipotential Mesh and Mats................................... 50 53 Bonding Devices....................................................... 54 55 Copper Bonding Straps............................................ 56 57 Fence Clamp Assemblies.......................................... 58 60 Static Grounding and Bonding................................. 61 62
Technical Information..................................... 66 68
CADWELD is an exothermic welding system for developing permanent welded electrical connections that will never loosen, corrode or increase in resistance. High-quality CADWELD connections are an integral part of the grounding and bonding process. Contact an ERICO representative today to request additional information on CADWELD.
www.erico.com
Grounding Principles
Introduction
Grounding and bonding are an integral part of any modern electrical protection system design. An effective, low-impedance ground system is a key element of this system. It is crucial to help provide personnel safety, as well as reliable protection for vital equipment and to minimize interruptions of service and costly downtime. With over a century of experience in the design and manufacture of bonding and grounding products, ERICO, a single source provider, offers what we believe is the best range of long lasting and cost-effective grounding products available. Soil conditions and seasonal patterns vary from site to site, the methods of grounding need to be considered on an individual basis.
It is a fundamental fact that electricity ALWAYS flows to the point of lowest potential. The task is to help ensure that electricity, including faults, lightning and electronic noise, flows to this point with maximum safety to people, while maintaining the reliability of equipment. Therefore we must help ensure the safe, controlled flow of electricity with minimum voltage drop to earth in all cases.
TECHNICAL INFORMATION
There are important reasons why a grounding system should be installed. 1 The most important reason is to help protect people! 2 To help provide protection of structures and equipment from unintentional contact with live conductors. 3 To help support maximum safety from electrical system faults and lightning.
www.erico.com
Grounding Principles
Why is Good Grounding Important?
The transient nature of lightning with its associated fast rise times and large magnitude currents mean that special consideration needs to be given to grounding, for lightning protection to be effective. Many factors such as soil resistivity variations, installation accessibility, layout and existing physical features are all site specic and tend to affect decisions on grounding methods employed. The primary aim of a direct strike grounding system is to: Efficiently dissipate lightning energy into the ground Help protect equipment and personnel
Ground Impedance
Soil resistivity is an important design consideration. It varies markedly for different soil types, moisture content and temperatures and gives rise to variations in ground impedances.
Grounding Principles
Low impedance is the key to lightning protection. All grounding connections should be as short and direct as possible to minimize inductance and reduce peak voltages induced in the connections. The ground electrode system must efciently couple lightning surges into the ground by maximizing capacitive coupling to the soil. The resistance of the ground itself to lightning currents must also be minimized. Only when all these factors are taken into account will maximum lightning protection be achieved.
Downconductor
www.erico.com
TECHNICAL INFORMATION
GroUNdiNg PriNciPles
Grounding Principles
Good corrosion resistance
Figure 1-A Distance from the electrode
The ground electrode system should be corrosion resistant, and compatible with other conductors that are buried and bonded to the ground system. Copper is by far the most common material used for grounding conductors. In general, some form of maintenance or inspection procedure should be adopted to ensure the long-term effectiveness of a grounding system.
Ground Rod
Ground Resistance
Figure 1-B
When current flows from a ground electrode into the surrounding soil, it is often described as flowing through a series of concentric shells of increasing diameter. Each successive shell has a greater area for current flow and consequently, lower resistance. At some point distant from the earth conductor the current dissipation becomes so large and current density so small, that the resistance is negligible. In theory, the ground resistance may be derived from the general formula:
GroUNdiNg PriNciPles
Figure 1-B illustrates current ow from the injection point of a single ground electrode. As current ows out from the central injection point, a voltage gradient on the ground surface around the electrode is produced. This gradient levels off to a plateau at some distance from the electrode, as seen in Figure 1-A. The impedance seen by the current is determined by the soil particles in direct contact with the surface of the rod, and by the general impedance of the soil.
TECHNICAL INFORMATION
R = __ 2L
{(ln 4L) - 1} r
R = resistance in ohms of the ground rod to the earth (or soil) L = grounding electrode length r = grounding electrode radius = average resistivity in ohms-cm. 4 www.erico.com
Grounding Principles
Conditions Influencing Soil Resistivity
The resistance of the earth itself (soil resistivity) can significantly impact the overall impedance of the grounding system. Several factors, such as soil composition, moisture content, mineral content, contaminants, etc., determine the overall resistivity of the earth.
Resistivity ohm-cm SOIL TYPE
Fills ashes, cinders, brine wastes Clay, shale, gumbo, loam Clay, shale, gumbo, loam with varying proportions of sand and gravel Gravel, sand, stones, with little clay or loam
U.S. Bureau of Standards Technical Report 108
Average
2,370 4,060 15,800 94,000
Min.
590 340 1,020 59,000
Max.
7,000 16,300 135,000 458,000
Figure 2
4. The soil resistivity level r (in ohms/cm) is then calculated using the formula: r=2paR where: R = the resistance figure, in ohms a = the separation of the test stakes, in meters.
p = 4AR 1 + 2A 2A 2 2 (A2 + 4B2) (A + 4B ) Where: A = distance between the electrodes in centimeters B = electrode depth in centimeters If A > 20 B, the formula becomes: p = 2 AR (with A in cm) p = 191.5 AR (with A in feet) p = Soil resistivity (ohm-cm) This value is average resistivity of the ground at a depth equivalent to the distance A between two electrodes.
Sphere of Influence - electrical current flows from the ground rod into surrounding soil and progressively dissipates in waves of increasing diameter.
www.erico.com
TECHNICAL INFORMATION
GroUNdiNg PriNciPles
3. The DC test option on the tester is then selected and performed, and the resistance figure R recorded.
Grounding Principles
GROUNDING PRINCIPLES
Avoid hazardous Step and Touch Potentials (shock) or even death by low impedance grounding and bonding between metallic equipment, chassis, piping, and other conductive objects so that currents, due to faults or lightning, do not result in hazardous voltage rise.
Without Protection
Touch Potential
Touch Potential is similar to Step Potential except that the fault current passes through the persons arm and torso on the way to the ground. Another function of the grounding system is to provide a reference for circuit conductors to stabilize their voltage to ground during normal operation. The earth itself is not essential to provide a reference function; another suitable inductive body may be used instead. The function of a grounding electrode system and a ground terminal is to provide a system of conductors, which ensures electrical contact with the earth.
Difference of Potential 50% Drop
TECHNICAL INFORMATION
www.erico.com
Grounding Principles
Grounding / Earthing System Design
Grounding systems are important. It is not expensive to build an appropriate ground system during initial construction of a facility, but it can be very expensive to add to it, enhance it, or replace it after the facility is complete. Care should be taken to design a system that is appropriate both for clearing ground faults and dissipating lightning energy. The system must have a long performance life, meet applicable codes / standards for safety, and have sufficient bonding points to make it easy to add new equipment / facility grounding to it easily. A proper facility grounding system incorporates these necessities in the most cost-effective manner that will last for the design life of the facility. ERICO is a manufacturer and marketer of grounding, bonding, lightning protection and surge protection products and systems. ERICO has many knowledgeable and experienced engineers on staff with the training and the tools (including some of the latest design software) to design appropriate grounding systems. These engineers can assist facility owners, engineers and contractors in designing the most appropriate system for the facility in question. Grounding Chain 1. Grounding Electrode Conductor 2. Grounding Connections 3. Grounding Electrode 4. Electrode to Soil Resistance 5. Soil
www.erico.com
TECHNICAL INFORMATION
GroUNdiNg PriNciPles
Grounding Principles
The Grounding Chain
The performance of the grounding system is determined by the quality of the following five components all of which are of equal importance. 1. The Grounding Electrode Conductor. Typically made from copper or copper-bonded steel, the grounding electrode conductor must be large enough to withstand the maximum available fault current over the maximum clearing time. 2. The Grounding Connections. Often overlooked, the grounding connections are used to tie the elements of the electrode system together. Exothermically welded connections provide a molecular bond that will never loosen or corrode. Mechanical connectors, such as crimp, bolted, and wedge type, rely on physical pointto-point surface contact to maintain the integrity of the electrical connection. IEEE Standard 837 provides detailed information on the application and testing of permanent grounding connections. ERICO can provide an independent, third-party test report evaluating the performance of these connectors in accordance with the testing procedures set forth in IEEE 837 Standard for Qualifying Permanent Substation Grounding Connections. 3. The Grounding Electrode. The grounding electrode provides the physical connection to the earth and is the instrument used to dissipate current into it. There are two main types of electrodes. Natural electrodes are intrinsic to the facility and include metal underground water pipe, the metal frame of the building (if effectively grounded), and reinforcing bar in concrete foundations. Made electrodes are installed specifically to improve the performance of the ground system and include wire meshes, metallic plates, buried copper conductor and rods or pipes driven into the ground. The ground rod is the most widely used electrode. 4. Electrode to Soil Resistance. Amount of rod surface and rod replacement are the controlling factors. Doubling diameter reduces resistance by only 10% and is not cost effective. Doubling rod length, however, theoretically reduces resistance by 40%. The most common solution is proper placement of multiple rods that are driven to the required depths. 5. The Soil. The soil resistivity, measured in ohm-centimeters or ohm-meters, plays a significant role in determining the overall performance of the grounding system and must be known before a proper grounding system can be engineered. Measuring soil resistivity allows the design engineer to locate an area with the most conductive soil
and to determine the depth of the conductive soil so that electrodes can be placed accordingly. T he grounding system will carry little or no current for long periods of time until a fault occurs or a lightning strike or other transient requires dissipation. At that point, the grounding system components will be expected to perform like new while conducting large amounts of current. Most of the grounding system is concealed below grade, making inspection of the grounding components difficult or impossible. The underground environment is a harsh one. The initial selection of the components used in the grounding system is of critical importance to its long-term effectiveness.
GroUNdiNg PriNciPles
TECHNICAL INFORMATION
www.erico.com
Galvanized coating: Relatively short service life May crack if rod is bent
The photo shows two ground rods subjected to the same pressure load test. The ERITECH copper-bonded ground rod, shown on the left, will bend without tears, cracks or folds, to the outer sheath. The inferior copperclad rod shown on the right, has developed cracks and creases to the outer sheath, which will significantly reduce its serviceable life and put the integrity of the entire electrode at risk.
Carbon Steel core and tip*: Greater tensile strength Deep driving capability
* ERICO copper-bonded and galvanized rods
www.erico.com
TECHNICAL INFORMATION
The photo on the right shows a galvanized steel ground rod driven vertically into the ground at the Pawnee testing site in Las Vegas, NV. One area is reduced from a 3/4 diameter to approximately a 1/4 diameter due to extensive corrosion. The eventual failure would result in a potentially catastrophic loss of ground.
Comparative Cost
35
300%
Years
30 25 20
200%
TECHNICAL INFORMATION
15 10 5 0
100%
Zinc Galvanized
Zinc Galvanized
Stainless Steel
10
www.erico.com
Stainless Steel
0%
PGS 14-17
GROUND RODS
PG 21
PG 17
COMPRESSION cOUPLER
PG 18
FENCE CLAMP
PG 28
GROUND PLATE
www.erico.com
11
Ground Conductors
Conductors
There are two basic criteria for grounding conductor selection: 1. The physical characteristics of the conductor must be of a robust nature, sufficient for the environment. 2. The cross sectional area of the conductor must be of sufficient size, so that it shall successfully conduct the maximum fault current for a period, which allows the operation of protection equipment (or the dissipation of this energy).
GROUND CONDUCTORS
Physical Characteristics
The most common ground conductor is a soft drawn, stranded copper conductor. Flat copper strip / tape is also popular because it offers a large surface area, resulting in lower impedance. In some circumstances, the maximum fault current for the installation is small. While a conductor of correspondingly small size could be used, a minimum cross section, often set by the governing authority or applicable standards body (to minimize potential damage likely to occur from any future excavation on the site), is applied.
Insulated Cables
Contact ERICO for available sizes #8 AWG and up.
Cross section
12
www.erico.com
Ground Conductors
Theft Deterrent Composite Cable
Theft deterrent composite cables are bare or insulated concentric stranded conductors that consist of peripheral galvanized steel stranding, which protects and conceals the internal tinned copper strands. These conductors are ideal for exposed elecrical distribution grounding leads where copper theft may occur. These conductors are difficult to cut with hand tools and the outter steel stranding is magnetic, which further deters thieves looking for copper.
CC5A04
CC5A05
Resistance
Fusing Standard Outside Capacity Weight Packaging Diameter EquivaQuantity lency 57 lbs (25.85 kg)* 58 lbs (26.31 kg)* 109 lbs (49.44 kg)*
(1) Tinned 112% of 0.330 in Copper, (6) 0.485 /1,000 4 AWG 250 ft (0.838 Galvanized ft; 1.499 /km (100% of (76.2 m) cm) Steel 16 mm) (3) Tinned 113% of 0.334 in Copper, (16) 0.457 /1,000 4 AWG 250 ft (0.848 Galvanized ft; 1.591 /km (100% of (76.2 m) cm) Steel 16 mm) (133) Tinned Copper, (21) Galvanized Steel (133) Tinned Copper, (21) Galvanized Steel (133) Tinned Copper, (24) Galvanized Steel (133) Tinned Copper, (24) Galvanized Steel (133) Tinned Copper, (24) Galvanized Steel (133) Tinned Copper, (28) Galvanized Steel (133) Tinned Copper, (28) Galvanized Steel 0.098 /1,000 ft; 0.320 /km 100% of 0.526 in 2/0 AWG (1.336 (> 50 cm) mm) 100% of 0.526 in 2/0 AWG (1.336 (> 50 cm) mm) 100% of 0.572 in 3/0 AWG (1.453 (> 70 cm) mm) 100% of 0.572 in 3/0 AWG (1.453 (> 70 cm) mm) 200 ft (61.0 m)
CC5A05
CC5A20 CC5A20INS
CC5A20
CC5A20INS
CC5A30 CC5A30INS
200 ft (61.0 m)
135 lbs (61.24 kg)* 135 lbs (61.23 kg)* 135 lbs (61.23 kg)*
CC5A30
200 ft (61.0 m)
CC5A30INS
200 ft (61.0 m)
CC5A40
CC5A40INS
CC5A30INSK
100% of 0.572 in 677.2 lbs 3/0 AWG 1000 ft (1.453 (367.2 (> 70 (304.8 m) cm) kg)* mm) 100% of 0.656 in 4/0 AWG (1.666 (> 95 cm) mm) 100% of 0.656 in 4/0 AWG (1.666 (> 95 cm) mm) 200 ft (61.0 m) 172 lbs (78.02 kg)* 199 lbs (90.27 kg)*
CC5A40INS
200 ft (61.0 m)
www.erico.com
13
GROUND CONDUCTORS
Driving Sleeves
The driving sleeve fits over the pointed ground rod to protect the rod end from mushrooming as the ground rod is driven into earth.
Ground Rods
GROUND RODS AND COUPLERS Ground Rod Diameter and Length
Ground rod diameter must also be considered. Although larger diameter rods are more rigid and less prone to whip or bending, they may have a greater drag than smaller diameter rods when being driven. It must also be noted that increasing the ground rod diameter has relatively small impact on grounding system resistance when compared to length. Standards nominate a minimum diameter or periphery and thickness if not cylindrical, mainly based on mechanical strength. In general, lightning protection standards recommend copper-bonded electrodes of specified diameter. Standard UL 467 requires a minimum rod length of 8 with a minimum diameter of 0.50 and 10 mils of copper. Other standards may nominate a specific resistance for the installation. If space is limited, the contractor may be required to install electrodes to a depth that achieves the required value.
Compression Coupling
Couplings enable ground rods to be driven quickly and easily without the risk of rod separation. They are generally tapered so when the rod is driven into the coupling, the two parts compress to form a conductive connection.
Threaded Coupling
Threaded couplings allow for full contact of the rod point with the butt end of the preceding rod.
14
www.erico.com
99.9% pure electrolytic copper coating Molecular bond to nickel-sealed high strength steel core Tensile strength greater than 80,000 PSI on 1/2 & 90,000 PSI on 5/8 and 3/4 Minimum copper coating of 10 mils on rods listed to UL 467 Legibly marked with manufacturers ID and catalog designation Manufactured to exceed the requirements of ANSI /NEMA GR1
Part No. 613840** 613880** 611380 615880 615883 613480 613483 611300 615800 615803 613400 614400 615812 613412 615815 613415 Nominal Diameter (in) 3/8 3/8 1/2 5/8 5/8 3/4 3/4 1/2 5/8 5/8 3/4 1 5/8 3/4 5/8 3/4 Length (ft) 4 8 8 8 8 8 8 10 10 10 10 10 12 12 15 15 Plating Weight per Standard Thickness (mils) 100 rods (lbs) Bundle 10 135 5 10 10 10 13* 10 13* 10 10 13* 10 10 10 10 10 10 270 553 680 680 1,000 1,000 738 844 844 1,240 2,204 1,000 1,480 1,275 1,850 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Part No. B13714 B13716 B13731 B13718 B13733 B13722 B13737
Ground Rod Size (Unthreaded) 1/2 Copper-Bonded or Steel rod 5/8 Copper-Bonded rod (.563 diameter) 5/8 Steel rod (.625 diameter) 3/4 Copper-Bonded rod (.682 diameter) 3/4 Steel rod (.750 diameter) 1 Copper-Bonded rod (.914 diameter) 1 Steel rod (1.00 diameter)
Standard Package 1 1 1 1 1 1 1
Standard Package 1
* 13 mils of copper meet specifications of RUS. ** Non-UL listed rods. Additional lengths available.
Ground Rod Size 5/8 Copper-Bonded Rods (.563 diameter) 3/4 Copper-Bonded Rods (.682 diameter)
Standard Package 1 1
Standard Package 25 25 25
www.erico.com
15
Tapered so when rod is driven into coupling, parts compress to form a conductive connection
Cold-rolled threads with continuous, unbroken grain flows preserve copper coating and are stronger than cut threads Electrolytically copper-bonded steel: copper is molecularly bonded to nickel-sealed, high-strength steel cores Minimum copper coating of 10 mils on rods listed to UL 467 ERITECH name, length, diameter and part number is roll-stamped within 12 of chamfered end UL logo and control number where applicable stamped on each rod for easy inspection after installation Manufactured to exceed the requirements of ANSI/NEMA GR1
Part No. Nominal Diameter (in) 1/2 1/2 3/4 3/4 1 5/8 5/8 5/8 5/8 5/8 5/8 5/8 Length (ft) 10 8 10 8 10 10 3 4 5 6 8 8 Plating Thickness (mils) 10 10 10 10 10 10 10 10 10 10 10 13* Weight per 100 rods (lbs) 688 540 1,240 1,000 2,204 844 262 344 420 504 680 680 Standard Bundle 5 5 5 5 5 5 5 5 5 5 5 5
631300 631380 633400 633480 634400 635800 635830 635840 635850 635860 635880 635883
Standard Package 25 25 25 1
16
www.erico.com
* For rods with a UPC label, add UPC to end of part number (example: 813400UPC). Meets specifications of RUS.
Standard Package 1 1
The UL-Listed, NECCompliant ERITECH CGE kit allows for installation from ground level and is much easier to transport than eight-foot ground rods. The ERITECH CGE kits are designed for #6 and #4 solid copper conductor applications.
KIT INCLUDES 2ERITECH ERITECH Article Part ERITECH HAMMERLOCK Drive Wire Sizes Metric Wire Sizes No. No. Ground or Clamp Sleeve Rods 155991 CGE51K 615840 EHL58C1K EDS58 #4 Sol - #6 Sol 10mm2 Str - 16mm2 Str 155993 CGE5CP 615840 CP58 EDS58 #8 Sol - #2 Str 10mm2 Sol - 35mm2 Str
Standard Package 25 25
www.erico.com
17
Part No.
Conductor Range (AWG) 1/0 stranded 2/0 stranded 4 stranded 2 stranded 6 solid 4 solid 1/0 stranded 2/0 stranded 4 stranded 2 stranded 6 solid 4 solid 1/0 stranded 2/0 stranded 4 stranded 2 stranded 6 solid 4 solid
For Copper-bonded Ground Rods 1/2 (full) EHL12FC2G EHL12FC1V EHL12FC1K EHL58C2G EHL58C1V EHL58C1K EHL34C2G EHL34C1V EHL34C1K Standard Package: 25 Part No. EHL58G2G EHL58G1V EHL58G1K EHL34G1V EHL34SG1V* EHL34G1K EHL34SG1K* Standard Package: 25 Ground Rod Size (in) 5/8 (full) 5/8 (full) 5/8 (full) 3/4 3/4 3/4 3/4 1/2 (full) 1/2 (full) 5/8 5/8 5/8 3/4 3/4 3/4
Conductor Range (AWG) 1/0 stranded 2/0 stranded 4 stranded 2 stranded 6 solid 4 solid 4 stranded 2 stranded 4 stranded 2 stranded 6 solid 4 solid 6 solid 4 solid
For Galvalnized Ground Rods Part No. Ground Rod Size (in) Conductor Range (AWG) 6 solid 4 solid 6 solid 4 solid 6 solid 4 solid
For Copper-bonded Ground Rods 1/2 in EHL12FC1K1K* EHL58C1K1K* For Galvalnized Ground Rods EHL58G1K1K* *Not UL Listed
5/8 in 5/8 in
Part No. Standard Duty CP38 CP58 CP34 Heavy Duty HDC12 HDC58 HDC58R HDC34 HDC34SP* HDC1
Rod Diameter (in) 3/8 1/2 - 5/8 1/2 - 3/4 1/2 5/8 5/8 3/4 3/4 1
Conductor Range (AWG) 10 solid 2 stranded 10 solid 2 stranded 10 solid 1/0 stranded 10 solid 2 stranded 8 solid 1/0 stranded 8 solid 1/0 stranded 8 solid 1/0 stranded 8 solid 3/0 stranded 8 solid 4/0 stranded
HDC58 threads are 1/2 13 UNC. HDC58R threads are 7/16 14 UNC. * Not UL Listed Not CSA Listed
18
www.erico.com
Split Bolts
Silicon Bronze
High strength Silicon bronze for copper to copper connections. Tin plated, high strength copper alloy split bolt with spacer separates dissimilar conductors which allow you to connect: copper to copper; copper to aluminum; aluminum to aluminum. (Oxide inhibitor recommmended when used on aluminum conductor.) UL Listed
Rod Diameter Conductor Range (in) (AWG) 1/2, 5/8 1/2, 5/8
Minimum Torque
Rebar Size #4 #4
Standard Package 50 50
* With 9/16 bolt head UL Listed for direct burial in earth or concrete.
Part No. Silicon Bronze ESB8 ESB6 ESB4 ESB2 ESB1/0* ESB2/0* ESB4/0* Tin-Plated Silicon Bronze ESBP8* ESBP6* ESBP4* ESBP2* ESBP1/0* ESBP2/0* ESBP4/0* ESBP350* * Not UL Listed
Conductor Range (AWG) 16 stranded 8 stranded 10 solid 6 stranded 8 solid 4 solid 6 solid 2 stranded 4 solid 1/0 stranded 2 solid 2/0 stranded 1/0 solid 250 MCM 14 stranded 8 stranded 10 stranded 6 stranded 8 solid 3 stranded 8 solid 2 stranded 6 solid 1/0 stranded 8 solid 2/0 stranded 4 stranded 250 MCM 3/0 stranded 350 MCM
Conductor Range (AWG) 4 Solid - 2/0 Stranded 2/0 Solid - 250 MCM Stranded 2/0 Solid - 250 MCM Stranded
www.erico.com
19
CWP1JU
CWP2JU*
High-strength silicone bronze High-strength silicone bronze Used for connecting copper conductors to metallic water pipe, ground rods, or flexible gas pipe (CSST) with brass hex fittings Conform to the requirements of the 2009 edition of NFPA 54, NFGC (National Fuel Gas Code) and NEC (National Electric Code) for bonding corrugated stainless steel tubing (CSST) gas piping systems to the grounding conductor of the buildings electrical system SH version for outdoor applications cULus Listed
Part No. CWP1J CWP2J CWP3J CWP1JSH CWP2JSH CWP3JSH Water Pipe Size (in) .5 1 1.25 2 2.5 4 .5 1 1.25 2 2.5 4 Conductor Range (AWG) 10 solid 2 solid 10 solid 2 stranded 10 solid 4 stranded 10 solid 2 solid 10 solid 2 stranded 10 solid 4 stranded Hex Nut Size (in) 1 1.25 1.5 2.125 2.5 3.125 1 1.25 1.5 2.125 2.5 3.125 Standard Package 25 12 4 25 12 4 Part No. ZWP1J Water Pipe Size (in) .5 1 Conductor Range (AWG) 10 solid 6 solid Standard Package 25
Used for connecting copper conductors to metallic water pipe or ground rods CSA Listed
Part No. CWP1JJ CWP1JU* CWP2JU* CWP6J CWP4J** Water Pipe Size (in) .5 1 .5 1 1.25 2 4.25 6 2.5 4 Conductor Range (AWG) 10 solid 4 stranded 10 solid 2 stranded 10 solid 2 stranded 10 solid 4 stranded 10 solid 4 stranded Standard Package 100 1 1 1 1
* With copper screw for use in direct burial applications ** UL Listed Not CSA Listed
20
www.erico.com
Conductor Range (AWG) 10 solid 6 solid 10 solid 2/0 stranded 10 solid 2/0 stranded 10 solid 2/0 stranded 10 solid 3/0 stranded
Made from high copper-content alloy Theft-deterrent appearance Stainless steel nuts, bolts and washers included
Part No. Single Hole FC073 FC074 FC075 FC076 FC078 FC079 FC080 FC082 Dual Hole Standard Package 25 25 FC076 DH FC078 DH FC082 DH 1-1/2 1-1/2 2 2 2-1/2 3 3 3-1/2 2 2-1/2 3-1/2 4 Solid - 2/0 Stranded 2/0 Solid - 250 MCM Stranded 4 Solid - 2/0 Stranded 2/0 Solid - 250 MCM Stranded 2/0 Solid - 250 MCM Stranded 4 Solid - 2/0 Stranded 2/0 Solid - 250 MCM Stranded 4 Solid - 2/0 Stranded Pipe Size (in) Conductor Size (AWG)
VC62
VC220
2 x 2/0 Solid - 250 MCM Stranded 50 - 120 Stranded 2 x 2/0 Solid - 250 MCM Stranded 16 - 120 Stranded 2 x 4 Solid - 2/0 Stranded 16 - 120 Stranded
www.erico.com
21
CC207SIJ Conductor Range (AWG) 10 solid 2/0 stranded 6 solid 1/0 stranded 6 solid 1/0 stranded 6 solid 1/0 stranded 2/0 stranded 4/0 stranded Stud Thread Size 1/2 13 1/2 13 1/2 13; 1 long 1/2 13; with jam nut 1/2 13 Standard Package 100 50 50 50 25
CC207SIJ CC2074/0
KUL
22
www.erico.com
Standard Package 50
Bonds the frames and mounting structures of solar photo voltaic systems in accordance with NEC requirements
Copper alloy is corrosion resistant and galvanically compatible with copper grounding conductors and aluminum photo voltaic module frames Lay-in feature allows for easy positioning along multiple frames cULus Listed
Part No. EL6CS EL6CS8 EL6CSNH EL6CSDB Description Tinned Bronze Lug with #10 Hardware Tinned Bronze Lug with #8 Hardware Tinned Bronze Lug without Hardware Direct Burial - Tinned Bronze Lug with #10 Hardware Direct Burial - Tinned Bronze Lug with #8 Hardware Direct Burial - Tinned Bronze Lug without Hardware Conductor Range (AWG) #14 Sol - #6 Str #14 Sol - #6 Str #14 Sol - #6 Str #14 Sol - #6 Str #14 Sol - #6 Str #14 Sol - #6 Str
Ideal for residential and small commercial applications Meets requirements of 2008 NEC Article 250.94 cULus Listed
Conductor Range (5) 14 Solid - 6 Stranded; (1) 6 Solid - 2 Stranded; (5) 1.5 - 25mm2; (1) 16 - 35 mmm2
Standard Package 10
ATEX approved
The PEC is an equipotential bonding device that can be used to minimize damage in applications where separated ground systems are required. The PEC is ATEX approved, making the device suitable for use in explosion hazard areas such as the protection of pipeline insulated joints.
www.erico.com
23
Interconnects and terminates grounding conductors from electrical power service, telephone, CATV, radio and TV antennas
EL6CSDB8 EL6CSDBNH
UL Name Plate
CADWELD Connections:
Permanently bond all elements of the grounding system.
Pigtails
Factory attached conductor connection. Upward or downward orientation available.
Bentonite Clay
Electrolytic Roots
Typical vertical installation showing major components required to form an effective ground electrode.
ECR V 10 Y4 4 U B
ERICO Ground Electrode System (V) Vertical Style (H) Horizontal Style (E) Extended Vertical Electrode Length (in feet) Pigtail Cable Code Add (B) for rod assembly only Pigtail Orientation (D) Down (U) Up Pigtail Length (in feet)
Available in continuous sections up to 10 feet in length; longer rods can be field assembled using 5- or 10-foot extensions Optional factory attached radial strips are available to reduce impedance to highfrequency lightning energy and to control the direction of the dissipation L-shaped rods are available for horizontal installation applications where it is impractical to auger deep vertical holes Access segment on horizontal (L-shaped) chemical ground electrodes is 32 deep Over 100 configurations available
Chemical ground rods can be ordered as individual components or as a complete kit. Kits include the chemical electrode (pre-filled with electrolytic salts), Bentonite, GEM backfill, and an access well. To order the chemical electrode only, add B to the end of the part number.
24
www.erico.com
Vertical Installation
Horizontal Installation
Vertical Installation
Chemical Ground Electrodes can be installed either vertically or horizontally. Chemical electrodes are available in a range of standard and custom configurations. They can be purchased individually or part of a complete kit.
* Includes rod assembly only. * All chemical ground rod kits contain the following components, except part numbers ending in B. * Contact ERICO for additional configurations.
Kit Components
Part No. GEM25A BENTFILL T416B Description 25 lb (11.36 kg) bag of GEM Ground Enhancement Material 50 lb (22.68 kg) bag of Bentonite backll High-density polyethylene inspection well for no trafc areas
Vertical Installation
Salt Mix
Part No. ECRCHM15LB Description Chemical Ground Rod Salt Mix, 15-lb package (6.8 kg)
www.erico.com
25
26
www.erico.com
GEM is effective
Dramatically reduces earth resistance and impedance measurements Maintains constant resistance for the life of the system once in its set form Performs in all soil conditions even during dry spells
Part Number
GEM25A GEM25ABKT
Description
25-lb. (11.36 kg) bag with handles 25-lb. (11.36 kg) plastic bucket with locking lid
For more information, contact your local ERICO sales representative for a quote. You can reference the GEM part numbers.
GEM is permanent
Does not dissolve, decompose or leach out with time Does not require periodic charging treatments or replacements Does not require maintenance Does not require the continuous presence of water to maintain its conductivity
www.erico.com
27
ERICO provides 25 lbs of Ground Enhancement Material (GEM) in a convenient, easy to handle bucket container. Just pour the required amount of clean-potable water into the bucket and mix to create a slurry form. Then proceed to pour the slurry mixture into the hole or trench.
1 (2.5 cm)
GEM
GEM
1 (2.5 cm)
Note 1: Wait for the GEM to harden, about 15 to 20 minutes, before placing the conductor on top of the GEM. You must apply 4 inches (10 cm) of insulating material to the conductors and ground rods exiting the GEM, starting 2 inches (5 cm) inside the GEM. Note 2: Excess standing water must be removed from trench.
Soil Backll
Estimated linear feet of ground conductor covering with each bag of GEM.
Total Thickness of GEM
Trench Width In (Cm) 4 (10.0) 6 (15.2) 8 (20.3) 10 (25.4) 12 (30.5) 1 in (2.54 cm) 14.0 ft 9.3 ft 7.0 ft 5.6 ft 4.7ft 35.6 cm 23.6 cm 17.8 cm 14.2 cm 12 cm 2 in (5.08 cm) 7 ft 4.7 ft 3.5 ft 2.8 ft 2.3 ft 17.8 cm 12 cm 8.8 cm 7.0 cm 5.8 cm 3 in (7.62 cm) 4.7 ft 3.1 ft 2.3 ft 1.9 ft 1.6 ft 12 cm 7.8 cm 5.8 cm 4.8 cm 4 cm 4 in (10.16 cm) 3.5 ft 2.3 ft 1.8 ft 1.4 ft 1.2 ft 8.8 cm 5.8 cm 4.6 cm 3.6 cm 3 cm
A 25-pound bag of GEM will cover 7 linear feet (2.1 m) of conductor length for a 4-inch-wide (10 cm), 2-inch-thick (5 cm) covering 1 inch (2.5 cm) below and 1 inch (2.5 cm) above conductor), based on a density of 63.5 lb/cu.ft.
28
www.erico.com
6 (15.2 cm)
6 (15.2 cm)
Note 1: 4 inches (10 cm) of insulating material should be applied to the conductors and ground rods exiting the GEM, starting 2 inches (5 cm) inside the GEM. Note 2: Excess standing water must be removed from the hole.
Soil Backll
Estimated bags of GEM for backlling around ground rods to a density of 63.5 lb/ft 3
Depth of Hole*
Diameter of Hole In (Cm) 3 (7.6) 4 (10) 5 (12.7) 6 (15.2) 7 (17.8) 8 (20.3) 9 (22.8) 10 (25.4) 6 ft (1.83 m) 2 bags 2 bags 3 bags 5 bags 6 bags 8 bags 10 bags 12 bags 7 ft (2.13 m) 2 bags 3 bags 4 bags 5 bags 7 bags 9 bags 12 bags 14 bags 8 ft (2.44 m) 2 bags 3 bags 4 bags 6 bags 8 bags 11 bags 13 bags 16 bags 9 ft (2.74 m) 17 ft (5.18 m) 19 ft (5.79 m) 20 ft (6.10 m) 2 bags 3 bags 5 bags 7 bags 9 bags 12 bags 15 bags 18 bags 4 bags 6 bags 9 bags 13 bags 17 bags 22 bags 28 bags 34 bags 4 bags 7 bags 10 bags 14 bags 19 bags 25 bags 31 bags 38 bags 4 bags 7 bags 10 bags 15 bags 20 bags 26 bags 32 bags 40 bags
* 8-foot (2.44 m) minimum rod length required to be in contact with the soil (or GEM), per NEC 250-83-C. Note: To mix GEM into a slurry form, use a standard cement mixer or mix in a mixing box, wheelbarrow, etc. Use 1.5 to 2 gallons (5.7 to 7.6 liters) of clean-potable water per bag of GEM. Do not mix GEM with salt water. For storage and safety precautions, see product packaging.
www.erico.com
29
Grounding Accessories
Light Weight Polymer Concrete Inspection Wells
C A
GroUNdiNg accessories
T416F
T416BH
PIT03
PIT05
T416C Cover Weight of Box Base Weight (lbs) with Inserts (lbs) 1.5 3 WGRS200 Part No. PIT03 Includes locking pin and key PIT05 UV-stabilized against degredation by sunlight; non-brittle to prevent cold weather damage WGRS200 Double ange earth seal with PIT05 IP900C Concrete Inspection Pit IP900C Dimensions (in)
length x width x depth
Stainless steel lock bolt ( 3/8 16 x 1-3/4); boxes and covers nest in 3.25 increments; 2 knockouts per box (3.5 x 1.5); color: green T416BH 9.125 13 10.25 1.5 3 Includes 4 additional 1/2 bolts on cover. Stainless steel lock bolt ( 3/8 16 x 1-3/4); boxes and covers nest in 3.25 increments; 2 knockouts per box (3.5 x 1.5); color: green T416C 11 24.5 Pipe slot (2 places); color: black T416CKEY: Key for T416C Inspection Well 18.25 4.2 13.4
30
www.erico.com
Ground Plates
Pigtail Pigtail Connection Cable Type Type Plate Width
Pigtail Length
Terminated Pigtails
Part Number:
Ground Plate Electrode Material Pigtail Connection Type Plate Thickness Code
(Stock Tolerance)
Plate Length
Pigtail Length
Through Pigtail
Example: GPECEAH0241L024
Material A B C D Steel (HRS M1020) Stainless Steel (SS304) Copper (C11000) Galvanized Steel C E N
Pigtail Connection Type Continuous (2 x L J ERICO Conn.) End (L J ERICO Conn. Style) No Pigtail Plate Thickness Code
Part No. GPECEAH0241L024 GPECEAH0241T024 GPECEAH0242Q024 GPECEAJ0181G024 GPECEAJ0182Q024 GPECEAJ0241G024 GPECEAK0241G024 GPECEAK0241H024 GPECEAK0241T024 GPECEAK0241V024 GPECEAK0241Y024 GPECEAK0242G024 GPECEAK0242Q024 GPECEAK0242V024 GPECEAM0362Q024 GPECEAP0481H024 GPECEBH0121V024 GPECEBH0122G024 GPECEBH0241K024 GPECEBH0242G024 GPECEBH0242L024 GPECEEK0242Q060 GPECEEK0361T024
Thickness Width Length Cable (in) (in) (in) Code 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/16 1/16 1/16 1/16 1/16 1/4 1/4 12 12 12 18 18 18 24 24 24 24 24 24 24 24 36 48 12 12 12 12 12 24 24 24 24 24 18 18 24 24 24 24 24 24 24 24 24 36 48 12 12 24 24 24 24 36 1L 1T 2Q 1G 2Q 1G 1G 1H 1T 1V 1Y 2G 2Q 2V 2Q 1H 1V 2G 1K 2G 2L 2Q 1T
Cable Size #4 Stranded #2 Solid 4/0 Stranded #6 Solid 4/0 Stranded #6 Solid #6 Solid #6 Stranded #2 Solid #2 Stranded #1 Stranded 2/0 Stranded 4/0 Stranded 250 MCM Stranded 4/0 Stranded #6 Stranded #2 Stranded 2/0 Stranded #4 Solid 2/0 Stranded 3/0 Stranded 4/0 Stranded #2 Solid
A B C D E F G H J
1/32 (Min. for Lightning Cu) 1/16 (Min. for Power Cu) 3/32 1/8 1/4 (Min. for Power Stl.) 3/8 1/2 1/64 (26 Gauge) 3/16
www.erico.com
31
GroUNd Plates
Ground Plates
Copper Ground Plates with Welded, Through Pigtails Copper Utility Pole Bottom Plates
Part No. GPECCAH0242Q024 GPECCAJ0181V024 GPECCAJ0242Q024 GPECCAJ0361L024 GPECCAK0241L024 GPECCAK0241T024 GPECCAM0362C024 GPECCAM0362Q024 GPECCBH0122Q024 GPECCBH0242G024 GPECCEK0242C036
Thickness Width Length Cable (in) (in) (in) Code 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/32 1/16 1/16 1/4 12 18 18 18 24 24 36 36 12 12 24 24 18 24 36 24 24 36 36 12 24 24 2Q 1V 2Q 1L 1L 1T 2C 2Q 2Q 2G 2C
Cable Size 4/0 Stranded #2 Stranded 4/0 Stranded #4 Stranded #4 Stranded #2 Solid 1/0 Stranded 4/0 Stranded 4/0 Stranded 2/0 Stranded 1/0 Stranded
Pigtail Length (in) 24 24 24 24 24 24 24 24 24 24 36 EGP100 Part No. EGP100 EGP100HL Description Utility Pole-Bottom Plate with Lug* Utility Pole-Bottom Plate with ERITECH HAMMERLOCK Connector EGP100HL Thickness (in) .025 .025 Diameter (in) 7.5 7.5 Conductor Size Range #14 Solid #4 Stranded #14 Solid #4 Stranded
* RUS Approved
Width (in) 17
Length (in) 17
Cable Code 1G
Description Utility Ground Plate with SRGC46 Connector* Utility Ground Plate with Connector, quantity of 5 per package Utility Ground Plate with ESB2 Split Bolt Utility Ground Plate with SRGC46 Connector* Utility Ground Plate with SRGC46 Connector, quantity of 5* Utility Ground Plate with ESB2 Split Bolt
GroUNd Plates
UGP738 UGP738P5 Part No. GPECNAK024 GPECNDF006 GPECNEB024 GPECNEK024 GPECNEM040 Thickness (in) 1/32 1/8 1/4 1/4 1/4 Width (in) 24 6 2 24 36 Length (in) 24 6 24 24 40 UGP738SBP5
* SRGC46 Connector (for Signal Reference Grids) can be used for #4 solid #6 stranded AWG.
Copper ground plates made from 20 gauge thick, high conductivity copper sheet Cable attachment (LPC535L) securely fastened to plate
Part No. Thickness (gauge) Width (in) Length (in) Number of Cable Attachments LPC750 20 12 24 2 LPC751 20 18 18 2 LPC752 20 36 36 2 LPC753 LPC754 LPC755 20 20 20 12 18 36 24 18 36 1 1 1
Description Galvanized Steel Ground Plate, without Connector Galvanized Steel Ground Plate, with HDC58 Connector
Width (in) 10 10
Length (in) 16 16
32
www.erico.com
Equipotential Bonding
PGS 30-33
GROUNDING BUSBARS
PGS 41-45
PG 38
GROUND PLATES
PGS 52-53
SRG
PGS 54-56
BONDING STRAPS
www.erico.com
33
EQUIPOTENTIAL BONDING
FENCE ASSEMBLY
Proper bonding is essential to create an equipotential plane between service grounds and equipment during fault and transient conditions. This equipotential plane provides a near zero voltage differential and serves to protect people and equipment during these events. The most popular bonding product in use today is the ground bar or bonding bar. Ground bars provide a convenient, single-point grounding and bonding location. Conductors are welded to the bar
using a CADWELD exothermic connection or are mechanically fastened by using lugs. ERICO can design and manufacture custom bars. In addition, the breadth of the product offering includes TMGB bars, which meet the requirements of TIA/ EIA 607 and conform to BICSI recommendations. Our perimeter bus system allows for fast and easy field installation of halo and other perimeter grounding schemes.
2 2 2
2 2 2 2 2
7 77 7 16 / 16 16 //7 7 16 / 16 //16
2 2 2 2 2 2
3 334 4 4
/ //
2 2 2
1 1 1 2 2
1 1 1 1 21
PATTERN AA PATTERN: " AA" PATTERN: PATTERN: " AA" " AA"
7 77 7 7 16 7 7 16 16 16 16 16 16
PATTERN BB PATTERN: " BB" PATTERN: PATTERN: " BB" " BB" PATTERN: " AA" PATTERN: " AA"
1 11 11 /88 /18/ Typ. Typ. Typ. 3 4
PATTERN CC PATTERN: " CC" PATTERN: PATTERN: " CC" " CC" BB" PATTERN: " BB" PATTERN: " AA"
1 1 11 /8 /8 Typ. Typ.
PA PAT PA PA P PAT
1 1/ 8 Typ.
3 4
/ / // ///
2 2 2 2 2 2 2
#6 32 32 #6 #6 32 7 9 99 2 7 77 7 16 2 32 32 32 16 16 2 16 16 3 334 22 4 4
/ / / / / / //
/ //
1 1
2 21 1
1 1 1 1 1
PATTERN: " CC" PATTERN DD PATTERN: " DD" PATTERN: " AA" PATTERN: " AA" EE" PATTERN: PATTERN: " EE" " EE"
7 77/ 16 7 16 /716 / 7 7 / 16 / 16 / /1616
PATTERN: " DD" PATTERN " EE PATTERN: BB" PATTERN: " BB" PATTERN: " FF" PATTERN: FF" " FF" EE" PATTERN: " EE"
1 11 1 /8 /8 Typ. Typ. 3 334 4 4 7 77/7 1#6 16 1 1 /16 / 16 7 32 32 1 /7 16 / 9 1 9 1#6 /16 16 33 / 32 / 32 33 /4 /3/ 4 /4 /4 4
PATTERN FF PATTERN: " CC" PATTERN: " CC" PATTERN: " GG" PATTERN: " GG" GG" FF" PATTERN: " FF" PATTERN: " EE"
7 77 7 7 / 16 5 55/ 1 / 16 /7 16 1 16 / /16 1 16 77 /16 /16 / 1 1 1 1 /16 /16 16
32
3 4
1 1 1 2 2 11
/ //
3 3 44
//
1 1
1 1
1 1 1
1 1 1 1 1 11
PATTERN: " JJ" PATTERN GG PATTERN: PATTERN: " JJ" " JJ" PATTERN: " GG" PATTERN: " HH" PATTERN: " EE" PATTERN: " EE"
EQUIPOTENTIAL BONDING
3 4
PATTERN: " LL" PATTERN HH PATTERN: PATTERN: " LL" " LL" PATTERN: " JJ" PATTERN: " JJ" HH" PATTERN: " FF" PATTERN: " FF"
77 /16 /16 3 3 44
PATTERN: " M M " PATTERN JJ PATTERN: PATTERN: " M " M M M " " LL" PATTERN: " LL" PATTERN: " JJ" PATTERN: " GG" PATTERN: " GG"
3 3 44
7 7 7/ 16 /16 /16
2 5/16 1 1 1
1 1
//
3/4
//
77 /16 /16
55 /16 /16
1 1 1 1 1 1
1 1
1 1
PATTERN: " MM" PATTERN KK NN" PATTERN: " JJ" PATTERN: " JJ"
PATTERN LL PATTERN: " NN" PATTERN: " LL" PATTERN: " LL"
PAT PA
34
www.erico.com
3 4
7/16
C"
PATTERN:" DD"
7/16
G"
PATTERN:" HH"
GroUNdING BUS BARS
1
1 1 1
7 7 /16 /16
/ /
M"
3 4 7/8 7/8
3/4
7/8
3 /4
"
PATTERN SS
PATTERN CCSKY
PATTERN CIGBE
PATTERN HIG
PATTERN TES
www.erico.com
35
EQUIPOTENTIAL BONDING
E G B A1 4 4 1 2 C C
Pig Tail Length Ft. (Empty if none)
A = 1 E = 5 J = 9 N = 16 S = 24 W = 32 B = 2 F = 6 K = 10 O = 17 T = 25 X = 34 C = 3 G = 7 L = 11 P = 18 U = 26 Y = 36 D = 4 H = 8 M = 12 Q = 19 V = 27 Z = 38
Conguration
A = Insul & Brkt C = None (Bar only) B = Brkt only D = Insul only
(Empty if none)
EQUIPOTENTIAL BONDING
Width
1 = 1 2 = 2 3 = 3 4 = 4 7 = 7 5 = 5 8 = 8 6 = 6 9 = 9
36
www.erico.com
7/16
3 4 7/8 7/8
Part No. 1 wide bar EGBA14112EE 2 wide bar EGBA14212BB EGBA14212EE EGBA14212HH EGBA14212NN EGBA14215JJ EGBA14224GG EGBA14224NN 4 wide bar EGBA14410FF EGBA14412AA EGBA14412BB EGBA14412CC EGBA14412GG EGBA14412LL EGBA14412NN EGBA14420CC EGBA14420NN EGBA14424CC EGBA14424LL EGBA14424MM EGBA14424NN
Thickness (in) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Width (in) 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4
Length (in) 12 12 12 12 12 15 24 24 10 12 12 12 12 12 12 20 20 24 24 24 24
Hole Pattern EE BB EE HH NN JJ GG NN FF AA BB CC GG LL NN CC NN CC LL MM NN
PATTERN: "PP"
Part No. EGBA14412QQT EGBA14420QQ EGBA14420QQT EGBA14424QQ EGBA14424QQT Thickness (in) Width (in) 1/4 1/4 1/4 1/4 1/4 4 4 4 4 4
PATTERN: "QQ"
Length (in) 12 20 20 24 24 Hole Pattern QQ QQ QQ QQ QQ Plating Tinned Copper Tinned Copper Tinned
Pattern QQ
PA
QQ Pattern, Copper & Tinned Copper Grounding Bus Bars (Bar only)*
Part No. EGBC14412QQT EGBC14424QQT EGBC14420QQ EGBC14424QQ EGBC14412QQ Conguration Bar only Bar only Bar only Bar only Bar only Thickness (in) 1/4 1/4 1/4 1/4 1/4 Width (in) 4 4 4 4 4 Length (in) 12 24 20 24 12 Hole Pattern QQ QQ QQ QQ QQ Plating Tinned Copper Copper Copper
* Tinned bars with QQ hole pattern are electro-tin plated after holes are punched.
* Also available using pre-tinned copper bar. Add T to the part number.
Mounting Kits
Include stainless steel hardware, 3/8 fasteners, insulators and brackets cULus listed
Part No. B548A39* B548A41 B548A42 * Not UL Listed Description Mounting kit for steel beam Mounting kit for 1 & 2 wide bars Mounting kit for 3 & 4 wide bars
www.erico.com
37
EQUIPOTENTIAL BONDING
Tinned
29 18 PAIR 5/16 29 5/8 2 2 2 5/8 5/8 1 1 1 5/8 5/8 5/8 18 PAIR 5/16 18 PAIR 1 15/16 / 8 TYP 18 PAIR 5/16 1 TYP 8 29 29 18 29 18 24 18 29 24 18 24 18 24 18 18 24 20 18 5 PAIR 7/16 18 PAIR 5/16 18 PAIR 5/16 5 PAIR 7/16 18 PAIR 5/16 5 PAIR 7/16 1 1/ 8 TYP 5 PAIR 17/16 1 TYP /8 18 PAIR 5/16
1 1/ 8 TYP 5 PAIR 7/16 18 PAIR 7/16 5/16 5 PAIR 14 PAIR 5/16 1 PAIR 5/16 5 18 PAIR / 8 TYP 7/16 14 PAIR 5/16 5 PAIR 7/16
1
29 29 29 29 5 PAIR 7/16 1 5 PAIR 7/16 5 PAIR 7/16 29 18 5 PAIR 7/16 18 29 24 18 29 24 24 18 4 5/8 1 5/8 4 5/8 5/8 1 4 4 4 5/8 1 5/8 1 5/8 5/8 41 PAIR 5/16 1 1/ 8 TYP 41 PAIR 5/16
1 1/ 8 TYP
5 PAIR 7/16 41 PAIR 5/16 5 PAIR 41 PAIR 7/16 5/16 41 PAIR 5/16 5 PAIR 7/16
29 29 29 5 PAIR 7/16 5 PAIR 7/16 5 PAIR 7/16 29 18 24 18 29 18 24 29 24 18 24 18 18 24 18 20 18 24 20 20 18 PAIR 7/16 7/16 53PAIR PAIR 7/16 7/16 53PAIR 3 PAIR 7/16 5 PAIR 7/16 5 PAIR PAIR 7/16 7/16 5 5 PAIR 7/16 5 PAIR 7/16 5 PAIR 7/16 5 PAIR 7/16
5/8
1 / TGBA29L18PT
4 5/8 TMGBA29L41PT 5/8 5/8 4 1 5/8 1 4 1 4 5/8 5/8 1 4 5/8 5/8 4 5/8 1 5/8 4 4 5/8 1 5/8 5/8 5/8 1 4 4 5/8 5/8 1 4 5/8 5/8 1 4
11
5/8
5 PAIR 7/16 5 PAIR 7/16 5 PAIR 7/16 5 PAIR 7/16 5 PAIR 7/16
33PAIR PAIR 5/16 5/16 41 1 1/ 8 TYP 33PAIR PAIR 5/16 1 1 141 / 8 TYP 5/16
5/8 2 5/8 2 2 2 1 5/8 2 2 1 1 1 5/8 5/8 5/8 1 1 5/8 2 5/8 2 2 1 1 1 5/8 5/8 5/8
1 1/ 8 TYP
18 24 18 18 18 24 20 18 24 20 20 18 5 PAIR 7/16
5/8 2
5/8 2 2 2
1 1/ 8 TYP 1 TYP 1 12 PAIR 5/16 145/16 PAIR 5/16 PAIR 5/16 514 PAIR 7/16 /8 12 PAIR 3 PAIR 7/16 1 5/8 18 20 2 1 5/8 12 PAIR 5/16 1 1 / 8 TYP 3 PAIR 7/16 112 PAIR 5/8 5/16 1 1/ 8 TYP 1 1/ 8 TYP 2 1 5/8 20 18
53 PAIR PAIR 7/16 7/16 PAIR 7/16 7/16 53 PAIR 3 PAIR 7/16
5/8 1 5/8 33 PAIR 5/16 1 5/8 4 5/8 1 1/ 8 TYP 24 1 5/8 5/8 18 33 PAIR 5/16 18 5/8 5/8 4 5/8 1 TYP 24 1 5/8 /8 20 18 18 1 27 PAIR33 PAIR 5/16 5/16 4 1 1/ 8 TYP 24 5/8 18 20 5/8 33 PAIR 27 PAIR 5/16 5/16 11 1 / 8 TYP 4 5/8 1 27 PAIR 5/16 5/8 1 5/8 1 5/8 4 1 / 8 TYP 4 5/8 1 27 PAIR 5/16 5/8 5/8 4 5/8 4
1
33 PAIR 5/16 PAIR 41 7/16 7/16 55PAIR PAIR 5/16 1 1/ 8 TYP 33 PAIR 5/16 5 PAIR 7/16
1 1 TYP 1 1 88 TYP 5 PAIR 7/16
//
53 PAIR 7/16 1 1/ PAIR 7/16 8 TYP 27 PAIR 33 PAIR 5/16 5/16 27 PAIR 33 5/16 PAIR 5 PAIR 3 PAIR 7/16 7/16 5/16 1 1/ 8 TYP 27 PAIR 5/16 3 PAIR 7/16
18 20
12 PAIR 5/16 2 1 5/8 1 1/ 8 TYP 10 PAIR 5/16 12 PAIR 5/16 2 1 5/8 10 PAIR 5/16 TGBA20L12PT 5/8 12 PAIR 5/16
2 1 2 1 2 2
1 5/8 1 5/8 1 1
3 PAIR 17/16 9 1 / 8 TYP 12 PAIR 5/16 3 17 1 1/ TYP 20 8 18 / 4 3 PAIR 7/16 3 PAIR 7/16 9 10 PAIR 5/16 1 1/ 8 TYP 123 PAIR 5/16 17 20/ 4 5/16 9 10 PAIR 3 PAIR 7/16 12TYP PAIR 35/16 PAIR 7/16 1 1/ 8 17 3/ 4 10 PAIR 5/16 9 3 PAIR 7/16 1 1 8 TYP 3 1 1//17 /4 8 TYP
1 1/ 8 20 TYP 18
4 3 PAIR 7/16 4 3 PAIR 7/16 3 PAIR 7/16 3 PAIR 7/16 3 PAIR 7/16 3 PAIR 7/16 5/8 1 5/8 5/8 5/8
1
9 / 8 TYP 18 3 17 /4 20 9 1 1 TYP
11
/8
17 3/ 4 9 20
17 3/ 4 1 1/ 8 TYP
2 1
1 5/8
5/8
2 1 2 2
1 2 1 2 2
5/8 1
5/8
EQUIPOTENTIAL BONDING
5/8 1 1
5/8 5/8
TGBA16L08PT
2 1 5/8
5/8
5/8
TGBA12L06PT
3 PAIR 7/16 9 9 10 PAIR 5/16 1 1/ 8 3 TYP 15 1 17 1 1/ //42 8 TYP 8 PAIR 5/16 3 PAIR PAIR 7/16 7/16 10 PAIR 9 5/16 3 8 PAIR 5/16 1 1/ 8 9 TYP 10 PAIR 5/16 2 1 5/8 1 3 15 17 // 2 94 8 PAIR 5/16 8 PAIR 5/16 3 PAIR 7/16 10 PAIR 5/16 10 PAIR 5/16 1 1/ 8 TYP 3 PAIR 7/16 15 1/ 2 1 1/ 8 TYP 1 5/8 2 1 15 8 PAIR 5/16 /2 2 1 5/8 9 8 PAIR 5/16 3 PAIR 7/16 9 1 5/8 1 2 111/ 8 TYP 1 / 815TYP 2 1 5/8 11 /2 8 TYP 1 1 1/ 15 / 8 TYP /2 8 PAIR 15/16 3 PAIR 7/16 99 2 5/8 8 PAIR 5/16 9 1 1/ 8 9 TYP 111/ 8 TYP TYP 1 TYP 1 1 1 /15 8 /2 /8 12 1 9 8 PAIR 5/16 1 1/15 TYP 3 PAIR 7/16 /2 129 8 99 38PAIR 6 5/161 1/ 8 TYP PAIR 7/16 5/16 2 PAIR1 5/8 6 PAIR 5/16 9 1 1 12 / 2 15 15 /2 12 9 PAIR 8 PAIR 5/16 1 1/ 8 TYP 3 8 5/16 PAIR 7/16 6 PAIR 5/16 1 3 PAIR 7/16 6 PAIR 5/16 1 /8 12TYP 1 5/8 2 1 5/8 2 12 9 6 PAIR 5/16 9 3 PAIR 7/16 6 PAIR 5/16 1 1/ 8 TYP 1 5/8 2 1 TYP 1 15/8 2 /12 8 11 TYP 1 1/ 12 /8 8 TYP 9 3 PAIR 7/16 6 PAIR 1 5/8 9 2 5/16 9 6 PAIR 5/161 1 9 1 1/ 8 TYP TYP 1 1/ /8 8 TYP 1 1/ 8 TYP 12 9 129 9 3 PAIR 7/16 1 1/ 8 TYP 6 PAIR 5/16 1 TYP 1 15/8 6 PAIR 5/16 2 /8 9 12 12 9 7/16 6 PAIR 5/16 1 1/ 8 TYP 3 PAIR 6 PAIR 5/16 1 1/ 8 TYP 1 5/8 2 9 9 1 TYP /8 1 1 5/8 2 1 1/ 8 TYP 9 9 1 1/ 8 TYP 1 1/ 8 TYP 9 9
9 1 1/17 3 8 TYP /4 1 1/ 8 TYP 9 1 1/ 8 TYP 9 1 1/ 8 TYP 1 159 3 2 //4 1 1/17 8 TYP 9 1 159 / 2 3 17 / 4
5/8 5/8 1
3 PAIR 7/16
4 5/8 5/8 5/8 1 5/8 4 4 5/8 1 5/8 5/8 5/8 1 1 4 5/8 5/8 5/8 5/8 1 1 4
3 PAIR 7/16 3 PAIR 7/16 3 PAIR 7/16 3 PAIR 7/16 3 PAIR 7/16
TMGBA18L23PT 4
3 PAIR 7/16 5/8 5/8 1 5/8 5/8 4 4 5/8 1 5/8 5/8 5/8 1 4 4 5/8 5/8 1 4 5/8 5/8 4 4
3 PAIR 7/16 3 PAIR 7/16 3 3 PAIR PAIR 7/16 7/16 3 PAIR 7/16
4 3 PAIR 7/16
TMGBA16L19PT
20TYP 1 1/ 8 1 1/ 8 TYP 18 3 PAIR 7/16 9 27 PAIR 5/16 1 1/ 8 TYP 5/8 1 1/ 8 TYP 1 1/20 8 TYP 5/8 18 3 27 PAIR 5/16 179 / 4 3 PAIR 7/16 1 27 23 PAIR 5/16 1 3 PAIR 5/16 7/16 1 / 8 TYP 4 23 PAIR 20 5/8 9 17 3/ 4 27 3 PAIR 5/16 7/16 27 PAIR 5/16 5/8 PAIR 1 1/ 8 TYP 3 PAIR 23 23 PAIR1 5/16 PAIR 7/16 1 4 9 3 17 4 23 PAIR / 4 5/8 1 23 PAIR 5/8 5/16 5/8 1 1 1 TYP 3 PAIR 7/16 /8 4 4 5/8 1 1 3TYP 17 9/ 5/8 4 /8 1 5/8 23 PAIR 5/8 5/16 3 PAIR 7/16 9 23 PAIR 4 5/8 1 1/ 8 TYP 5/8 1 31 1 TYP 15 /8 42 5/8 17 9 // 23 19PAIR PAIR 5/16 5/16 9 33 PAIR 7/16 PAIR 7/16 1 19 PAIR PAIR 23 4 1 1/ 8 TYP 31 15 17 42 5/8 9// 19 PAIR 19PAIR PAIR 5/16 5/16 23 23 PAIR 5/8 33 PAIR 7/16 PAIR 7/16 1 1 11 / 8 TYP 19 PAIR 15 1/ 2 4 4 9 19 PAIR 5/16 3 PAIR 7/16 1 5/8 1 5/8 5/8 15/8 1 4 1 TYP 15 4 1 1/ 8 /2 8 TYP 1 19 PAIR 5/8 5/16 5/8 3 PAIR 7/16 99 19 PAIR 4 5/8 5/8 5/81 1 1 15 /12 2 / 8 TYP 5/8 19 PAIR 5/16 15 PAIR 3 5/16 PAIR 7/16 1 99 3 PAIR 19 PAIR 7/16 4 1 1/ 8 TYP 1 12 15 5/89/ 2 PAIR 3 5/16 19 PAIR 5/16 15 5/8 PAIR 19 PAIR 7/16 1 3 PAIR 7/16 1 11 / 8 TYP 121 4 9 5/16 4 PAIR 15 5/8 5/8 1 5/8 1 3 PAIR 7/16 5/8 1 5/8 12 TYP 5/8 4 1 1/ 4 18 TYP 1 15 PAIR 5/16 / 8 1 3 PAIR 7/16 9 5/8 5/8 5/8 5/8 1 4 9 5/8 5/8 125/8 1 1/18 TYP 1 TYP 8 5/8 15/PAIR 5/16 5/8 9 1 9 1 3 PAIR 7/16 5/8 1 TYP 14 12 / 8 5/8 15 PAIR 5/16 5/8 9 5/8 1 5/8 3 PAIR 7/16 1 1 1/ 8 TYP 4 9 5/8 5/8 5/8 1 1 5/8 4 11 / 8 TYP 5/8 5/8 9 5/8 5/8
1 1/ 8 TYP
20TYP 1 1/ 8 18 3 PAIR 9 1 1 / 8 TYP 18 9 20 11 17 / 8 3TYP / 4 3 PAIR 5/16 9 3 PAIR 20 17 3/ 4 3 PAIR 5/16 3 PAIR 11 / 8 3TYP 17 /4 5/16 9 3 PAIR
1 1 8 TYP 3 17 11 4 89 TYP
7/16
5/16 3 PAIR 7/16 9 11 8 TYP 1 1/ / 89 TYP 1 3 2 159 17 /4 1 1/ 8 TYP 33 5/16 PAIR 7/16 7/16 5/16 PAIR 1 159 /4 2 17 3/ 5/16 3 PAIR 7/16 5/16 3 PAIR 7/16 15 1/ 2 1 1/ 8 TYP 5/16 3 PAIR 7/16 9
15 TYP 1 1 /2 11 //88 TYP 5/16 3 PAIR 9 1 TYP 1 1 / 8 1 / 8 TYP 1 12 9 159 /2 1 PAIR 115 5/16 / 8 TYP 35/16 3PAIR PAIR 912 15 1/ 2 15 PAIR 5/16 5/16 PAIR 33PAIR 12 1 PAIR 115 / 8 TYP 5/16 3 PAIR 9
1
/ / /
7/16
12 TYP 1 11 //88 TYP 1 15 PAIR 5/16 3 PAIR 7/16 9 9 1 1 TYP 11 //88 TYP 12 9 15 PAIR 5/16 1 1/ 8 TYP 3 PAIR 7/16 912 15 PAIR 5/16 3 PAIR 7/16
1 1/ 8 TYP
9
1 1/ 8 TYP
9
1 1/ 8 TYP
TMGBA12L15PT
38 www.erico.com
Connecting Clamps
BC FC
BC FC
553030 Part No. TMGBA12L15P TMGBA12L15PT TMGBA16L19P TMGBA16L19PT TMGBA18L23P TMGBA18L23PT TMGBA20L27P TMGBA20L27PT TMGBA24L33P TMGBA24L33PT TMGBA29L41P TMGBA29L41PT Thickness (in) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Width (in) 4 4 4 4 4 4 4 4 4 4 4 4 Length (in) 12 12 15.5 15.5 17.75 17.75 20 20 24 24 29 29 Tin Tin Tin Tin Tin Tin Plating 553040 553050 553060 553070 568700 568730
5.08 1.73
4.92 2.36
www.erico.com
39
EQUIPOTENTIAL BONDING
FC 100 x 32 3.97
4.29 1.73
4.92 2.36
1.47
E P G
PERIMETER GROUNDING BUS BARS ERITECH Perimeter Ground Designation Conguration
A = Insulator & Bracket C = Bar only
Length
Stock Length = 120 Bent Bars (Radius) = 6 x 6 Bent Bars (Flat) = 8 x 8
Thickness
18 = 1/8 14 = 1/4
Width
1 = 1 2 = 2 4 = 4
Example: A) 1/4 x 2 x 120 (straight bar) = EPGC142120 B) 1/4 x 2 x 6 x 6 (right angle corner) = EPGC1426X6
30 Spacing Typ. EPGC142120 (Typ) Note: Not all insulators and brackets are shown
EQUIPOTENTIAL BONDING
CADWELD Connection
EPGC1426X6 (Typ)
40
www.erico.com
Part No. EPGC141120 EPGC142120 EPGC142120T* EPGC142144 EPGC143120 EPGC144120 EPGC181120 EPGC182120 EPGC183144 EPGC184120
Thickness (in) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/8 1/8 1/8
Width (in) 1 2 2 2 3 4 1 2 3 4
Length (in) 120 120 120 144 120 120 120 120 144 120 Part No. EPGC1418X8FL EPGC1428X8FL EPGC1448X8FL EPGC1818X8FL EPGC1828X8FL EPGC1848X8FL
Length
Width
Thickness (in) 1/4 1/4 1/4 1/8 1/8 1/8 Width (in) 1 2 4 1 2 4 Length (in) 8 8 8 8 8 8
Part No. EPGC1236X6 EPGC1416X6 EPGC1426X6 EPGC1426X6T* EPGC1428X8 EPGC1436X6 EPGC1446X6 EPGC1446X6T* EPGC1816X6 EPGC1826X6 EPGC1846X6 * Tinned copper bar
Thickness (in)
FAA ground bars available in many sizes. Customer to provide: Ground bar size Hole pattern Plexiglass size Plexiglass markings
www.erico.com
41
EQUIPOTENTIAL BONDING
Part No.
Thickness (in)
Width (in)
Length (in)
Use a CADWELD mold (Type TA or Type SS) when connecting the ERITECH brand of cast ground plate to the ground conductor. The cast ground plate stud size noted above fits the mold opening for a cable of the same size. Reference CADWELD catalog (A1A) for more information. Examples: Tee connection of 250 cable to B1642Q (4/0 stud size), use mold TAC2V2Q. Splice connection of 250 cable to B1642Q, use mold SSC2Q2V.
2 1/ 2 1 1/ 2
2 1/ 4
Description Cast ground plate with 4/0 stud Cast ground plate with 500 MCM stud
1 5 8
1 3/ 4
3 1/ 4
Part No.
DB Series
B1622Q
EQUIPOTENTIAL BONDING
1 3/ 4
3 1/ 4
B (mm) 16 16 16
D (mm) 50 50 50
Description Cast ground plate with 4/0 stud Cast ground plate with 500 MCM stud
42
www.erico.com
Assemblies use equipment ground plate parts: B1612Q [A], B1613Q [B], B1622Q [C], B1642Q [D], and B1643Q [E] Custom lengths available; contact ERICO for details
Cable Code
#6 Solid = 1G #4 Stranded = 1L #2 Stranded = 1V 1/0 Stranded = 2C 2/0 Stranded = 2G 4/0 Stranded = 2Q 250 MCM Stranded = 2V 350 MCM Stranded = 3D 500 MCM Stranded = 3Q
B532
SS
B531 B530
RA TA
RB
B533
www.erico.com
43
EQUIPOTENTIAL BONDING
B530 A 2Q 72
Cable Length (inches)
Attachment Point 3/4 Ball Stud (Cover for B165, included) Removable 3/4 Ball Stud Removable 3/4 Ball Stud
Attachment Point 3/4 Diameter Bar (Cover for B166, included) 1.5 Diameter Bar (Cover for B167, included)
Diameter Maximum Standard (in) at Grade Diameter Packaging Level (B) (in) (C) Quantity 3-7/8 3-7/8 4-3/4 4-3/4 4-3/4 6-1/2 1 1 1 1
* Aircraft static grounding clamp B2617A can be used to connect to the B165, B165R, and B166.
1-1/2 5
1 10
EQUIPOTENTIAL BONDING
Plastic for making 3 x 6 x 2.5 deep depression in concrete pour around loop in aircraft tie-down.
44
www.erico.com
Welded Connections
Welded connections are often specified because they are the only connections proven to assure a noisefree bond. Normal shock and vibration jar mechanical connections, creating electronic noise. This causes relatively high Ldi/dt voltages, due to a sudden change in connection impedance. This sudden change can result in pulses which can be coupled onto the signal circuits. These unwanted signals can create false data or even cause permanent circuit damage. Corrosion, dirt and cleaning fluids cannot interfere with the molecular bond of a welded joint.
www.erico.com
45
EQUIPOTENTIAL BONDING
Low impedance riser equipment bond, with CADWELD connection to SRG Concrete Floor Slab
Power Center
CADWELD connection #6 AWG to pedestal CADWELD connection #6 AWG to SRG Signal Reference Grid (SRG) Pre-engineered copper strip sections CADWELD exothermic Type TW welded connections
CADWELD connection #6 AWG to SRG CADWELD connection between adjacent SRG sections
EQUIPOTENTIAL BONDING
All equipment shall be bonded to the ERITECH brand of SRG using low impedance risers. Never connect to strip closest to outside wall.
All columns, conduits, water pipes, ducts, etc. entering the computer room shall be bonded to the SRG (at each end of the room if these are horizontal).
Power distribution panels and power distribution center should be mounted directly to the building steel or All raised floors within the computer room should be bonded to it by a short length of grounding conductor bolted stringer type. equal to the green wire ground but at least #4 AWG copper. The grounding wire inside any panel or Every sixth raised floor pedestal in each direction shall be enclosure supplying AC power to the computer must be connected to the SRG using a #6 AWG concentric copper bonded to its enclosure. conductor. The connection to both thepedestal and the SRG shall be a CADWELD exothermic connection.
46
www.erico.com
Factory-made connection
Copper SRG Strips
The pre-fabricated Signal Reference Grid sections are constructed with factory-made connections, and then each section is connected on site with type TW field made connections.
Welded to the SRG using CADWELD mold type TW 5 /16 hole in one end for connecting to equipment (same material as SRG) 40,481 circular mils 23 ohms impedence for 12 length at 20 MHz
Part No. B802D01A72 Thickness 26 gauge (0.0159") Width (in) 2 Length (in) 72
How to Specify
The Signal Reference Grid shall be manufactured from 2 wide by 26 gauge (0.0159 inch thick) copper strips on 2, 600 mm or 1200 mm centers. All crossovers shall be joined by welding. The SRG shall be furnished 4 to 16 wide. The sections shall be rolled on tubes with the outside of the roll protected for shipment. These sections shall be bonded to each other in the field with CADWELD connections.
SRG
Grid Spacing
B = 24 C = 48 F = 12 G = 36
Part No. SRGBD100 SRGBE100 SRGBG100
Width
A = 4 B = 6 C = 8 D = 10
24 x 24 24 x 24 24 x 24
E = 12 F = 14 G = 16 H = 2
J = 3 Feet K = 5 (3 digits) L = 7 M = 9
10 12 16
Length in
Note:
1. Other strip sizes are available 2. Other spacing is available 3. Roll weight usually limited to about 200 lbs. gross weight for convenience (1200 sq. ft.)
Width (ft)
www.erico.com
47
EQUIPOTENTIAL BONDING
EQUIPOTENTIAL BONDING
SRG
Helps to achieve a secure electrical connection in telecommunications Stranded wire allows for small radius bends Tinned copper lug and hardware included
Part No. CBNJ09 CBNJ09P10 Cable Size (AWG) 6 Stranded 6 Stranded Cable Length (ft) 9 9 Standard Package 25 50
48
www.erico.com
SRGC46
SRGC46
MBNC heavy duty clamps with stainless steel hardware, suitable for direct burial (UL 467 Listed) Allow for fast, simple and economical field connection of grounding and bonding wires
MBNC
Can accommodate additional pigtails that can be used to connect to building steel and equipment Can be combined with Universal Pedestal Clamp (part # UPCJ) for bonding to various pedestal sizes for mesh bonding networks (MBN)
Standard Package 25
UL Listed as a grounding/bonding clamp in addition to a cable support (Full Code compliance NEC Article 250 and 300)
Part No. Part No. SRGC46 SRGC46BR Description SRG Connector for #4 and #6 AWG solid or stranded conductor Pedestal mounting bracket for 7/8 square or 1 round pedestals Standard Package 20 10 MBNUPCJ82 Conductor Range (AWG)* Standard Conductor Range Pedestal Size (Round or Square) Package (Metric)*
7/8 2 8 solid 25 10 mm2 35 mm2 (2.2 cm 5.1 cm) 2 stranded * Stranded conductors #8 2 AWG (10 mm2 35 mm2): 7 or 19 strands
www.erico.com
49
EQUIPOTENTIAL BONDING
Mesh bonding conductors do not have to bend around each pedestal to conform to grid pattern
Overhang Configurations
M = Conductor Spacing L = Total Length W = Total Width
EquipotentialMesh Features
Silver brazed joints provide strength to resist separation during installation and bear the traffic of heavy vehicles Furnished in rolls up to 20 wide 500 lbs. maximum weight Conductor spacing in many rectangular configurations up to 24 x 48 in 2 increments Normally supplied in sections with standard overhang for interconnecting (1/2 conductor spacing + 2) No overhang
Half-spacing overhang
Mesh
EQUIPOTENTIAL BONDING
50
www.erico.com
Interconnecting
The CADWELD process provides a rapid and economical method of interconnecting mesh in the field Resulting weld is permanent and corrosion resistant Current carrying capacity equal to that of the conductor
Weight of Mesh
Net Weight (lbs) per 100 Square Feet
Conductor Spacing (in) 2x2 4x4 6x6 8x8 12 x 12 24 x 24 48 x 48 Copper-clad Steel Wire (AWG) #6 888 443 295 222 148 74 56 #8 558 279 186 139 93 47 35 #10 351 175 117 88 59 29 23 Solid Copper Wire (AWG) #6 974 487 325 243 163 91 62 #8 609 305 203 153 102 51 38 #10 383 192 128 96 64 32 24
CADWELD Mold Part No.* PGT-06CU PGT-06CS PGT-08CU PGT-08CS PGT-10CU PGT-10CS
Welding Material 25 15 15 15 15 15
Suggested Specifications
Prefabricated wire mesh shall be manufactured using (a)* AWG bare, solid (b)* wire on a (c)* inch x (c)* inch conductor spacing with all cross connections silver brazed using a 35% silver alloy brazing material and a non-corrosive flux. It shall be (d)* feet, (d)* inches wide by (e)* feet, (e)* inches long with (f)* inches overhang on both sides and both ends, and shall be wound on a fiber tube with the outside of the roll protected by wood strips interconnected with steel wire.
* (a) Wire size, #6, #8, #10, or #12 AWG. (b) 30% or 40% conductivity copper-clad or pure copper. (c) 2 x 2 minimum to 48 x 24 maximum (in 2 increments). (d) 20, 4 maximum. (e) Maximum length determined by weight, with a 500 lbs. maximum net weight. (f) No overhang, an overhang equal to one-half conductor spacing or an overhang equal to one-half conductor spacing plus 2 (for interconnecting).
Connection Type PG
Connection Type PT
www.erico.com
51
EQUIPOTENTIAL BONDING
65
Standard Configurations
6x8
M = Conductor Spacing in Inches L = Length in Feet (not including overhang) W = Width in Feet
Suggested Specifications
Standard Personnel Safety Mats:
Prefabricated personnel safety mats shall be manufactured using (a)* AWG bare, solid (b)* wire on (c)* inches x (c)* inches conductor spacing. All cross connections shall be silver brazed using a 35% silver brazing alloy and a noncorrosive flux. Overall mat size shall be (d)* feet x (d)* feet.
Prefabricated personnel safety mats shall be manufactured using (a)* AWG bare, solid (b)* wire on (c)* inches x (c)* inches conductor spacing with (e)* diameter solid copper center wire through the (f)* length overhanging each end (g)* inches. All cross connections shall be silver brazed using a 35% silver brazing alloy and a non-corrosive flux. Overall mat size shall be (d)* feet x (d)* feet.
* (a) #4, #6 or #8 AWG (see chart above). (b) 30% or 40% conductivity copper-clad or pure copper (#4 available only in pure copper). (c) Minimum of 2 inches, maximum of 12 inches in 2-inch increments (not available in 10-inch increments). (d) Standard sizes are 4 feet x 4 feet and 4 feet x 6 feet with maximum 6 feet x 8 feet. 5/16 inch (1/0 solid) or 3/8 inch (2/0 solid). (e) Stranded cable is also available (see chart above). (f) Longest or shortest. (g) Center wire is either flush (0-inch overhang) or with a 6-inch overhang.
EQUIPOTENTIAL BONDING
52
www.erico.com
Pool Mesh
Part No. POOLMESH250 POOLMESH2100 POOLMESH350 POOLMESH3100 Width (ft) 2 2 3 3 Length (ft) 50 100 50 100 Conductor (AWG) 8 Solid 8 Solid 8 Solid 8 Solid
Wire Size (AWG) 1/0 Solid or Stranded 2/0 Solid or Stranded 4/0 Stranded 250 MCM Stranded 300 MCM Stranded
L S T
* Weights are for copper-clad wire. Add 10% for approximate weight of solid copper wire. Safety mats are palletized for shipment. Add 50 pounds per pallet for gross weight. Maximum of 100 mats per pallet.
www.erico.com
53
EQUIPOTENTIAL BONDING
Bonding Devices
B21-Series Prefabricated Lug Bonds
Prefabricated lug bonds are custom made to specifications. Common usage includes cable tray bonding and grounding, structure bonds, surge arrester leads and power jumpers. Made with bare annealed copper cable Tinned copper NEMA lugs welded to the cable with CADWELD connections Part Number Coding
B21 2 1L X
Bond Length in inches
(from outer-most hole center)
Cable Code
#4 Stranded = 1L 1/0 Stranded = 2C #2 Stranded = 1V 2/0 Stranded = 2G #1 Stranded = 1Y 4/0 Stranded = 2Q 250 MCM Stranded = 2V = = = = = = = = 2 3 4 5 6 7 8 9 (see image A) (see image B) (see image C) (see image D) (see image E) (see image F) (see image G) (see image H)
Lug Conguration
ouble-Lug Bond, 1-Hole each on Straight Lugs D Double-Lug Bond, 2-Holes each on Straight Lugs Double-Lug Bond, 1-Hole each on 45 Lugs Double-Lug Bond, 2-Holes each on 45 Lugs ingle-Lug Bond Stub, 1-Hole on Straight Lug S Single-Lug Bond Stub, 2-Holes on Straight Lug Single-Lug Bond Stub, 1-Hole on 45 Lug Single-Lug Bond Stub, 2-Holes on 45 Lug
A
Cable Size Stranding (AWG) Lug Size (in) 1/8 x 1 1/8 x 1 1/8 x 1 1/8 x 1 1/8 x 1 3/16 x 1 3/16 x 1 B212-parts One Hole B2121L -X B2121V -X B2121Y -X B2122C -X B2122G -X B2122Q -X B2122V -X
B
B213-parts Two Hole B2131L -X B2131V -X B2131Y -X B2132C -X B2132G -X B2132Q -X B2132V -X
D
B214-parts One Hole 45 B2141L -X B2141V -X B2141Y -X B2142C -X B2142G -X B2142Q -X B2142V -X B215-parts Two Hole 45 B2151L -X B2151V -X B2151Y -X B2152C -X B2152G -X B2152Q -X B2152V -X
BONDING DEVICES
Single-Lug Bond Stub with 2-Hole Single-Lug Bond Stub with Single-Lug Bond Stub with 2-Hole NEMA Lug (Straight) 1-Hole NEMA Lug (45 Angle) NEMA Lug (45 Angle)
EQUIPOTENTIAL BONDING
E
Cable Size Stranding (AWG) 4 2 1 1/0 2/0 4/0 250 MCM 7-strand 7-strand 7-strand 7-strand 7-strand 7-strand 19-strand Lug Size (in) 1/8 x 1 1/8 x 1 1/8 x 1 1/8 x 1 1/8 x 1 3/16 x 1 3/16 x 1 B216-parts One Hole B2161L -X B2161V -X B2161Y -X B2162C -X B2162G -X B2162Q -X B2162V -X
F
B217-parts Two Hole B2171L -X B2171V -X B2171Y -X B2172C -X B2172G -X B2172Q -X B2172V -X
H
B218-parts One Hole 45 B2181L -X B2181V -X B2181Y -X B2182C -X B2182G -X B2182Q -X B2182V -X B219-parts Two Hole 45 B2191L -X B2191V -X B2191Y -X B2192C -X B2192G -X B2192Q -X B2192V -X
54
www.erico.com
Bonding Devices
Arc Weldable Bonds
Arc weldable bonds are 4-ft pieces of concentric cable (19-strand) which are flash-welded to steel rod for a bonding connection to structural steel and to rebar. Arc weldable bonds are an economical alternative to exothermic welding when only a few connections need to be made and an arc welder is available on site. The rod is sized to match the ampacity of the cable for fault currents. Complete instructions are provided.
Part No. EWB2G9164 EWB2L584 EWB2Q344 Cable Size (AWG) 2/0 Stranded 3/0 Stranded 4/0 Stranded Cable Length (ft) 4 4 4 Steel Rod Diameter (in) 9/16 5/8 3/4 Steel Rod Length (ft) 8 8 8
Welding to Rebar
Rebar
Structural Steel
Steel Rod
Rebar
Steel Rod
Copper Cable
Copper Cable
www.erico.com
55
EQUIPOTENTIAL BONDING
BONDING DEVICES
MBJ 6 - 150 - 6
Section mm2 Length mm Holes mm
Part No. 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 0.010 0.0167 0.022 0.033 0.018 0.018 0.035 0.035 0.033 0.033 0.040 0.050 0.050 0.082 0.027 0.039 0.052 0.052 0.052 0.064 0.077 0.013 0.032 0.047 0.062 0.075 0.092 0.155
Traditional braid
Displacement
Ampacity Thick. Section L J T A mm mm2 mm mm mm mm 33 33 33 33 50 33 33 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 50 38 60 60 60 60 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 0.037 0.054 0.072 0.089 0.089 0.110 0.180 0.052 0.077 0.120 0.120 0.120 0.110 0.110 0.127 0.150 0.153 0.150 0.140 0.255 0.255 0.210 0.210 0.210 0.200 0.200 0.340 0.254 0.254 0.508 0.508 150 10.5 23 200 10.5 23 250 10.5 23 250 25.5 40 300 10.5 23 500 10.5 23 100 10.5 28 150 10.5 28 200 6.5 28 200 10.5 28 200 12.5 28 200 16.5 28 200 18.5 28 250 10.5 28 300 6.5 28 300 10.5 28 300 16.5 28 300 18.5 28 500 10.5 28 500 12.5 28 300 6.5 28 300 10.5 28 300 12.5 28 300 16.5 28 300 22.5 40 500 10.5 28 250 16.5 50 250 30.5 50 500 16.5 50 500 30.5 50
100 10.5 23 150 10.5 23 200 6.5 23 200 10.5 23 200 12.5 23 250 10.5 23 300 10.5 23 500 10.5 23 100 10.5 23 150 10.5 23 200 10.5 23 250 10.5 23 300 10.5 23 500 10.5 23
EQUIPOTENTIAL BONDING
56
www.erico.com
Recommended Assembly
BJ-Series
Part No. 556900 556910 556920 Description BJ 6-150 S BJ 6-200 S BJ 10-300 S Section mm2 6 6 10 L mm 150 200 300 D mm 6.5 6.5 6.5 Intensity A 45 45 75 10 10 10 0.010 0.015 0.033
* Must have
www.erico.com
57
EQUIPOTENTIAL BONDING
*Braid: Bare Copper ____ Tinned Copper ____ Stainless Steel ____ *Contact: Bare Copper ____ Nickel Plated ____ Silver Plated ____ Tinned Copper ____ Design: *OAL (Overall Length) ______ Number of Rows ______ Number of Layers ______ *Pad # 1 L_____ x W______ x T ______ *Pad #1 Number of holes ____________ *Pad # 2 L_____ x W______ x T ______ *Pad #2 Number of holes ____________ *Estimated cross section ____________sq.mm
FJ 2Q 24
Cable Code #2 Solid = 1T 2/0 Stranded = 2G 4/0 Stranded = 2Q
Cable Code 1T 1T 1T 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2G 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q 2Q
Flexible Jumper
Cable Size (AWG) #2 Stranded #2 Stranded #2 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 2/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded
Length (in) 18 24 96 12 16 18 24 36 48 72 84 96 120 144 156 192 240 300 360 12 16 18 24 36 48 60 96 120 144 156 180 192 240 252 4/0 Conductor Size (AWG) 2/0 Pipe Size (in) * 1-1/4 3-1/2 * 1-1/4 3-1/2 CADWELD Mold Part No. VBC2G008V* VBC2G009 VBC2Q006V* VBC-2Q-003 Welding Material Size 90 90 115 115
FJ2G12 FJ2G16 FJ2G18 FJ2G24 FJ2G36 FJ2G48 FJ2G72 FJ2G84 FJ2G96 FJ2G120 FJ2G144 FJ2G156 FJ2G192 FJ2G240 FJ2G300 FJ2G360 FJ2Q12 FJ2Q16 FJ2Q18 FJ2Q24 FJ2Q36 FJ2Q48 FJ2Q60 FJ2Q96 FJ2Q120 FJ2Q144 FJ2Q156 FJ2Q180 FJ2Q192 FJ2Q240 FJ2Q252
* Made to exact pipe size. Add nominal pipe size mold to part number.
EQUIPOTENTIAL BONDING
Example for CADWELD Mold Part Numbering: 1. A 4 outside-diameter pipe is a 31/2 nominal pipe size. The mold part number for a 4/0 concentric conductor to this pipe would be:
VSC2Q V 3.50
Base number
(for at surface)
2. A nominal 2 x 21/4 H section uses mold code PH2. A 4/0 Type VB weld to this post would be VBC2QPH2.
58 www.erico.com
A235 B 2C 3 LH
Cable Code (AWG)
2C = 1/0 Stranded 2G = 2/0 Stranded 2Q = 4/0 Stranded
Left Hand (LH) or Right Hand (RH) Ground Lead Length (feet)
Part No. A235B2C3LH A235C2C1LH A235C2C1RH A235C2G2LH A235D2C1RH A235D2G2LH A235D2Q4RH A235E2C3RH A235E2G4LH A235E2Q2RH A235F2G2LH A235F2Q10RH A235F2Q5RH A235G2Q2RH A235G2Q4RH A235H2C4RH A235H2Q2LH A235H2Q2RH
Nominal Pipe Size (in) 1-1/4 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 2-1/2 3 3 3 3-1/2 3-1/2 4 4 4
Cable Size (AWG) 1/0 Stranded 1/0 Stranded 1/0 Stranded 2/0 Stranded 1/0 Stranded 2/0 Stranded 4/0 Stranded 1/0 Stranded 2/0 Stranded 4/0 Stranded 2/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 1/0 Stranded 4/0 Stranded 4/0 Stranded
A237 C 2Q 8
Cable Code (AWG)
2C = 1/0 Stranded 2G = 2/0 Stranded 2Q = 4/0 Stranded
Part No. A237C2Q8 A237D2G1 A237D2G2 A237D2Q4 A237E2Q1 A237E2Q4 A237F2C6 A237F2Q4 A237H2C1 A237H2C4 A237H2Q4
Cable Size (AWG) 4/0 Stranded 2/0 Stranded 2/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 1/0 Stranded 4/0 Stranded 1/0 Stranded 1/0 Stranded 4/0 Stranded
www.erico.com
59
EQUIPOTENTIAL BONDING
Post Frame
(size Y)
Post Frame
(size Y)
A238 XY 2S 12 LH
Nominal Nominal Clamp Gate Size Post Frame Codes (in) X Size (in) Y XY 1 1/4 EB 2 1/2 EC 1 1/2 3 3 1/2 4 1 1/4 1 1/2 1 1/4 1 1/2 1 1/4 1 1/2 FB FC GB GC HB HC
A239 XY 2S 24 2Q 3 LH
Nominal Nominal Clamp Gate Size Post Frame Codes (in) X Size (in) Y XY 1 1/4 EB 2 1/2 EC 1 1/2 3 3 /2
1
Jumper Length
(inches)
FB FC GB GC HB HC
Nominal Gate Nominal Post Jumper Cable Jumper Size (in) Frame Size (in) Size (AWG) Length (in) 2 1/2 2 1/2 2 1/2 2 1/2 2 /2
1
1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 /4
1
4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded
12 12 18 12 24 8 24 12 18 24 12 18 24 18 18 12 15 24 Part No. 4
A238EB2S18RH A238EC2S12LH A238EC2S24RH A238EC2S8LH A238FB2S24LH A238FC2S12LH A238FC2S18RH A238FC2S24LH A238GC2S12LH A238GC2S18RH A238GC2S24LH A238HB2S18LH A238HB2S18RH A238HC2S12LH A238HC2S15RH A238HC2S24LH
A239EB2S242Q3LH A239EB2S242Q3RH A239EB2S242Q4LH A239EC2S182Q6LH A239EC2S242C8RH A239EC2S242G4LH A239EC2S249F6LH A239EC2S249F6RH A239FC2S142C2RH A239FC2S242C6LH A239FC2S242G4RH A239FC2S242Q10R A239GB2S242Q4LH
Nominal Nominal Post Jumper Jumper Ground Lead Ground Gate Size Frame Size Cable Size Length Cable Size Lead (in) (in) (AWG) (in) (AWG) Length (ft) 2 1/2 1 1/4 4/0 Stranded 24 4/0 Stranded 3 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 3 3 3 3 3 1/2 3 1/2 3 1/2 3 1/2 3 1/2 4 4 4 4 4 4 4 4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 24 24 18 24 24 24 24 14 24 24 24 24 24 12 24 24 12 24 24 14 18 18 24 24 4/0 Stranded 4/0 Stranded 4/0 Stranded 1/0 Stranded 2/0 Stranded #9, 19-Strand #9, 19-Strand 1/0 Stranded 1/0 Stranded 2/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 4/0 Stranded 1/0 Stranded 4/0 Stranded #9, 19-Strand 1/0 Stranded 2/0 Stranded 3 4 6 8 4 6 6 2 6 4 10 4 4 2 4 4 4 1 4 2 6 1 10 2
A239GB2S242Q4RH A239GC2S122Q2RH A239GC2S242Q4LH A239GC2S242Q4RH A239HB2S122Q4LH A239HB2S242Q1RH A239HB2S242Q4LH A239HC2S142C2RH A239HC2S182Q6LH A239HC2S189F1RH A239HC2S242C10L A239HC2S242G2RH
EQUIPOTENTIAL BONDING
Outside Diameter (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500
1 /8 1 7/8 2 3 /8 2 /8
7 1
1 1/2 2 2 /2
1
3 3 1/2 4
3 /2 4 4 /2
1
60
www.erico.com
Cables
A805A01F Series
Bare bronze cable Extra flexible 3/16 diameter
Length (ft) 5 10 20
Length (ft) 5 10 20 20
A806A3F Series
Orange insulated bronze cable Extra flexible 3/16 diameter
Length (ft) 5 10 20 Features Two 1/4 bolt holes to afx Uses only one cable terminator. Other end of cable is grounded through metal reel case. Plated bolting surfaces and base.
A822SAS Series
Bare stainless steel cable Extra flexible 1/8 diameter
Length (ft) 5 10 20 Features Two 1/2 bolt holes to afx Uses only one cable terminator. Other end of cable is grounded through metal reel case. Plated bolting surfaces and base.
www.erico.com
61
EQUIPOTENTIAL BONDING
Cable length: 50
C Clamps
C Clamp B2615B
Features Die Cast Aluminum Max Jaw Opening: 1 Throat Depth: 1 Max Cable Size: 1/8 Contact Points: 2 ea., Stainless Steel Release Harness: Not Available
Features Bronze Max Jaw Opening: 1-1/4 Throat Depth: 1-1/2 Max Cable Size: 3/16 Length: 2-1/2 Contact Point: Bronze, Includes Crimp Lug
Features
Die Cast Aluminum Max Jaw Opening: 1-1/2 Throat Depth: 2 Max Cable Size: 3/16 Contact Points: 3 ea., Stainless Steel Release Harness: Included
Features Bronze Max Jaw Opening: 1 Throat Depth: 2-1/2 Max Cable Size: 3/16 Length: 9-1/2 Contact Points: 3 ea., Stainless Steel Release Harness: Included
1/0 x 72 Copper Cable with Tinned Copper Lug
Do
or Wa ll
Stainless Steel Length: 18 Furnished with 6 of 1/0 AWG copper conductor with a tinned copper lug CADWELD lug attached for connecting to the ground system
EQUIPOTENTIAL BONDING
Features Die Cast Aluminum Max Jaw Opening: 3/4 Throat Depth: 5/32 Max Cable Size: 3/16 Contact Points: Plated Steel Release Harness: Not Available Fits rods up to 3/4 and CADWELD Aircraft Grounding Receptacles B165 and B166
62
www.erico.com
PG 60
GROUND TESTER
PG 61
PG 60
RESISTANCE TESTER
PG 61
CLAMP ON PROBE
CABLE REELS
www.erico.com
63
ERICO offers a complete range of ground resistance testers. The units are lightweight and portable for ease of use in the field. Their robust design and splashproof construction help them withstand extreme conditions. The large LCD displays show required test connections and features a complete automatic test sequence for selected operations.
EST4620
Measures ground resistance (2- and 3-Point) Battery powered EST4620 2-, 3- and 4-Point Ground Tester Kit 35.07 Measures ground resistance (2- and 3-Point) and soil resistivity (4-Point) Step voltage tests and touch potential measurements Battery powered EST4630 2-, 3- and 4-Point Ground Tester Kit 35.01 Measures ground resistance (2- and 3-Point) and soil resistivity (4-Point) Step voltage tests and touch potential measurements AC powered with rechargeable NiMH batteries EST6472 2-, 3- and 4-Point Ground Tester Kit (**) 37.08
3-Point Fall-of-Potential measurement with manual or automatic frequency selection and automatic lead compensation 4 -Point soil resistivity measurement with automatic calculation of Rho and user selection of Wenner or Schlumberger test method Earth coupling testing (3-Point earth coupling measurement Manual or automatic frequency scan from 40 to 513Hz for test accuracy in electrically noisy environments Selectable test voltage 16 or 32V up to 250mA test current 2- and 4-Wire DC resistance measurement (Bond testing) with automatic polarity reversal Ground resistance with 2 clamps (no auxiliary rods) Includes DataView software for data storage, real-time display, analysis, report generation and system conguration Auto-off power management Automatic recognition of all electrode connections and their resistance value Stores up to 512 complete test results in internal memory Optically isolated USB communication AC powered with rechargeable NiMH batteries from wall charger or vehicle power
EST3640
EST4630 EST6472
Fall-of-Potential method
Auto-ranging: automatically selects the optimum range Designed to reject high levels of noise and interference Extremely simple to operate: connect press read LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections May also be used for continuity tests on bonding Rugged dustproof and rainproof field case Color-coded terminals CE Mark
* Kits include:
Two 300 color-coded leads on spools (red and blue) Two 100 color-coded leads (green and black) Four 14.5 T-shaped auxiliary ground electrodes One set of five spaded lugs 100 tape measure Carrying bag ** Clamp-on probe sold separately for use with EST6472 64
www.erico.com
Description
2 Heavy duty insulated thermoplastic 11 diameter reels with integral carrying handle, rugged base, and cranks for fast test lead retrieval Test leads are marked every 25 for easy auxiliary ground test stake positioning 500 of #18 silicone rubber insulated wire on each reel, two different colors for easy stake identification The far end of test lead remains attached to reel base, which eliminates tangling and speeds up the process of test stake deployment. A jack built into the reel base connects the test lead to the test stake with an included jumper
ESTREELKIT500 500 ft. Cable Reels 17.0
0.1A,>250V, 0.25 x Fuse Protection 1.25"; 30kA Interupt Capacity Test Kit Included
Clamp-on Probe
www.erico.com
65
Part No.
Description
Technical Information
Concentric Stranded Conductor Sizes
Size (AWG/MCM/mm2) 8 AWG 8 AWG 6 AWG 6 AWG 16 mm2 4 AWG 4 AWG 4 AWG 25 mm2 25 mm2 2 AWG 2 AWG 2 AWG 35 mm2 50 mm2 1/0 AWG 1/0 AWG 1/0 AWG 2/0 AWG 2/0 AWG 2/0 AWG 70 mm2 3/0 AWG 3/0 AWG 3/0 AWG 95 mm2 95 mm2 4/0 AWG 4/0 AWG 4/0 AWG 120 mm2 250 MCM 250 MCM 150 mm2 300 MCM 300 MCM 185 mm2 400 MCM 240 mm2 500 MCM 500 MCM Circular Mils 16,510 16,510 26,240 26,240 31,600 41.740 41,740 41,740 49,300 49,300 66,360 66,360 66,360 66,360 98,500 105,600 105,600 105,600 133,100 133,100 133,100 138,000 167,800 167,800 167,800 187,000 187,000 211,600 211,600 211,600 237,000 250,000 250,000 296,000 300,000 300,000 365,000 400,000 474,000 500,000 500,000 750,000 987,000 1,000,000 Stranding Solid 7/.0486 Solid 7/.0612 7/1.17 Solid 7/.0772 19/.0469 7/2.14 mm 19/1.35 Solid 7/.0974 19/.0591 19/1.53 mm 19/1.78 mm Solid 7/.1228 19/.0745 Solid 7/.1379 19/.0837 19/2.14 mm Solid 7/.1548 19/.0940 37/1.78 mm 19/2.52 Solid 7/.1739 19/.1055 37/2.03 mm 19/.1147 37/.0822 37/2.25 mm 19/.1257 37/.0900 27/2.52 mm 37/.1040 61/2.25 mm 19/.1622 37/.1162 61/.1109 61/3.20 mm 61/.1280 Nominal O.D. of Strand 0.0486 0.0612 0.0461 0.0772 0.0469 0.0843 0.0531 0.0974 0.0591 0.0602 0.0701 0.1228 0.0745 0.1379 0.0837 0.0843 0.1548 0.0940 0.0700 0.0992 0.1739 0.1055 0.0799 0.1147 0.0822 0.0886 0.1257 0.0900 0.0992 0.1040 0.0886 0.1622 0.1162 0.1109 0.1260 0.1280 Approx, O.D. (inches) 0.1285 0.1460 0.1620 0.1840 0.2010 0.2043 0.2320 0.2350 0.2530 0.2660 0.2576 0.2920 0.2920 0.3010 0.3500 0.3249 0.3690 0.3730 0.3648 0.4140 0.4190 0.4210 0.4096 0.4650 0.4700 0.4910 0.4960 0.4600 0.5220 0.5280 0.5600 0.5750 0.5750 0.6200 0.6290 0.6290 0.6950 0.7200 0.7970 0.8130 0.8130 0.9980 1.1340 1.1520 Approx, O.D. (mm) 3.26 3.71 4.11 4.67 5.11 5.19 5.89 5.97 6.43 6.76 6.54 7.42 7.42 7.65 8.89 8.25 9.37 9.47 9.27 10.52 10.64 10.69 10.40 11.81 11.94 12.47 12.60 11.68 13.26 13.41 14.22 14.61 14.61 15.75 15.98 15.98 17.65 18.29 20.24 20.65 20.65 25.35 28.80 29.26 Weight (lbs/mft) 50.0 50.1 79.5 81.1 96.1 126.3 129.0 129.0 152.5 152.5 200.9 204.9 205.0 211.0 287.6 319.5 326.0 326.0 402.8 410.9 410.9 415.3 507.8 518.0 518.0 576.5 576.5 610.5 653.0 653.0 737.1 771.0 771.0 896.4 926.9 926.9 1124.1 1235.2 1478.2 1544.0 1544.0 2316.0 2990.8 3088.0 CADWELD Cable Code 1D 1E 1G 1H W3 1K 1L 1L Y1 Y1 1T 1V 1V Y2 Y3 2B 2C 2C 2F 2G 2G Y4 2K 2L 2L Y5 Y5 2P 2Q 2Q Y6 2V 2V Y7 3A 3A Y8 3H Y9 3Q 3Q 4L W1 4Y
Technical information
1000 MCM
66
www.erico.com
Technical Information
DSA Copper-bonded Conductor
Cable Stranding 7/#10 7/#8 7/#7 7/#6 7/#5 19/#9 7/#4 19/#8 19/#7 37/#9 19/#6 37/#8 19/#5 37/#7 Nominal Diameter .306 .385 .433 .486 .546 .572 .613 .642 .721 .801 .810 .899 .910 1.010 kcmil 72.7 115.6 145.7 183.8 231.7 248.8 292.2 313.7 395.5 484.4 498.8 610.9 628.9 770.3 Equivalent Copper Size* 3 AWG 1 1/0 2/0 3/0 3/0 4/0 4/0 250 Kcmil 300 350 400 450 500 CADWELD Cable Code 9A 9B 9C 9D 9E 9F 9L 9G 9H 7W 9J 7V 9K 9M 3/8 1/4 3/16 1/8
1/2
Reinforcing Bars
Rebar Sizes 3 4 5 6 7 8 9 10 11 14 18 Nominal Dimensions Equivalent CADWELD CrossCopper Rebar Code Dia. (inches) Secitonal Area Sizes* (Sq. inches) .375 .11 9 AWG 51 .500 .625 .750 .875 1.000 1.128 1.270 1.410 1.693 2.257 .20 .31 .44 .60 .79 1.00 1.27 1.56 2.25 4.00 7 5 3 2 1 1/0 2/0 3/0 250 kcmil 450 52 53 54 55 56 57 58 59 60 61
Area Square Inches x 1273 = kcmil Square Millimeters x 1.974 = kcmil kcmil x 0.5067 = Square Millimeters Density Copper: 0.323 lb/in3 Steel: 0.283 lb/in3
www.erico.com
67
Technical information
Useful Conversions
Technical Information
Steel Pipe Sizes
Standard Weight (Schedule 40)
Nominal Size (inches) 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 8 10 O.D. (inches) 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 5.563 6.625 8.625 10.750
WARNING ERICO products shall be installed and used only as indicated in ERICOs product instruction sheets and training materials. Instruction sheets are available at www.erico. com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICOs instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyers receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICOs prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYERS EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICOs employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER.
Technical information
68
www.erico.com
Data Center
Equipotential Bonding
of Permanently Installed Swimming Pools
ERITECH products designed to help provide data center electrical protection solutions.
Bonding requirements for permanently installed swimming pools to help eliminate voltage gradients.
Wind Power Solutions
Grounding, lightning protection, electrical connection and cable management solutions for the solar power industry.
Grounding, Lightning Protection and Surge Protection
For Telecommunications
Foundation grounding and construction, bonding, power connections, surge protection, and lightning protection products for the wind energy industry.
Product solutions to help protect telecommunications facilities against electrical noise, lightning induced surges and transients.
Featured
Lightning
11/22/10
11:50:58
AM
E1564LT
09WWEN
_2b.indd
ERICO offers a diverse range of technically advanced lightning protection systems and products to meet industry standards and requirements.
Grounding, bonding, lightning protection and surge protection solutions necessary to help provide comprehensive facility electrical protection.
www.erico.com
69
www.erico.com
AUSTRALIA
Phone 1-800-263-508 Fax 1-800-423-091
CHINA
Phone +86-21-3430-4878 Fax +86-21-5831-8177
HUNGARY
Phone 06-800-16538 Fax +39-0244-386-107
NORWAY
Phone 800-100-73 Fax 800-100-66
SWITZERLAND
Phone 0800-55-86-97 Fax 0800-55-96-15
BELGIUM
Phone 0800-757-48 Fax 0800-757-60
DENMARK
Phone 808-89-372 Fax 808-89-373
INDONESIA
Phone +62-21-575-0941 Fax +62-21-575-0942
POLAND
Phone +48-71-349-04-60 Fax +48-71-349-04-61
THAILAND
Phone +66-2-267-5776 Fax +66-2-636-6988
BRAZIL
Phone +55-11-3623-4333 Fax +55-11-3621-4066
FRANCE
Phone 0-800-901-793 Fax 0-800-902-024
ITALY
Phone 800-870-938 Fax 800-873-935
SINGAPORE
Phone +65-6-268-3433 Fax +65-6-268-1389
CANADA
Phone +1-800-677-9089 Fax +1-800-677-8131
GERMANY
Phone 0-800-189-0272 Fax 0-800-189-0274
MEXICO
Phone +52-55-5260-5991 Fax +52-55-5260-3310
SPAIN
Phone 900-993-154 Fax 900-807-333
UNITEDKINGDOM
Phone 0808-2344-670 Fax 0808-2344-676
CHILE
Phone +56-2-370-2908 Fax +56-2-369-5657
HONGKONG
Phone +852-2764-8808 Fax +852-2764-4486
NETHERLANDS
Phone 0800-0200-135 Fax 0800-0200-136
SWEDEN
Phone 020-790-908 Fax 020-798-964
UNITEDSTATES
Phone 1-800-753-9221 Fax +1-440-248-0723
ANSI is a registered trademark of the American National Standards Institute. ASME is a registerd trademark of the American Society of Mechanical Engineers. ASTM is a registerd trademark of American Society for Testing and Materials. BICSI is a registered trademark of BICSI, Inc. CSA is a registered trademark of The Canadian Standards Association Intl. cULus is a registered trademark of Underwriters Laboratories, Inc. DataView is a registered trademark of Chauvin Arnoux, Inc. EIA is a registered service mark of the Electronic Industries Alliance. IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Inc. NEC is a registered trademark of, and National Electrical Code (NEC) standard is a copyright of the National Fire Protection Association. NEMA is a registered trademark of the National Electrical Manufacturers Association. NFGC is a registered trademark of, and National Fuel Gas Code (NFGC) standard is a copyright of the National Fire Protection Association. NFPA is a registered trademark of the National Fire Protection Association. SAE is a registered trademark of SAE Intermational. TIA is a registered service mark of the Telecommunications Industry Association. Copyright 2000, 2006, 2007, 2009, 2011, 2012 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.
E1081C-NAEN E590CT12NAEN 75M0612